Plan Review Stops For Permit 06071495 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2006-07-31 |
|
|
Cont ID |
|
Sent By |
lursu |
Date |
2006-07-31 |
Time |
16:15 |
Rev Time |
0.00 |
Received By |
lursu |
Date |
2006-07-31 |
Time |
16:15 |
Sent To |
|
|
Notes |
2006-07-31 00:00:00 | UPDATE OWNER INFO USING PAPA |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2007-04-25 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2007-04-25 |
Time |
18:35 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2007-04-25 |
Time |
18:35 |
Sent To |
|
|
Notes |
2007-04-25 18:43:52 | | | TRUSS ENGINEERING TO BE APPROVED BEFORE INSTALLATION | | LM |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-03-13 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2007-03-13 |
Time |
17:42 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2007-03-13 |
Time |
17:41 |
Sent To |
|
|
Notes |
2007-03-13 17:51:30 | | | BUILDING REVIEW COMMENTS | | | | | | | | TRUSS ENGINEEERING AND LAYOUT ARE REQUIRED TO BE | | APPROVED BY JACK HAWK, ARCHITECT OF RECORD AND SIGNED | | AND SEALED BY TRUSS CO. ENGINEER. | | | | ENERGY CALC'S SUBMITTED REQUIRES SIGNATURE AND DATE | | FROM THE OWNER OR AN AGENT. | | | | N.O.C. HAS EXPIRED , PLEASE RE-CERTIFY ,AFTER ,THE | | NEXT REVIEW CYCLE IS COMPLETED. | | | | | | | | | | | | | | | | L.MARTINEZ | | 561-805-6710 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-10-23 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2006-10-23 |
Time |
10:25 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2006-10-23 |
Time |
10:25 |
Sent To |
PC |
|
Notes |
2006-10-23 10:44:56 | | | | | DENIED | | | | 2ND REVIEW | | | | 1) OK | | 2) OK | | 3) OK | | | | 4) SUBMIT ENGINEERED TRUSS DRAWINGS THAT | | COMPLY WITH R802.10.1 FBC WITH PERMIT APPLICATION OR | | BEFORE INSTALLATION THAT HAVE BEEN REVIEWED AND | | APPROVED BY THE DESIGNER OF RECORD | | | | 5) OK | | 6) OK | | 7) OK | | 8) OK | | 9) OK | | 10) OK | | | | 11) SUBMIT ENERGY CALC'S PER 13-101.2.2 | | FBC. BE SURE THAT THEY ARE SIGNED AND | | DATED BY PREPARER AND OWNER/AGENT PRIOR | | TO SUBMITTAL | | **********PLEASE SEE MECH REVIEW NOTES*********** | | | | NEW REVIEW NOTES: | | | | 1) PER 713.13(2) F.S. | | IF THE IMPROVEMENT DESCRIBED IN THE NOC HAS NOT | | COMMENCED WITHIN 90 DAYS OF RECORDING THE NOTICE IS | | VOID | | | | 2) THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA | | STATE PRODUCT APPROVAL COVER | | SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON | | WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT | | SUBMITTED APPLICATIONS WILL BE DENIED | | PLEASE SUBMIT FL# 539-R1 FOR JELD-WEN DOORS, FL# 183-R1 | | FOR GAF SHINGLES AND FL#7149 FOR THE DAB GARAGE DOOR | | | | 3) PRODUCT APPROVALS FOR THE KINCO WINDOWS STATE THEY | | ARE NON IMPACT AS A RESULT IMPACT PROTECTION IS | | REQUIRED. ALSO PLEASE STATE THE TYPE OF GLASS THAT WILL | | BE USED AS SOME TYPES DO NOT MEET THE REQUIRED DESIGN | | PRESSURES | | | | 4) REMOVE INCORRECT INFORMATION ON THE WINDOW SCHEDULE | | PAGE A/3 ( WRONG NOA#, IMPACT GLAZING, DESIGN | | PRESSURES,ETC) | | | | 5) SHUTTERS REQUIRE A KEY PLAN, SHUTTER SCHEDULE AND | | THE DRAWINGS THAT ARE PART OF THE PRODUCT APPROVALS | | CLEARLY MARKED WITH THE INFORMATION SPECIFIC TO THE | | SITE (TYPE OF CONSTRUCTION, MOUNTING METHOD, ANCHOR | | TYPE, ETC.) PLEASE SEE THE ATTACHED MEMO AND SCHEDULE | | | | 6) NO PRODUCT APPROVAL WAS RESUBMITTED FOR THE SLIDING | | GLASS DOOR | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-08-08 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-08-04 |
Time |
09:23 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2006-08-08 |
Time |
06:55 |
Sent To |
PC |
|
Notes |
2006-08-08 00:00:00 | | | | | DENIED | | | | 1) THE CLAIMED VALUATION ON THE PERMIT | | APPLICATION IS LOW. FOR PERMITTING | | PURPOSES, VALUATION OF BUILDINGS AND | | SYSTEMS SHALL BE THE TOTAL REPLACEMENT | | COST EXCLUDING LAND VALUE. OUR VALUATION | | REFERENCE IS ICC (BVD), MARSHALL-SWIFT | | AND MEANS COST ANALYSIS SERVICES PER | | 108.3 FBC* | | | | 2) THE STATE OF FLORIDA REQUIRES | | COLLECTION OF A RADON SURCHARGE ON ALL | | NEW CONSTRUCTION COMPUTED ON UNDER ROOF | | FLOOR SPACE PER 10D-91 FAC. THESE FEES | | WILL BE ADDED TO THE PERMIT APPLICATION | | FEES | | | | 3) A TITLE BLOCK WITH THE INFORMATION | | SPECIFIED PER 61G1-16.004 FAC SHALL BE | | PRESENT ON DRAWINGS ISSUED BY THE | | RESPONSIBLE ARCHITECT AND MUST,AT A | | MINIMUM CONTAIN | | 1)FIRM NAME,ADDRESS, AND TELEPHONE # | | 2)FIRM LICENCE # | | 3)NAME OF PROJECT | | 4)DATE PREPARED | | 5)A SPACE FOR SIGNATURE & DATED SEAL | | 6)A SPACE FOR PRINTED NAME AND LICENCE# | | OF PERSON SEALING THE DOCUMENT | | | | 4) SUBMIT ENGINEERED TRUSS DRAWINGS THAT | | COMPLY WITH R802.10.1 FBC WITH PERMIT | | APPLICATION OR BEFORE INSTALLATION THAT | | HAVE BEEN REVIEWED AND APPROVED BY THE | | DESIGNER OF RECORD | | | | 5) PROVIDE A SITE PLAN THAT SHOWS | | DRAINAGE IN COMPLIANCE WITH THE | | REQUIREMENTS OF R403.1 | | | | 6) MINIMUM DESIGN LOADS ON DRAWINGS | | REFERENCED TO ASCE 7-98, PLEASE SEE | | REFFERENCE ADOPTED BY THE 2004 FBC IS | | ASCE 7-02. DRAWINGS TO REFLECT THIS SEE | | A/3, A/4 AND A/6 | | | | 7) GENERAL NOTES A/6 STATE R30 | | INSULATION IN CEILING ABOVE CONDITIONED | | SPACE BUT WALL SECTION SHOWS R19 PLEASE | | CLARIFY | | | | 8) PROVIDE SILL DETAIL | | | | 9) DRAWINGS SHOW TOP OF BEAM AT 8'-2" | | BUT GARAGE DOOR IS A 7'-0" AND THE | | LINTEL PC-1 IS 24" DEEP PLEASE CLARIFY. | | | | 10) BEFORE A PERMIT TO CONSTRUCT, MAY | | BE ISSUED, IMPACT FEES MUST BE PAID TO | | PALM BEACH COUNTY. THE ACTUAL PERMIT | | SETS OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561) 233-5025 FOR MORE | | INFORMATION. | | | | 11) SUBMIT ENERGY CALC'S PER 13-101.2.2 | | FBC. BE SURE THAT THEY ARE SIGNED AND | | DATED BY PREPARER AND OWNER/AGENT PRIOR | | TO SUBMITTAL. PLEASE SUBMIT ON FORM | | 600A-2004 AND BE SURE CEILING INSULATION | | VALUE MATCHES DRAWINGS | | | | 12) THE FOLLOWING PRODUCT APPROVALS | | REQUIRE CORRECTIONS | | A) THURMA-TRU DOES NOT HAVE STATE | | APPROVAL FOR THIS PRODUCT (WILL GIVE | | MIAMI-DADE NOA A LOCAL PROD. APPROVAL) | | B) GARAGE DOOR DESIGN PRESSURE DOES NOT | | MEET THE DESIGN PRESSURE IN THE DOOR | | SCHEDULE | | C) TIMBERLINE SELECT 40 SHINGLE NOA HAS | | BEEN REVISED (04-0305.04) | | D) KINCO NOA FOR SGD HAS EXPIRED SEE | | STATE APPROVAL CLICK ON PDF FILE AND | | PRINT INSTALLATION FOR 1X BUCK AND 2X | | BUCK BOTH ARE GOOD TO -70 PSF (FLORIDA | | SHEET OK) | | E) STATE PRODUCT APPROVAL DOES NOT COVER | | M40 XHP ONLY HP PLEASE SUBMIT REVISED | | MIAMI-DADE NOA (06-0413.06) FOR LOCAL | | PROD APPROVAL | | | | THOSE PRODUCTS WHICH ARE REGULATED BY | | DCA RULE 9B-72 SHALL BE REVIEWED AND | | APPROVED IN WRITING BY THE DESIGNER OF | | RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL PER 106.3.3 FBC* | | (PLEASE CHECK CORRECTED COPIES) | | | | 13)A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT IS REQUIRED PRIOR TO | | A PERMIT BEING ISSUED | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | | | | | | | | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2007-01-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-01-11 |
Time |
15:22 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-01-11 |
Time |
15:10 |
Sent To |
M |
|
Notes |
2007-01-11 15:26:29 | *** REDLINED PLANS*** | | | | | | 1) RISER STILL SHOWS OCP FOR AHU AT 35A, WHERE 424.4B | | REQUIRES 125% MIN. PLEASE SEE PANEL SCHEDULE SHOWS 50A | | BREAKER. | | 2) PLEASE ALSO SEE CODE REQUIRES SMOKE ALARMS.NFPA-72 | | 11.5.1.1, 11.8.3 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-10-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-10-13 |
Time |
19:57 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-10-13 |
Time |
19:01 |
Sent To |
M |
|
Notes |
2006-10-13 19:57:17 | ******** UNSAT2ANDREVIEW ********* | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW STILL | | NEED TO BE ADDRESSED ALONG WITH NEW NOTES DUE TO | | CHANGES MADE TO PLANS FROM PREVIOUS REVIEW. | | PLEASE SEE NOTES BELOW ARE TAKEN DIRECTLY FROM PREVIOUS | | REVIEW WITH NEW ADDED TO BOTTOM OFREVIEW. | | | | 1) NOTE:OK. | | | | 2) NOTE:NO, PLEASE SEE ALL SEALS ON ALL SHEETS ON | | BOTH SETS SHALL BE CLEAR AND VISIBLE AS REQUIRED UNDER | | FLORIDA ADMINISTRATIVE CODE AND FLORIDA STATUES AS | | PREVIOUSLY NOTED. THIS IS REQUIRED AS THE SEALS ARE NOT | | CLEAR. PLEASE OBTAIN NEW SEAL IF NEEDED. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE BE SURE TITLE BLOCKS | | CONTAIN ALL INFORMATION AS REQUIRED BY | | FAC 61G1-16.004. PLEASE SEE MISSING THE | | PRINTED NAME AND LICENSE NUMBER OF SAID | | ARCHITECT. | | PLEASE ALSO BE SURE ALL SEALS ARE | | RAISED, CLEAR AND VISABLE WITH ALL | | INFORMATION ON SAID SEALS. PLEASE SEE | | THAT MANY OF THE SEALS ARE NOT CLEAR. | | FS 481.221 | | | | 3)NOTE: NO, NOTHING SUBMITTED. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | RATED FOR THE AVAILABLE FAULT CURRENT. | | PER 110.9. FBC 106.1.2 | | | | 4) NOTE: NO, PLEASE SEE AS NOTED ON PREVIOUS REVIEW, | | 424.3B. MIN OCP REQUIRED. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE CORRELATE AND COMPLETE | | INFORMATION FOR AHU KW RATING. PLEASE | | SEE LOAD CALCS INDICATE 100% = 6500VA , | | YET THE OCP AND CONDUCTOR SIZES LEND TO | | THIS AS A 10KW HEAT STRIP? PLEASE | | CORRELATE AS THE MECH SHEETS SHOW | | ANOTHER SIZE. PLEASE ADJUST ALL ONCE THE | | KW RATING IS SET. | | 424.3B.,220,310.16,240.4 ETC | | | | 5) NOTE:NO, PLEASE SEE NOTE STILL MENTIONS TO WIRE | | INTO KITCHEN LIGHTING CIRCUIT ALTHOUGH NEW NOTE WAS | | ADDED. | | THIS COULD HAVE BEEN REDLINED, HOWEVER PLANS ARE COMING | | BACK FOR CORRECTIONS AT THIS TIME. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE IDICATE ALL CIRCUITS ON | | PANELS WHICH ARE REQUIRED TO CONTAIN ARC | | FAULT PROTECTION. PLEASE SEE NOTES FOR | | ARC FAULT MENTIONS ONLY RECEPTS, LTS AND | | FANS. (NO FANS SHOWN ) ALTHOUGH | | PROTECTION OF SD'S IS ALSO REQUIRED. | | PELASE SEE NOTE ABOVE MENTIONS AND PLANS | | SHOWS SD'S CIRCUITED TO KITCHEN AND BATH | | RM LIGHTING, WHICH IS OK, HOWEVER THIS | | CIRCUIT WOULD ALSO REQUIRED ARC FAULT | | PROTECTION. | | 210.12B, 408.4 | | | | 6) NOTE: OK. | | | | 7) NOTE: OK. | | | | 8) NOTE: OK, HOWEVER SEE NEW NOTE. | | | | ** PREVIOUS NEWNOTE ** | | PLEASE SEE MISSING GFI RECEPT | | FOR CU. 210.63,210.8A2 | | | | 9) NOTE: OK. | | | | 10) NOTE: OK. | | | | 11) NOTE: OK. | | | | ** NEW NOTES ** | | | | 12) NOTE: PLEASE SEE NOTE" ** IMPORTANT** "NOTE BELOW | | WHICH WAS AT THE END OF THE PREVIOUS REVIEW NOTES WHICH | | ASKED FOR ALL OLD SHEETS TO BE REMOVED. PLEASE SEE THIS | | WAS NOT DONE. PLEASE DO SO BEFORE RESUBMITTING PLANS | | FOR NEXT REVIEW AS THIS WILL HELP IN NOT DELAYING | | PROJECT. | | ** NOTED PREVIOUS REVIEW** | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE, PLANS WILL BE | | PICKED UP FOR CORRECTIONS. PLEASE KNOW, | | BEFORE RESUBMITTING PLANS, ALL | | OLD/VOIDED SHEETS MUST BE COMPLETELY | | REMOVED FROM SETS AND ONLY NEW REVISED | | SHEETS SHOULD BE INSERTED INTO COMPLETE | | SETS FOR REVIEW AND STAMPING. ONLY ONE | | COPY OF THE OLD/VOIDED SHEETS SHOULD BE | | SUBMITTED SEAPARATELY FOR REFERENCE. | | | | 13) NOTE: PLEASE SEE THE NEW GFI RECEPT REQUIRED FOR | | THE OUTSIDE CU WHICH WAS ADDED TO THESE PLANS IS BEING | | SHOWN CIRCUITED TO THE #1, WHICH ALSO FEEDS THE AHU. | | MAY NOT BE TAPPED FROM THIS 220VA CIRCUIT . | | 310.16,240.4., 240.21 ETC | | | | 14) NOTE: PLEASE SEE THE RECORDED NOTICE OF COMMENCMENT | | SUBMITTED IS NO LONGER VALID AS IS HAS EXCEEDING THE | | 90DAYS SINCE BEING RECORD AND WORK HAS NOT COMMENCED. | | PLEASE SEE FS 713.13(2). PLEASE KNOW, THE RECORDED NOC | | IS ONLY REQUIRED AFTER PERMIT IS ISSUED AND BEFORE | | PICKING UP PERMIT. | | | | 15) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | DESIGN PROFESSIONALS AND REPEAT COMMENTS FOR CODE | | COMPLIANCE. THIS IS ONLY A NOTICE GIVEN AT THIS TIME. | | PLEASE KNOW ONE SET OF ELECTRICAL SHEETS FROM EACH | | SUBMITTED SET IS BEING RETAINED BY THIS OFFICE. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-07-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-07-27 |
Time |
19:26 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-07-27 |
Time |
18:46 |
Sent To |
M |
|
Notes |
2006-07-27 00:00:00 | ******** UNSAT ********* | | | | 1) NOTE: PLEASE SEE THAT THE FOLLOWING | | CODES ARE REFELCTED ON ELECTRICAL PLANS | | AT A MINIMUM. NFPA-70 2002 (NEC) AND | | NFPA-72 2002. | | PLEASE SEE PLANS MENTIONS , "LATEST | | EDITIONS", HOWEVER THE LATEST EDITIONS | | ARE NOT YET ADOPTED BY THE STATE OF | | FLORIDA. | | | | 2) NOTE: PLEASE BE SURE TITLE BLOCKS | | CONTAIN ALL INFORMATION AS REQUIRED BY | | FAC 61G1-16.004. PLEASE SEE MISSING THE | | PRINTED NAME AND LICENSE NUMEBR OF SAID | | ARCHIECT. | | PLEASE ALSO BE SURE ALL SEALS ARE | | RAISED, CLEAR AND VISSABLE WITH ALL | | INFORMATION ON SAID SEALS. PLEASE SEE | | THAT MANY OF THE SEALS ARE NOT CELAR. | | FS 481.221 | | | | 3)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | RATED FOR THE AVAILABLE FAULT CURRENT. | | PER 110.9. FBC 106.1.2 | | | | 4) NOTE: PLEASE CORRELATE AND COMPLETE | | INFORMATION FOR AHU KW RATING. PLEASE | | SEE LOAD CALCS INDICATE 100% = 6500VA , | | YET THE OCP AND CONDUCTOR SIZES LEND TO | | THIS AS A 10KW HEAT STRIP? PLEASE | | CORRELATE AS THE MECH SHEETS SHOW | | ANOTHER SIZE. PLEASE ADJUST ALL ONCE THE | | KW RATING IS SET. | | 424.3B.,220,310.16,240.4 ETC | | | | 5) NOTE: PLEASE IDICATE ALL CIRCUITS ON | | PANELS WHICH ARE REQUIRED TO CONTAIN ARC | | FAULT PROTECTION. PLEASE SEE NOTES FOR | | ARC FAULT MENTIONS ONLY RECEPTS, LTS AND | | FANS. (NO FANS SHOWN ) ALTHOUGH | | PROTECTION OF SD'S IS ALSO REQUIRED. | | PELASE SEE NOTE ABOVE MENTIONS AND PLANS | | SHOWS SD'S CIRCUITED TO KITCHEN AND BATH | | RM LIGHTING, WHICH IS OK, HOWEVER THIS | | CIRCUIT WOULD ALSO REQUIRED ARC FAULT | | PROTECTION. | | 210.12B, 408.4 | | | | 6) NOTE: PLEASE COMPLETE PANEL SCHEDULE | | SPECIFIC TO ALL AREAS. IE LIVING RM | | RECEPTS, BATH LTS, BEDRM #3, ETC. | | 408.4 | | IT IS KNOW TO THIS OFFICE THESE WILL | | MOST LIKELY BE REVISED DURING | | CONSTRUCTION. | | | | 7) NOTE: PLEASE SEE A CIRCUIT #17 SEEM | | TO BE IN THE CLOSET IN BEDRM #2 WHICH | | DOES NOT SEEM TO FEED ANYTHING? | | PLEASE CLARIFY. | | 106.1.2 | | | | 8) NOTE: PLEASE SEE MISSING GFI RECEPT | | FOR CU. 210.63,210.8A2 | | | | 9) NOTE: PLEASE SEE MISSING GFI RECEPT | | FOR KITCHEN COUNTER SPACE. 210.52C1, | | 210.8A6 | | | | 10) NOTE: PLEASE SEE MISSING RECEPTS FOR | | MORE THAN 2' OF WALL SPACE. | | 210.52 | | *REDLINED** | | | | 11) NOTE: PLEASE CLARIFY SERVICE. IS | | THIS A SEPARATE METER OR A METERMAIN | | COMBO? | | 106.1.2 | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE, PLANS WILL BE | | PICKED UP FOR CORRECTIONS. PLEASE KNOW, | | BEFORE RESUBMITTING PLANS, ALL | | OLD/VOIDED SHEETS MUST BE COMPLETELY | | REMOVED FROM SETS AND ONLY NEW REVISED | | SHEETS SHOULD BE INSERTED INTO COMPLETE | | SETS FOR REVIEW AND STAMPING. ONLY ONE | | COPY OF THE OLD/VOIDED SHEETS SHOULD BE | | SUBMITTED SEAPARATELY FOR REFERENCE. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2007-04-04 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2007-04-04 |
Time |
17:25 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2007-04-04 |
Time |
17:25 |
Sent To |
M |
|
Notes |
2007-04-04 17:25:54 | TO TOM GORDON |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-04-02 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2007-04-02 |
Time |
17:53 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2007-04-02 |
Time |
17:53 |
Sent To |
Z |
|
Notes |
2007-04-02 17:53:18 | TO ZONING |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-01-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-09 |
Time |
17:01 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-09 |
Time |
17:01 |
Sent To |
E |
|
Notes |
2007-01-09 17:02:15 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-12-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-12-27 |
Time |
15:39 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-12-27 |
Time |
15:39 |
Sent To |
Z |
|
Notes |
2006-12-27 15:40:02 | TO "Z" BOX/RESUB--PLANS TO INCOMING TODAY, PLEASE SEE | | FRONT SCREEN NOTES |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-10-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-12 |
Time |
09:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-12 |
Time |
09:55 |
Sent To |
E |
|
Notes |
2006-10-12 09:55:40 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-10-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-05 |
Time |
13:13 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-05 |
Time |
13:13 |
Sent To |
Z |
|
Notes |
2006-10-05 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2006-08-08 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-27 |
Time |
13:26 |
Sent To |
|
|
Notes |
2006-07-27 00:00:00 | TO "SFR" "Z" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2007-04-05 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-04-05 |
Time |
08:29 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2007-04-05 |
Time |
08:29 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
F |
Date |
2007-01-12 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-01-12 |
Time |
12:00 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2007-01-12 |
Time |
12:00 |
Sent To |
P |
|
Notes |
2007-01-12 12:03:12 | *** DENIED *** | | 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT | | ALSO, PER 2004 FBC 13-600.3.ABC.2. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2006-10-16 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-10-16 |
Time |
08:59 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2006-10-16 |
Time |
08:59 |
Sent To |
P |
|
Notes |
2006-10-16 09:19:55 | *** DENIED *** | | 1)ENERGY CALCULATIONS NEED TO BE ON FORM | | 600A-04 (2004) PER FBC 13-600.3.A . | | | | 2) 10" RETURN AIR TRANSFER DUCT TO | | MASTER SUITE IS TO SMALL, SEE NOTE #3 | | PLEASE CORRECT. | | | | 3) BALANCED RETURN AIR. | | THIS MAY BE ACHIEVED BY. | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | INCREASING THE RETURN TRANSFER ONE AND | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | (SQUARE INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM OR SPACE IT'S SERVING | | AND THE DOOR HAVING AT LEAST AN | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | PROPER RETURN AIR BALANCE. | | (B)TRANSFER GRILLES SHALL USE 50 | | SQUARE INCHES (OF GRILLE AREA) TO 100 | | CFM (OF SUPPLY AIR) FOR SIZING | | THROUGH-THE-WALL TRANSFER GRILLES AND | | USING AN UNRESTRICTED 1-INCH | | UNDERCUTTING OF DOORS TO ACHIEVE PROPER | | RETURN AIR BALANCE | | (C)HABITABLE ROOMS ONLY SHALL BE | | REQUIRED TO MEET THESE REQUIREMENTS FOR | | PROPER BALANCED RETURN AIR EXCLUDING | | BATHROOMS, CLOSETS, STORAGE ROOMS AND | | LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY | | AIR INTO THE MASTER SUITE SHALL BE | | INCLUDED. PER 2004 FBC/R M1602.4 . | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-07-28 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-07-28 |
Time |
14:41 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2006-07-28 |
Time |
14:41 |
Sent To |
P |
|
Notes |
2006-07-28 00:00:00 | *** DENIED *** | | 1) MECHANICAL PLANS NEED THE JOB ADDRESS | | ON THEM. | | | | 2) ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | PERSON RESPONSIBLE FOR THE DESIGN. PER | | FBC 104.2.1 . | | | | 3) SEE CONDENSER DETAIL, 18GA. STRAP IS | | NOT PERMITTED, MUST USE CLIPS, PLEASE | | CORRECT. | | | | 4) MECHANICAL PLANS MUST ALSO HAVE ON | | THEM THE A/C EQUIPMENT LISTING WITH ALL | | THE PERTINENT INFORMATION. | | | | 5) CLOTHES DRYER VENT TERMINATION MUST | | BE A MIN. OF 4 FT. FROM A/C CONDENSER | | UNIT, PER 2004 FBC/M 501.2 , PLEASE | | CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2007-01-16 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-01-16 |
Time |
11:36 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2007-01-16 |
Time |
11:36 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2006-10-21 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-10-21 |
Time |
13:42 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-10-21 |
Time |
13:42 |
Sent To |
B |
|
Notes |
2006-10-21 13:46:17 | SEALS ON PLANS ARE NOT CLEAR SEE ELECTRICAL PLAN REVIEW | | NOTE # 2. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-08-04 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-08-04 |
Time |
08:55 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-08-04 |
Time |
08:55 |
Sent To |
B |
|
Notes |
2006-08-04 00:00:00 | ******DENIED****** | | REFERENCE: FBC-2004 PLUMBING | | | | THE FOLLOWING CORRECTIONS ARE REQUIRED | | FOR PLUMBING PLAN REVIEW: | | | | 1) PLEASE SEE ELECTRICAL COMMENT #2. | | 2) PER FBC-2004 PLUMBING SECTION 708.9 | | ACCESS. ACCESS SHALL BE PROVIDED TO ALL | | CLEANOUTS. | | NOTE: CLEANOUT TO WASHING MACHINE SHALL | | BE LOCATED 4' AFF. PLEASE SEE SHEET A-5 | | CORRECTED ISOMETRIC PLUMBING RISER | | DIAGRAM IN RED INK FOR REFERENCE FOR | | RESUBMITTAL. | | | | **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN | | RESUBMITTING, PLEASE REPLACE ONLY SHEETS | | WHICH HAVE CHANGED, AND PROVIDE ONE COPY | | OF ALL OLD/VOIDED SHEETS FOR REFERENCE | | ONLY. NOTE: ONLY ONE CORRECTED DRAWING | | IN RED INK. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2007-04-04 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-04-04 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-04-04 |
Time |
15:58 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2007-01-07 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-01-07 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-01-07 |
Time |
16:17 |
Sent To |
I |
|
Notes |
2007-01-07 16:18:51 | ***FAILED*** | | | | 1) REAR SETBACK SHALL BE A MINIMUM OF 9 FEET (10% OF | | THE LOT DEPTH). | | | | 2) A MINIMUM OF 75 PERCENT OF THE FRONT YARD SHALL BE | | LANDSCAPED.THE SIZE OF THE PROPOSED DRIVEWAY WILL | | NEED TO BE REDUCED AS INSUFFICIENT LANDSCAPING IS BEING | | PROPOSED. | | | | QUESTIONS/COMMENTS, PLEASE CONTACT JOHN ROACH, SENIOR | | PLANNER, AT (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2006-10-11 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2006-10-11 |
Time |
11:36 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2006-10-11 |
Time |
11:36 |
Sent To |
I |
|
Notes |
2006-10-11 11:38:32 | ***FAILED*** | | | | 1) THE DIMENSIONS OF THE PROPOSED DRIVEWAY AND WALKWAY | | NEED TO BE SHOWN ON THE SURVEY. | | | | 2) AT LEAST 75% FO THE FRONT YARD (FIRST 25 FEET) SHALL | | BE LANDSCAPING. | | | | QUESTIONS/COMMENTS, PLEASE CONTACT JOHN ROACH, SENIOR | | PLANNER, AT (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-07-27 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-07-27 |
Time |
16:11 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-07-27 |
Time |
16:11 |
Sent To |
E |
|
Notes |
2006-07-27 00:00:00 | DENIED, | | 1. THE PROPOSED STRUCTURE MUST BE 25FT | | FROM THE FRONT SETBACK. | | 2. NEED TO PROVIDE THE DIMENSION OF THE | | PROPOSED DRIVEWAY & WALKWAY (LENGTH & | | WIDTH) | | | | NOTE:MUST MAINTAIN 1000SQ FT OR 75% OF | | LANDSCAPE, WHICHEVER IS LESS WITHIN THE | | FIRST 25FT FRONT SETBACK. | | | | 3. THE PROPOSED CONCRETE PATIO SHOULD BE | | SHOWN ON THE FLOOR PLAN A-2 | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|