Plan Review Details - Permit 06081397
Plan Review Stops For Permit 06081397 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2007-03-14 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-03-14 |
Time |
17:30 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-03-14 |
Time |
17:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-02-20 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2007-02-20 |
Time |
12:52 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2007-02-20 |
Time |
12:52 |
Sent To |
|
|
Notes |
2007-02-20 12:54:43 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBC FLORIDA BUILDING CODE 2004 | | FBC* CITY OF WEST PALM BEACH AMENDMENTS TO THE FBC2004 | | FBC RFLORIDA BUILDING CODE 2004 RESIDENTIAL | | | | 1.)SHOW THE EMERGENCY MEANS OF ESCAPE FBC R310.THE | | FRONT DOOR IS SHOWN WITH A SHUTTER; NO OTHER HINGED | | DOORS SHOWN.PLEASE CONTACT ME IF YOU NEED ASSISTANCE. | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2006-10-20 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2006-10-20 |
Time |
07:52 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2006-10-20 |
Time |
07:52 |
Sent To |
PC |
|
Notes |
2006-10-20 07:58:38 | | | | | DENIED | | | | 1) PLEASE NOTE THE CORRECTION MADE TO PLAN AS PREVIOUS | | COMMENT REGUARDING SHUTTER SPAN WAS NOT CORRECTED, | | PANEL CANNOT BE MOUNTED HORIZONTALLY BECAUSE IT WOULD | | EXCEED THE MAXIMUM ALLOWABLE SPAN FOR THE PRESSURE | | SHOWN (MAX SPAN 85") OPENING IS 93" + 6" EDGE DISTANCE | | = 99" THEREFORE PANEL SHALL BE INSTALLED VERTICALLY | | | | 2) ALSO THE SHUTTER SPANSON THE SCHEDULE INDICATE | | THAT THE PANELS ARE MOUNTED HORIZONTALLY AS THEY ARE 2" | | LARGER THAN THE WIDTH PLEASE VERIFY THIS | | | | 3) PRODUCT APPROVALS SHOW AN EDGE DISTANCE OF 31/2" | | THEREFORE THE PANEL LENGTH/SPANS SHOULD BE APPROX 7" | | LARGER THAN THE OPENING SIZE (HORZ FOR WIDTH VERT FOR | | HEIGHT) | | | | 4) PER 713.13(2) F.S. | | IF THE IMPROVEMENT DESCRIBED IN THE NOC HAS NOT | | COMMENCED WITHIN 90 DAYS OF RECORDING THE NOTICE IS | | VOID | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-08-27 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2006-08-27 |
Time |
14:49 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2006-08-27 |
Time |
14:49 |
Sent To |
PC |
|
Notes |
2006-08-27 00:00:00 | | | | | DENIED | | | | 1)PROVIDE LOCATION OF OPENING WITH | | CLEAR PANELS AND THE DIRETION THAT THE | | PANELS WILL RUN. BE AWARE THAT THE MAX | | PANEL LENGTHS FOR CLEAR PANELS WITH | | PRESSURES OVER -40 ARE ALL BELOW 8'-0" | | FOR EXAMPLE OPENING #16 HORIZONTAL LEGTH | | IS 95" THE PRESSURE IS -53.48 THE MAX | | PANEL LENGTH IS 7'-2" OR 85" THEREFORE | | IT WILL NOT WORK | | | | 2)A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT IS REQUIRED PRIOR TO | | A PERMIT BEING ISSUED | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-03-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-10 |
Time |
15:07 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-10 |
Time |
15:07 |
Sent To |
B |
|
Notes |
2007-03-10 15:07:30 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-02-13 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-13 |
Time |
10:11 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-13 |
Time |
10:11 |
Sent To |
B |
|
Notes |
2007-02-13 10:12:15 | TO "SHILL" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-10-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-19 |
Time |
10:48 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-19 |
Time |
10:48 |
Sent To |
B |
|
Notes |
2006-10-19 10:49:01 | TO "AMORSE" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2006-08-27 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-16 |
Time |
14:41 |
Sent To |
|
|
Notes |
2006-08-16 00:00:00 | TO "MISC" BOX#1 |
|
|
|