Plan Review Stops For Permit 06080288 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2007-03-20 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2007-03-20 |
Time |
07:03 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2007-03-20 |
Time |
07:02 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-08-17 |
|
|
Cont ID |
|
Sent By |
rmcdouga |
Date |
2006-08-17 |
Time |
07:52 |
Rev Time |
0.00 |
Received By |
rmcdouga |
Date |
2006-08-17 |
Time |
07:05 |
Sent To |
|
|
Notes |
2006-08-17 00:00:00 | BUILDING DENIED | | | | 1)A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT MUST BE SUBMITTED BEFORE A | | PERMIT CAN BE ISSUED. | | | | 2) ADDRESS COMMENTS FROM OTHER REVIEWS. | | | | ROBERT MCDOUGAL | | BLDG. PLAN REVIEW | | (561)805-6714 | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2007-03-05 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-03-05 |
Time |
09:06 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-03-05 |
Time |
08:45 |
Sent To |
|
|
Notes |
2007-03-05 09:06:24 | STAMPED REVISED SHEETS AND SPECS FOR PUMP. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-08-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-08-16 |
Time |
19:56 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-08-16 |
Time |
19:50 |
Sent To |
|
|
Notes |
2006-08-16 00:00:00 | * UNSAT * | | | | 1) NOTE: PLEASE BE SURE THE PLANS | | REFLECT THE FOLLWOIGN CODES AT A MIN. | | NFPA-70 2002, NFPA-30A 2003. | | | | 2) NOTE: PLEASE PROVIDE A LAYOUT SHWOIGN | | THE CLASS LOCATIONS AS SPECIFIED IN NEC | | ART 514. | | | | 3) NOTE: PLEASE SHOW ALL ELECTRICAL | | EQUIPMENT ON ELECTRICAL SITE PLAN AS | | SHOWN ON RISER DIAGRAM. | | FBC 106.1.2, NEC 514 | | | | 4) NOTE: PLEASE PROVIDE MANUFACTURES | | SPECS/CUT SHEETS ON EQUIPMENT /FUEL | | PUMPS, TANKS ETC. PLEASE SEE COMMENTS | | FROM OTHER TRADES WHICH MAY ALSO REQUIRE | | TO REVIEW SUCH ITEMS. | | PLEASE BE SURE ALL ARE LISTED BY A NRTL. | | 110.3,90.7 | | FBC 106.1.2 | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2007-03-08 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2007-03-08 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2007-03-08 |
Time |
14:54 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2006-09-15 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-09-15 |
Time |
15:16 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-09-15 |
Time |
15:16 |
Sent To |
|
|
Notes |
2006-09-15 00:00:00 | ***DENIED*** | | | | 1) PRODUCT APPROVALS WILL BE REQUIRED | | FOR THE PROPOSED FUEL TANKS. INFORMATION | | REGARDING THE CONSTRUCTION, FIRE RATING, | | DOCUMENTED LISTINGS OR APPROVALS FROM | | THIRD PARTY TESTING AGENCIES, AND ANY | | APPLICABLE BALLISTIC TESTING RESULTS. | | | | 2) WHO WILL BE RESPONSIBLE FOR FUELING | | OPERATIONS? | | | | 3) IN ADDITION TO NO SMOKING AND STOP | | ENGINE, APPROPRIATE WARNING SIGNS SHALL | | INDICATE THE TYPE OF PORTABLE CONTAINERS | | THAT CAN BE FILLED, AND EMERGENCY SHUT | | OFF WORDING. | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2007-02-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-26 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-26 |
Time |
09:47 |
Sent To |
|
|
Notes |
2007-02-28 09:56:32 | TO "COMM" BD#18 | 2007-02-26 09:48:01 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-09-19 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-09-19 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2006-08-03 |
Time |
16:53 |
Sent To |
|
|
Notes |
2006-08-16 00:00:00 | TO "COMM" BD#25 | 2006-08-08 00:00:00 | 8/8/06-WAITING FOR "COMM" BD | 2006-08-03 00:00:00 | TO "E" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2007-03-19 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-03-19 |
Time |
10:56 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2007-03-19 |
Time |
10:56 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2006-09-19 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-09-19 |
Time |
14:01 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2006-09-19 |
Time |
14:01 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2006-08-25 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2006-08-25 |
Time |
07:23 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2006-08-25 |
Time |
07:23 |
Sent To |
|
|
Notes |
2006-08-25 00:00:00 | GASOLINE FUEL TANKS. - NO FUEL GAS | | REVIEW REQUIRED |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2007-03-04 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-03-04 |
Time |
13:52 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-03-04 |
Time |
13:52 |
Sent To |
|
|
Notes |
2007-03-04 13:53:00 | ***PROVISO*** | | | | 1) PARKING STRIPING SHALL BE IN ACCORDANCE WITH THE | | ATTACHED PAINTING DETAIL. | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | AT (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-09-05 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2006-09-05 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2006-09-05 |
Time |
15:41 |
Sent To |
|
|
Notes |
2006-09-05 00:00:00 | 9/5/06 ***FAILED*** | | | | 1) PER SECTION 94-482(C) OF THE CITY OF | | WPB ZONING AND LAND DEVELOPMENT | | REGULATIONS, OFF-STREET PARKING SHALL | | NOT BE REDUCED TO AN AMOUNT LESS THAN | | REQUIRED FOR THE BUILDING SQUARE | | FOOTAGE.PROPOSED TANKS APPEAR TO BE | | PLACED IN EXISTING PARKING. | | | | 2) A SURVEY OF THE EXISTING PROPERTY, | | DATED WITHIN THE LAST YEAR, SHALL BE | | PROVIDED. | | | | 3) PER SECTION 94-444(B) OF THE CITY OF | | WPB ZONING AND LAND DEVELOPMENT | | REGULATIONS, A FOUR-SIDED ENCLOSURE | | SHALL BE PROVIDED AS SCREENING. | | SCRRENING SHALL BE CONSTRUCTED OF BRICK, | | DECORATIVE CONCRETE, OTHER DECORATIVE | | MASONRY, OR COMPARABLY DURABLE WOOD AND | | STEEL.WALLS SHALL BE LANDSCAPED WITH | | SHRUBS AND HEDGES PLANTED AT TWO (2) | | FOOT INTERVALS. | | | | 4) LANDSCAPE PLAN, SIGNED AND SEALED BY | | A LICENSED LANDSCAPE ARCHITECT, SHALL BE | | PROVIDED INDICATING THE ABOVE-REFERENCED | | LANDSCAPE REQUIREMENTS. | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, | | SENIOR PLANNER, AT (561) 822-1435. |
|
|