Plan Review Stops For Permit 06071830 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2006-08-18 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-08-18 |
Time |
09:48 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2006-08-18 |
Time |
09:48 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-10-12 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-10-12 |
Time |
11:20 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-10-12 |
Time |
11:04 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-09-28 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-09-28 |
Time |
17:49 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-09-28 |
Time |
17:45 |
Sent To |
M |
|
Notes |
2006-09-28 00:00:00 | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | SAME COMMENTS AS LAST REVIEW | | | | 1} PLEASE NOTE A DISCONNECT IS REQUIRED | | PER 225.31 AND 32. INDICATE LOCATION ON | | THE RISER AND SITE PLAN. THE TRANSFER | | SWITCH MAY NOT MEET THIS REQUIREMENT, | | SEE SPECS BEFORE SUBMITTING. SHOULD BE | | LOCATED WHERE THE JUNCTION BOX IS SHOWN. | | THIS DISCONNECT IS NOT REQUIRED TO HAVE | | OVERCURRENT PROTECTION. | | | | 2} SUBMIT A SITE PLAN AND LOCATE ALL | | THE SERVICE AND GENERATOR GEAR ON SAME | | SO THAT COMPLIANCE WITH 230.72 | | (GROUPING), 225.31-39 FOR THE | | DISCONNECTING MEANS REQUIREMENTS AND | | 250.32 FOR GROUNDING CAN BE REVIEWED. | | | | 3} PROVIDE A LOAD CALCULATION FOR THE | | LOAD INTENDED TO BE SERVED. 215.5. THE | | GENERATOR HAS A RATED OUTPUT OF 52.5 | | AMPS PER SPEC'S. THE CALCULATION | | REQUIRED IS FOR THE CIRCUITS IN THE 16 | | CIRCUIT GENERATOR PANEL. 702.5 CAPACITY | | AND RATING. | | AN OPTIONAL STANDBY SYSTEM SHALL HAVE | | ADEQUATE CAPACITY AND RATING FOR THE | | SUPPLY OF ALL EQUIPMENT INTENDED TO BE | | OPERATED AT ONE TIME. OPTIONAL STANDBY | | SYSTEM EQUIPMENT SHALL BE SUITABLE FOR | | THE MAXIMUM AVAILABLE FAULT CURRENT AT | | ITS TERMINALS. THE USER OF THE OPTIONAL | | STANDBY SYSTEM SHALL BE PERMITTED TO | | SELECT THE LOAD CONNECTED TO THE SYSTEM. | | | | 4} THE PERSON RESPONSIBLE FOR THE PLAN | | MUST PRINT AND SIGN THEIR NAME TO | | SAME.106.3.4.2 FBC, AS AMENDED. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-08-10 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-08-10 |
Time |
17:04 |
Rev Time |
1.00 |
Received By |
btrobaug |
Date |
2006-08-10 |
Time |
15:10 |
Sent To |
P |
|
Notes |
2006-08-09 00:00:00 | | | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} PLEASE NOTE A DISCONNECT IS REQUIRED | | PER 225.31 AND 32. INDICATE LOCATION ON | | THE RISER AND SITE PLAN. THE TRANSFER | | SWITCH MAY NOT MEET THIS REQUIREMENT, | | SEE SPECS BEFORE SUBMITTING. SHOULD BE | | LOCATED WHERE THE JUNCTION BOX IS SHOWN. | | THIS DISCONNECT IS NOT REQUIRED TO HAVE | | OVERCURRENT PROTECTION. | | | | 2} SUBMIT A SITE PLAN AND LOCATE ALL | | THE SERVICE AND GENERATOR GEAR ON SAME | | SO THAT COMPLIANCE WITH 230.72 | | (GROUPING), 225.31-39 FOR THE | | DISCONNECTING MEANS REQUIREMENTS AND | | 250.32 FOR GROUNDING CAN BE REVIEWED. | | | | 3} PROVIDE A LOAD CALCULATION FOR THE | | LOAD INTENDED TO BE SERVED. 215.5. THE | | GENERATOR HAS A RATED OUTPUT OF 52.5 | | AMPS PER SPEC'S. THE CALCULATION | | REQUIRED IS FOR THE CIRCUITS IN THE 16 | | CIRCUIT GENERATOR PANEL. 702.5 CAPACITY | | AND RATING. | | AN OPTIONAL STANDBY SYSTEM SHALL HAVE | | ADEQUATE CAPACITY AND RATING FOR THE | | SUPPLY OF ALL EQUIPMENT INTENDED TO BE | | OPERATED AT ONE TIME. OPTIONAL STANDBY | | SYSTEM EQUIPMENT SHALL BE SUITABLE FOR | | THE MAXIMUM AVAILABLE FAULT CURRENT AT | | ITS TERMINALS. THE USER OF THE OPTIONAL | | STANDBY SYSTEM SHALL BE PERMITTED TO | | SELECT THE LOAD CONNECTED TO THE SYSTEM. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] | | | | | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2006-08-14 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-08-14 |
Time |
14:47 |
Rev Time |
0.15 |
Received By |
mperson |
Date |
2006-08-14 |
Time |
14:47 |
Sent To |
B |
|
Notes |
2006-08-14 00:00:00 | | | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | BEFORE FINAL GEN/RES INSPECTION. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-10-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-06 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-06 |
Time |
14:08 |
Sent To |
E |
|
Notes |
2006-10-06 00:00:00 | TO "BTROBAUGH" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-09-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-26 |
Time |
14:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-26 |
Time |
14:25 |
Sent To |
E |
|
Notes |
2006-09-26 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-09-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-19 |
Time |
09:40 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-19 |
Time |
09:40 |
Sent To |
Z |
|
Notes |
2006-09-19 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-08-08 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-08 |
Time |
11:39 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-08 |
Time |
11:39 |
Sent To |
E |
|
Notes |
2006-08-08 00:00:00 | TO "GEN-RES" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-08-18 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-08-18 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-07-31 |
Time |
17:26 |
Sent To |
|
|
Notes |
2006-07-31 00:00:00 | TO Z BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2006-09-29 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-09-29 |
Time |
09:28 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2006-09-29 |
Time |
09:28 |
Sent To |
|
|
Notes |
2006-09-29 00:00:00 | CLEARANCES SHOWN ON PLANS COMPLY WITH | | REQUIREMENTS. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-08-11 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-08-11 |
Time |
16:17 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2006-08-11 |
Time |
16:17 |
Sent To |
P |
|
Notes |
2006-08-11 00:00:00 | *** DENIED *** | | 1) SEE ZONING REVIEW, PLEASE CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2006-09-23 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-09-23 |
Time |
08:46 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-09-23 |
Time |
08:46 |
Sent To |
I |
|
Notes |
2006-09-23 00:00:00 | NOTE: AS INDICATED ON THE TWO COPY OF | | SURVEYS, THE PROPOSED GENERATOR WILL BE | | 20FT FROM SIDE PROPERTY LINE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-08-07 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-08-07 |
Time |
17:40 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-08-07 |
Time |
17:40 |
Sent To |
I |
|
Notes |
2006-08-07 00:00:00 | DENIED, | | 1. PLEASE PROVIDE A FULL SURVEY THAT'S | | INTACT SHOWING THE LOCATION OF THE | | PROPOSED GENERATOR (2 COPIES), ADDRESS | | ETC. | | | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|