Plan Review Details - Permit 06070456
Plan Review Stops For Permit 06070456
Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-08-15 Cont ID  
Sent By adarroug Date 2006-08-15 Time 08:49 Rev Time 0.00
Received By adarroug Date 2006-08-15 Time 08:49 Sent To P
Notes
2006-08-15 00:00:00TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-08-15 Cont ID  
Sent By adarroug Date 2006-07-17 Time 08:49 Rev Time 0.00
Received By adarroug Date 2006-07-11 Time 15:15 Sent To  
Notes
2006-07-11 00:00:00TO "P" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-08-21 Cont ID  
Sent By mperson Date 2006-08-21 Time 08:53 Rev Time 0.33
Received By mperson Date 2006-08-21 Time 08:53 Sent To PC
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-07-17 Cont ID  
Sent By mperson Date 2006-07-17 Time 09:45 Rev Time 0.45
Received By mperson Date 2006-07-17 Time 09:45 Sent To  
Notes
2006-07-17 00:00:00******DENIED******
 REFERENCE FBC-2004 PLUMBING
 FBC-2004 CHAPTER 1
  
 THE FOLLOWING INFORMATION IS REQUIRED
 FOR PLUMBING PLAN REVIEW:
  
 1. THE ISOMETRIC SANITARY RISER DIAGRAM
 DOES NOT REFLECT THE MASTER PERMIT
 #06031290 FLOOR PLAN PLEASE SEE ATTACHED
 ISOMETRIC IN RED INK FOR REFERENCE FOR
 RESUBMITTAL
 2. FBC-2004 CHAPTER 1,SECTION 106.3.4.2:
 THE PERSON RESPONSIBLE FOR THE DESIGN OF
 THE DRAWING SHALL CLEARLY PRINT AND SIGN
 NAME, AND ALSO DATE DRAWING. PLEASE DO
 THIS PRIOR TO RESUBMITTING.
 3. PLEASE INDICATE ON THE ISOMETRIC SAN-
 ITARY RISER DIAGRAM EXACTLY WHAT IS
 EXISTING TO REMAIN AND WHAT IS REPAIRED
 NEW. (NOTE: PLEASE INDICATE IF
 UNDERGROUND FOR WASHING MACHINE IS
 EXISTING OR NEW BECAUSE OF CODE CHANGES
 SEE ATTACHED ISO. PLMG. RISER DIAGRAM IN
 RED INK FOR REFERENCE FOR RESUBMITTAL)
 4. PER FBC-2004, CHAPTER 1, SECTION
 106.1 SUBMITTAL DOCUMENTS: THE ARCHITECT
 ON RECORD SHALL,
 A) IF THE DESIGN PROFESSIONAL IS AN
 ARCHITECT OR ENGINEER LEGALLY REGISTERED
 UNDER THE LAWS OF THIS STATE REGULATING
 THE PRACTICE OF ARCHITECTURE AS PROVIDED
 FOR IN CHAPTER 481, FLORIDA STATUTES,
 PART 1, OR ENGINEERING AS PROVIDED FOR
 IN CHAPTER 471, FLORIDA STATUTES, THEN
 HE OR SHE SHALL AFFIX HIS OR HER SEAL,
 SIGNATURE AND DATE TO SAID
 DRAWINGS,(ISOMETRIC SANITARY RISER
 DIAGRAMS) SPECIFICATIONS AND
 ACCOMPANYING DATA, AS REQUIRED BY
 FLORIDA STATUTES.
  
 **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN
 RESUBMITTING, PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED,AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  
  