Plan Review Stops For Permit 06070197 |
Review Stop |
AD |
ADDRESSING |
Rev No |
3 |
Status |
P |
Date |
2007-01-02 |
|
|
Cont ID |
|
Sent By |
swurafti |
Date |
2007-01-02 |
Time |
12:07 |
Rev Time |
0.00 |
Received By |
swurafti |
Date |
2007-01-02 |
Time |
12:07 |
Sent To |
|
|
Notes |
2007-01-02 12:11:06 | GAVE ADDRESS A PCN # AFTER PROOF OF UNITY TITLE FOR | | BOTH BAYS PER LILI & RBROWN |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
2 |
Status |
F |
Date |
2006-12-12 |
|
|
Cont ID |
|
Sent By |
lursu |
Date |
2006-12-12 |
Time |
09:07 |
Rev Time |
0.00 |
Received By |
lursu |
Date |
2006-12-12 |
Time |
09:07 |
Sent To |
|
|
Notes |
2006-12-12 09:07:30 | UNITY OF TITLE IS REQUIRED IF THE BAYS ARE COMBINED. | | | | LACRAMIOARA URSU | | MIS - GIS SUPPORT SPECIALIST | | E-MAIL:[email protected] |
|
|
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2006-07-19 |
|
|
Cont ID |
|
Sent By |
lursu |
Date |
2006-07-19 |
Time |
11:43 |
Rev Time |
0.00 |
Received By |
lursu |
Date |
2006-07-19 |
Time |
11:43 |
Sent To |
|
|
Notes |
2006-07-19 00:00:00 | CREATE TEMPORARY PCN FOR THIS TWO BAYS | | 231 & 232 UNDER THE ADDRESS OF 5403 N | | HAVERHILL RD.PCN = | | TEMP7442430208A31.PERMIT MUST BE | | ATTACHED TO THIS PCN. | 2006-07-18 00:00:00 | NEEDS BAY #'S EXT? |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2006-12-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-12-13 |
Time |
16:43 |
Rev Time |
1.33 |
Received By |
jwitmer |
Date |
2006-12-13 |
Time |
16:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2006-11-02 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-11-02 |
Time |
12:24 |
Rev Time |
2.22 |
Received By |
jwitmer |
Date |
2006-11-02 |
Time |
12:24 |
Sent To |
PC |
|
Notes |
2006-11-02 12:35:41 | BUILDING PLAN REVIEW | | PERMIT: 06070197 | | ADD: 5403 N HAVERHILL RD | | SUITE 31& 32 | | CONT:PRIME MECHANICAL SERVICES | | TEL: (954)444-6823 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 3RD REVIEW | | ACTION: DENIED | | | | --- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | PLEASE TAKE TIME TO READ! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & "REMOVE ALL VOID SHEETS" & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 1)THIRDREQUEST, THIS REQUEST WASN'T | | EVEN LISTED ON THE RESPONSE SHEET, | | ADDITIONAL INFORMATION REQUIRED | | 106.1.2*THERE IS NO INFORMATION AS HOW | | THE FREEZERS CEILING WILL BE FRAMED OR | | HOW IT WILL STAY IN PLACE? WILL IT BE | | ABLE TO TAKE ANY LOADING? | | | | 2) 2ND REQUEST! THIS PROJECT IS A | | CONDOMINIUM REQUIRING A UNITY OF TITLE | | FOR THE 2 UNITS. SEE PLANNING & ZONING | | FOR THE REQUIRED PAPERWORK AND | | APPROVALS. TABLE 601 ISSUES.) THE PROPOSED BUILDING | | STRUCTURE | | TRANSGRESSES LEGAL BOUNDARY LINES | | BETWEEN THE LOTS WHICH COMBINE TO FORM | | 'THE SITE'.A 'UNITY OF TITLE' SHALL BE | | RECORDED AT THE COUNTY COURTHOUSE. | | SUBMIT A COPY OF THE RECORDED 'UNITY OF | | OF TITLE' DOCUMENT SO THAT FBC TABLE 601 | | BOUNDARY LINE REQUIREMENTS MAY BE DEEMED | | NOT APPLICABLE. | | | | | | 3)!!!!!!!!!FEES DUE!!!!!!!!!!!!!!!! | | THIRDREQUEST, REVIEWS ARE NOT TO TAKE | | PLACE WHEN FEES ARE DUE!!!!!!!! FEES DUE | | TO ADDITION OF FIRE REVIEW | | 10% OF PERMIT FEE. A "HOLD" IS PUT | | ON THIS PERMIT THAT THE PERMIT FEE IS TO BE | | PAYED IN FULLBEFORE THE PERMIT MAY | | BE RESUBMITTED. A 10% SURCHARGE WILL ALSO | | BE ASSESSED AND PAID BEFORE THE | | THIRD REVIEW MAY COMMENCE. | | FBC 108.1 PRESCRIBED FEES* 108.2*. | | | | 4) EVALUATION IS LOW, IF THE CORRECT | | CONTRACT VALUE AND ASSOCIATED FEES ARE | | NOT UPDATED, FEES PAID BEFORE THE NEXT | | REVIEW WE WILL ASSESS THE CORRECT FEES | | AND FEES USING MARSHALL & SWIFT TO | | CALCULATE THE VALUES. | | 108.1* ADMINISTRATIVE CODE. | | | | 5)A NEW NOTICE OF COMMENCEMENT WILL BE REQUIRED, | | THE RECORDED NOTICE OF COMMENCEMENT DOESN'T INDICATE | | THE PRIME MECHANICAL CONTRACTOR. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | | | | | | | | | | | | | | | | | | | | | | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-09-15 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-09-15 |
Time |
07:30 |
Rev Time |
0.55 |
Received By |
jwitmer |
Date |
2006-09-15 |
Time |
07:30 |
Sent To |
|
|
Notes |
2006-09-15 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 06070197 | | ADD: 5403 N HAVERHILL RD | | SUITE 31& 32 | | CONT:PRIME MECHANICAL SERVICES | | TEL: (954)444-6823 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 2ND REVIEW | | ACTION: DENIED | | | | 1)SECOND REQUEST, THIS REQUEST WASN'T | | EVEN LISTED ON THE RESPONSE SHEET, | | ADDITIONAL INFORMATION REQUIRED | | 106.1.2*THERE IS NO INFORMATION AS HOW | | THE FREEZERS CEILING WILL BE FRAMED OR | | HOW IT WILL STAY IN PLACE? WILL IT BE | | ABLE TO TAKE ANY LOADING? | | | | 2) NEW COMMENT! THIS PROJECT IS A | | CONDOMINIUM REQUIRING A UNITY OF TITLE | | FOR THE 2 UNITS. SEE PLANNING & ZONING | | FOR THE REQUIRED PAPERWORK AND | | APPROVALS. | | | | | | 3)!!!!!!!!!FEES DUE!!!!!!!!!!!!!!!! | | SECOND REQUEST, REVIEWS ARE NOT TO TAKE | | PLACE WHEN FEES ARE DUE!!!!!!!! FEES DUE | | TO ADDITION OF FIRE REVIEW | | 10% OF PERMIT FEE. | | | | 4) EVALUATION IS LOW, IF THE CORRECT | | CONTRACT VALUE AND ASSOCIATED FEES ARE | | NOT UPDATED, FEES PAID BEFORE THE NEXT | | REVIEW WE WILL ASSESS THE CORRECT FEES | | AND FEES USING MARSHALL & SWIFT TO | | CALCULATE THE VALUES. | | 108.1* ADMINISTRATIVE CODE. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-08-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-08-01 |
Time |
12:02 |
Rev Time |
1.55 |
Received By |
jwitmer |
Date |
2006-08-01 |
Time |
12:02 |
Sent To |
PC |
|
Notes |
2006-08-01 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 06070197 | | ADD: 5403 N HAVERHILL RD UNIT 31/32 | | CONT: PRIME MECHANICAL SERVICES | | TEL: (954)444-6823 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1) PLEASE PROVIDE THE LISTING REPORT | | WHICH PROVIDES THE DATA MEETING THE | | REQUIREMENTS OF 2603.4.1.2 COOLER AND | | FREEZER WALLS. | | | | 2) PLEASE PROVIDE THE FIRE SPRINKLER | | PLANS AS REQUIRED BY 2603.4.1.2(4)BE | | PROTECTED BY AN AUTOMATIC SPRINKLER | | SYSTEM. WHERE THE COOLER OR FREEZER IS | | WITHIN A BUILDING, BOTH THE COOLER OR | | FREEZER AND THAT PART OF THE BUILDING IN | | WHICH IT IS LOCATED SHALL BE | | SPRINKLERED. PROVIDE THE DETAILS HOW THE | | FIRE SPRINKLER HEADS WILL TRANSITION | | INTO THE FREEZER AND WALK IN COOLER. | | | | 3) ADDITIONAL INFORMATION REQUIRED | | 106.1.2*THERE IS NO INFORMATION AS HOW | | THE FREEZERS CEILING WILL BE FRAMED OR | | HOW IT WILL STAY IN PLACE? WILL IT BE | | ABLE TO TAKE ANY LOADING? | | | | 4) FEES DUE TO ADDITION OF FIRE REVIEW | | 10% OF PERMIT FEE. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2007-06-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-06-28 |
Time |
08:49 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-06-27 |
Time |
20:12 |
Sent To |
|
|
Notes |
2007-06-28 08:51:45 | | | 2007-06-28 08:51:45 | | OK, STAMPED, LETTERS ON FILE. | 2007-06-27 20:17:24 | 2007-06-27 20:17:24 | | ON HOLD IN ELECTRICAL. CALLED KIM LIDDELL AND LEFT | | MESSAGE FOR LETTERS FROM THE DESIGNERS OF RECORD TAKING | | OVER PROJECT AND OWNER RELEASING PREVIOUS DESIGN TEAM. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2007-04-04 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-04-04 |
Time |
13:38 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-04-04 |
Time |
13:38 |
Sent To |
PC |
|
Notes |
2007-04-04 13:47:59 | ** UNSAT ** | | | | 1) NOTE: PLEASE SEE THAT ANY CHANGES TO LIGHTING ON | | PLANS MUST BE DONE BY THE ENGINEER OF RECORD. | | NO HAND-DRAWN CHANGES ARE PERMITTED. | | FS 471.025 | | | | 2) NOTE: PLEASE SEE MISSING INFORMATION ON TITLE BLOCK | | FOR THE ARCHITECTURAL FIRM AND PRINTED NAME AND LICENSE | | NUMBER FOR THE NEW ARCHITECT OF RECORD. | | PLEASE SEE FAC 61G1-16.004 AND FS 481.219. | | THIS COMMENT IS NOT FOR THE ENGINEERING FIRM. | | | | 3) NOTE:PLEASE BE SURE THAT COMPLETE PLANS REVISING | | THE COMPLETED SETS OFPLANS FROM THE NEW DESIGN TEAM | | WILL BE REQUIRED TO BE SUBMITTED. MAY NOT HAVE SOME | | SHEETS FROM ONE DESIGN TEAM AND ONE SHEET OR OTHER | | SCOPE FROM ANOTHER DEISGN TEAM. | | FS 481/471 | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2006-12-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-12-09 |
Time |
17:12 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-12-09 |
Time |
17:07 |
Sent To |
I |
|
Notes |
2006-12-09 17:13:17 | ELEC OK, STAMPED REVISEED SHEET. | | PLANS ROUTED BACK TO INCOMING. | 2006-12-09 17:08:30 | PLANS REMOVED FROM INCOMING, PLANS WILL BE ROUTED BACK | | TO INCOMING WAITING FOR THE COMM BOB BOARD. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2006-10-27 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-10-27 |
Time |
20:58 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-10-27 |
Time |
20:48 |
Sent To |
|
|
Notes |
2006-10-27 20:58:47 | *** UNSAT **** | | | | | | 1) NOTE: PLEASE SEE ATTACHEDAND LOOSE SHEETS ATTACHED | | TO PLANS WHICH ARE DONE BY AN ENGINEER OR ARCHITECT IS | | NOTACCEPTABLE. | | PLEASE SEE SHEET E-3.01 HAS NOW BEEN VOIDED. | | PLEASE SEE PREVIOUS NOTES, OCCUPANCY SENSOR | | TYPE/AUTOMATIC DEVICES REQUIRED. | | | | | | ** PLEASE BE SURE THE VOIDED SHEETS ARE COMPLETELY | | REMOVED AND NEW SHEETS ARE INSERTED . DO NOT PLACE | | SHEETS IN SETS DONE BY CONTRACTOR AS THIS IS NOT UNDER | | THEIR SCOPE PERMITTED. | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-09-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-09-08 |
Time |
18:32 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-09-08 |
Time |
18:15 |
Sent To |
|
|
Notes |
2006-09-08 00:00:00 | *** NOTES REDLINED ON PLANS *** | | | | 1) NOTE: PLEASE SEE NFPA-101 7.9.2.2, IF | | AREA IN COOLER IS BEING LEFT IN TOTAL | | DARKNESS UPON THE TURNING OFF OF THE | | SWITHCES AS SHOWN, AN OCCUPANCY SENSOR | | OF SOME TYPE WILL BE REQUIRD INSIDE | | COOLER UNIT TO OVER RIDE LTS. THIS WILL | | ALLEAVIATE LEAVING AN OCCUPANT IN TOTAL | | DARKNESS FOR EGRESS IN THE EVENT THE | | SWITCHES BECOME ACCIDENTLY SWITCHED OFF. | | ** THE SIZE AND TRAVEL DISTANCE IN THIS | | COOLER IS SUBSTANTIAL AND WILL ALSO BE | | REQUIRED BY THE FIRE MARSHAL'S OFFICE. | | | | IF THERE ARE ANY QUESIONS, PLEASE DO NOT | | HESITATE IN CONTACTING THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] | | VALUE FOR SCOPE PF WORK IS STILL IN NEED | | OF ADJUSTMENT TO INCLUDE ALL | | ELECTRICAL,MECHANICAL EQUIPMENT AND NEW | | COOLER. | | THE ELECTRICAL STATUS SHALL REMAIN IN | | "F" STATUES UNTIL ADJUSTMENT IS MADE. IF | | ONE IS NOT ADJUSTED BY CONTRACTOR, ONE | | WILL BE ADJUSTED PER MARSHAL'S & SWIFT | | GUIDES AS ADOPTED BY THE FBC 108.3 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-07-18 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-07-18 |
Time |
20:14 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-07-18 |
Time |
19:13 |
Sent To |
|
|
Notes |
2006-07-18 00:00:00 | ******** UNSAT ********* | | | | 1) NOTE: PLEASE SEE THE LIGHTING LAYOUT | | WHICH WAS PROVIDED SEPARATELY NEEDS TO | | CONTAIN CIRCUITING, CONTROLS AND | | CORRELATE WITH THE SUBMITTED PANEL | | SCHEDULE ON PLANS. IN FACT THE | | ELECTRICLA LAYOUT SHOWN FOR COOLER | | SHOULD BE PROVIDED BY THE DESIGN | | PROFESSIONAL WHICH HAD DRAWN THE PLANS | | FOR THE INSTALLATION OF COOLER AND ALL | | OTHER ELECTRICAL WORK IN THIS SCOPE PF | | WORK FOR THIS PERMIT FOR SPACE. | | PLEASE KNOW, AS SCOPE OF WORK IS | | PERMITTED AND DONE UNDER THE SAME | | PERMIT. ONE DESIGN PROFESSIONAL SHOULD | | BE RESPOSIBLE FOR DESIGN AND | | CONNECTIONS, ETC ARE COMBINED. | | 106.1.2 ADMIN SECT. PLEASE BE SURE TO | | SEE 700.12E FOR CIRCUITIGN OF EM/EXT LTS | | TO THE LOCAL LIGHTING BRANCH CIRCUIT IN | | ANY ONE AREA. PLEASE KNOW, FAILURE OF | | ONE OCP, CIRCUIT SHOULD NOT LEAVE IN ONE | | AREA IN TOTAL DARKNESS. | | LS 101 7.8, 7.9 | | | | 2) NOTE: PLEASE SEE RESPONSE LTR FROM | | ARCHITECT'S OFFICE MENTIONS THE 2000 LS | | CODE. PLEASE KNOW, WE ARE CURRENTLY | | UNDER THE 2003 101. | | | | 3) NOTE: PLEASE SEE THAT THE SPECS ON EM | | LTS ARE OK, HOWEVERTHERE IS A QUESTION | | ON THE EM/EXT COMBO UNITWHERE THE | | LISTING FOR THIS FIXTURE PERMITS THE | | INSTALLATION IN THE COOLER/DAMP/POSSIBLE | | WET LOCATION.? COULD NOT LOCATE ANY | | INFORMATION ON SPECS SUBMITTED WHICH | | LENDS TO THIS? | | PLEASE ALSO SEE THE UNIT IS SHOWN AS A | | COMBO UNIT WHICH IS FINE, HOWEVER PLANS | | SHOULD INDICATE THIS. | | 110.3, FBC 106.1.2 ADMIN SECT. | | | | 4) NOTE: PLEASE KNOW, IF ALL OTHER | | ELECTRICAL MECHANICAL WORK IS INLCUDED | | IN THE PERMIT/SCOPE, THEN PLEASE KNOW, | | VALUATION FOR PERMIT SHALL INCLUDE ALL | | LABOR AND MATERIALS WHETHER OR NOT ANY | | OF THE EQUIPMENT IS OWNER SUPPLIED. | | FBC 108.3 | | | | THE EXTENSIVE RESPONSE LTR IS | | APPRECIATED FOR CLARIFICATION OF OTHER | | ITEMS. | | | | IF THERE ARE ANY QUESTIONS ON NOTE #1, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS REVIEWER. | | | | ** PLEASE BE SURE TO SEE ANY POSSIBLE | | COMMENTS FROM OTHER TRADES WHICH MAY | | AFFECT THE ELECTRICAL PLANS, DESIGN ETC. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
5 |
Status |
P |
Date |
2007-06-28 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2007-06-28 |
Time |
10:15 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2007-06-28 |
Time |
10:15 |
Sent To |
|
|
Notes |
2007-06-28 10:16:23 | REVISION DATED 5/22/07 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
4 |
Status |
N |
Date |
2006-12-22 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-12-22 |
Time |
12:55 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-12-22 |
Time |
12:55 |
Sent To |
|
|
Notes |
2006-12-22 12:56:04 | PLANS APPROVED AND STAMPED ON 9/19/06 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2006-10-30 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2006-10-30 |
Time |
09:33 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2006-10-30 |
Time |
09:33 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2006-09-19 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-09-19 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-09-19 |
Time |
09:28 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2006-07-19 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-07-19 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-07-19 |
Time |
15:05 |
Sent To |
|
|
Notes |
2006-07-19 00:00:00 | ***PROVISO*** | | | | 1) SEPARATE SHOP DRAWINGS AND PERMIT | | REQUIRED FOR FIRE SPRINKLER REMODEL. | | | | 2) LIFE SAFETY SHALL COMPLY WITH NFPA | | 101, 2003 EDITION. | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-06-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-06-25 |
Time |
12:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-25 |
Time |
12:47 |
Sent To |
|
|
Notes |
2007-06-26 11:19:15 | TO "BOB"#2 | 2007-06-25 12:48:09 | WAITING FOR "BOB" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-03-30 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2007-03-30 |
Time |
17:32 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2007-03-30 |
Time |
17:32 |
Sent To |
E |
|
Notes |
2007-03-30 17:32:31 | TO DEWEY PALMER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-11-29 |
|
|
Cont ID |
|
Sent By |
spalmer |
Date |
2006-11-29 |
Time |
18:42 |
Rev Time |
0.00 |
Received By |
spalmer |
Date |
2006-11-29 |
Time |
18:42 |
Sent To |
|
|
Notes |
2006-12-12 17:38:35 | TO "BOB"#11 | 2006-11-29 18:42:23 | WAITING FOR "BOB" BOARD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-10-23 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-23 |
Time |
11:31 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-23 |
Time |
11:31 |
Sent To |
|
|
Notes |
2006-10-27 15:45:28 | TO "BOB"#18 | 2006-10-23 11:32:05 | WAITING FOR "BOB" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-09-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-06 |
Time |
16:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-06 |
Time |
16:34 |
Sent To |
|
|
Notes |
2006-09-08 00:00:00 | TO "BOB"#15 | 2006-09-06 00:00:00 | WAITING FOR "BOB" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-08-01 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-08-01 |
Time |
12:37 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2006-07-10 |
Time |
09:46 |
Sent To |
|
|
Notes |
2006-07-13 00:00:00 | TO "BOB"#8 | 2006-07-10 00:00:00 | WAITING FOR "BOB" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2007-06-29 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-06-29 |
Time |
11:38 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-06-29 |
Time |
11:38 |
Sent To |
|
|
Notes |
2007-06-29 11:39:26 | REVISION TO PLANS. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2006-09-11 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-09-11 |
Time |
15:34 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2006-09-11 |
Time |
15:34 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-07-14 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-07-14 |
Time |
14:33 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2006-07-14 |
Time |
14:33 |
Sent To |
|
|
Notes |
2006-07-14 00:00:00 | *** DENIED *** | | 1) NOTICE OF COMMENCEMENT MUST HAVE THE | | FOLLOWING INFORMATION ADDED TO IT, | | *LEGAL DESCRIPTION OF PROPERTY,AND | | GENERAL DESCRIPTION OF IMPROVEMENTS. | | THEN REFILE WITH PALM BEACH COUNTY. | | | | 2) SHOW ON MECHANICAL PLAN HOW CONDENSER | | UNITS ARE TO BE ANCHORED TO CONDENSER | | STANDS AND HOW MANY STRAPS PER COMDENSER | | UNIT. BE ADVISED TIE DOWN CABLES ARE NOT | | PERMITTED OVER THE TOP OF A CONDENSER | | UNIT. | | | | 3) PLEASE ESTIMATE AMOUNT OF CONDENSATE | | WATER TO ENTER DRY WELL AND SIZE DRY | | WELL ACCORDINGLY. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2007-07-02 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-07-02 |
Time |
11:04 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-07-02 |
Time |
11:04 |
Sent To |
|
|
Notes |
2007-07-02 11:05:12 | CONDENSATE DRAINAGE ONLY |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2007-01-02 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-01-02 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-01-02 |
Time |
14:55 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2006-09-23 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-09-23 |
Time |
07:32 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-09-23 |
Time |
07:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-07-18 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-07-18 |
Time |
09:37 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-07-18 |
Time |
09:32 |
Sent To |
|
|
Notes |
2006-07-18 00:00:00 | CONDENSATE PIPING TO BE INCLUDED ON | | MASTER BUILDING PERMIT PLANS. NO | | PLUMBING REVIEW AT THIS TIME. | | JOHN LEECH | | 805-6695 |
|
|