Plan Review Stops For Permit 06080306 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-10-04 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-10-04 |
Time |
14:44 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-10-04 |
Time |
14:44 |
Sent To |
|
|
Notes |
2006-10-04 00:00:00 | BUILDING REVIEW OK.SEE ELECTRICAL | | REVIEW COMMENTS THAT NEED TO BE | | ADDRESSED PRIOR TO ISSUING OF THE | | PERMIT. | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-08-16 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-08-16 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-08-16 |
Time |
16:30 |
Sent To |
|
|
Notes |
2006-08-16 00:00:00 | DENIED | | | | 1. A DESIGN PROFESSIONAL OR AN OWNER | | MUST ELECT ONE OR A COMBINATION OF | | LEVELS OF ALTERATION PURSUANT TO | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | SHOW HOW PLANS WILL COMPLY WITH THE | | SECTION(S) SELECTED.2004 FBC EXISTING | | BUILDING 301.5 | | | | 2.DOORS OPENING INTO THE PATH OF | | EGRESS TRAVEL SHALL NOT REDUCE THE | | REQUIRED WIDTH TO LESS THAN ONE-HALF | | DURING THE COURSE OF THE SWING. WHEN | | FULLY OPEN, THE DOOR SHALL NOT PROJECT | | MORE THAN 7 INCHES INTO THE REQUIRED | | WIDTH.FBC 1005.2 | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | OLD PAGES FOR REFERENCE . A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET | | OR SPECIFICATION PAGE WHERE THE CHANGES | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | ART LANGE | | CONSTRUCTION SERVICES DEPARTMENT | | BUILDING PLANS EXAMINER | | 561-805-6672 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-09-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-09-24 |
Time |
17:11 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-09-24 |
Time |
17:04 |
Sent To |
|
|
Notes |
2006-09-24 00:00:00 | *** UNSAT *** | | | | 1) NOTE: PLEASE KNOW, IT HAS BEEN | | CONFIRMED WITH TEH STATE'S LEGAL COUNSEL | | TO THE BOARD OF ARCHITECTS, AS PER FS | | 481.223(1)(A), 481.229(1)(C), PLANS MUST | | BE DONE BY AN ARCHITECT AT A MINIMUM. | | A "DESIGN" OR "DRAFTING" FIRM MAY NOT DO | | PLANS UNLESS DIRECTLY "EMPLOYED" BY AN | | ARCHITECT OR ENGINEER. WHICH WOULD MEAN | | EMPLOYMENT WITH W-2'A WORKER'S COMP ETC. | | THIS OFFICE HAS GIVEN NOTICE TO A&J | | TECHNOLOGIES THAT THIS IS NOT PERMITTED. | | PLEASE SEE FS 481.229 AS NOTED ABOVE, | | MAY NOT DO COMMERICAL PLANS FOR | | ARCHITECTURE NO MATTER THE VALUE. | | | | ** PLEASE ADDRESS. | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-08-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-16 |
Time |
20:20 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-08-16 |
Time |
20:12 |
Sent To |
|
|
Notes |
2006-08-16 00:00:00 | *** UNSAT *** | | | | 1) NOTE: PLEASE KNOW PLANS MUST CONTAIN | | RESPONSIBILITY TAKEN BY THE DESIGN | | PROFESSIONAL. "DRAWN BY; PRINTED NAME | | AND SIGNATURE" ETC. | | FBC 106.1.2 | | | | 2) NOTE: PLEASE INDICATE NEW CIRCUITING | | ON PLANS AND CORRELATE WITH THE | | SUBMITTED PANEL SCHEDULE. | | 408.4, 240.4, 310.16 | | | | 3) NOTE: PLEASE DECLARE WHAT | | CHEMICALS/USE WILL BE IN THE "MIXING | | ROOM" AS SHOWN. WILL THIS ROOM CONTAIN | | QUANITIES OF ANY FLAMMABLE LIQUIDS FOR | | MIXING ETC? | | NFPA-30,30B | | SEE FIRE REVIEW COMMENTS. | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2006-10-18 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-10-18 |
Time |
09:38 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-10-18 |
Time |
09:38 |
Sent To |
|
|
Notes |
2006-10-18 09:42:11 | ***DENIED*** | | | | 1) COMMENT (2) FROM LAST FIRE REVIEW REQUESTED | | ADDITIONAL INFORMATION REGARDING PROPOSED MATERIAL FOR | | MIXING ROOM. NO RESPONSE COULD BE FOUND WITH | | RESUBMITTAL. | | | | 2) PLEASE SEE ELECTRICAL REVIEW COMMENTS REGARDING | | REQUIREMENTS. | | | | | | MIKE WENNERGREN, ASSISTANT FIRE MARSHAL | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2006-08-25 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-08-25 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-08-25 |
Time |
15:39 |
Sent To |
|
|
Notes |
2006-08-25 00:00:00 | ***DENIED*** | | | | 1) PLEASE SHOW LOCATION OF 2A-10B,C | | RATED FIRE EXTINGUISHER(S). | | | | 2) PLEASE CLARIFY THE USE OF THE NEW | | MIXING ROOM. NOTE (1) ON SHT 1.1 | | REFERENCES MIXING PAINT. PLEASE INDICATE | | MATERIALS AND OR CHEMICALS THAT WILL BE | | USED IN REFERENCED ROOM. | | | | 3) IN ADDITION TO APPLICABE BUILDING | | CODES, LIFE SAFETY SHALL COMPLY WITH | | NFPA 101, 2003 EDITION. | | | | 4) SEPARATE SHOP DRAWINGS AND PERMIT MAY | | BE REQUIRED FOR FIRE SPRINKLER REMODEL. | | PLEASE INDICATE HOW EXISTING FIRE | | SPRINKLER SYSTEM WILL BE IMPACTED. | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-09-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-22 |
Time |
15:24 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-22 |
Time |
15:24 |
Sent To |
|
|
Notes |
2006-09-23 00:00:00 | TO "BOB"#13 | 2006-09-22 00:00:00 | WAITING FOR "BOB" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-08-26 |
|
|
Cont ID |
|
Sent By |
mmiller |
Date |
2006-08-26 |
Time |
08:37 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-08-04 |
Time |
13:47 |
Sent To |
|
|
Notes |
2006-08-16 00:00:00 | TO "BOB"#2 | 2006-08-08 00:00:00 | 8/8/06-WAITING FOR "BOB" | 2006-08-04 00:00:00 | SENT "E" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2006-10-18 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-10-18 |
Time |
15:58 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2006-10-18 |
Time |
15:58 |
Sent To |
|
|
Notes |
2006-10-18 16:03:19 | *** DENIED *** | | 1) MECHANICAL PAGE M-3 WAS NOT WITH REVISED PLANS, IF | | YOU WANT TO SUBMIT THE PREVIOUS APPROVED STAMPED COPYS | | THEN YOU NEED TO SUBMIT BOLTH COPYS. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-10-18 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-08-17 |
Time |
14:14 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2006-08-17 |
Time |
14:13 |
Sent To |
|
|
Notes |
2006-08-17 00:00:00 | *** PROVISO *** | | 1) IF MIXING ROOM WILL HOUSE ANY NOXIOUS | | GASES, FUMES, OR ODERS THEN RETURN AIR | | MAY NOT GO BACK TO THE AIR HANDLER UNIT, | | BUT MUST BE EXHAUSTED TO THE OUTDOORS, | | PER 2004 FBC/M 502.1.3 AND 502.1.4 . | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2006-10-21 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-10-21 |
Time |
14:07 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-10-21 |
Time |
14:06 |
Sent To |
|
|
Notes |
2006-10-21 14:10:18 | NO PAGE 3.1 IN NEW SET OF PLANS AND ONLY ONE COPY OF | | OLD SET OF PLANS PLEASE PROVIDE TWO SETS OF PAGE 3.1 | | WITH NEW SET OF PLANS. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2006-08-26 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-08-26 |
Time |
08:37 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-08-26 |
Time |
08:37 |
Sent To |
|
|
Notes |
|
|