Plan Review Details - Permit 06071700
Plan Review Stops For Permit 06071700
Review Stop AD ADDRESSING
Rev No 1 Status P Date 2006-12-05 Cont ID  
Sent By lursu Date 2006-12-05 Time 09:57 Rev Time 0.00
Received By lursu Date 2006-12-04 Time 11:39 Sent To  
Notes
2006-12-05 10:06:23FOR THIS PERMIT THE ADDRESS IS CORRECT ,1700 N DIXIE
 HWY .
  
 LACRAMIOARA URSU
 MIS - GIS SUPPORT SPECIALIST
 E-MAIL:[email protected]
2006-12-04 11:40:543 BUILDINGS ON SAME PCN # - NEED SEPERATE PCN #'S AND
 ADDRESSES FOR EACH - 3 PERMITS (06120031 & 06120030)

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-12-19 Cont ID  
Sent By mjacobs Date 2006-12-19 Time 11:15 Rev Time 0.00
Received By mjacobs Date 2006-12-19 Time 09:38 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-12-05 Cont ID  
Sent By mjacobs Date 2006-12-05 Time 18:03 Rev Time 0.00
Received By mjacobs Date 2006-12-05 Time 16:02 Sent To PC
Notes
2006-12-05 18:03:30 
 BUILDING PLAN REVIEW
 PERMIT:06071700
 ADD:1700 N. DIXIE HWY.
 CONT: PIONEER HURRICANE PROTECTION
 TEL: (561)744-3157
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW 2ND
 ACTION: DENIED
  
 1) PAGE #7 OF THE PRODUCT APPROVAL SHOWS TWO DIFFERENT
 TYPES OF ANCHORS. ON YOURINSTALLATION SCHEDULE, OR ON
 THE ONE PROVIDED IN THE PACKAGE INDICATE WHICH OPENING
 WILL HAVE THE TAPCON AND WHICH ONE WILL HAVE THE
 SOLID-SET ANCHOR. STRIKE OUT THE ANCHOR WHICH WILL NOT
 BE USED. SHOW CLEARLY THE WIDTH AND HEIGHT DIMENSION OF
 EACH OPENING.
  
 NOTE: YOU MAY FILL OUT THE INSTALLATION SCHEDULE
 SUBMITTED IN THE PACKAGE FOR PLAN REVIEW OR PROVIDE A
 SIMILAR SCHEDULE WITH ALL THE INFORMATION MATCHING THE
 ONE IN THE PACKAGE. BE SURE THE EXISTING STRUCTURE IS
 SOLID CONCRETE AND NOT HOLLOW CONCRETE BLOCK.SEE
 ANCHORING SCHEDULE TABLES AND CIRCLE OR HI-LIGHT THE
 CORRECT COLUMNS.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-08-07 Cont ID  
Sent By mjacobs Date 2006-08-07 Time 16:36 Rev Time 0.00
Received By mjacobs Date 2006-08-07 Time 13:40 Sent To PC
Notes
2006-08-07 00:00:00 
  
 1) THE PERMIT APPLICATION INDICATES 13
 OPENINGS, HOWEVER THE DRAWING IN THE
 PACKAGE SHOWS TWO OPENINGS FOR 1700
 S.DIXIE HWY. THE DESCRIPTION ON THE
 APPLICATION SHALL REFLECT THE PROJECT IN
 DETAIL.
  
 2) SEPERATE PERMIT APPLICATIONS WILL BE
 REQUIRED FOR 315 AND 317 WHICH HAVE
 DIFFERENT ADDRESSES AND PCN NUMBERS.
 THEREFORE, SUBMIT THE PRODUCT APPROVALS
 DRAWINGS AND INSTALLATION SCHEDULE FOR
 EACH ADDRESS. TWO COPIES OF EACH ITEM
 FOR EACH ADDRESS.
 FOR INFORMATION PLEASE SEE THE STATE
 WEBSITE AT WWW.FLORIDABUILDING.ORG.
 PRODUCTS WITH STATEWIDE APPROVAL ARE
 REQUIRED TO BE SUBMITTED WITH A COVER
 SHEET THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE.
 WWW.FLORIDABUILDING.ORG
  
 3)THIS IS IN REFERENCE TO THE INADQUATE
 DRAWINGS SUBMITTED. 106.1.3. QUALITY OF
 BUILDING PLANS. BUILDING PLANS SHALL BE
 DRAWN TO A MINIMUM 1/8 INCH SCALE UPON
 SUBSTANTIAL PAPER, CLOTH OR OTHER
 ACCEPTABLE MEDIUM. THE BUILDING OFFICIAL
 MAY ESTABLISH THROUGH DEPARTMENTAL
 POLICY, STANDARDS FOR PLANS AND
 SPECIFICATIONS, IN ORDER TO PROVIDE
 CONFORMITY TO ITS RECORD RETENTION
 PROGRAM. THIS POLICY MAY INCLUDE SUCH
 THINGS AS MINIMUM SIZE, SHAPE, CONTRAST,
 CLARITY, OR OTHER ITEMS RELATED TO
 RECORDS MANAGEMENT.
  
 NOTE: FILL OUT THE INSTALLATION SCHEDULE
 SUBMITTED IN THE PACKAGE FOR PLAN
 REVIEW.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 TEL:(561)805-6726
  
  
  

Review Stop HIST HISTORICAL
Rev No 1 Status P Date 2006-12-04 Cont ID  
Sent By swurafti Date 2006-12-04 Time 11:39 Rev Time 0.00
Received By swurafti Date 2006-12-04 Time 11:32 Sent To  
Notes
2006-12-04 11:33:18HISTORIC APPROVED BY GJUDGE

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-12-05 Cont ID  
Sent By adarroug Date 2006-12-05 Time 14:08 Rev Time 0.00
Received By adarroug Date 2006-12-05 Time 14:08 Sent To B
Notes
2006-12-05 14:08:38TO "MJACOBS" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-08-07 Time   Rev Time 0.00
Received By adarroug Date 2006-07-31 Time 13:07 Sent To  
Notes
2006-07-31 00:00:00TO "MISC" BOX#1


Account Summary | Usage Policy | Privacy Policy