Plan Review Details - Permit 06080071
Plan Review Stops For Permit 06080071
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-01-18 Cont ID  
Sent By rnuquist Date 2007-01-18 Time 18:11 Rev Time 0.00
Received By rnuquist Date 2007-01-18 Time 18:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-12-10 Cont ID  
Sent By rnuquist Date 2006-12-10 Time 11:19 Rev Time 0.00
Received By rnuquist Date 2006-12-10 Time 11:19 Sent To  
Notes
2006-12-10 11:21:40BUILDING REVIEW OK PENDING ITEM 1 ON FIRST REVIEW
 COMMENTS PROVIDE RECEIPT OF PAID IMPACT FEES

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-08-10 Cont ID  
Sent By amorse Date 2006-08-10 Time 10:59 Rev Time 0.00
Received By amorse Date 2006-08-10 Time 10:59 Sent To PC
Notes
2006-08-10 00:00:00 
  
 DENIED
  
 1) BEFORE A PERMIT TO CONSTRUCT, MAY
 BE ISSUED, IMPACT FEES MUST BE PAID TO
 PALM BEACH COUNTY. THE ACTUAL PERMIT
 SETS OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561) 233-5025 FOR MORE
 INFORMATION
  
 2) THE CLAIMED VALUATION ON THE PERMIT
 APPLICATION IS LOW. FOR PERMITTING
 PURPOSES, VALUATION OF BUILDINGS AND
 SYSTEMS SHALL BE THE TOTAL REPLACEMENT
 COST EXCLUDING LAND VALUE. OUR VALUATION
 REFERENCE IS ICC (BVD), MARSHALL-SWIFT
 AND MEANS COST ANALYSIS SERVICES PER
 108.3 FBC*
  
 3) SUBMIT ENGINEERED TRUSS DRAWINGS THAT
 COMPLY WITH R802.10.1 FBC WITH PERMIT
 APPLICATION OR BEFORE INSTALLATION THAT
 HAVE BEEN REVIEWED AND APPROVED BY THE
 DESIGNER OF RECORD
  
 4) SUBMIT ENERGY CALC'S PER 13-101.2.2
 FBC. BE SURE THAT THEY ARE SIGNED AND
 DATED BY PREPARER AND OWNER/AGENT PRIOR
 TO SUBMITTAL
  
 5) MAKE CORRECTIONS TO WIND DESIGN DATA
 AND DESIGN LOAD SHEDULE TO COMPLY WITH
 THE 2004 FBC AND APPLICABLE SECTIONS ON
 3.1
  
 6) CLARIFY PORCH SUPPORT DETAIL "D" IS
 THE SUPPORT IN THE CENTER OV\F EACH
 INDIVIDUAL BEAM SPAN OR THE CENTER OF
 THE 2 SPANS? IF IN LOCATION SHOWN NO
 FOUNDATIONS ARE PRESENT. IF NOT ARE THE
 BEAM SPANS FOR (2) 2X10 OF APPROX
 11'-10" OK?
  
 7) PROVIDE ATTACHMENT TYPE AND AMOUNT
 FOR HU210-2 BEAM HANGERS, MAY ALSO
 REQUIRE CONCEALED FLANGE TYPE ON CORNERS
  
 8) PROVIDE LINTEL SCHEDULE THAT COMPLIES
 WITH 2104.1.5 FBC
  
 9) THE FOLLOWING PRODUCT APPROVALS
 REQUIRE CORRECTIONS
  
 A) SINGLE AND DOUBLE O/S GLAZED ENTRY
 DOORS ARE NOT APPROVED UNDER THE 2004
 STATE PRODUCT APPROVALS.PLEASE SEE THAT
 THE ONLY STEEL EDGE DOOR THAT IS GLAZED
 DOES NOT HAVE IMPACT RATING BUT GLAZED
 FIBERGLASS IMPACT DOORS ARE UNDER FL
 #4334
 B) H-R MULLION PRODUCT APPROVALS ARE
 RE-COPIED TO MANY TIMES AND CANNOT BE
 READ PLEASE REPRINT
 C) GAF SHINGLES HAVE CORRECT STATE COVER
 SHEET BUT THE NOA HAS BEEN REVISED
 PLEASE SUBMIT NEW NOA
 D) STORAGE SHED HAS DOUBLE OPAQUE(NON
 GLAZED) DOORS PROVIDE PRODUCT APPROVALS
 E) PROVIDE PRODUCT APPROVALS FOR PRE
 CAST LINTELS AND WOOD CONNECTORS/ANCHOR
 (FOR CONNECTORS INDEX WITH FL#'S IS
 ADEQUATE SEE ATTACHED INDEX COVER)
  
 10) A RECORDED COPY OF THE NOTICE OF
 COMMENCEMENT IS REQUIRED PRIOR TO
 A PERMIT BEING ISSUED
  
 11) REMOVE ALL NON USED PRODUCT APPROVAL
 FROM SUBMITTALS
  
 12) ENGINEERS SHALL LEGIBLY INDICATE
 THEIR NAME, ADDRESS, AND LICENCE NUMBER
 ON EACH SHEET THAT BEARS THEIR SEAL PER
 61G15-23.002(2) (SEE PAGE 10.1)
  
 13) PROVIDE A SITE PLAN THAT SHOWS
 DRAINAGE IN COMPLIANCE WITH THE
 REQUIREMENTS OF R403.1
  
 14) CLARIFY FINISH ON THE GABLE ENDS
 STATES STUCCO BUT LOOKS LIKE SIDING, IF
 SIDING IS USED A PRODUCT APPROVAL WILL
 BE REQUIRED ALONG WITH A MOUNTING DETAIL
 TO BLOCK
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716
  
  
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-11-30 Cont ID  
Sent By dpalmer Date 2006-11-30 Time 13:43 Rev Time 0.00
Received By dpalmer Date 2006-11-30 Time 13:33 Sent To M
Notes
2006-11-30 13:44:12REDLINED/ REVISE BEFORE ROUGH.
  
 DISC DETAIL AND GROUNDING DETAIL ALONG WITH ANY OTHER
 REVISIONS BEFORE ROUGH. 225.31-225.39, AND 250.32

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-08-04 Cont ID  
Sent By dpalmer Date 2006-08-04 Time 20:24 Rev Time 0.00
Received By dpalmer Date 2006-08-04 Time 20:09 Sent To M
Notes
2006-08-04 00:00:00**********UNSAT ***********
  
 1) NOTE: PLEASE CLARIFY UNDERGROUND
 SEC'S TO FPL. IF THESE ARE INSTALLED BY
 FPL , THEN PLEASE DO NOT INDICATE THE
 CONDUCTOR SIZES, AS THESE WILL NOT
 CORRELATE WITH FPL.
 PLEASE ALSO VERIFY THE DOWNSIZING OF THE
 NEURTRAL CONDUCTOR TO A #3.
 PLEASE PROVIDE NEUTRAL LOAD CALCULATION
 OR FULL SIZE NEUTRAL.
 220.22, 310.15B6
  
 2) NOTE: PLEASE SHOW CONDUIT SIZE FOR
 THE UNDERGROUND AND ALSO THE CONDUIT TO
 INSIDE PANEL. UNABLE TO VERIFY AT THIS
 TIME.
 FBC 106.1.2
  
 3) NOTE: PLEASE SEE 210.52C1AS THERE
 ARE SOME RECEPTS MISSING . SEE REDLINED
 PLANS.
 PLEASE SEE AREAS OF COUNTER SPACE,
 PLEASE SEE LOCATED NEXT TO STOVE ETC.
  
 4) NOTE: PLEASE SEE MISSING ISLAND
 GFI RECEPT. 210.52C1-5,210.8A6
  
 5) NOTE: PLEASE SEE THAT ALL ROOM AND
 AREA DESIGNATIONS ON PLANS CORRELATE
 WITH THE PANEL SCHEDULE.
 PLEASE SEE THAT ALL CIRCUITS ON PANEL
 SCHEDULE SHALL BE SPECIFIC TO ROOMS AND
 AREAS.
 IE; LIVING RM RECEPTS, BEDRM #2
 LTS/RECEPTS, HALL LTS ETC ETC.
 408.4 FBC 106.1.2
 **IT IS KNOWN THAT CIRCUITING DURING
 CONSTRUCTION WILL CHANGE AND THIS CAN EB
 REVISED AT A LATER DATE.
  
 6) NOTE: PLEASE SEE ONLY TWO CIRCUITS
 ARE BEIGN SHOWNWITH ARC FAULT
 PROTECTION FOR ALL BEDRMS LTS, RECEPTS
 AND SD'S. PLEASE KNOW, THE CODE HAS
 CHANGED FROM PREVIOUSLY SUBMITTED PLANS
 UNDER THIS PROJECT TO REQUIRE ARC FAULT
 PROTECTION FOR ALL OUTLETS IN BEDRMS.
 PLEASE BE SURE TO REVISE AS THE LOAD ON
 THESE ONLY TWO CIRCUITS SEEM TO EXCEED
 RATINGS.
 210.12B(2002) NEC. 210.52,220
  
 7)NOTE: PLEASE SEE MISSING THE REQUIRED
 DEDICATED BATH(S) CIRCUIT(S).
 210.11C3, SHALL BE 20A AND #12.
 NO BATH(S) LISTED.
  
 8) NOTE: PLEASE BE SURE HE PLANS PROVIDE
 THE FOLLOWING MINIMUM CODES AS ADOPTED
 FOR DESIGN AND FS/FBC 2004
 2002 NFPA-70, 2002 NFPA-72, 2003
 NFPA-101.
  
 9) NOTE: PLEASE SEE PLANS INDICATE THE
 PANEL LOCATED INHALL ON PLANS AND
 PANEL SCHEDULE SAY HALL/UTILITY.??
 PLEASE SEE ELECTRICAL PLANS DO NOT SHOW
 THE SAME WALL AS SHOWN ON BUILDING
 PLANS.
 PLEASE ALSO CLARIFY THE MISSING CONTROL
 FOR LT(S) IN THE UTILITY RM. 210.70
  
 10) NOTE: PLEASE SEE "J-BOXES" SHOWN ON
 PLANS NEED TO BE NOTED FOR "FUTURE FAN
 BOXES' IF INDEED FOR FANS. PLEASE SEE
 314.47D
  
 11) NOTE: PLEASE SEE PLANS DO NOT SHOWN
 LOCATION OF SERVICE ON THE OUTSIDE OF
 HOUSE.
 106.1.2
  
 12) NOTE: PLEASE SEE SURVEY PROVIDED IN
 PACKAGE IS REQUIRED TO CONTAIN AN
 ORIGINAL SIAGNAURE IN ORDER FOR SURVEY
 TO BE VALID. PLEASE SEE FAC 61G15-17, FS
 472.025
  
 13) NOTE: PLEASE SEE MISSING THE DINING
 ROOM CIRCUITS ON ONE OR MORE OF THE SM
 APPL CIRCUITS. 210.11C1,220.16
  
 14) NOTE: PLEASE SEE DISHWASHER AND
 DISPOSAL SEEM TO BE SHARED TO THE SAME
 RECEPT, HOWEVER PLEASE SEE PANEL DOES
 NOT INDICATE A 2-POLE BREAKER. PLEASE
 SEE 210.4B
  
 15) NOTE: PLEASE SEE MISSING DISCONNECT
 AND GROUNDING AT THE DETAACHED BLDG.
 PLEASE SHOW ON ELECTRICAL PLANS.
 PLEASE SEE 225.31-225.39, 250.32
  
 ** IMPORTANT **
 BEFORE RESUBMITTING PLANS ONCE ALL
 REVIEWS ARE COMPLETED. PLEASE BE SURE TO
 COMPLETELY REMOVE ALL OLD/VOIDED SHEETS
 AND ONLY INSERT THE NEW REVISED SHEETS
 INTO TWO COMPLETE SETS FOR REVIEW AND
 STAMPING.
 ONLY ONE COPY OF THE OLD SHEETS SHOULD
 BE SUBMITTED FOR REFERENCE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-08-29 Cont ID  
Sent By adarroug Date 2007-08-29 Time 11:43 Rev Time 0.00
Received By adarroug Date 2007-08-29 Time 11:43 Sent To M
Notes
2007-08-29 11:43:51TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-08-03 Cont ID  
Sent By adarroug Date 2007-08-03 Time 10:06 Rev Time 0.00
Received By adarroug Date 2007-08-03 Time 10:06 Sent To P
Notes
2007-08-03 10:06:39TO "JLEECH" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-01-03 Cont ID  
Sent By adarroug Date 2007-01-03 Time 10:23 Rev Time 0.00
Received By adarroug Date 2007-01-03 Time 10:23 Sent To B
Notes
2007-01-03 10:25:03TO "LMARTINEZ" DESK/SUBMITTAL

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-11-29 Cont ID  
Sent By mmiller Date 2006-11-29 Time 17:19 Rev Time 0.00
Received By mmiller Date 2006-11-29 Time 17:19 Sent To E
Notes
2006-11-29 17:19:30SENT TO DEWEY PALMER'S DESK

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-11-21 Cont ID  
Sent By adarroug Date 2006-11-21 Time 09:41 Rev Time 0.00
Received By adarroug Date 2006-11-21 Time 09:41 Sent To Z
Notes
2006-11-21 09:41:59TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-08-10 Time   Rev Time 0.00
Received By adarroug Date 2006-08-02 Time 14:00 Sent To  
Notes
2006-08-02 00:00:00TO "SFR" "Z"

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-09-10 Cont ID  
Sent By tgordon Date 2007-09-10 Time 08:51 Rev Time 0.20
Received By tgordon Date 2007-09-10 Time 08:51 Sent To  
Notes
2007-09-10 08:52:01REVISION TO MECH. PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-12-22 Cont ID  
Sent By tgordon Date 2006-11-30 Time 09:51 Rev Time 0.00
Received By tgordon Date 2006-11-30 Time 09:52 Sent To B
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-08-07 Cont ID  
Sent By tgordon Date 2006-08-07 Time 14:40 Rev Time 0.20
Received By tgordon Date 2006-08-07 Time 14:40 Sent To P
Notes
2006-08-07 00:00:00*** DENIED ***
 1) JOB ADDRESS MUST APPEAR ON ALL PAGES
 OF PLANS.
  
 2) MECHANICAL PLANS EQUIPMENT LIST SHOWS
 AHU IS A 10 SEER AND CONDENSER UNIT IS A
 12 SEER, PLEASE SHOW THE SEER OF THE
 SYSTEM ONLY. AND SHOW THE TOTAL BTU'S.
 AND SENSIBLE BTU'S. OF THE A/C SYSTEM.
  
 3) PLEASE SHOW ON MECH. PLANS THE SIZE
 OF THE RETURN AIR GRILL TO THE AIR
 HANDLER.
  
 4) RETURN AIR TRANSFER DUCTS TO
 BEDROOMS, THE GRILLS ARE TO SMALL FOR
 THE DUCTS.
  
 5) SUPPLY AIR DUCT TO SECOND FLOOR
 CLOSET #2 NEEDS TO BE SIZED.
  
 6) PLEASE EXPLAIN WHY A 7" SUPPLY AIR
 DUCT IS GOING TO THE SMALL CLOSET IN THE
 HALL.
  
 7) PLEASE SUBMIT MANUAL D CALCULATIONS
 FOR RESIDENTIAL DUCT DESIGN, PER 2004
 FBC/R M1601.1 AND FBC 13-610.1.ABC.1 .
  
 8) ENERGY CALCULATIONS NEED TO BE SIGNED
 BY OWNER/AGENT ALSO, PER 2004 FBC
 13-600.3.ABC.2
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 3 Status P Date 2007-08-07 Cont ID  
Sent By jleech Date 2007-08-07 Time 07:27 Rev Time 0.00
Received By jleech Date 2007-08-07 Time 07:27 Sent To  
Notes
2007-08-07 07:28:15REVISED RISER DIAGRAM OK

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-12-01 Cont ID  
Sent By mperson Date 2006-12-01 Time 15:39 Rev Time 0.33
Received By mperson Date 2006-12-01 Time 15:39 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-08-08 Cont ID  
Sent By mperson Date 2006-08-08 Time 14:05 Rev Time 0.45
Received By mperson Date 2006-08-08 Time 14:05 Sent To B
Notes
2006-08-08 00:00:00******DENIED******
 REFERENCE: FBC-2004 PLUMBING
  
 THE FOLLOWING INFORMATION IS REQUIRED
 FOR PLUMBING PLAN REVIEW ON THE SANITARY
 PLUMBING RISER DIAGRAM ON SHEET 8.1.
 NOTE: THE FOLLOWING CORRECTIONS ARE IN
 RED INK FOR REFERENCE FOR RESUBMITTAL
  
 1. PER FBC-2004, CHAPTER 1, SECTION
 106.3.5.4 RESIDENTIAL (ONE AND TWO
 FAMILY) SUBMIT A PLUMBING SANITARY
 ISOMETRIC RISER DIAGRAM INDICATING ALL
 WASTE, VENTS, TRAPS WITH SIZES, AND
 CLEANOUT LOCATIONS. (NOTE: TRAPS NOT
 SIZED AND DISHWASHER NOT INDICATED)
 2. PER FBC-2004 PLUMBING THE FOLLOWING
 NEEDS TO BE CORRECTED ON THE WASHING
 MACHINE.
 (A) 406.3 WASTE CONNECTIONS.THE TRAP AND
 FIXTURE DRAIN FOR AN AUTOMATIC CLOTHES
 WASHER SHALL BE A MINIMUM OF 2 INCHES
 (51MM) IN DIAMETER. THE AUTOMATIC
 CLOTHES WASHER FIXTURE DRAIN SHALL
 CONNECT TO A BRANCH DRAIN OR DRAINAGE
 STACK A MINIMUM OF 3 INCHES (76MM) IN
 DIAMETER.(NOTE: BRANCH DRAIN SIZED
 WRONG)
 (B) 802.4 STANDPIPES.STANDPIPES SHALL BE
 INDIVIDUALLY TRAPPED. STANDPIPES SHALL
 EXTEND A MINIMUM OF 18 INCHES (457MM)
 AND A MAXIMUM OF 42 INCHES (1066MM)
 ABOVE THE TRAP WEIR. ACCESS SHALL BE
 PROVIDED TO ALL STANDPIPES AND DRAINS
 FOR RODDING (NOTE: PLEASE INDICATE
 STANDPIPE ON DRAWING.)
 3. PER FBC-2004 PLUMBING THE FOLLOWING
 NEEDS TO BE INDICATED ON CLEANOUTS.
 (A) 708.3.4 BASE OF STACK. A CLEANOUT
 SHALL BE PROVIDED AT THE BASE OF EACH
 WASTE OR SOIL STACK
 (B) 708.3.5 BUILDING DRAIN AND BUILDING
 SEWER JUNCTION. THERE SHALL BE A
 CLEANOUT NEAR THE JUNCTION OF THE
 BUILDING DRAIN AND THE BUILDING SEWER.
 (C) 708.7 MINIMUM SIZE. CLEANOUTS SHALL
 BE THE SAME NOMINAL SIZE AS THE PIPE
 THEY SERVE UP TO 4 INCHES (102MM)
 (D) 708.9 ACCESS. ACCESS SHALL BE
 PROVIDED TO ALL CLEANOUTS.
  
 **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN
 RESUBMITTING, PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY. NOTE: ONLY ONE CORRECTED DRAWING
 IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  
  
  
  

Review Stop Z ZONING
Rev No 3 Status P Date 2006-12-21 Cont ID  
Sent By mmclean Date 2006-12-21 Time 13:52 Rev Time 0.00
Received By mmclean Date 2006-12-21 Time 13:52 Sent To  
Notes
2006-12-21 13:55:38OK TO APPROVE PER ANGELLA JONES-VANN, DEPUTY PLANNING
 DIRECTOR.
  
 NOTE: THE PROPERTY LINE THAT PROJECTS INTO THE ROW
 SHALL NOT HAVE ANYTHING BUILDING WITHIN THAT PORTION OF
 THE LOT.
  
 NOTE: THE DISTANCE OF THE SHED FROM THE STRUCTURE AND
 COVERED PATIO SHALL BE A MINIMUM OF 6FT.

Review Stop Z ZONING
Rev No 2 Status F Date 2006-11-25 Cont ID  
Sent By mmclean Date 2006-11-25 Time 21:57 Rev Time 0.00
Received By mmclean Date 2006-11-25 Time 21:56 Sent To I
Notes
2006-11-26 22:05:28DENIED, 2ND REQUEST
 1. THE SURVEY PROVIDE DOES NOT SHOW THE FRONT PROPERTY
 CORRECTLY.IT SHOW THE PROPERTY LINE INTO THE STREET.
 2. MUST PROVIDE THE DIMENSION FOR THE PROPOSED DRIVEWAY
 & WALKWAY (LENGTH & WIDTH)
  
 NOTE: MUST MAINTAIN 1000SQ FT OR 75% OF LANDSCAPE,
 WHICHEVER IS LESS WITHIN THE FIRST 25FT FRONT SETBACK.
  
 3. THE SURVEY DOES NOT SHOW THE FRONT SETBACK OF THE
 PROPERTY. SF11. THE ORDINANCE APPROVED REQUIRES THAT
 THE
 HOUSE BE LOCATED 20FT FROM THE FRONT PROPERTY LINE (NOT
 FROM THE STREET) . SURVEY MUST SHOW THE SETBACK FOR THE
 FRONT/SIDE/REAR OF PROPERTY LINE.
 4. NEED PROVIDE THE DISTANCE OF THE COVERED PORCH &
 PROPOSED STORAGE BLDG.
 5. THE DRAINAGE PLAN CANNOT BE USED AS A SITEPLAN, IT
 DOES NOT PROVID THE DIMENSION OF THE LOT, ADDRESS OF
 THE PROPERTY AND SETBACKS OF THE PROPOSED STRUCTURE AND
 STORAGE BLDG. PLEASE CLAIFY.
 6. PLEASE SHOW THE LOCATION OF THE A/C ON TWO COPIES OF
 SURVEYS.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720
  
 720

Review Stop Z ZONING
Rev No 1 Status F Date 2006-08-04 Cont ID  
Sent By mmclean Date 2006-08-04 Time 17:32 Rev Time 0.00
Received By mmclean Date 2006-08-04 Time 17:32 Sent To E
Notes
2006-08-04 00:00:00DENIED,
 1. THE SURVEY PROVIDE DOES NOT SHOW THE
 FRONT PROPERTY CORRECTLY.IT SHOW THE
 PROPERTY LINE INTO THE STREET.
 2. MUST PROVIDE THE DIMENSION FOR THE
 PROPOSED DRIVEWAY & WALKWAY (LENGTH &
 WIDTH)
  
 NOTE: MUST MAINTAIN 1000SQ FT OR 75% OF
 LANDSCAPE, WHICHEVER IS LESS WITHIN THE
 FIRST 25FT FRONT SETBACK.
  
 3. THE SURVEY DOES NOT SHOW THE FRONT
 SETBACK OF THE PROPERTY. SF11. THE
 ORDINANCE APPROVED REQUIRES THAT THE
 HOUSE BE LOCATED 20FT FROM THE FRONT
 PROPERTY LINE (NOT FROM THE STREET)
 4. NEED PROVIDE THE DISTANCE OF THE
 COVERED PORCH & PROPOSED STORAGE BLDG.
  
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720