Plan Review Stops For Permit 06081382 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2006-09-24 |
|
|
Cont ID |
|
Sent By |
rnuquist |
Date |
2006-09-24 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
rnuquist |
Date |
2006-09-24 |
Time |
10:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2007-03-22 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-03-22 |
Time |
16:38 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2007-03-22 |
Time |
16:23 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-10-17 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-10-17 |
Time |
13:31 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-10-17 |
Time |
13:28 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-09-01 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-09-01 |
Time |
09:24 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-09-01 |
Time |
09:22 |
Sent To |
M |
|
Notes |
2006-09-01 00:00:00 | | | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} THERE MUST BE A DISCONNECT FROM THE | | GENERATOR WHERE THE CONDUCTORS ENTER THE | | BUILDING. IF ALL DISCONNECTS CANNOT BE | | GROUPED PER 230.72, SEE THAT ALL | | ARTICLES FROM 225.31 THROUGH 225.39, ARE | | COMPLIED WITH. | | | | 2} 700.15 LOADS ON EMERGENCY BRANCH | | CIRCUITS. | | NO APPLIANCES AND NO LAMPS, OTHER THAN | | THOSE SPECIFIED AS REQUIRED FOR | | EMERGENCY USE, SHALL BE SUPPLIED BY | | EMERGENCY LIGHTING CIRCUITS. PROVIDE A | | PANEL SCHEDULE FOR THE | | EMERGENCY/GENERATOR PANEL. | | | | 3} THE PERSON TAKING RESPONSIBILITY FOR | | THE PLAN/DRAWINGS, SHALL PRINT AND SIGN | | THEIR NAME ON THE SHEETS THEY DRAW. | | PLEASE DO THIS PRIOR TO RESUBMITTING. | | | | 4} PLEASE LOCATE ALL SERVICE EQUIPMENT | | ON THE PLAN, METER ENCLOSURE, | | DISCONNECTS AND PANELS, SO THAT | | COMPLIANCE WITH ARTICLES 225 AND 230 CAN | | BE REVIEWED. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2006-09-06 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-09-06 |
Time |
15:12 |
Rev Time |
0.15 |
Received By |
mperson |
Date |
2006-09-06 |
Time |
15:12 |
Sent To |
B |
|
Notes |
2006-09-06 00:00:00 | CONTRACTOR INFORMATION | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | BEFORE FINAL GEN/RES INSPECTION. | | | | ******IMPORTANT INFORMATION****** | | AS OF 8/25/06 GENERATOR (GEN/RES AND | | GEN/COM) PERMIT APPLICATIONS SHALL NOT | | BE ACCEPTED UNLESS THE ELECTRICAL INFOR- | | MATION AND GAS (OR DIESEL) INFORMATION | | IS ALL SUBMITTED AT THE SAME TIME. THE | | GENERATOR, ELECTRICAL AND GAS/DIESEL IN- | | FORMATION WILL BE ROUTED TOGETHER. THIS | | WILL ENSURE THAT ALL OF THE INFORMATION | | (PARTICULARLY THE MANUFACTURER'S SPECI- | | FICATIONS AND INSTALLATION INSTRUCTIONS) | | ARE AVAILABLE TO ALL PLAN REVIEWERS. | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-03-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-03-14 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-03-14 |
Time |
11:17 |
Sent To |
E |
|
Notes |
2007-03-14 11:17:30 | TO "BTROBAUG" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-01-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-18 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-18 |
Time |
10:51 |
Sent To |
P |
|
Notes |
2007-01-18 10:51:29 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-01-10 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2007-01-16 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-10 |
Time |
16:49 |
Sent To |
Z |
|
Notes |
2007-01-10 16:49:23 | TO "Z" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-10-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-03 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-03 |
Time |
15:16 |
Sent To |
E |
|
Notes |
2006-10-03 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-08-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-24 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-24 |
Time |
14:37 |
Sent To |
E |
|
Notes |
2006-08-24 00:00:00 | TO "GEN-RES" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-09-24 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-09-24 |
Time |
12:08 |
Rev Time |
0.00 |
Received By |
rnuquist |
Date |
2006-08-16 |
Time |
15:00 |
Sent To |
|
|
Notes |
2006-08-16 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2006-09-06 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-09-06 |
Time |
08:47 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2006-09-06 |
Time |
08:47 |
Sent To |
G |
|
Notes |
2006-09-06 00:00:00 | *** PROVISO *** | | 1) PER 2004 FBC, FUEL GAS - POWERED | | EQUIPMENT - PERMANENTLY INSTALLED | | EQUIPMENT POWERED BY INTERNAL COMBUSTION | | ENGINES SHALL BE INSTALLED IN ACCORDANCE | | WITH MANUFACTURE'S INSTALLATION | | INSTRUCTIONS AND NFPA 37. | | | | NFPA 37 INSTALLATION & USE OF STATIONARY | | COMBUSTION ENGINES & GAS TURBINES: | | 4.1.4ENGINES (GENERATORS) LOCATED | | OUTDOORS SHALL BE MINIMUM OF 5 FT FROM | | OPENINGS IN WALLS & AT LEAST 5 FT FROM | | STRUCTURES HAVING COMBUSTIBLE WALLS.A | | MINIMUM CLEARANCE IS NOT REQUIRED WHEN | | (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | RESISTANCE RATING OF 1 HOUR OR (2) THE | | WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF | | NON-COMBUSTIBLE MATERIALS, AND IT HAS | | BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | MATERIALS OUTSIDE THE ENCLOSURE. | | INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS | | SHOULD NOT TERMINATE UNDER STRUCTURES OR | | WHERE THE EXHAUST MIGHT BE DRAWN INTO | | THE VENTILATION INTAKES. | | | | 2004 FMC 804.3.5 #3, WHERE THE | | TERMINATION IS LOCATED BELOW AN ADJACENT | | ROOF STRUCTURE, THE TERMINATION POINT | | SHALL BE LOCATED AT LEAST 3 FT FROM THE | | ROOF STRUCTURE. | | | | PLEASE NOTE, WHILE ZONING ALLOWS | | MECHANICAL EQUIPMENT TO ENCROACH 4 FT | | INTO THE REQUIRED SETBACK, GENERATORS | | SHALL MAINTAIN THE REQUIRED ABOVE | | MENTIONED CLEARANCES TO THE ADJACENT | | PROPERTY STRUCTURES, I.E. FENCE, | | BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | | FOLLOW MANUFACTURE'S RECOMMENDED | | CLEARANCES AROUND EQUIPMENT FOR | | SERVICING,AND PROVIDE MANUFACTURE'S | | INSTALLATION INSTRUCTIONS AT THE JOBSITE | | FOR THE FIELD INSPECTOR. | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2007-01-13 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2007-01-13 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2007-01-13 |
Time |
10:33 |
Sent To |
I |
|
Notes |
2007-01-16 10:51:31 | PROVISO:THE PROPOSED ABOVE GROUND TANK SHALL NOT BE | | CLOSER THAN 6.25FT FROM SIDE PROPERTY LINE. | | THE PROPOSED ABOVE GROUND TANK SHALL BE LANDSCAPE | | BUFFER FROM THE VIEW OF THE PUBLIC. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2006-08-23 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-08-23 |
Time |
11:57 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-08-23 |
Time |
11:56 |
Sent To |
I |
|
Notes |
2006-08-23 00:00:00 | PROVISO: THE PROPOSED GENERATOR SHALL | | NOT BE CLOSER THAN 21FT FROMFRONT | | PROPERTY LINE AND 3.5FT FROM THE SIDE | | PROPERTY LINE. |
|
|