Plan Review Details - Permit 06071193
Plan Review Stops For Permit 06071193
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-08-16 Cont ID  
Sent By shill Date 2006-08-16 Time 11:07 Rev Time 0.00
Received By shill Date 2006-08-14 Time 12:55 Sent To  
Notes
2006-08-16 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBCFLORIDA BUILDING CODE 2004
 BUILDING
 FBC RFLORIDA BUILDING CODE 2004
 RESIDENTIAL
 FBC EBFLORIDA BUILDING CODE 2004
 EXISTING BUILDING CODE
 FBC*CITY OF WEST PALM BEACH
 AMENDMENTS TO THE FBC2004
  
  
 1.)A NOTICE OF COMMENCEMENT MUST BE
 FILED WITH THE CLERK OF COURTS BEFORE A
 PERMIT CAN BE ISSUED, FS713.13.A NEW
 NOC WILL BE REQUIRED FOR THE NEW
 CONTRACTOR.
  
 2.)THE CONTRACTOR HAS CARPENTRY
 CONTRACTOR AND A WINDOW AND DOOR
 CONTRACTOR LICENSES.THE SCOPE OF WORK
 FOR THIS PROJECT EXCEEDS THE SCOPE OF
 THESE LICENSES (DRYWALL, PAINT, MASONRY,
 CONCRETE, ETC.).SEE ATTACHED FOR WORK
 ALLOWED UNDER THESE LICENSES.
  
 3.)WHEN APPLYING FOR PERMITS, ONLY
 REFER TO ONE LICENSE NUMBER.IF THE
 SCOPE OF WORK INCLUDES BOTH LICENSES,
 TWO PERMIT APPLICATIONS SHOULD BE
 COMPLETED WITH TWO DIFFERENT PERMIT
 NUMBERS GENERATED.
  
 4.)A WINDOW AND DOOR PERMIT HAS BEEN
 ISSUED FOR THIS ADDRESS.THE PLANS SHOW
 THE WINDOWS AND DOORS AS EXISTING.NOTE
 THAT AS THE CONTRACTOR DID NOT ADVISE
 THAT THERE WAS TO BE A CHANGE OF
 OCCUPANCY, THE CONTRACTOR IS PROCEEDING
 AT HIS OR HER OWN RISK AS THAT PLAN WAS
 NOT REVIEWED FOR ACCESSIBILITY, TABLE
 602, AND EGRESS REQUIREMENTS.
  
 5.)THE PLANS STATE THAT THIS IS A
 REMODEL MODIFICATION OF AN EXISTING
 RESIDENCE TO DR. SCHWARZ PSYCHIATRY
 FUNCTION.THIS IS A CHANGE OF
 OCCUPANCY, FROM R3 TO BUSINESS.REMOVE
 ALL REFERENCES TO RESIDENCES AND
 RESIDENTIAL CODE FROM THE PLAN AS THEY
 DO NOT APPLY TO THIS JOB.CHANGE OF
 OCCUPANCY IS TO COMPLY WITH ALL
 REQUIREMENTS OF FLORIDA BUILDING CODE
 2004 EXISTING BUILDING CODE, CHAPTERS 5
 THROUGH 8 AND FLORIDA BUILDING CODE
 2004, BUILDING, 11-4.1.6.
  
 6.)MANY OF THE NOTES ON THE SITE PLAN
 DO NOT APPLY TO THIS JOB.REMOVE FROM
 THE PLAN.
  
 7.)PROVIDE A CODE SUMMARY OF THE
 EXISTING BUILDING; BUILDING HEIGHT,
 CONSTRUCTION TYPE INCLUDING A OR B FBC
 6, FIRE SPRINKLER INFORMATION, GOVERNING
 CODE INCLUDING FBC EB, OCCUPANCY FBC3.
  
  
 8.)PROVIDE AREA CALCULATIONS FOR THE
 STORAGE AREAS.SEE FBC302.1.1, 302.2,
 AND TABLE 302.1.1.
  
 9.)PROVIDE AREA CALCULATIONS;
 EXISTING, PROPOSED NEW, NEW TOTAL.IT
 APPEARS THAT YOU ARE CONVERTING
 UNINHABITABLE SPACE TO BECOME HABITABLE;
 THE AREA CALCULATIONS SHOULD REFLECT
 THIS.THIS IS USED FOR ASSESSMENT OF
 IMPACT FEES BY PALM BEACH COUNTY.
 FAILURE TO PROPERLY ADDRESS THIS WILL
 RESULT IN DELAYS.IF YOU DO NOT
 UNDERSTAND WHAT IS REQUIRED, PLEASE
 CONTACT ME.
  
 10.)IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY, CHANGE OF USE.233-5025
 FOR MORE INFORMATION.
  
 11.)SHOW COMPLIANCE WITH FBC TABLE
 503.
  
 12.)PROVIDE A COPY OF THE SURVEY OF
 THIS PROPERTY SO THAT FBC TABLE 601
 COMPLIANCE CAN BE DETERMINED,
 FBC*106.3.4, FBC EB812.1, FBC704,
 FBC704.5.
  
 13.)INFORMATIONAL ONLY; DUE TO THE
 LACK OF INFORMATION ON THE PLAN, A
 SECOND ROUND OF COMMENTS IS LIKELY.
  
 14.)THE SITE PLAN IS NOT SIGNED AND
 SEALED.THIS IS REQUIRED AS THIS PAGE
 IS REQUIRED TO SHOW CODE COMPLIANCE.
  
 15.)THE SITE PLAN HAS A NOTE, SUBJECT
 MEDICAL USE SHALL BE LIMITED USE PER
 TYPE 1 CATEGORY.WHAT DOES THIS MEAN?
  
 16.)THE SITE PLAN DOES NOT PROVIDE A
 DESIGNATION FOR THE REAR BUILDING.IT
 APPEARS TO BE A GARAGE.CLEARLY
 INDICATE USE FOR THIS STRUCTURE, FBC11.
  
 17.)THE REROOF PERMIT FOR THE HOUSE
 AND GARAGE ARE EXPIRED, PERMIT NUMBER
 99081195.PLEASE ADDRESS.
  
 18.)THE SITE PLAN DOES NOT SHOW THE
 EXIT RAMP SHOWN ON SHEET 2.
  
 19.)GENERAL PROJECT NOTES DESIGN
 CRITERIA REFERS TO 3 SECOND GUESTS.
 PLEASE REVISE.IT APPEARS THAT YOU ARE
 STATING WIND DESIGN CRITERIA, SEE
 FBC1603.1.4 AND PROVIDE ALL INFORMATION.
  
 20.)HAS RAUL LESCANO PE SIGNED THE
 PLANS?SEE FAC61G15-23.002.IT APPEARS
 THAT SOMEONE ELSE HAS SIGNED ON HIS
 BEHALF.THE ENGINEER IS TO SIGN, SEAL,
 AND DATE ALL DOCUMENTS.
  
 21.)ARE THE ROOM DESIGNATIONS LABELED
 CORRECTLY?THE EXISTING SHOWS A WAITING
 ROOM, NOW A SITTING ROOM.THIS DOES NOT
 APPEAR APPROPRIATE FOR BUSINESS USE.
 THERE ARE TWO EXISTING SECOND FLOOR
 PLANS.NO KITCHEN IS SHOWN ANYWHERE ON
 THE PLAN, NO BATHTUB OR SHOWER IS SHOWN.
 IF THIS IS CURRENTLY A RESIDENCE, ISN?T
 THERE A KITCHEN AND BATH WHICH REQUIRES
 DEMOLITION?PLEASE LABEL ALL ROOMS
 CORRECTLY AS TO USE AND REVISE PLANS TO
 ADDRESS INCONSISTENCIES.
  
 22.)WHAT WILL BE STORED IN THE STORAGE
 ROOM?
  
 23.)PRODUCT APPROVALS ARE TO BE
 APPROVED BY DESIGNER OF RECORD,
 FBC*106.3.3.
  
 24.)DECLARE AN OCCUPANCY, FBC 3.
  
 25.)DECLARE OCCUPANT LOAD, FBC1004.
  
 26.)DECLARE OCCUPANT LOAD FOR THE
 SECOND FLOOR.VERTICAL ACCESSIBILITY
 REQUIRED UNLESS EXCEPTED, FBC11-4.1.6.
 GENERAL PROJECT NOTES STATES THAT AN
 ELEVATOR WILL BE INSTALLED BUT NONE
 SHOWN ON THE PLAN.
  
 27.)PARKING IS TO COMPLY WITH CITY OF
 WEST PALM BEACH STANDARD, SEE ATTACHED.
 PROVIDE A DETAIL ON THE PLAN.
  
 28.)SHOW THE ACCESSIBLE ROUTE FROM THE
 PUBLIC WAY, FBC11-4.1.2(1).PROVIDE
 WIDTH, ELEVATION CHANGES.
  
 29.)SHOW THE ACCESSIBLE ROUTE FROM THE
 ACCESSIBLE PARKING SPACE IN THE REAR TO
 THE OFFICE.THE ACCESSIBLE PARKING
 SPACE IS TO COMPLY WITH FBC11-4.6.2.NO
 ACCESS AISLE IS SHOWN FBC11-4.3, NO
 DETAIL FOR THE ACCESSIBLE PARKING
 PROVIDED.
  
 30.)IT IS NOT CLEAR WHY THE RAMP GOES
 TO A STORAGE ROOM; IS THIS A LOADING
 RAMP RATHER THAN A RAMP FOR
 ACCESSIBILITY, FBC1 1-4.8?ACCESSIBLE
 RAMPS ARE TO HAVE A LANDING AT THE TOP
 AND BOTTOM, FBC11-4.8.4.
  
 31.)MEANS OF EGRESS CANNOT GO THROUGH
 A BATHROOM (A ROOM THAT CAN BE LOCKED)
 OR ASTORAGE ROOM, FBC1013.2.IT IS
 NOT CLEAR WHERE THE ACCESSIBLE ENTRANCE
 IS.
  
 32.)PROVIDE A LIFE SAFETY PLAN FOR
 BOTH THE FIRST AND SECOND FLOOR.THE
 DIMENSIONS FOR ALL MEANS OF EGRESS WHICH
 ARE CURRENTLY SHOWN AS EXISTING IS
 REQUIRED; DOORWAYS, STAIRS, FBC CHAPTER
 10.OVERALL DIMENSIONS ARE NOT SHOWN ON
 THE FLOOR PLAN.
  
 33.)SHOW EXIT LIGHTS IN COMPLIANCE
 WITH FBC1006.3.
  
 34.)PROVIDE A DETAIL AND A SECTION FOR
 THE EXISTING STAIRS SHOWING CONSTRUCTION
 AND ALL DIMENSIONS, INCLUDING HEAD
 CLEARANCE AND LANDING SIZE, FBC 1009,
 FBC11-4.9.
  
 35.)PROVIDE A HANDRAIL AND GUARDRAIL
 (IF APPLICABLE) DETAIL FOR THE STAIRS,
 FBC1012, FBC1009, FBC11-4.9.4.
  
 36.)THE ENTRY DOOR DOES NOT APPEAR TO
 COMPLY WITH FBC11-4.13.4, DOUBLE-LEAF
 DOORWAYS.
  
 37.)SECOND FLOOR EXISTING BATH IS TO
 BE ACCESSIBLE.PROVIDE ALL DETAILS, ALL
 DIMENSIONS, FOR BOTH BATHROOMS, FIRST
 AND SECOND FLOOR, RELATED TO
 ACCESSIBILITY; TOILET, GRAB BARS,
 TURNING RADIUS, SINK, CLEAR FLOOR SPACE
 FOR FIXTURES.
  
 38.)THE SECOND FLOOR BATH DOOR
 ENCROACHES INTO THE CLEAR FLOOR SPACE
 FOR THE SINK, FBC11-4.24.5.
  
 39.)AN EXISTING A/C VENT IS SHOWN IN
 THE NEW BATH.IS THIS IN THE FLOOR?
 GRATING IS TO COMPLY WITH FBC11-4.5.4.
  
 40.)DOORS ARE TO COMPLY WITH
 MANEUVERING CLEARANCE, FBC11-4.13.6, FBC
 FIGURE 11-25.THE FOLLOWING DOORS DO
 NOT APPEAR TO COMPLY WITH THE PULL SIDE
 MANEUVERING CLEARANCE REQUIREMENT; FIRST
 FLOOR STORAGE EXTERIOR NEW DOOR, NEW
 BATH EXTERIOR DOOR, SECOND FLOOR
 EXISTING SITTING ROOM, EXISTING LIBRARY
 CLOSET DOOR.
  
 41.)HOW DOES THE LINTEL TIE INTO THE
 EXISTING?AS DRAWN, IT SITS ON TOP OF
 TWO NEW COLUMNS BUT IS NOT STRUCTURALLY
 CONNECTED.
  
 42.)PROVIDE DESIGN LOAD INFORMATION
 FOR THE LINTEL, LINTEL SIZE AND REBAR
 INFORMATION.
  
 43.)PROVIDE DESIGN LOAD INFORMATION
 FOR THE FIRST FLOOR, SECOND FLOOR, AND
 STAIRS.CERTIFY THAT THE EXISTING
 FLOORS AND STAIRS COMPLY WITH THE NEW
 DESIGN LOAD REQUIREMENTS.
  
 44.)FBC*110.1.1, CERTIFICATE OF
 OCCUPANCY REQUIRED AS THIS IS A CHANGE
 FROM R3 TO B.
  
 45.)INFORMATIONAL - CODE COMPLIANCE
 CANNOT BE SHOWN BY REFERRING TO CODE
 SECTIONS ONLY.DESIGNER IS TO PROVIDE
 DESIGN CRITERIA WITH DETAILS, NOT CODE
 REFERENCES.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-08-10 Cont ID  
Sent By dpalmer Date 2006-08-10 Time 09:40 Rev Time 0.00
Received By dpalmer Date 2006-08-10 Time 08:47 Sent To  
Notes
2006-08-10 00:00:00****UNSAT ****
  
 1) NOTE: PLEASE SEE THAT PLANS REFLECT
 ALL OF THE FOLLOWING CODES AT A MINIMUM.
 2004 FBC, 2002 NFPA-70, 2002 NFPA-72,
 2003 NFPA-101
  
 2) NOTE: PLEASE SUBMIT PLANS WHICH ARE
 DONE BY A MINIMUM OF AN ARCHITECT,
 SIGNED, DATED AND SEALED BY SAID
 PROFESSIONAL. PLEASE ALSO BE SURE ALL
 TITLE BLOCK INFORMATION IS ON SAID
 PLANS.
 FS 481.229, 481.221, 471.025
 FAC 61G15-23.002, 61G1-16.004.
  
 3) NOTE: PLEASE SSUBMIT ELECTRICAL PLANS
 IN COMPLIANCE WITH THE 2002 NEC.
 PLEASE SEE PLANS FOR SERVICE DO NOT
 CORRELATE, PLEASE SEE LOAD CALCULATIONS
 ARE NOT CORRECT AND THERE ARE MANY ITEMS
 MISSING.
 PLEASE SEE 2002 NEC,
 220.3,220.10,220.11,220.13, ETC, 215.5,
 215.3, 230.42, ETC
  
 4) NOTE: PLEASE SEE MISSING EXIT AND
 EMERGENCY LTS REQUIRED.
 PLEASE ALSO SEE FIRE REVIEW COMMENTS.
 PLEASE SEE NFPA-101 2003 7.8.1.3,
 7.9.2.2 AS THE MIN FT CANDLES REQUIRE
 UNDER NORMAL LIGHTING LEVELS ON THE
 STAIRS AND THE MIN LEVELS REQUIRED UNDER
 EM PWR(BATTERY BACK UP).
 PLEASE ALSO SEE ANY OPENING LEADING TO
 DIRECT GRADE LEVEL ACCESS SHALL ALSO
 CONTAIN CONTROL FOR EGRESS LTS.
  
 ** PLEASE SEE COMMENTS FROM OTHER TRADES
 WHICH AMY HAVE AN AFFECT ON ELECTRICAL
 PLANS.
  
 ** IMPORTANT**
 ONCE ALL REVIEWS ARE DONE AND PLANS ARE
 PICKED UP FOR CORRECTIONS, PLEASE BE
 SURE TO COMPLETELY REMOVE ALL OLD/VOIDED
 SHEETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO COMPLETE SETS FOR REVIEW
 AND STAMPING. DO NOT LEAVE ANY
 OLD/VOIDED SHEETS IN SETS.
 PLEASE KNOW ONLY ONE SET OF THE
 OLD/VOIDED SHEETS SHOULD BE SUBMITTED
 FOR REFERENCE.
 THIS WILL HELP IN THE REVIEW PROCESS AND
 AVOID ANY DELAYS.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CONSTUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  
  
  
  
  
2006-07-23 00:00:00*** THIS IS NOT RESIDENTIAL. THIS IS A
 CHANGE IN OCCUPANCY AND PLANS ARE BEING
 ROUTED BACK TOINCOMING.
 PERMIT TYPE HAS BEEN CHANGED IN COMPUTER
 AND FEES ADDED FOR FIRE REVIEW.

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2006-09-07 Cont ID  
Sent By mwennerg Date 2006-09-07 Time 14:49 Rev Time 0.00
Received By mwennerg Date 2006-09-07 Time 14:49 Sent To  
Notes
2006-09-07 00:00:00***DENIED***
  
 1) PLEASE NOTE THAT TWO DIFFERENT
 ADDRESSES ARE SHOWN ON PERMIT
 APPLICATION AND PLANS. PLEASE CORRELATE
 AND MAKE CORRECTIONS.
  
 2) ADDRESS IS REQUIRED ON BUIDING AND
 SHALL BE MINIMUM OF 6" IN HEIGHT AND
 CONTRASTING TO THE BACKGROUND FOR
 COMMERCIAL BUILDINGS.
  
 3) EXIT SIGNS WILL BE REQUIRED. PLEASE
 SHOW ON PLANS.
  
 4) 2A-10B,C RATED FIRE EXTINGUISHERS ARE
 REQUIRED AND SHALL BE MOUNTED AT EACH
 LEVEL NOT TO EXCEED 75' TRAVEL DISTANCE
 REQUIREMENT.
  
 5) LIFE SAFETY SHALL COMPLY WITH NFPA
 101, 2003 EDITION.
  
 6) NOTES ON SITE PLAN REFERENCE SLEEPING
 ROOMS. PLEASE REMOVE INFORMATION THAT IS
 NOT PERTINENT TO THIS PROJECT AS IT
 APPLIES TO THE CHANGE OF OCCUPANCY.
  
 7) CONSRUCTION, ALTERATION AND
 DEMOLITION TO COMPLY WITH NFPA 241.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-09-07 Cont ID  
Sent By mwennerg Date 2006-09-07 Time 15:41 Rev Time 0.00
Received By mwennerg Date 2006-07-22 Time 14:52 Sent To  
Notes
2006-08-08 00:00:00TO "COMM" BD#35
2006-07-22 00:00:00WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-08-25 Cont ID  
Sent By tgordon Date 2006-08-25 Time 13:46 Rev Time 0.30
Received By tgordon Date 2006-08-25 Time 13:46 Sent To  
Notes
2006-08-25 00:00:00*** DENIED ***
 1) NO MECHANICAL PLANS WERE SUBMITTED,
 PLEASE SUBMIT MECHANICAL PLANS SHOWING
 EXISTING AND NEW A/C SYSTEMS, DUCT WORK,
 BATHROOM VENTILATION, AND OUTSIDE AIR
 CALCULATIONS, FOR PLAN REVIEW.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-08-21 Cont ID  
Sent By kstevens Date 2006-08-21 Time 07:04 Rev Time 0.00
Received By kstevens Date 2006-08-21 Time 07:04 Sent To  
Notes
2006-08-21 00:00:00DENIED
 REFERENCE: FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
 FBC-2004 CHAPTER 11
 FBC-2004 EXISTING BLDG.
 FLORIDA ADMINISTRATIVE CODE
 FLORIDA STATUTES
  
 1. REMODEL IS A CHANGE OF OCCUPANCY. AS
 SUCH ALL PROVISIONS SHALL BE COMPLIED
 WITH FOR THE NEW OCCUPANCY. SECTION
 810.1.
  
 2. PLANS SHALL BE DESIGNED BY A DESIGN
 PROFESSIONAL. FS481.229(C) AND SHALL BE
 SIGNED, SEALED, DATED AND HAVE A TITLE
 BLOCK WITH ALL REQUIRED INFORMATION. FAC
 61G1-23.004 & FS481.2055.
  
 3. PER TABLE 403.1 A DRINKING FOUNTAIN
 IS REQUIRED. PLEASE SHOW CONNECTION TO
 SANITARY RISER DIAGRAM AND THE WATER
 RISER DIAGRAM THAT REFLECTS THE FLOOR
 PLAN. SECTION 106.3.5.1.3. SHOW ALL PIPE
 SIZES, TRAPS, VENTS, ON SANT. AND ALL
 PIPE SIZES, VALVES, ETC. ON WATER. -
 SUBMIT A DETAIL FOR THE DRINKING
 FOUNTAIN SHOWING COMPLIANCE WITH 11-4.15
 AND ALL SUBSECTIONS AS WELL AS
 11-4..3(10)(A) PROVISIONS FOR THOSE WHO
 HAVE DIFFICULTY BENDING OR STOOPING.
  
 4. GENERAL PROJECT NOTES INDICATE AN
 EXISTING RESIDENCE. AS A RESIDENCE, A
 KITCHEN SINK IS REQUIRED. PLEASE
 INDICATE THE LOCATION OF THE SINK AS IT
 IS NOT SHOWN ON THE EXISTING FLOOR PLAN.
 IF THE SINK IS TO BE RETAINED, IT SHALL
 COMPLY WITH SECTION 11-4.24 AND ALL
 SUBSECTIONS. ALSO REQUIRED IN A
 RESIDENCE IS A WASH MACHINE HOOK UP FOR
 WATER AND SANIT. DWV. THIS IS NOT SHOWN
 ON THE EXISTING FLOOR PLAN. PLEASE
 SUBMIT A FLOOR PLAN THAT SHOWS THE
 EXISTING FLOOR PLAN WITH ALL FIXTURES,
 EXISTING BEDROOMS, EXISTING KITCHEN ETC.
 SECTION 106.1.1.
  
 5. IF TOILET ROOMS ARE PROVIDED, THEN
 EACH PUBLIC AND COMMON USE TOILET ROOM
 SHALL COMPLY WITH SECTION 11-4.22.
 SUBMIT A DETAIL SHOWING COMPLIANCE WITH
 SECTIONS 11-4.16, 11-4.19, & 11-4.22
 WITH ALL SUBSECTIONS.
  
 6. AN RPZV BACKFLOW IS REQUIRED ON THE
 WATER SERVICE TO THE BUILDING. SECTION
 608. INDICATE ON PLANS.
  
 7. THERMAL EXPANSION CONTROL IS REQUIRED
 PER SECTION 607.3.2.
  
 8. INDICATE THE SQUARE FOOTAGE OF THE
 FLOOR PLAN TO CHECK MINIMUM FACILITIES
 REQUIRED PER TABLES 1004.1.2 & 403.1.
  
 REVIEW BY KEN STEVENS
 (561) 805-6721
 FAX (561) 805-6731
 E-MAIL [email protected]

Review Stop Z ZONING
Rev No 1 Status F Date 2006-08-23 Cont ID  
Sent By mflis Date 2006-08-23 Time 09:38 Rev Time 0.00
Received By mflis Date 2006-08-23 Time 09:38 Sent To  
Notes
2006-08-23 00:00:001) PLEASE SUBMIT COMPLETE SURVEY AND
 SITE PLAN INDICATING PARKING AND DRIVE
 DIMENSIONS. IT IS UNCLEAR AT THIS POINT
 HOW (AND IF) THE PARKING CONFIGURATION
 WILL WORK, INCLUDING NECESSARY TURNING
 RADII ETC.
  
 2) ADA PARKING LOADING/UNLOADING AREA
 ADJACENT TO SPACE SHOULD BE INDICATED,
 ALONG WITH ACCESSIBLE PATH TO BUILDING.
  
 3) PLEASE INDICATE EXISTING AND PROPOSED
 CONDITIONS ON SITE PLAN AND/OR SURVEY,
 INCLUDING ANY LANDSCAPING THAT MAY NEED
 TREE REMOVAL PERMITTING.
  
 4) PLEASE PROVIDE TYPICAL CITY PARKING
 DETAILS, INCLUDING DOUBLE STRIPING AND
 ADA PARKING DETAILS.
  
 REVIEWED BY MATTHEW FLIS, URBAN DESIGN