Plan Review Details - Permit 06070579
Plan Review Stops For Permit 06070579 |
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-08-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-08-01 |
Time |
10:13 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-08-01 |
Time |
10:13 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-07-16 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-07-16 |
Time |
17:09 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-07-16 |
Time |
16:59 |
Sent To |
PC |
|
Notes |
2006-07-16 00:00:00 | ** UNSAT ** | | | | 1) NOTE: PLEASE SPECIFY EXISTING | | OCCUPANCY. PLEASE STATE IF THE EXISTING | | OCCUPANCY IS CHANGING OR EXISTING TO | | REMAIN AND STATE THAT OCCUPANCY. | | FBC 105.1 ADMIN SECT. | | | | | | 2) NOTE: PLEASE PROVIDE AIC RATINS FOR | | NEW SERVICE MAINS/EEQUIPMENT PER 110.9 | | FBC 106.1.2 ADMIN SECT. | | | | 3) NOTE: PLEASE PROVIDE LOCATION OF NEW | | PANELS BEING INSTALLED. | | NEED TO VERIFY 110.26,240.24,408.7 ETC. | | | | 4) NOTE: PLEASE PROIDE A SIGNED CONTRACT | | FOR SCOPE OF WORK BEING DONE AS VALUE | | SEEMS LOW. | | FBC 108.3. | | | | 5) NOTE: PLEASE SEE FBC 106.1.2 AS THE | | PLANS ARE REQUIRED TO CONTAIN THE | | CLEARLY PRINTED NAME AND SIGNATURE OF | | THE PERSON RESPONSIBLE FOR PLANS/DESIGN. | | | | 6) NOTE: PLEASE SEE THAT ALL CONTINUOUS | | LOADS ARE TO BE SHOWN AT 125%, | | 215.3,230.42 ALONG WITH LARGEST MOTOR | | LOADS. | | | | 7) NOTE: PLEASE SEE 424.3B FOR MIN OCP | | AND AWG FOR 10KW A/C UNITS. | | (60A MIN). | | 240.4,310.16 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-07-31 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-31 |
Time |
13:11 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-31 |
Time |
13:11 |
Sent To |
E |
|
Notes |
2006-07-31 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2006-07-16 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-13 |
Time |
16:32 |
Sent To |
|
|
Notes |
2006-07-13 00:00:00 | TO "E" BOX |
|
|
|