Plan Review Details - Permit 06081657
Plan Review Stops For Permit 06081657 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2006-09-24 |
|
|
Cont ID |
|
Sent By |
rnuquist |
Date |
2006-09-24 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
rnuquist |
Date |
2006-09-24 |
Time |
10:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-10-17 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-10-17 |
Time |
14:36 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-10-17 |
Time |
14:30 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-09-01 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-09-01 |
Time |
13:29 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-09-01 |
Time |
13:29 |
Sent To |
M |
|
Notes |
2006-09-01 00:00:00 | | | | | | | | | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} THERE MUST BE A DISCONNECT FROM THE | | GENERATOR WHERE THE CONDUCTORS ENTER THE | | BUILDING. IF ALL DISCONNECTS CANNOT BE | | GROUPED PER 230.72, SEE THAT ALL | | ARTICLES FROM 225.31 THROUGH 225.39, ARE | | COMPLIED WITH. | | | | 2} 700.15 LOADS ON EMERGENCY BRANCH | | CIRCUITS. | | NO APPLIANCES AND NO LAMPS, OTHER THAN | | THOSE SPECIFIED AS REQUIRED FOR | | EMERGENCY USE, SHALL BE SUPPLIED BY | | EMERGENCY LIGHTING CIRCUITS. PROVIDE A | | PANEL SCHEDULE FOR THE | | EMERGENCY/GENERATOR PANEL. | | | | 3} THE PERSON TAKING RESPONSIBILITY FOR | | THE PLAN/DRAWINGS, SHALL PRINT AND SIGN | | THEIR NAME ON THE SHEETS THEY DRAW. | | PLEASE DO THIS PRIOR TO RESUBMITTING. | | | | 4} PLEASE LOCATE ALL SERVICE EQUIPMENT | | ON THE PLAN, METER ENCLOSURE, | | DISCONNECTS AND PANELS, SO THAT | | COMPLIANCE WITH ARTICLES 225 AND 230 CAN | | BE REVIEWED. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2006-09-06 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-09-06 |
Time |
15:55 |
Rev Time |
0.15 |
Received By |
mperson |
Date |
2006-09-06 |
Time |
15:55 |
Sent To |
B |
|
Notes |
2006-09-06 00:00:00 | CONTRACTOR INFORMATION | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | BEFORE FINAL GEN/RES INSPECTION. | | | | ******IMPORTANT INFORMATION****** | | AS OF 8/25/06 GENERATOR (GEN/RES AND | | GEN/COM) PERMIT APPLICATIONS SHALL NOT | | BE ACCEPTED UNLESS THE ELECTRICAL INFOR- | | MATION AND GAS (OR DIESEL) INFORMATION | | IS ALL SUBMITTED AT THE SAME TIME. THE | | GENERATOR, ELECTRICAL AND GAS/DIESEL IN- | | FORMATION WILL BE ROUTED TOGETHER. THIS | | WILL ENSURE THAT ALL OF THE INFORMATION | | (PARTICULARLY THE MANUFACTURER'S SPECI- | | FICATIONS AND INSTALLATION INSTRUCTIONS) | | ARE AVAILABLE TO ALL PLAN REVIEWERS. | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-08-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-24 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-24 |
Time |
14:49 |
Sent To |
E |
|
Notes |
2006-08-24 00:00:00 | TO "GEN-RES" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-09-24 |
|
|
Cont ID |
|
Sent By |
rnuquist |
Date |
2006-09-24 |
Time |
10:16 |
Rev Time |
0.00 |
Received By |
rnuquist |
Date |
2006-08-18 |
Time |
16:30 |
Sent To |
PC |
|
Notes |
2006-08-18 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2006-09-06 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-09-06 |
Time |
09:14 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2006-09-06 |
Time |
09:14 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2006-08-20 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-08-20 |
Time |
17:00 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-08-20 |
Time |
17:00 |
Sent To |
I |
|
Notes |
2006-08-22 00:00:00 | NOTE: | | THE PROPOSED GENERATOR SHALL NOT BE | | CLOSER THAN 3.5FT FROMSIDE PROPERTY | | LINE. |
|
|
|