Plan Review Stops For Permit 06071649 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2007-08-23 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2007-08-23 |
Time |
17:41 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2007-08-23 |
Time |
17:41 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-06-27 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2007-06-27 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2007-06-27 |
Time |
10:59 |
Sent To |
|
|
Notes |
2007-06-27 11:04:37 | DENIED | | | | AGAIN !, PLEASE PROVIDE INFORMATION FOR THE BASE PAD | | AND THE FASTENING METHOD FOR THE GENERATOR. | | | | | | | | | | | | L.MARTINEZ | | 561-805-6710 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-09-27 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-09-27 |
Time |
09:00 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2006-09-27 |
Time |
09:00 |
Sent To |
|
|
Notes |
2006-09-27 00:00:00 | DENIED | | | | SHOW GENERATOR SLAB DETAIL AND METHOD OF | | ATTACHMENT TO SLAB. | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-08-18 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-08-18 |
Time |
08:50 |
Rev Time |
0.50 |
Received By |
alange |
Date |
2006-08-18 |
Time |
08:50 |
Sent To |
|
|
Notes |
2006-08-18 00:00:00 | DENIED | | | | SHOW GENERATOR SLAB DETAIL AND METHOD OF | | ATTACHMENT TO SLAB. | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2007-07-16 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-07-16 |
Time |
15:12 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2007-07-16 |
Time |
14:24 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2007-05-02 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2007-05-02 |
Time |
12:46 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2007-05-02 |
Time |
12:07 |
Sent To |
G |
|
Notes |
2007-05-02 12:46:48 | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS FOR CODE | | COMPLIANCE AND RESUBMIT FOR REVIEW | | | | 1} THE RISER DIAGRAM IS INCOMPLETE, IT DOES NOT SHOW | | THE METER LOCATION IN THE SERVICE. PLEASE LOCATE ALL | | SERVICE EQUIPMENT ON THE PLAN, METER ENCLOSURE, | | DISCONNECTS AND PANELS, SO THAT COMPLIANCE WITH | | ARTICLES 225 AND 230 CAN BE REVIEWED. DO THIS ON A SITE | | PLAN, NOT ON THE SURVEY, 106.1.3 FBC. SEE NOTE #2 AND | | 3, PREVIOUS REVIEW. THE GENERATOR AND A DISCONNECT ARE | | ALL THAT'S SHOWN. | | | | 2} 702.5 CAPACITY AND RATING. AN OPTIONAL STANDBY | | SYSTEM SHALL HAVE ADEQUATE CAPACITY AND RATING FOR THE | | SUPPLY OF ALL EQUIPMENT INTENDED TO BE OPERATED AT ONE | | TIME.THE LOAD CALCULATION THAT WAS SUBMITTED IS | | INCORRECT, SEE 220.31(B) IF USING OPTIONAL. THE HEAT | | LOAD IS AT 100%. | | | | 3} THE GENERATOR DOES NOT MEET THE MANUFACTURERS | | RECOMENDED SETBACKS, SEE PAGE 9 OWNERS MANUAL. | | | | 4} THE INFORMATION REGARDING THE TRANSFER SWITCH IS | | INSUFFICIENT. INDICATE THAT THE "PANEL SCHEDULE" | | SUBMITTED WITH 16 CIRCUITS IS IN FACT THE CIRCUITS IN | | THE TRANSFER SWITCH OR IN A GENERATOR PANEL. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-09-14 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-09-14 |
Time |
15:45 |
Rev Time |
1.00 |
Received By |
btrobaug |
Date |
2006-09-14 |
Time |
14:58 |
Sent To |
P |
|
Notes |
2006-09-14 00:00:00 | | | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | THE VALUE ON THE APPLICATION MUST | | INCLUDE THE TOTAL COST OF LABOR AND | | MATERIAL FOR THE GENERATOR, EQUIPMENT | | (TRANSFER SWITCHES, PANELS ETC.) | | AND PAD PER 108.3 FBC AS AMENDED. | | INCREASE THE VALUE AT THE COUNTER WHEN | | RESUBMITTING, AND GET A RECEIPT FROM THE | | PERMIT CLERK.VALUE HAS BEEN INCREASED BY | | REVIEWER, FEE MUST BE PAID PRIOR TO RE | | SUBMITTING FOR REVIEW. | | | | | | 1} THE RISER DIAGRAM IS NOT LEGIBLE. | | PLEASE INCREASE THE SIZE OR REDRAW FOR | | CLARITY. 106.1.3 FBC AMMENDED. STILL NOT | | LEGIBLE ENOUGH TO RETAIN FOR RECORDS. | | | | 2} PLEASE NOTE A DISCONNECT IS REQUIRED | | PER 225.31 AND 32. INDICATE LOCATION ON | | THE RISER AND SITE PLAN. THE TRANSFER | | SWITCH MAY NOT MEET THIS REQUIREMENT, | | SEE SPECS BEFORE SUBMITTING. CAN'T READ | | RISER. UTILITY CONNECTION NOT INDICATED. | | IS THE TRANSFER SWITCH NOW THE FIRST | | MEANS OF DISCONNECT? | | | | 3} PROVIDE A SITE DIAGRAM PER 106.3.5.4 | | FBC AS AMMENDED, INCLUDING GENERATOR AND | | RELATED EQUIPMENT AND ALL SERVICE | | EQUIPMENT. SURVEY IS NOT A SITE PLAN. | | ALL EQUIPMENT WAS NOT LISTED ON THE | | "SURVEY" EITHER. | | | | 5} PROVIDE SPECIFICATIONS FOR THE | | TRANSFER SWITCH, INDICATING NUMBER OF | | POLES, AND HOW BOTH GENERATOR AND | | UTILITY POWER SOURCE CAN BE | | DISCONNECTED.THE SPECIFICATIONS PROVIDED | | DO NOT ALLOW FOR THE UTILITY TO BE | | DISCONNECTED. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-08-09 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-08-09 |
Time |
11:17 |
Rev Time |
1.00 |
Received By |
btrobaug |
Date |
2006-08-09 |
Time |
10:26 |
Sent To |
P |
|
Notes |
2006-08-09 00:00:00 | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | THE VALUE ON THE APPLICATION MUST | | INCLUDE THE TOTAL COST OF LABOR AND | | MATERIAL FOR THE GENERATOR, EQUIPMENT | | (TRANSFER SWITCHES, PANELS ETC.) | | AND PAD PER 108.3 FBC AS AMENDED. | | INCREASE THE VALUE AT THE COUNTER WHEN | | RESUBMITTING, AND GET A RECEIPT FROM THE | | PERMIT CLERK. | | | | | | 1} THE RISER DIAGRAM IS NOT LEGIBLE. | | PLEASE INCREASE THE SIZE OR REDRAW FOR | | CLARITY. 106.1.3 FBC AMMENDED. | | | | 2} PLEASE NOTE A DISCONNECT IS REQUIRED | | PER 225.31 AND 32. INDICATE LOCATION ON | | THE RISER AND SITE PLAN. THE TRANSFER | | SWITCH MAY NOT MEET THIS REQUIREMENT, | | SEE SPECS BEFORE SUBMITTING. | | | | 3} PROVIDE A SITE DIAGRAM PER 106.3.5.4 | | FBC AS AMMENDED, INCLUDING GENERATOR AND | | RELATED EQUIPMENT AND ALL SERVICE | | EQUIPMENT. | | | | 4} INDICATE WHICH MODEL GENERATOR IS | | BEING USED, THE SPEC BOOK IS GENERIC. | | | | 5} PROVIDE SPECIFICATIONS FOR THE | | TRANSFER SWITCH, INDICATING NUMBER OF | | POLES, AND HOW BOTH GENERATOR AND | | UTILITY POWER SOURCE CAN BE | | DISCONNECTED. | | | | 6} THE PERSON TAKING RESPONSIBILITY FOR | | THE DESIGN MUST PRINT AND SIGN THEIR | | NAME TO SAME PER 106.3.4.2. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLAN REVIEW | | 561/805-6718 | | [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
P |
Date |
2007-08-01 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-08-01 |
Time |
13:10 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2007-08-01 |
Time |
13:09 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2007-05-03 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-05-03 |
Time |
10:12 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2007-05-03 |
Time |
10:12 |
Sent To |
M |
|
Notes |
2007-05-03 10:27:18 | DENIED 3RD TIME | | REFERENCE: | | ** FBC-2004 FUEL GAS. | | ** THE CITY OF WEST PALM BEACH GAS AND RESIDENTIAL | | GENERATOR PERMITAPPLICATION REQUIREMENTS. | | | | THE FOLLOWING CORRECTION/INFORMATION IS REQUIRED FOR | | GAS PLAN REVIEW TO MEET CODE COMPLIANCE: | | | | 1. THE GENERATOR DOES NOT MEET THE MANUFACTURER'S | | RECOMENDED SETBACKS, PLEASE REFERENCE PAGE 9 OF OWNERS | | MANUAL AND PLEASE REVISE THE SITE PLAN TO REFLECT THE | | MANUFACTURER'S RECOMENDATIONS OF THREE FEET (3') ON THE | | RESUBMITTAL. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2006-09-15 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-09-15 |
Time |
09:07 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-09-15 |
Time |
09:07 |
Sent To |
B |
|
Notes |
2006-09-15 00:00:00 | ******DENIED 2ND TIME***** | | | | REFERENCE: FBC-2004 FUEL GAS | | FBC-2004 CHAPTER 1 | | | | THE FOLLOWING INFORMATION IS STILL | | REQUIRED FOR GAS PLAN REVIEW DUE TO THE | | FACT THAT THE PREVIOUS COMMENTS HAVE NOT | | BEEN ADDRESSED: | | | | 1. MORE INFOMATION IS REQUIRED ON THE | | TYPE OF MATERIAL THAT IS BEING INDICATED | | ON THE GAS RISER DIAGRAM. WHAT IS "CTS"? | | PLEASE CLARIFY FOR THE RESUBMITTAL. | | 2. BTU LOAD OF EACH APPLIANCE AND THE | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | 402.4(33). | | NOTE: PLEASE INDICATE THE BTU LOAD LOAD | | OF THE GENERATOR ON THE ISOMETRIC RISER | | DIAGRAM FOR THE RESUBMITTAL. | | 3. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | STANDARDS NFPA 54, NFPA 58, AND THE | | FBC-2004 FUEL GAS CODE SEC 402.2 | | NOTE: PLEASE SUBMIT MANUFACTURER CUT | | SHEETS OF THE 1ST AND 2ND STAGE | | REGULATORS. | | 4.PLEASE INDICATE WHICH MODEL GENERATOR | | IS BEING USED IN THE MANUFACTURER | | ISTALLATION AND OWNERS MANUAL ON PAGE 6 | | SO THAT THE GENERATOR BTU LOADS CAN BE | | VERIFIED. | | 5. CLEARLY SHOW THE LOCATION AND CAP- | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | OR ASME), THE DISTANCE OF THE TANK FROM | | THE BUILDING AND ADJACENT PROPERTY LINES | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | INGS, AND THE LOCATION OF ANY BUILDING | | OPENINGS BELOW THE RELIEF VALVE OF THE | | TANK PER NFPA 58, TABLE 3-2.2.2. | | NOTE: THERE ARE NO MEASUREMENTS | | INDICATED ON THE SURVEY COMPLYING WITH | | NFPA 58, PLEASE ADD THE MEASUREMENTS FOR | | THE RESUBMITTAL. | | 6. FBC-2004 CHAPTER 1,SECTION 106.3.4.2: | | THE PERSON RESPONSIBLE FOR THE DESIGN OF | | THE DRAWING SHALL CLEARLY PRINT AND SIGN | | NAME, AND ALSO DATE DRAWING. PLEASE DO | | THIS PRIOR TO RESUBMITTING. | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN | | RESUBMITTING, PLEASE REPLACE ONLY SHEETS | | WHICH HAVE CHANGED AND PROVIDE ONE COPY | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | ONLY. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 | | | | | | | | | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2006-08-10 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-08-10 |
Time |
15:47 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2006-08-10 |
Time |
15:47 |
Sent To |
M |
|
Notes |
2006-08-10 00:00:00 | REFERENCE: GAS PERMIT #06071651 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-05-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-05-01 |
Time |
10:10 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-05-01 |
Time |
10:10 |
Sent To |
E |
|
Notes |
2007-05-01 10:11:22 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-04-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-24 |
Time |
10:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-24 |
Time |
10:59 |
Sent To |
Z |
|
Notes |
2007-04-24 11:00:12 | TO "Z" BOX/RESUB--NEW SHEETS FOR "Z" AND "M" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-08-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-26 |
Time |
14:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-26 |
Time |
14:17 |
Sent To |
E |
|
Notes |
2006-08-26 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-08-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-07 |
Time |
14:18 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-07 |
Time |
14:18 |
Sent To |
E |
|
Notes |
2006-08-07 00:00:00 | TO "GEN-RES" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-08-18 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-08-18 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-07-28 |
Time |
14:37 |
Sent To |
|
|
Notes |
2006-07-28 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2007-08-02 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-08-02 |
Time |
08:17 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2007-08-02 |
Time |
08:17 |
Sent To |
Z |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2007-05-04 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-05-04 |
Time |
08:45 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2007-05-04 |
Time |
08:45 |
Sent To |
B |
|
Notes |
2007-05-04 08:47:04 | *** DENIED *** | | 1) SEE GAS REVIEW NOTE #1, PLEASE CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2006-08-11 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-08-11 |
Time |
16:26 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2006-08-11 |
Time |
16:26 |
Sent To |
B |
|
Notes |
2006-08-11 00:00:00 | *** PROVISO *** | | 1) PER 2004 FBC, FUEL GAS - POWERED | | EQUIPMENT - PERMANENTLY INSTALLED | | EQUIPMENT POWERED BY INTERNAL COMBUSTION | | ENGINES SHALL BE INSTALLED IN ACCORDANCE | | WITH MANUFACTURE'S INSTALLATION | | INSTRUCTIONS AND NFPA 37. | | | | NFPA 37 INSTALLATION & USE OF STATIONARY | | COMBUSTION ENGINES & GAS TURBINES: | | 4.1.4ENGINES (GENERATORS) LOCATED | | OUTDOORS SHALL BE MINIMUM OF 5 FT FROM | | OPENINGS IN WALLS & AT LEAST 5 FT FROM | | STRUCTURES HAVING COMBUSTIBLE WALLS.A | | MINIMUM CLEARANCE IS NOT REQUIRED WHEN | | (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | RESISTANCE RATING OF 1 HOUR OR (2) THE | | WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF | | NON-COMBUSTIBLE MATERIALS, AND IT HAS | | BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | MATERIALS OUTSIDE THE ENCLOSURE. | | INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS | | SHOULD NOT TERMINATE UNDER STRUCTURES OR | | WHERE THE EXHAUST MIGHT BE DRAWN INTO | | THE VENTILATION INTAKES. | | | | 2004 FMC 804.3.5 #3, WHERE THE | | TERMINATION IS LOCATED BELOW AN ADJACENT | | ROOF STRUCTURE, THE TERMINATION POINT | | SHALL BE LOCATED AT LEAST 3 FT FROM THE | | ROOF STRUCTURE. | | | | PLEASE NOTE, WHILE ZONING ALLOWS | | MECHANICAL EQUIPMENT TO ENCROACH 4 FT | | INTO THE REQUIRED SETBACK, GENERATORS | | SHALL MAINTAIN THE REQUIRED ABOVE | | MENTIONED CLEARANCES TO THE ADJACENT | | PROPERTY STRUCTURES, I.E. FENCE, | | BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | | PROVIDE MANUFACTURE'S INSTALLATION | | INSTRUCTIONS AT THE JOBSITE FOR THE | | FIELD INSPECTOR. | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2007-08-02 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-08-02 |
Time |
08:52 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-08-02 |
Time |
08:52 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2007-04-30 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2007-04-30 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2007-04-30 |
Time |
14:21 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2006-08-05 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-08-05 |
Time |
14:28 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-08-05 |
Time |
14:28 |
Sent To |
I |
|