Plan Review Details - Permit 06080074
Plan Review Stops For Permit 06080074
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2006-08-04 Cont ID  
Sent By lursu Date 2006-08-04 Time 08:46 Rev Time 0.00
Received By lursu Date 2006-08-02 Time 13:52 Sent To  
Notes
2006-08-04 00:00:00NEW SITE ADDRESS WAS AASSIGNED AS :1008
 PALM BEACH LAKES BLVD
2006-08-02 00:00:00SENT A COPY TO LILLY

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-12-10 Cont ID  
Sent By rnuquist Date 2006-12-10 Time 13:48 Rev Time 0.00
Received By rnuquist Date 2006-12-10 Time 13:48 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-08-11 Cont ID  
Sent By amorse Date 2006-08-11 Time 09:53 Rev Time 0.00
Received By amorse Date 2006-08-11 Time 09:24 Sent To PC
Notes
2006-08-11 00:00:00 
  
 DENIED
  
 1) BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561) 233-5025 FOR MORE
 INFORMATION
  
 2) THE CLAIMED VALUATION ON THE PERMIT
 APPLICATION IS LOW. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT
 COST EXCLUDING LAND VALUE. OUR VALUATION
 REFERENCE IS ICC (BVD), MARSHALL-SWIFT
 AND MEANS COST ANALYSIS SERVICES PER
 108.3 FBC*
  
 3) SUBMIT ENGINEERED TRUSS DRAWINGS THAT
 COMPLY WITH R802.10.1 FBC WITH PERMIT
 APPLICATION OR BEFORE INSTALLATION THAT
 HAVE BEEN REVIEWED AND APPROVED BY THE
 DESIGNER OF RECORD
  
 4) SUBMIT ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND
 DATED BY PREPARER AND OWNER/AGENT PRIOR
 TO SUBMITTAL
  
 5) AN ENGINEER PRACTICING THROUGH A DULY
 AUTHORIZED ENGINEERING BUSINESS SHALL
 INDICATE THEIR NAME AND LICENCE #, AS
 WELL AS THE NAME,ADDRESS AND CERTIFICATE
 OF AUTHORIZATION #ON EACH SHEET PER
 61G15-23.002 (2) FAC
  
  
  
  
  
  
  
  
  
  
 6) THE FOLLOWING PRODUCT APPROVALS
 REQUIRE CORRECTIONS
  
 A) SINGLE I/S ENTRY DOOR IS NOT APPROVED
 UNDER THE 2004 STATE PRODUCT
 APPROVALS.PLEASE SEE THAT THE ONLY STEEL
 EDGE DOOR DOES NOT HAVE IMPACT RATING
 BUT FIBERGLASS IMPACT DOORS ARE UNDER FL
 #4334
 B) NO PRODUCT APPROVALS WERE SUBMITTED
 FOR SLIDING GLASS DOOR
 C) PROVIDE UPDATED PRODUCT APPROVALS FOR
 ROOF COVERING (NOA HAS BEEN REVISED)
 D) "WINDLOAD 188" OVERHEAD GARAGE DOOR
 NOT LISTED ON STATE, WILL ACCEPT
 MIAMI-DADE FOR LOCAL PRODUCT APPROVAL
 E) PROVIDE PRODUCT APPROVALS FOR PRE
 CAST LINTELS AND WOOD CONNECTORS/ANCHOR
 (FOR CONNECTORS INDEX WITH FL#'S IS
 ADEQUATE SEE ATTACHED INDEX COVER)
 F) PROVIDE INSTALLATION SCHEDULE, KEY
 PLAN AND PRODUCT APPROVALS FOR IMPACT
 PROTECTIVE SHUTTERS
  
 7) REMOVE ALL NON USED PRODUCT APPROVAL
 FROM SUBMITTALS
  
 8) PROVIDE A SITE PLAN THAT SHOWS
 DRAINAGE IN COMPLIANCE WITH THE
 REQUIREMENTS OF R403.1
  
 9) ROOF SHEATHING NAIL PATTERN ON S-3 TO
 MEET THE REQUIREMENTS OF 2304.9.1 FBC
  
 10) PROVIDE CONNECTORS AND UPLIFT FOR
 PATIO ROOF TRUSSES ON S-2
  
 11) DOOR BETWEEN HOUSE AND GARAGE SHALL
 MEET THE REQUIREMENTS OF R309.1 FBC
  
 12) WINDOW ABOVE TUB DECK AND ANY
 GLAZING BETWEEN TUB AND SHOWER SHALL BE
 CONSIDERED GLAZING IN A HAZARDOUS
 LOCATION PER R308.4 PLEASE SPECIFY
 TEMPERED GLASS ON DRAWINGS
  
 13) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-11-30 Cont ID  
Sent By dpalmer Date 2006-11-30 Time 13:20 Rev Time 0.00
Received By dpalmer Date 2006-11-30 Time 13:20 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-08-04 Cont ID  
Sent By dpalmer Date 2006-08-04 Time 07:48 Rev Time 0.00
Received By dpalmer Date 2006-08-04 Time 07:04 Sent To M
Notes
2006-08-04 00:00:00**********UNSAT ***********
  
 1) NOTE: PLEASE CLARIFY UNDERGROUND
 SEC'S TO FPL. IF THESE ARE INSTALLED BY
 FPL , THEN PLEASE DO NOT INDICATE THE
 CONDUCTOR SIZES, AS THESE WILL NOT
 CORRELATE WITH FPL.
 PLEASE ALSO VERIFY THE DOWNSIZING OF THE
 NEURTRAL CONDUCTOR TO A #3.
 PLEASE PROVIDE NEUTRAL LOAD CALCULATION
 OR FULL SIZE NEUTRAL.
 220.22, 310.15B6
  
 2) NOTE: PLEASE SHOW CONDUIT SIZE FOR
 THE UNDERGROUND AND ALSO THE CONDUIT TO
 INSIDE PANEL. UNABLE TO VERIFY AT THIS
 TIME.
 FBC 106.1.2
  
 3) NOTE: PLEASE SEE 210.52 AS THERE ARE
 SOME RECEPTS MISSING . SEE REDLINED
 PLANS.
 PLEASE SEE AREA OF WALL OFF KITCHEN AND
 WHAT APPEARS TO BE THE MASTER BEDRM.
  
 4) NOTE: PLEASE SEE MISSING PENINSULAR
 GFI RECEPT. 210.52C3,210.8A6
  
 5) NOTE: PLEASE PROVIDE ALL ROOM AND
 AREA DESIGNATIONS ON PLANS AND CORRELATE
 WITH THE PANEL SCHEDULE.
 PLEASE SEE THAT ALL CIRCUITS ON PANEL
 SCHEDULE SHALL BE SPECIFIC TO ROOMS AND
 AREAS.
 IE; LIVING RM RECEPTS, BEDRM #2
 LTS/RECEPTS, HALL LTS ETC ETC.
 408.4 FBC 106.1.2
 **IT IS KNOWN THAT CIRCUITING DURING
 CONSTRUCTION WILL CHANGE AND THIS CAN EB
 REVISED AT A LATER DATE.
  
 6) NOTE: PLEASE SEE ONLY TWO CIRCUITS
 ARE BEIGN SHOWNWITH ARC FAULT
 PROTECTION FOR ALL BEDRMS LTS, RECEPTS
 AND SD'S. PLEASE KNOW, THE CODE HAS
 CHANGED FROM PREVIOUSLY SUBMITTED PLANS
 UNDER THIS PROJECT TO REQUIRE ARC FAULT
 PROTECTION FOR ALL OUTLETS IN BEDRMS.
 PLEASE BE SURE TO REVISE AS THE LOAD ON
 THESE ONLY TWO CIRCUITS SEEM TO EXCEED
 RATINGS.
 210.12B(2002) NEC. 210.52,220
  
 7)NOTE: PLEASE SEE MISSING THE REQUIRED
 DEDICATED BATH(S) CIRCUIT(S).
 210.11C3, SHALL BE 20A AND #12.
 NO BATH(S) LISTED.
  
 8) NOTE: PLEASE BE SURE HE PLANS PROVIDE
 THE FOLLOWING MINIMUM CODES AS ADOPTED
 FOR DESIGN AND FS/FBC 2004
 2002 NFPA-70, 2002 NFPA-72, 2003
 NFPA-101.
  
 9) NOTE: PLEASE SEE PLANS INDICATE THE
 PANEL LOCATED IN GARAGE, YET PANEL
 MENTIONS THIS IN HALL/UTILITY.
  
 10) NOTE: PLEASE SEE MIN EGRESS LIGHTING
 IS REQUIRED FOR WHAT APPEARS TO BE
 DINGIN AND LIV RM FOR EGRESS. SHOWS ONLY
 A JUNCTION BOX FOR FUTURE FAN. PLEASE
 KNOW, THIS CAN BE EITHER PROVIDED BY THE
 SWITCHING OF A RECEPT OR A LT FIXTURE OF
 SOME TYPE WHICH SHALL BE PROIVIDED.
 210.70, LS101 7.8
  
 11) NOTE: PLEASE SEE PLANS SHOWS A METER
 AND A MAIN DISCONNECT ON THE OUTSIDE. IF
 THIS IS THE CASE, PLEASE REVISE RISER TO
 INCLUDE THIS MAIN AND ALSO INCLUDE
 EQUIPMENT GROUNDING CONDUCTORS AS
 REQUIRED.
 250.24B, 250.122
 106.1.2
  
 12) NOTE: PLEASE SEE SURVEY PROVIDED IN
 PACKAGE IS REQUIRED TO CONTAIN AN
 ORIGINAL SIAGNAURE IN ORDER FOR SURVEY
 TO BE VALID. PLEASE SEE FAC 61G15-17, FS
 472.025
  
 13) NOTE: PLEASE SEE MISSING THE DINING
 ROOM CIRCUITS ON ONE OR MORE OF THE SM
 APPL CIRCUITS. 210.11C1,220.16
  
 14) NOTE: PLEASE SEE 210.4B
 PLEASE SEE DISHWASHER/DISP SEEMS TO BE
 FED TO THE SAME RECEPT, REQUIRES A
 2-POLE BRKR.
  
 ** IMPORTANT **
 BEFORE RESUBMITTING PLANS ONCE ALL
 REVIEWS ARE COMPLETED. PLEASE BE SURE TO
 COMPLETELY REMOVE ALL OLD/VOIDED SHEETS
 AND ONLY INSERT THE NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND
 STAMPING.
 ONLY ONE COPY OF THE OLD SHEETS SHOULD
 BE SUBMITTED FOR REFERENCE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-11-29 Cont ID  
Sent By mmiller Date 2006-11-29 Time 17:17 Rev Time 0.00
Received By mmiller Date 2006-11-29 Time 17:17 Sent To E
Notes
2006-11-29 17:18:15SENT TO DEWEY PALMER'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-11-21 Cont ID  
Sent By adarroug Date 2006-11-21 Time 11:24 Rev Time 0.00
Received By adarroug Date 2006-11-21 Time 11:24 Sent To Z
Notes
2006-11-21 11:24:58TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-08-11 Time   Rev Time 0.00
Received By adarroug Date 2006-08-02 Time 13:55 Sent To  
Notes
2006-08-02 00:00:00SENT TO"SFR/"Z"

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-08-07 Cont ID  
Sent By tgordon Date 2006-08-07 Time 14:23 Rev Time 0.15
Received By tgordon Date 2006-08-07 Time 14:23 Sent To P
Notes
2006-08-07 00:00:00NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-12-01 Cont ID  
Sent By mperson Date 2006-12-01 Time 15:24 Rev Time 0.33
Received By mperson Date 2006-12-01 Time 15:24 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-08-09 Cont ID  
Sent By mperson Date 2006-08-09 Time 08:13 Rev Time 0.45
Received By mperson Date 2006-08-09 Time 08:13 Sent To B
Notes
2006-08-09 00:00:00****** DENIED******
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 THE FOLLOWING INFORMATION IS REQUIRED
 FOR PLUMBING PLAN REVIEW ON THE SANITARY
 PLUMBING RISER DIAGRAM ON SHEET A-4.1,
 DETAIL #7. (NOTE: THE FOLLOWING
 CORRECTIONS ARE IN RED INK ON SHEET
 A-4.1 DETAIL #7 FOR REFERENCE FOR
 RESUBMITTAL.)
  
 1. PER FBC-2004, CHAPTER 1, SECTION
 106.3.5.4 RESIDENTIAL (ONE AND TWO
 FAMILY) SUBMIT A PLUMBING SANITARY
 ISOMETRIC RISER DIAGRAM INDICATING ALL
 WASTE, VENTS, TRAPS WITH SIZES, AND
 CLEANOUT LOCATIONS.(NOTE: 2ND FLOOR
 LAUNDRY TRAY IN ROOM #09 MISSING AND NOT
 ALL FIXTURE TRAPS SIZED.)
 2. PER FBC-2004, PLUMBING, SECTION 909.1
 WET VENT PERMITTED: ONLY THE FIXTURES
 WITHIN THE BATHROOM GROUPS SHALL CONNECT
 TO THE WET-VENTED HORIZONTAL BRANCH
 DRAIN. ANY ADDITIONAL FIXTURES SHALL
 DISCHARGE DOWNSTREAM OF THE WET VENT.
 (NOTE: THE 1ST FLOOR POWDER ROOM #04 AND
 THE 2ND FLOOR LAUNDRY ROOM #09 SANITARY
 ARE PIPED WRONG.)
 3. PER FBC-2004 PLUMBING THE FOLLOWING
 NEEDS TO BE CORRECTED ON THE WASHING
 MACHINE.
 (A) 406.3 WASTE CONNECTIONS.THE TRAP AND
 FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES
 WASHER SHALL BE A MINIMUM OF 2 INCHES
 (51MM) IN DIAMETER. THE AUTOMATIC
 CLOTHES WASHER FIXTURE DRAIN SHALL
 CONNECT TO A BRANCH DRAIN OR DRAINAGE
 STACK A MINIMUM OF 3 INCHES (76MM) IN
 DIAMETER. (NOTE: WASTE STACK SIZED
 WRONG.)
 (B) 802.4 STANDPIPES.STANDPIPES SHALL BE
 INDIVIDUALLY TRAPPED. STANDPIPES SHALL
 EXTEND A MINIMUM OF 18 INCHES (457MM)
 AND A MAXIMUM OF 42 INCHES (1066MM)
 ABOVE THE TRAP WEIR. ACCESS SHALL BE
 PROVIDED TO ALL STANDPIPES AND DRAINS
 FOR RODDING. (NOTE: PLEASE INDICATE
 STANDPIPE ON DRAWING.)
 4. PER FBC--2004 PLUMBING THE FOLLOWING
 NEEDS TO BE INDICATED ON CLEANOUTS.
 (A) 708.3.4 BASE OF STACK. A CLEANOUT
 SHALL BE PROVIDED AT THE BASE OF EACH
 WASTE OR SOIL STACK. PLEASE INDICATE ON
 DRAWING.
 5. PER FBC-2004 PLUMBING, SECTION
 802.1.6 DOMESTIC DISHWASHING MACHINES:
 SHALL DISCHARGE INTO A WYE-BRANCH
 FITTING ON THE TAILPIECE OF THE KITCHEN
 SINK OR THE DISHWASHING CONNECTION OF A
 FOOD WASTE GRINDER. PLEASE REFERENCE
 ISOMETRIC DRAWING.
 6. PER FBC-2004 PLUMBING, SECTION 905.5
 HEIGHT ABOVE FIXTURES: A CONECTION
 BETWEEN A VENT STACK OR STACK VENT SHALL
 BE MADE AT LEAST 6" INCHES ABOVE THE
 FLOOD LEVEL RIM OF THE FIXTURE SERVED BY
 THE VENT. (NOTE: VENT FOR 1ST FLOOR
 POWDER ROOM #04 WRONG.)
  
 **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN
 RESUBMITTING, PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2006-12-11 Cont ID  
Sent By mmclean Date 2006-12-11 Time 11:11 Rev Time 0.00
Received By mmclean Date 2006-12-11 Time 11:11 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status F Date 2006-11-26 Cont ID  
Sent By mmclean Date 2006-11-26 Time 22:46 Rev Time 0.00
Received By mmclean Date 2006-11-26 Time 22:46 Sent To I
Notes
2006-11-26 22:47:28DENIED, 2ND REQUEST.
 1. THE PROPOSED DRIVEWAY HAS EXCEED THE ZONING
 REQUIREMENT FOR LANDSCAPE WITHIN THE 25FT FRONT
 SETBACK.
 2. MUST REDUCE THE PROPOSED TO 12.5FT WIDE TO MEET THE
 312.5 SQ FT THAT IS ALLOWED.
 3. PLEASE SUBMIT TWO COPY OF SURVEY SHOWING THE THE
 CHANGES.
  
 NOTE:MUST MAINTAIN 1000SQ FT OR 75% OF LANDSCAPE,
 WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK.
  
 4. PREVIOUS COMMENTS WERE NOT ADDRESS AND INFORMATION
 PROVIDED.
 5. PLEASE SHOW THE A/C UNIT ON THE TWO COPIES OF
 SURVEYS.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720

Review Stop Z ZONING
Rev No 1 Status F Date 2006-08-03 Cont ID  
Sent By mmclean Date 2006-08-03 Time 16:38 Rev Time 0.00
Received By mmclean Date 2006-08-03 Time 16:38 Sent To E
Notes
2006-08-03 00:00:00DENIED,
 1. THE PROPOSED DRIVEWAY HAS EXCEED THE
 ZONING REQUIREMENT FOR LANDSCAPE WITHIN
 THE 25FT FRONT SETBACK.
 2. MUST REDUCE THE PROPOSED TO 12.5FT
 WIDE TO MEET THE 312.5 SQ FT THAT IS
 ALLOWED.
 3. PLEASE SUBMIT TWO COPY OF SURVEY
 SHOWING THE THE CHANGES.
  
 NOTE:MUST MAINTAIN 1000SQ FT OR 75% OF
 LANDSCAPE, WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
  