Plan Review Stops For Permit 06081911 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2006-10-18 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2006-10-18 |
Time |
07:48 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2006-10-18 |
Time |
07:48 |
Sent To |
PC |
|
Notes |
2006-10-18 07:50:41 | | | | | PASSED | | | | 1) STRUCTURAL IS IN COMPLIANCE ALTHOUGH ZONING | | REQUIREMENTS SHALL BE MET BEFORE PERMIT CAN BE ISSUED | | | | 2) PER 713.13(2) F.S. | | IF THE IMPROVEMENT DESCRIBED IN THE NOC HAS NOT | | COMMENCED WITHIN 90 DAYS OF RECORDING THE NOTICE IS | | VOID | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-09-12 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2006-09-12 |
Time |
08:38 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2006-09-12 |
Time |
08:38 |
Sent To |
PC |
|
Notes |
2006-09-12 00:00:00 | | | | | DENIED | | | | 1) PLEASE SEE ZONING COMMENTS, PROVIDE | | PROOF OF PREVIOUS PERMITTED SCREEN | | ENCLOSURE | | | | 2) PROVIDE ENGINEERING TABLE OR CALCS | | FOR BEAM AND COLUMN SIZES BASED ON THE | | SPANS AND ON CENTER SPACING | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-10-17 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-17 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-17 |
Time |
10:52 |
Sent To |
B |
|
Notes |
2006-10-17 10:52:38 | TO "AMORSE" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-10-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-11 |
Time |
13:56 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-11 |
Time |
13:56 |
Sent To |
Z |
|
Notes |
2006-10-11 13:57:05 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-09-11 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-11 |
Time |
14:06 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-11 |
Time |
14:06 |
Sent To |
B |
|
Notes |
2006-09-11 00:00:00 | TO "MISC" BOX#2 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2006-09-12 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-25 |
Time |
10:27 |
Sent To |
|
|
Notes |
2006-08-25 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2006-10-16 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2006-10-16 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2006-10-16 |
Time |
15:13 |
Sent To |
I |
|
Notes |
2006-10-16 15:27:11 | ***FAILED*** | | | | THE FOLLOWING ITEMS WERE NOT ADDRESSED FROM THE | | SEPTEMBER 5, 2006, REVIEW: | | | | 1) PLEASE PROVIDE PROOF THAT A PERMIT WAS ISSUED FOR | | THE PREVIOUS SCREEN ENCLOSURE AND THAT IT WAS DAMAGED | | BY A HURRICANE.THE LOCATION OF THE PROPOSED SCREEN | | ENCLOSURE DOES NOT MEET THE CURRENT SETBACK | | REQUIREMENTS.WITHOUT PROOF OF A PREVIOUS APPROVAL, | | THE REPLACEMENT MUST MEET CURRENT SETBACK REQUIREMENTS, | | WHICH ARE THE FOLLOWING: | | | | FRONT (WEST - PINEWOOD): 25 FEET | | SIDE (NORTH): 5 FEET | | CORNER SIDE (SOUTH - 58TH STREET): 12.5 FEET | | REAR (EAST): 5 FEET | | | | QUESTIONS/COMMENTS, PLEASE CONTACT JOHN ROACH, SENIOR | | PLANNER, AT (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-09-06 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-09-06 |
Time |
11:50 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-09-02 |
Time |
13:46 |
Sent To |
I |
|
Notes |
2006-09-06 00:00:00 | 9/5/06 DENIED, | | 1. PLEASE PROVIDE PROOF OF PERMIT FOR | | SCREEN ENCLOSURE AND PROOF OF HURRICANE | | DAMANGED. | | 2. THE LOCATION OF THE SCREEN ENCLOSURE | | WILL NOT MEET THE CURRENT SENT BACK. | | 3. WITHOUT THE PROOF OF THE APPROVED | | PERMIT, THE REPLACED SCREEN ENCLOSURE | | MUST MEET THE CURRENT SETBACK.MUST SIT | | BEYOND THE 25FT FRONT SETBACK OF | | PINEWOOD AVE (SHORTEST PORTION OF THE | | LOT). | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 | 2006-09-02 00:00:00 | REQUESTING COPIES OF THE OLD PERMIT FOR | | SCREEN ENCLOSURE. |
|
|