Plan Review Details - Permit 06081578
Plan Review Stops For Permit 06081578 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2006-09-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2006-09-14 |
Time |
11:12 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-09-14 |
Time |
11:12 |
Sent To |
|
|
Notes |
2006-09-14 00:00:00 | NOA/ENGINEERING FILED WITH MASTER | | 05090770 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-09-13 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2006-09-13 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-09-13 |
Time |
14:01 |
Sent To |
|
|
Notes |
2006-09-13 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC RFLORIDA BUILDING CODE 2004 | | RESIDENTIAL | | FBC EBFLORIDA BUILDING CODE 2004 | | EXISTING BUILDING CODE | | FBC*CITY OF WEST PALM BEACH | | AMENDMENTS TO THE FBC2004 | | | | 1.)THE DESIGN PRESSURE SPECIFIED BY | | C-BUCK ENGINEERING FOR ZONE 3 IS LESS | | THAN SPECIFIED BY ENGINEER OF RECORD, | | SEE SHEET S103 (-140.7).EITHER REVISE | | SHEET S103 OR CHANGE ROOF SPECIFICATION. | | | | 2.)PRODUCT APPROVALS ARE TO BE | | REVIEWED BY DESIGNER OF RECORD, | | FBC*106.3.3. | | | | 3.)THE ENGINEERING SUBMITTED IS A | | PHOTOCOPY.THREE COPIES OF ALL | | DOCUMENTS REQUIRED AS THIS IS A RESIDENT | | INSPECTOR JOB. | | | | 4.)THIS PRODUCT APPROVAL REVISED THE | | MASTER PERMIT.WHEN RESUBMITTING, | | PLEASE SUBMIT AS A REVISION TO THE | | MASTER 05090770. | | | | 5.)THE ORIGINAL PERMIT WAS ISSUED WITH | | A PROVISO THAT A THIRD SET BE SUBMITTED | | FOR STAMPING FOR THE RESIDENT INSPECTOR. | | THIS HAS NOT BEEN DONE.PLEASE ADDRESS. | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-08-21 |
|
|
Cont ID |
|
Sent By |
jgomez |
Date |
2006-08-21 |
Time |
09:58 |
Rev Time |
0.50 |
Received By |
jgomez |
Date |
2006-08-21 |
Time |
09:58 |
Sent To |
|
|
Notes |
2006-08-18 00:00:00 | BUILDING REVIEW CHECKLIST: | | 1- THIS IS A REVISION. PRODUCT APPROVAL | | SUBMITTED IS DIFFERENT FROM THE ONE | | APPROVED AT THE TIME OF ISSUING THE | | BUILDING PEMIT. THEREFORE, OWES $60.00 | | FOR REVISION FEES. | | | | 2- DADE COUNTY NOA 03-0213.01 SUBMITTED | | EXPIRED ON 07/19/2006. NEED TO PROVIDE | | CURRENT DADE COUNTY NOA. | | | | 3- PROVIDE RAS 117 CALCULATIONS FOR NAIL | | ENHANCING AT PERIMETER AND CORNER AREAS | | AS REQUIRED BY GENERAL LIMITATION #7 ON | | PAGE 23 OF DADE COUNTY NOA. | | | | 4- NEED FLORIDA PRODUCT APPROVAL COVER | | PAGE FOR 2004 CODE VERSION. ONE | | SUBMITTED IS FOR 2001. GO TO DCA WEBSITE | | WWW.FLORIDABUILDING.ORG TO DOWNLOAD | | CURRENT CODE VERSION. | | | | JULIO GOMEZ | | BUILDING PLANS EXAMINER | | (561)805-6712 |
|
|
|