Plan Review Stops For Permit 06071278 |
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
P |
Date |
2006-08-22 |
|
|
Cont ID |
|
Sent By |
lursu |
Date |
2006-08-22 |
Time |
14:43 |
Rev Time |
0.00 |
Received By |
lursu |
Date |
2006-08-22 |
Time |
14:43 |
Sent To |
|
|
Notes |
2006-08-22 00:00:00 | PERMIT MUST BE ATTACHED TO EXT #0002 , | | UNIT 100 ,WHERE THE JOB SITE IS LOCATED. |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
F |
Date |
2006-08-10 |
|
|
Cont ID |
|
Sent By |
lursu |
Date |
2006-08-10 |
Time |
09:09 |
Rev Time |
0.00 |
Received By |
lursu |
Date |
2006-08-10 |
Time |
09:09 |
Sent To |
|
|
Notes |
2006-08-10 00:00:00 | PROJECT UNDER REVIEW. |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2007-08-23 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-08-23 |
Time |
08:50 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-08-23 |
Time |
08:12 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2007-08-09 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-08-09 |
Time |
16:25 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-08-09 |
Time |
14:26 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-04-23 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-04-23 |
Time |
13:57 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-04-23 |
Time |
12:39 |
Sent To |
|
|
Notes |
2007-04-23 14:43:33 | BUILDING PLAN REVIEW | | PERMIT: 06071278 | | ADD: 2400CENTREPARK WEST #100 | | CONT: DAVCO ELECTRICAL CONTRACTORS, INC. | | TEL: (561)732-3434 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW 3RD | | ACTION: DENIED | | | | 1)61G1-16.004 TITLE BLOCK. INFORMATION REQUIRED ON | | TITLE BLOCK. | | A TITLE BLOCK MUST APPEAR ON ALL ARCHITECTURAL OR | | INTERIOR DESIGN DRAWINGS AND SPECIFICATION | | IDENTIFICATION SHEETS. THE TITLE BLOCK MUST, AT A | | MINIMUM, CONTAIN THE FOLLOWING INFORMATION: | | (1) FIRM NAME, ADDRESS, AND TELEPHONE NUMBER. | | (2) FIRM LICENSE NUMBER. | | (3) NAME OR IDENTIFICATION OF PROJECT. | | (4) DATE PREPARED. | | (5) A SPACE FOR THE SIGNATURE AND DATED SEAL. | | (6) A SPACE FOR THE PRINTED NAME OF THE PERSON SEALING | | THE DOCUMENT. | | | | 2)2004 FL. BLD CODE 1603.1.4 THE | | FOLLOWING INFORMATION RELATED TO WIND | | SHALL BE SHOWN ON THE CONSTRUCTION | | DRAWINGS, | | 1)- BASIC WIND SPEED, MPH | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | CATEGORY | | 3)- WIND EXPOSURE | | 4)- INTERNAL PRESSURE COEFFICIENT, | | 5)- COMPONENTS & CLADDING, THE DESIGN | | WIND PRESSURES IN TERMS OF PSF. | | | | 3)FL S S 713.13 | | NOTICE OF COMMENCEMENT, TO BE FILED WITH THE CLERK OF | | THE COURT. | | NOTE: 713.13(2) | | IF THE WORK DESCRIBED IN THE NOTICE OFCOMMENCEMENT IS | | NOT ACTUALLYCOMMENCED WITHIN 90 DAYS AFTER THE | | RECORDING THEREOF, SUCH NOTICE IS NULL & VOID. NOTE: | | 713.13(6)THE POSTING OF THE NOTICE OF COMMENCEMENT AT | | THE CONSTRUCTION SITE BEFORE THE FIRST INSPECTION. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2007-01-24 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2007-01-24 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2007-01-24 |
Time |
17:06 |
Sent To |
G |
|
Notes |
2007-01-24 17:32:30 | BUILDING PLAN REVIEW | | PERMIT: | | ADD: | | CONT: | | TEL: (561)###-#### | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | W/ 2006 FBC REVISIONS | | * WEST PALM BEACH AMENDMENTS | | | | REVIEW | | ACTION: DENIED | | | | 1)) GENERATOR SLAB & ANCHOR REQUIREMENT | | PLEASE PROVIDE SIZE OF GENERATOR(WXL), | | PLUS PROVIDE PLANS WITH THE INFORMATION | | DEPICTING HOLD DOWN BRACKETS, TYPE OF | | FASTENER, AND THE MINIMUM EDGE DISTANCE | | THE DEVICE REQUIRES WITHOUT LOAD | | REDUCTION. | | SECOND, PROVIDE INFORMATION ON THE | | SLAB, THICKNESS, WIDTH AND LENGTH, IF | | WIREMESH, FIBER MESH OR IF STEEL REBAR | | WILL BEUSED. | | THE NEW SLAB AND HOLD DOWN DETAILS: | | 104.2.1* ALL INFORMATION, DRAWINGS, | | SPECIFICATIONS AND ACCOMPANYING DATA | | SHALL BEAR THE NAME AND SIGNATURE OF THE | | PERSON RESPONSIBLE FOR THE DESIGN. | | | | 2) 2004 FL. BLD CODE 1603.1.4 THE | | FOLLOWING INFORMATION RELATED TO WIND | | SHALL BE SHOWN ON THE CONSTRUCTION | | DRAWINGS, | | 1)- BASIC WIND SPEED, MPH | | 2)- WIND IMPORTANCE FACTOR, & BUILDING | | CATEGORY | | 3)- WIND EXPOSURE | | 4)- INTERNAL PRESSURE COEFFICIENT, | | 5)- COMPONENTS & CLADDING, THE DESIGN | | WIND PRESSURES IN TERMS OF PSF. | | | | MYRON JACOBS | | BUILDING PLAN REVIEWER | | 805-6726 | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-08-10 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-08-10 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-08-10 |
Time |
16:40 |
Sent To |
|
|
Notes |
2006-08-10 00:00:00 | DENIED | | | | SHOW GENERATOR SLAB DETAIL AND METHOD OF | | ATTACHMENT TO SLAB. | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2007-08-14 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2007-08-14 |
Time |
17:34 |
Rev Time |
2.30 |
Received By |
jleahy |
Date |
2007-08-14 |
Time |
17:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2007-04-25 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2007-04-25 |
Time |
16:39 |
Rev Time |
3.00 |
Received By |
jleahy |
Date |
2007-04-25 |
Time |
16:39 |
Sent To |
|
|
Notes |
2007-04-25 16:50:08 | PANEL SCHEDULE "E | | | | SHOWS 2-P 70A BREAKER TO FEED TRANSFORMER | | | | RTU-3 SHOWS NO LOAD ON PANEL SCHEDULE. | | | | LOAD ON PANEL EXCEEDS GENERATOR OUTPUT (90 AMPERES) | | | | TWO OF THE LIGHTING LOADS ARE SHOWN AS 2-POLE 30A | | | | ALL DRAWINGS SHALL HAVE NAME OF PERSON WHO DID THE | | DESIGN | | | | PROVIDE LOADS THAT ARE ON IT PANEL FOR REVIEW. | | | | JAKE LEAHY |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-12-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-12-17 |
Time |
13:02 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-12-17 |
Time |
13:56 |
Sent To |
|
|
Notes |
2006-12-17 14:02:35 | **** UNSAT2ND REVIEW **** | | | | | | 1) NOTE: PLEASE SEE ALL COMMENTS WHICH WERE ATTACHED TO | | THE PERMITTED APPLICATION SUBMITTED ON THE FIRST | | REVIEW. PLEASE SEE PERMIT PACKAGE WAS SUBMITTEDBACK | | WITH ANY COMMENTS BEING ADDRESSED OR PLANS. | | PLEASE SEE RESPONSE ON COVER SHEET ONLY MENTIONS | | PLUMBING COMMENTS ADDRESSED. PLEASE KNOW COMMENTS FROM | | ALL TRADES MUST BE ADDRESS AND PLANS SUBMITTED | | ACCORDINGLY. | | | | 2) NOTE: PLEASE SEE FLORIDA STATUES 553.80(2)(B) WITH | | RESPECT TO REPEAT COMMENTS FOR CODE COMPLIANCE. | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-08-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-08-09 |
Time |
19:11 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-08-09 |
Time |
18:30 |
Sent To |
|
|
Notes |
2006-08-09 00:00:00 | ***** UNSAT **** | | | | 1) NOTE: PLEASE SEE THE 2002 NEC. | | 225.31-225.39, 230.72 | | PLEASE SEE THAT THIS OFFICE IS UNABLE TO | | VERIFY THIS AT THIS TIME. | | | | 2) NOTE: PLEASE INDICATE ANY AND ALL | | CONTINUOOUS LOADS AT 125%. | | 215.3,230.42 ETC. | | | | 3) NOTE: PLEASE UPDATE PANEL SCHEDULES | | AS THE PANELS DID NOT SEEM TO GET ALL | | THE NEW CIRCUITS. "E". 408.4 | | 106.1.2 FBC ADMIN SECT | | | | 4) NOTE: PLEASE PROVIDE A LAYOUT OF ALL | | SERVICE EQUIPMENT. PLEASE PROVIDE AN | | OVERVIEW AS NO ELECTRICAL EQUIPMENT IS | | SHOWN. CAN NOT VERIFY ITEMS IN NOTE #1 | | AT THIS TIME. | | | | 5) NOTE: PLEASE SUBMIT SPECS/CUT SHEETS | | FROM THE MANUFACTURE FOR THE ATS. | | 110.3, 90.8 | | PLEASE ALSO SUBMIT THE SPECS/SHEETS FOR | | THE WP HOUSING AS THE GEN DOES NOT SHOW | | THIS. | | | | 6) NOTE: PLEASE CORRLELATE THE OCP FOR | | THE NEW TRANSFORMER AS THE PANEL SHOWS | | ONE AND THE RISER SHOWS ANOTHER. | | 450.3, | | FBC 106.1.2 | | | | 7) NOTE: PLEASE PROVIDE GROUNDING OF THE | | NEW TRANSFORMER. | | 250.30,250.20,250.66 ETC | | | | 8) NOTE: PLEASE SEE PLANS/DRAWINGS ARE | | NOT REQUIRED TO BE NOTARIZED, HOWEVER IF | | THEY ARE THEN THEY NEED TO BE CORRECTLY | | NOTARIZED AS REQUIRED PERFS 117.05 | | PLEASE KNOW ONLY A STAMP AND SIGNATURE | | IS NOT ACCEPTABLE. | | | | 9) NOTE: PLEASE SEE EXISTING MDP, IS | | BEING SHOWN AS MLO. PLEASE CLARIFY AS | | THIS CONTAINS MANY MORE THAN 6 MEANS OF | | DISCONNECT. 230.70 | | PLEASE KNOW, ALL DISCONNECTING MEANS FOR | | SEC'S AND FEEDERS COMING INTO THE | | BUILDING SHALL BE GROUPED. | | | | 10) NOTE: PLEASE PROVIDE PROPER LEGAL | | DOCUMENTATION THAT THIS GENERATOR ECT IS | | BEING PERMITTED ON THIS PROPERTY BY THE | | PROPERTY OWNER. | | PLEASE SEE THIS GEN SEEMS TO BE ONLY FOR | | ONE TENANT SPACEIN THE BUIDLING. | | | | 11) NOTE: PLEASE SEE ALL PLANS, DESIGNS | | AND LOAD CALULATIONS SHALL CONTAIN A | | STATEMENT" DRAWN BY: PRINTED NAME AND | | SIGNATURE OF THE PERSON RESPSOSIBLE FOR | | SAID PLANS AND DESIGNS. | | FBC 106.1.2 | | | | | | ** UNABLE TO DO A COMPLETE REVIEW AT | | THIS TIME AS THERE ARE SOME MISSING | | ITEMS NEEDED. | | PLEASE BE SURE TO GO OVER PLANS AND | | RISER BEFORE RESUBMITTING. | | | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
P |
Date |
2007-08-20 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-08-20 |
Time |
16:36 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-08-20 |
Time |
16:29 |
Sent To |
Z |
|
Notes |
2007-08-20 16:35:53 | *****APPROVED***** | | | | | | THE PREVIOUS FIRE PLAN REVIEW COMMENTS HAVE BEEN | | ADDRESSED;PLAN SHEET SP-1 STAMPED, INITIALED, AND | | DATED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
F |
Date |
2007-05-07 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-05-07 |
Time |
16:02 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-05-07 |
Time |
15:53 |
Sent To |
|
|
Notes |
2007-05-07 16:02:02 | *****DENIED***** | | | | | | | | PLEASE BE ADVISED THAT THE PLAN REVIEW COMMENTS OF | | 09/05/2006 HAVE NOT BEEN ADDRESSED.(SEE RE-PRINT) | | | | TO EXPEDITE THE PLAN REVIEW PROCESS WHEN RESUBMITTING, | | INCLUDE A RESPONSE LETTER INDICATING HOW/WHERE EACH | | ITEM WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
F |
Date |
2007-01-08 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-01-08 |
Time |
13:25 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-01-08 |
Time |
13:25 |
Sent To |
|
|
Notes |
2007-01-08 13:30:55 | *****DENIED***** | | | | | | | | PLEASE BE ADVISED THAT THE PLAN REVIEW COMMENTS OF | | 09/05/2006 HAVE NOT BEEN ADDRESSED.(SEE RE-PRINT) | | | | TO EXPEDITE THE PLAN REVIEW PROCESS WHEN RESUBMITTING, | | INCLUDE A RESPONSE LETTER INDICATING HOW/WHERE EACH | | ITEM WAS ADDRESSED | | | | | | CAPT. MICHAEL A. WILLIAMS | | FIRE PLAN REVIEW | | 561-805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2006-09-05 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-09-05 |
Time |
10:33 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-09-05 |
Time |
10:33 |
Sent To |
|
|
Notes |
2006-09-05 00:00:00 | ***DENIED*** | | | | 1) PLEASE ILLUSTRATE BUILDING OPENINGS | | AS IT RELATES TO THE LOCATION OF THE | | GENERATOR. | | | | 2) WORK TO COMPLY WITH NFPA 110, | | STANDARD FOR EMERGENCY AND STANDBY POWER | | SYSTEMS. | | | | 3) PLEASE PROVIDE VERIFICATION AS TO | | FUEL SOURCE, NATURAL GAS OR PROPANE. | | SPEC SHEETS INDICATE SEVERAL OPTIONS. | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
P |
Date |
2007-08-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-08-17 |
Time |
13:56 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-08-17 |
Time |
13:56 |
Sent To |
|
|
Notes |
2007-08-17 13:56:51 | GAS PERMIT TO BE ISSUED WHEN ZONING APPROVAL AND | | GEN-COM IS ISSUED |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
F |
Date |
2007-06-04 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-06-04 |
Time |
15:13 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-06-04 |
Time |
15:12 |
Sent To |
|
|
Notes |
2007-06-04 16:02:55 | GAS PLANS CORRECT, BUT WILL NOT BE PASSED IN THE | | COMPUTER UNTILL ZONING APPROVAL |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
F |
Date |
2007-03-06 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2007-03-06 |
Time |
08:48 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2007-03-06 |
Time |
08:48 |
Sent To |
PC |
|
Notes |
2007-03-06 10:14:25 | DENIED | | REFERENCE: FBC-2004 FUEL GAS: | | | | ** PLEASE SEE SOME NOTES FROM PREVIOUS REVIEW ARE STILL | | IN NEED OF ADDRESSING ALONG WITH SOME NEW COMMENTS, | | SOME BASED ON PLANS NOW SUBMITTED, NEW DOCUMENTS BEING | | REVIEWED FOR THE FIRST TIME AND SOME NEW COMMENTS NOT | | MADE ON PREVIOUS REVIEWS. | | | | ** PLEASE SEE THE NOTES BELOW ARE TAKEN DIRECTLY FROM | | PREVIOUS REVIEW WITH A NO, OK OR A NO/OK. | | THESE WILL BE FOR THE EXACT NUMERICAL NOTATION OF THE | | PREVIOUS REVIEW NOTES. | | | | A NO IS IF THE COMMENT WAS NOT FULLY ADDRESSED AND/OR | | FURTHER EXPLANATION OR CHANGES IN PLANS OR DOCUMENTS | | ARE STILL NEEDED. THIS REVIEWER WILL TRY TO BETTER | | EXPLAIN NOTE ABOVE PREVIOUS REVIEW COMMENT. | | | | AN OK WILL BE LABELED AS SUCH ON THE SAME NUMERICAL | | COMMENT AND WILL HAVE OLD NOTE REMOVED FROM COMMENTS. | | | | A NO/OK MEANS PART OF THE COMMENT MAY HAVE BEEN | | ADDRESSED, HOWEVER NOT ALL OF THE PREVIOUS REVIEW | | COMMENT MAY HAVE BEEN FULLY ADDRESSED. | | | | ** PLEASE SEE ANY NEW NOTES WILL BE ADDED TO THE END OF | | THE PREVIOUS REVIEW COMMENTS AND NOTED AS SUCH. | | | | THE FOLLOWING ARE FROM THE PREVIOUS REVIEW DATED | | 8/21/06 | | | | 1. OK | | 2. OK | | 3. OK | | 4. OK | | 5. OK | | 6. OK | | 7. NO,SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | STANDARDS NFPA 54, NFPA 58, AND THE | | FBC-2004 FUEL GAS CODE SEC 402.2 | | NOTE: PLEASE PROVIDE MANUFACTURER SHEETS FOR THE | | FOLLOWING. | | A} MP REGULATOR | | B} GENERATOR | | 9. OK, N/A | | 10. OK, N/A | | | | THE FOLLOWING ARE NEW COMMENTS: | | | | 11. PLEASE PROVIDE 2 COPIES OF SITE PLAN OR SURVEY AT | | THE TIME OF PERMIT APPLICATION THAT INCLUDE THE | | FOLOWING INFORMATION. | | A} THE CLEARLY MARKED PROPOSED LOCATION FOR THE | | INSTALLATION OF THE GENERATOR. | | B} INDICATION OF ALL DIMENTIONS FROM PROPERTY LINES | | AND DISTANCES FROM ADJACENT DWELLING STRUCTURES. | | C} INDICATION THAT THE GENERATOR EXHAUST IS NOT | | INSTALLED CLOSER THAN TEN FEET FROM ANY OPENING INTO | | THE DWELLING STRUCTURE. THIS INCLCES DOORS, WINDOWS AND | | ATTIC VENTILATION OPENINGS. | | | | 12. PLEASE SUBMIT TWO COPIES OF THE MANUFACTURER'S | | SPECIFICATIONS/CUT SHEETS FOR GENERATOR, SHOWING | | LISTINGS FROM A NATIONALLY RECOGNIZED TESTING | | LABORATORY (NRTL). PLEASE INCLUDE INSTALLATIN | | INSTRUCTIONS INDICATING CLEARENCES TO DWELLINGS. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2006-08-21 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2006-08-21 |
Time |
10:43 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2006-08-21 |
Time |
10:43 |
Sent To |
|
|
Notes |
2006-08-21 00:00:00 | SEPARATE GAS PERMIT REQUIRED | | | | THE FOLLOWING INFORMATION IS REQUIRED | | FOR THE GAS PERMIT: | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2004 | | FUEL GAS CODE. | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | NUMBER OF CORRUGATED STAINLESS STEEL | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | 3. TYPE OF GAS, (LP OR NATURAL) MANUF. | | SHEETS INDICATE EITHER NATURAL, LP, OR | | BOTH, (DUAL FUEL). PLEASE BE SPECIFIC. | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | 402.4(33). (INDICATE IF CONNECTING TO | | EXISTING. - IF EXISTING SYSTEM PLEASE | | INDICATE BTU'S FOR ALL EXISTING (TOTAL) | | AND DISTANCE FROM METER TO MOST REMOTE | | APPLIANCE IN EXISTING). | | | | 5. SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES A.3.1(4). (INCLUDING | | EXISTING IF APPLICABLE). | | | | 6. INDICATE THE DELIVERY PRESSURE (PSI) | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | 7. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | STANDARDS NFPA 54, NFPA 58, AND THE | | FBC-2004 FUEL GAS CODE SEC 402.2. MANUF. | | SHEETS SUBMITTED DO NOT CONTAIN THE | | INSTALLATION INSTRUCTIONS WITH MINIMUM | | CLEARANCE REQUIREMENTS FROM STRUCTURES | | FOR SERVICE ETC. | | | | 9. CLEARLY SHOW THE LOCATION AND CAP- | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | OR ASME), THE DISTANCE OF THE TANK FROM | | THE BUILDING AND ADJACENT PROPERTY LINES | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | INGS, AND THE LOCATION OF ANY BUILDING | | OPENINGS BELOW THE RELIEF VALVE OF THE | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | 10. CLEARLY INDICATE ON THE PLAN IF THE | | LP TANK IS ABOVE OR BELOW GROUND, AND | | SHOW REQUIRED PROTECTION OF THE TANK AND | | APPURTENANCES PER NFPA 58. IF THE TANK | | IS BELOW GROUND THE CONTAINER SHALL BE | | SECURILY ANCHORED PER NFPA 58 SECTION | | 3-2.2.7(H). | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-07-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-20 |
Time |
09:30 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-20 |
Time |
09:30 |
Sent To |
|
|
Notes |
2007-08-01 13:21:47 | TO "COMM" BD#8 | 2007-07-20 09:31:04 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-04-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-04-20 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-04-20 |
Time |
16:37 |
Sent To |
|
|
Notes |
2007-04-20 16:38:04 | TO "COMM' BD#12 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-12-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-12-01 |
Time |
10:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-12-01 |
Time |
10:47 |
Sent To |
|
|
Notes |
2006-12-13 15:03:24 | TO "COMM" BD#25 | 2006-12-01 10:47:30 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-09-05 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-09-05 |
Time |
10:39 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-07-22 |
Time |
17:04 |
Sent To |
|
|
Notes |
2006-08-08 00:00:00 | TO "COMM" BD#26 | 2006-07-22 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2006-08-21 |
|
|
Cont ID |
|
Sent By |
pkrauss |
Date |
2006-08-21 |
Time |
09:50 |
Rev Time |
0.00 |
Received By |
pkrauss |
Date |
2006-08-21 |
Time |
09:08 |
Sent To |
|
|
Notes |
2006-08-21 00:00:00 | NATURAL GAS GENERATOR: | | SITE PLANS DO NOT INDICATE DISTANCES OR | | CLEARANCES FROM PROPERTY LINES, | | BUILDING, FRESH AIR INTAKES, WINDOWS, | | DOORS, ETC. | | | | PLEASE PROVIDE ANCHORING DETAIL. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT PATTY KRAUSS AT (561)805-6719 OR | | E-MAIL [email protected]. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
5 |
Status |
P |
Date |
2007-08-22 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-08-22 |
Time |
09:31 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-08-22 |
Time |
09:31 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
F |
Date |
2007-08-13 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-08-13 |
Time |
21:31 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-08-13 |
Time |
21:31 |
Sent To |
|
|
Notes |
2007-08-13 21:35:20 | ***FAILED*** | | | | 1) PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, A MINOR | | AMENDMENT TO THE CENTREPARK WEST COMMERCIAL PLANNED | | DEVELOPMENT (CPD) SHALL BE SUBMITTED TO AND APPROVED BY | | THE PLANNING AND ZONING DEPARTMENT.APPLICATION HAS | | BEEN SUBMITTED FOR THE MINOR AMENDMENT.HOWEVER, | | OUTSTANDING COMMENTS REGARDING THIS APPLICATION HAVE | | NOT YET BEEN ADDRESSED TO RECEIVE APPROVAL. | | | | 2) ADEQUATE SCREENING SHALL BE PROVIDED, CONSISTING OF | | A SOLID WALL OF ADEQUATE HEIGHT LANDSCAPED WITH | | SHRUBS/HEDGES AT TWO (2) FOOT INTERVALS.LANDSCAPE | | PLANS WERE SUBMITTED AS PART OF THE MINOR AMENDMENT. | | HOWEVER, NO PLANS WERE SUBMITTED AS PART OF THE | | BUILDING PERMIT.ENSURE THAT THE COMMENTS FROM THE | | MINOR AMENDMENT REVIEW HAVE BEEN SUFFICIENTLY ADDRESSED | | (I.E. RELOCATION OF AN EXISTING SHADE TREE). | | | | ONCE THE MINOR AMENDMENT IS APPROVED, AND ALL PLANS | | SUBMITTED AS PART OF THE BUILDING PERMIT MATCH THOSE, | | THE PERMIT WILL BE APPROVED. | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | AT (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2007-04-30 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-04-30 |
Time |
10:29 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-04-30 |
Time |
10:29 |
Sent To |
|
|
Notes |
2007-04-30 10:30:54 | ***FAILED*** | | | | 1) PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, A MINOR | | AMENDMENT TO THE CENTREPARK WEST COMMERCIAL PLANNED | | DEVELOPMENT (CPD) SHALL BE SUBMITTED TO AND APPROVED BY | | THE PLANNING AND ZONING DEPARTMENT. | | | | 2) ADEQUATE SCREENING SHALL BE PROVIDED, CONSISTING OF | | A SOLID WALL OF ADEQUATE HEIGHT LANDSCAPED WITH | | SHRUBS/HEDGES AT TWO (2) FOOT INTERVALS. | | | | 3) NO SURVEYS WERE PROVIDED WITH THE RESUBMITTAL.TWO | | (2) COPIES OF A CURRENT SURVEY SHALL BE PROVIDED | | SHOWING THE LOCATION OF THE GENERATOR WITH THE SETBACKS | | FROM THE PROPERTY LINES. | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | AT (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2007-01-07 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2007-01-07 |
Time |
22:10 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2007-01-07 |
Time |
22:10 |
Sent To |
|
|
Notes |
2007-01-07 22:11:37 | ***FAILED*** | | | | 1) PRIOR TO THE ISSUANCE OF A BUILDING PERMIT, A MINOR | | AMENDMENT TO THE CENTREPARK WEST COMMERCIAL PLANNED | | DEVELOPMENT (CPD) SHALL BE SUBMITTED TO AND APPROVED BY | | THE PLANNING AND ZONING DEPARTMENT. | | | | 2) ADEQUATE SCREENING SHALL BE PROVIDED, CONSISTING OF | | A SOLID WALL OF ADEQUATE HEIGHT LANDSCAPED WITH | | SHRUBS/HEDGES AT TWO (2) FOOT INTERVALS. | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, SENIOR PLANNER, | | AT (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-08-17 |
|
|
Cont ID |
|
Sent By |
jroach |
Date |
2006-08-17 |
Time |
08:42 |
Rev Time |
0.00 |
Received By |
jroach |
Date |
2006-08-17 |
Time |
08:42 |
Sent To |
|
|
Notes |
2006-08-17 00:00:00 | 8/17/06 ***FAILED*** | | | | 1) PRIOR TO THE ISSUANCE OF A BUILDING | | PERMIT, A MINOR AMENDMENT TO THE | | CENTREPARK WEST COMMERCIAL PLANNED | | DEVELOPMENT (CPD) SHALL BE SUBMITTED TO | | AND APPROVED BY THE PLANNING AND ZONING | | DEPARTMENT. | | | | 2) ADEQUATE SCREENING SHALL BE PROVIDED, | | CONSISTING OF A SOLID WALL OF ADEQUATE | | HEIGHT LANDSCAPED WITH SHRUBS/HEDGES AT | | TWO (2) FOOT INTERVALS. | | | | QUESTIONS/COMMENTS, CONTACT JOHN ROACH, | | SENIOR PLANNER, AT (561) 822-1435. | | |
|
|