Plan Review Stops For Permit 06070539 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2006-09-26 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-09-26 |
Time |
10:13 |
Rev Time |
0.33 |
Received By |
alange |
Date |
2006-09-26 |
Time |
10:13 |
Sent To |
|
|
Notes |
2006-09-26 00:00:00 | ELEVATION CERTIFICATE RECEIVED |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2006-07-26 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-07-26 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-07-26 |
Time |
16:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2006-09-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-09-17 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-09-17 |
Time |
11:30 |
Sent To |
B |
|
Notes |
2006-09-17 00:00:00 | ELEVATION CERTIFICATE OK WITH | | ELECTRICAL, AS THIS IS ALSO NEEDS A | | BUILDING REVIEW, SENT TO BUILDING | | REVIEWER FOR FINAL VERIFICATION AND | | STAMPING. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-08-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-08-17 |
Time |
07:43 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-08-17 |
Time |
07:20 |
Sent To |
PC |
|
Notes |
2006-08-17 00:00:00 | ELEV CERTIFICATE REQUIRED BEFORE FINAL. | | MUST BE OF SLAB ELEVATION, MUST ALSO | | CONTAIN THE ORIGINAL SIGNATURE FROM THE | | PERSON SEALING THE ELEV CERTIFICATE. | | FS 472.025, |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-08-07 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-08-07 |
Time |
20:20 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-08-07 |
Time |
20:15 |
Sent To |
PC |
|
Notes |
2006-08-07 00:00:00 | ***** UNSAT2ND REVIEW ***** | | | | PLEASE SEE SOME NOTES FROM PREVIOUS | | REVIEW STILL NEED TO NE VERIFIED ETC. | | | | 1) NOTE: NO, PLEASE SEE SPECS UBMITTED | | DO NOT SEEM TO CONTAIN THE DISCONNECITNG | | MEANS AS REQUIRED. IF THIS UNIT IS ONE | | OF THE NEW ONES WHICH CONTAINS A BRKR | | FOR NORMAL SIDE AND AND ADDTIONAL BRKR | | FOR EM/GEN SIDE, PLEASE BE SURE SPECS | | CLEARLY SHOW THIS. | | PLEASE KNOW, MANY OF GENERAC'S ONLY | | DISCONNECT POWER FROM THE NORMAL SIDE. | | THE TOGGLE SWITCH LOCATED IN SOME DO NOT | | MEET CODE. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE CLARIFY THE USE OF A SE | | RATED ATS. PLEASE SEE THE EXISTING MAIN | | FOR HOUSE IS STILL THE SERVICE MAIN. | | PLEASE SEE THAT THE ATS AS SPECIFIED | | DOES NOT DICONNECT POWER FROM GEN OR | | FEEDERS COMING FROM THE GEN AS REQUIRED | | PER 225.31-225.39. | | | | 2) NOTE:NO, PLEASE SEE I COULD NOT | | LOCATE THE MIN CLEARENCE REQUIRED FOR | | THIS GEN IN THE SPECS. PLEASE KNOW, THIS | | OFFICE HAS OBTAINED LTR FROMGENERAC | | WHICH REQUIRES A MIN OF 5' FOR THIS TYOE | | OF GEN. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE PROVIDE ALL THE SETBACKS | | AND DISTANCES AROUND GENERATOR. | | PLEASE SEE THAT THE SPECS PROVIDE | | INFORMATION ON MIN CLEARENCES. | | 110.3, 90.7 | | | | 3) NOTE: OK. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-07-21 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-07-21 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-07-21 |
Time |
08:15 |
Sent To |
M |
|
Notes |
2006-07-21 00:00:00 | ***** UNSAT ***** | | | | 1) NOTE: PLEASE CLARIFY THE USE OF A SE | | RATED ATS. PLEASE SEE THE EXISTING MAIN | | FOR HOUSE IS STILL THE SERVICE MAIN. | | PLEASE SEE THAT THE ATS AS SPECIFIED | | DOES NOT DICONNECT POWER FROM GEN OR | | FEEDERS COMING FROM THE GEN AS REQUIRED | | PER 225.31-225.39. | | | | 2) NOTE: PLEASE PROVIDE ALL THE SETBACKS | | AND DISTANCES AROUND GENERATOR. | | PLEASE SEE THAT THE SPECS PROVIDE | | INFORMATION ON MIN CLEARENCES. | | 110.3, 90.7 | | | | 3) NOTE: PLEASE KNOW, LOCATION OF JOB IS | | IN A FLOOD ZONE AND NEEDS TO SPECIFY THE | | MIN HEIGHT OF THE SLAB 6" ABOVE BFE BASE | | FLOOD ELEVATION. | | PLEASE ALSO KNOW, A "FLOOD ELEVATION | | CERTIFICATE" WILL ALSO BE REQUIRED | | BEFORE FINAL. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2006-07-26 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-07-26 |
Time |
15:16 |
Rev Time |
0.15 |
Received By |
mperson |
Date |
2006-07-26 |
Time |
15:16 |
Sent To |
B |
|
Notes |
2006-07-26 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | BEFORE FINAL GEN/RES INSPECTION. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-09-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-09 |
Time |
19:04 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-09 |
Time |
19:04 |
Sent To |
E |
|
Notes |
2006-09-09 00:00:00 | TO "DPALMER" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-08-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-15 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-15 |
Time |
13:58 |
Sent To |
E |
|
Notes |
2006-08-15 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-08-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-03 |
Time |
11:55 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-03 |
Time |
11:54 |
Sent To |
E |
|
Notes |
2006-08-03 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-07-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-18 |
Time |
11:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-18 |
Time |
11:38 |
Sent To |
E |
|
Notes |
2006-07-18 00:00:00 | TO "GEN-RES" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-07-26 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-07-26 |
Time |
16:30 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-07-12 |
Time |
16:52 |
Sent To |
|
|
Notes |
2006-07-12 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
N |
Date |
2006-08-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-08-17 |
Time |
07:46 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-08-17 |
Time |
07:47 |
Sent To |
|
|
Notes |
2006-08-17 00:00:00 | NAT GAS GEN, HAS BEEN MOVED PER | | MANUFACTURES MIN CLEARENCE REQUIREMENTS. | | ALSO 10FT FROM ANY OPENINGS INTO | | DWELLING. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-07-21 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-07-21 |
Time |
11:07 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2006-07-21 |
Time |
11:07 |
Sent To |
P |
|
Notes |
2006-07-21 00:00:00 | *** DENIED *** | | 1) SEE ELECTRICAL REVIEW, PLEASE | | CORRECT. | | 2) PER 2004 FBC, FUEL GAS - POWERED | | EQUIPMENT - PERMANENTLY INSTALLED | | EQUIPMENT POWERED BY INTERNAL COMBUSTION | | ENGINES SHALL BE INSTALLED IN ACCORDANCE | | WITH MANUFACTURE'S INSTALLATION | | INSTRUCTIONS AND NFPA 37. | | NFPA 37 INSTALLATION & USE OF STATIONARY | | COMBUSTION ENGINES & GAS TURBINES: | | 4.1.4ENGINES (GENERATORS) LOCATED | | OUTDOORS SHALL BE MINIMUM OF 5 FT FROM | | OPENINGS IN WALLS & AT LEAST 5 FT FROM | | STRUCTURES HAVING COMBUSTIBLE WALLS.A | | MINIMUM CLEARANCE IS NOT REQUIRED WHEN | | (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | RESISTANCE RATING OF 1 HOUR OR (2) THE | | WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF | | NON-COMBUSTIBLE MATERIALS, AND IT HAS | | BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | MATERIALS OUTSIDE THE ENCLOSURE. | | INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS | | SHOULD NOT TERMINATE UNDER STRUCTURES OR | | WHERE THE EXHAUST MIGHT BE DRAWN INTO | | THE VENTILATION INTAKES. | | 2004 FMC 804.3.5 #3, WHERE THE | | TERMINATION IS LOCATED BELOW AN ADJACENT | | ROOF STRUCTURE, THE TERMINATION POINT | | SHALL BE LOCATED AT LEAST 3 FT FROM THE | | ROOF STRUCTURE. | | PLEASE NOTE, WHILE ZONING ALLOWS | | MECHANICAL EQUIPMENT TO ENCROACH 4 FT | | INTO THE REQUIRED SETBACK, GENERATORS | | SHALL MAINTAIN THE REQUIRED ABOVE | | MENTIONED CLEARANCES TO THE ADJACENT | | PROPERTY STRUCTURES, I.E. FENCE, | | BUILDING, WINDOWS, DOORS, OR OPENINGS. | | PROVIDE MANUFACTURE'S INSTALLATION | | INSTRUCTIONS AT THE JOBSITE FOR THE | | FIELD INSPECTOR. | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2006-07-16 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-07-16 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-07-16 |
Time |
13:48 |
Sent To |
I |
|
Notes |
2006-07-16 00:00:00 | NOTE: | | THE PROPOSED GENERATOR SHALL NOT BE | | CLOSER THAN 6FT FROM SIDE PROPERTY LINE. |
|
|