Plan Review Stops For Permit 06080671 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2006-09-23 |
|
|
Cont ID |
|
Sent By |
rnuquist |
Date |
2006-09-23 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
rnuquist |
Date |
2006-09-23 |
Time |
14:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-10-17 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-10-17 |
Time |
15:26 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-10-17 |
Time |
15:22 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-09-01 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-09-01 |
Time |
09:12 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-09-01 |
Time |
09:12 |
Sent To |
M |
|
Notes |
2006-09-01 00:00:00 | | | | | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} THERE MUST BE A DISCONNECT FROM THE | | GENERATOR WHERE THE CONDUCTORS ENTER THE | | BUILDING. IF ALL DISCONNECTS CANNOT BE | | GROUPED PER 230.72, SEE THAT ALL | | ARTICLES FROM 225.31 THROUGH 225.39, ARE | | COMPLIED WITH. | | | | 2} 700.15 LOADS ON EMERGENCY BRANCH | | CIRCUITS. | | NO APPLIANCES AND NO LAMPS, OTHER THAN | | THOSE SPECIFIED AS REQUIRED FOR | | EMERGENCY USE, SHALL BE SUPPLIED BY | | EMERGENCY LIGHTING CIRCUITS. PROVIDE A | | PANEL SCHEDULE FOR THE | | EMERGENCY/GENERATOR PANEL. | | | | 3} THE PERSON TAKING RESPONSIBILITY FOR | | THE PLAN/DRAWINGS, SHALL PRINT AND SIGN | | THEIR NAME ON THE SHEETS THEY DRAW. | | PLEASE DO THIS PRIOR TO RESUBMITTING. | | | | 4} PLEASE LOCATE ALL SERVICE EQUIPMENT | | ON THE PLAN, METER ENCLOSURE, | | DISCONNECTS AND PANELS, SO THAT | | COMPLIANCE WITH ARTICLES 225 AND 230 CAN | | BE REVIEWED. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2006-09-06 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-09-06 |
Time |
13:42 |
Rev Time |
0.15 |
Received By |
mperson |
Date |
2006-09-06 |
Time |
13:42 |
Sent To |
B |
|
Notes |
2006-09-06 00:00:00 | CONTRACTOR INFORMATION | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | BEFORE FINAL GEN/RES INSPECTION. | | | | ******IMPROTANT INFORMATION****** | | AS OF 8/25/06 GENERATOR (GEN/RES AND | | GEN/COM) PERMIT APPLICATIONS SHALL NOT | | BE ACCEPTED UNLESS THE ELECTRICAL INFOR- | | MATION AND GAS (OR DIESEL) INFORMATION | | IS ALL SUBMITTED AT THE SAME TIME. THE | | GENERATOR, ELECTRICAL AND GAS/DIESEL IN- | | FORMATION WILL BE ROUTED TOGETHER. THIS | | WILL ENSURE THAT ALL OF THE INFORMATION | | (PARTICULARLY THE MANUFACTURER'S SPECI- | | FICATIONS AND INSTALLATION INSTRUCTIONS) | | ARE AVAILABLE TO ALL PLAN REVIEWERS. | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-01-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-18 |
Time |
10:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-18 |
Time |
10:49 |
Sent To |
M |
|
Notes |
2007-01-18 10:49:35 | TO "M" BOX/RESUB--NO SPAMP ON PLANS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-01-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-10 |
Time |
11:24 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-10 |
Time |
11:24 |
Sent To |
Z |
|
Notes |
2007-01-10 11:24:33 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-10-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-14 |
Time |
16:18 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-14 |
Time |
16:18 |
Sent To |
E |
|
Notes |
2006-10-14 16:18:39 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-10-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-06 |
Time |
14:10 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-06 |
Time |
14:10 |
Sent To |
Z |
|
Notes |
2006-10-06 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-08-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-21 |
Time |
09:57 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-21 |
Time |
09:57 |
Sent To |
E |
|
Notes |
2006-08-21 00:00:00 | TO "GEN-RES" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-09-23 |
|
|
Cont ID |
|
Sent By |
rnuquist |
Date |
2006-09-23 |
Time |
14:33 |
Rev Time |
0.00 |
Received By |
rnuquist |
Date |
2006-08-11 |
Time |
17:55 |
Sent To |
|
|
Notes |
2006-08-11 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2007-01-18 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-01-18 |
Time |
12:23 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2007-01-18 |
Time |
12:23 |
Sent To |
B |
|
Notes |
2007-01-18 12:24:28 | NEW PAGES SUBMITTED (RE-STAMP). |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2006-10-18 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-10-18 |
Time |
13:49 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2006-10-18 |
Time |
13:49 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-09-05 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-09-05 |
Time |
15:54 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2006-09-05 |
Time |
15:54 |
Sent To |
G |
|
Notes |
2006-09-05 00:00:00 | *** DENIED *** | | 1) SEE ZONING REVIEW NOTES. | | | | 2) ALSO SHOW ON SURVEY LOCATION OF | | UNDER-GROUND PROPANE TANK (NOTE TANK | | MUST BE A MINIMUM OF 10 FT. FROM | | GENERATOR). | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2007-01-16 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2007-01-16 |
Time |
11:23 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2007-01-16 |
Time |
11:23 |
Sent To |
I |
|
Notes |
2007-01-16 11:24:20 | NOTE: THE PROPOSED GENERATOR WILL NOT PROJECT INTO THE | | REQUIRED REAR SETBACK. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2006-10-13 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2006-10-13 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2006-10-13 |
Time |
10:10 |
Sent To |
|
|
Notes |
2006-10-13 10:13:12 | FAILED | | | | COMMENTS FROM AUG. 18 ZONING REVIEW NOT ADDRESSED. | | | | ADDITIONALLY, THE LOCATION OF THE PROPOSED GENERATOR, | | WITH SETBACK DIMENSIONS SHALL BE SHOWN ON THE NEW | | SURVEY. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-08-18 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-08-18 |
Time |
15:44 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-08-18 |
Time |
15:44 |
Sent To |
I |
|
Notes |
2006-08-18 00:00:00 | DENIED, | | 1. NEED TO PROVIDE A CURRENT SURVEY, | | SHOWING ALL THAT'S LOCATED WITHIN THE | | PROPERTY. SURVEY MUST PROVIDE THE | | SETBACKS OF THE STRUCTURE FROM PROPERTY | | LINE (FRONT/SIDES/REAR) | | 2. SURVEY MUST SHOW THE EXISTING SHED | | AND SETBACKS. | | 3. NEED TO PROVIDE THE DISTANCE OF THE | | PROPOSED GENERATOR FROM THE PROPERTY | | LINE. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|