Plan Review Details - Permit 06070109
Plan Review Stops For Permit 06070109 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2007-09-04 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2007-09-04 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2007-09-04 |
Time |
13:15 |
Sent To |
|
|
Notes |
2007-09-04 13:17:59 | REVISION FOR STEEL COLUMNS AND DOOR PRODUCT APPROVALS |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
P |
Date |
2007-03-02 |
|
|
Cont ID |
|
Sent By |
lmartine |
Date |
2007-03-02 |
Time |
15:33 |
Rev Time |
0.00 |
Received By |
lmartine |
Date |
2007-03-02 |
Time |
15:33 |
Sent To |
|
|
Notes |
2007-03-02 15:34:37 | | | REVISION OK, SUBMIT PRODUCT APPROVAL FOR 10' DOORS. | | LM |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2006-11-07 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-11-07 |
Time |
13:59 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-11-07 |
Time |
13:59 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-09-27 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-09-27 |
Time |
10:20 |
Rev Time |
1.50 |
Received By |
alange |
Date |
2006-09-26 |
Time |
16:07 |
Sent To |
|
|
Notes |
2006-09-27 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | SHALL BE RECORDED AT PALM BEACH COUNTY | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | BLANK FORMS ARE AVAILABLE FROM THIS | | OFFICE. | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | 90 DAYS OF RECORDING. | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY. THE ACTUAL PERMIT | | SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 5.PGT 701 MISSING STATE PRODUCT | | APPROVAL. | | | | 7.THOSE PRODUCT APPROVALS WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL.WPB | | AMENDMENT TO FBC 106.3.3. | | | | 10.SHOW FIREPLACE CONSTRUCTION | | DETAILS. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | OLD PAGES FOR REFERENCE . A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET | | OR SPECIFICATION PAGE WHERE THE CHANGES | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | ART LANGE | | CONSTRUCTION SERVICES DEPARTMENT | | BUILDING PLANS EXAMINER | | 561-805-6672 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-07-17 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-07-17 |
Time |
09:18 |
Rev Time |
3.50 |
Received By |
alange |
Date |
2006-07-17 |
Time |
09:18 |
Sent To |
|
|
Notes |
2006-07-17 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | SHALL BE RECORDED AT PALM BEACH COUNTY | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | BLANK FORMS ARE AVAILABLE FROM THIS | | OFFICE. | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | 90 DAYS OF RECORDING. | | | | 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE | | ISSUED, IMPACT FEES MUST BE PAID TO PALM | | BEACH COUNTY. THE ACTUAL PERMIT | | SET OF PLANS MUST BE STAMPED BY THAT | | OFFICE, AND A COPY OF THE PAID RECEIPT | | ATTACHED TO THE PERMIT APPLICATION. | | PLEASE CALL (561)233-5025 FOR MORE | | INFORMATION. | | | | 4. SIGN OWNER/AGENT ON ENERGY CALCS PER | | 2004 FBC. | | | | 5.PRODUCT APPROVALS REQUIRED FOR | | LINTELS.PGT 701 MISSING STATE PRODUCT | | APPROVAL. | | | | 6.ALL PRODUCT APPROVALS SUBMITTED WITH | | QUALITY ASSURANCE SHALL HAVE THE | | FOLLOWING STATE APPROVAL ATTACHED. | | | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A STATE PRODUCT APPROVAL | | SHEETS THAT LISTS THE PRODUCT IDENTITY | | NUMBER FROM THE STATE. IF THE PRODUCT | | DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT | | AN APPLICATION FOR LOCAL PRODUCT | | APPROVAL OR SITE SPECIFIC FORM PER RULE | | 9B-72. SEE ATTACHMENT. | | WWW.FLORIDABUILDING.ORG | | | | 7.THOSE PRODUCT APPROVALS WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL.WPB | | AMENDMENT TO FBC 106.3.3. | | | | 8.R401.3 DRAINAGE. | | SURFACE DRAINAGE SHALL BE DIVERTED TO A | | STORM SEWER CONVEYANCE OR OTHER APPROVED | | POINT OF COLLECTION SO AS TO NOT CREATE | | A HAZARD. LOTS SHALL BE GRADED SO AS TO | | DRAIN SURFACE WATER AWAY FROM FOUNDATION | | WALLS. THE GRADE AWAY FROM FOUNDATION | | WALLS SHALL FALL A MINIMUM OF 6 INCHES | | WITHIN THE FIRST 10 FEET. | | | | 9.SHOW GUARD RAIL DETAILS COMPLYING | | WITH R-312.1 AND R-312.2. | | | | 10.SHOW FIRE PLACE CONSTRUCTION | | DETAILS. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | OLD PAGES FOR REFERENCE . A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET | | OR SPECIFICATION PAGE WHERE THE CHANGES | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | ART LANGE | | CONSTRUCTION SERVICES DEPARTMENT | | BUILDING PLANS EXAMINER | | 561-805-6672 | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
7 |
Status |
P |
Date |
2008-03-13 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-03-13 |
Time |
15:28 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-03-13 |
Time |
14:40 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
F |
Date |
2008-03-10 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2008-03-10 |
Time |
13:14 |
Rev Time |
0.00 |
Received By |
btrobaug |
Date |
2008-03-10 |
Time |
13:11 |
Sent To |
PC |
|
Notes |
2008-03-10 13:14:11 | | | | | THIS REVIEW WAS DONE UNDER THESE CURRENT CODE | | CYCLES: | | | | THE 2004 FLORIDA BUILDING CODE, 2007 REVISIONS, 2004 | | RESIDENTIAL BUILDING CODE, 2005 NEC, 2004 FBC AS | | AMENDED, CHAPTER 1.AND FOUND NONCOMPLIANT WITH THE | | FOLLOWING: | | | | 1} HAND DRAWN CHANGES TO THE PLAN ARE NOT ACCEPTABLE | | FOR RECORD RETENTION OR CLARITY IN THE FIELD. 106.1.3 | | FBC AS AMENDED.PLANS ARE REQUIRED TO BE DRAFTSMAN | | QUALITY | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | BILL TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | 561/805-6718 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2006-11-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-11-20 |
Time |
17:31 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-11-20 |
Time |
16:26 |
Sent To |
PC |
|
Notes |
2006-11-20 17:32:47 | ** | | | | ALL MAINS GROUPED AND NO MORE THAN 8FT OF UNPROTECTED | | CONDUCTORS INSIDE THE BUILDING. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2006-10-29 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-10-29 |
Time |
13:06 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-10-29 |
Time |
11:34 |
Sent To |
B |
|
Notes |
2006-10-29 13:06:08 | **** UNSAT 3RD REVIEW **** | | | | ** PLEASE SEE SOME COMMENTS FROM | | PREVIOUS REVIEW AND SOME NEW COMMENTS | | DUE TO CHANGES IN PLANS. | | COMMENTS BELOW ARE TAKEN DIRECTLY FROM | | PREVIOUS REVIEW AND THEN NEW COMMENTS | | ARE ADDED TO BOTTOM. | | | | 1) NOTE: OK. | | | | 2) NOTE: OK. | | | | 3) NOTE: OK. | | | | 4) NOTE: OK | | | | 5) NOTE: OK. | | | | 6) NOTE OK. | | | | 7) NOTE:NO, OK, PLEASE SEE NEW NOTES FOR A REVISED | | RISER WHICH HAS NOW CHANGED A THIRD TIME. | | | | ** PREVIOUS REVIEW NOTE REVIEW #2 ** | | OK, HOWEVER SEE NEW NOTES A | | COMPLETELY NEW RISER WAS SUBMITTED. | | | | ** PREVIOUS REVIEW NOTE REVIEW #1 ** | | PLEASE VERIFY THE SIZE OF MAIN | | AND METER, AS THE 320A OF METER AND THE | | LOADS CALCS AFTER DERATINGS, EXCEED | | THIS? | | PLEASE ADJUST AND INCREASE SIZE OF | | EQUIPMENT AS REQUIRED. | | 230.70,240 ETC. | | | | 8) NOTE: OK. | | | | 9) NOTE: OK. | | | | 10) NOTE: OK. | | | | 11) NOTE: OK, STAIRS REMOVED. | | | | 12) NOTE: OK, STAIRS REMOVED. | | | | 13) NOTE:NO, SAME NOTE, PLEASE SEE PANEL SCHEDULE(S). | | IE: EXAMPLE: MASTER BDRM LT., KITCHEN LT'S, BERM #2 | | RECEPTS, HALLWAY LT'S ETC | | IT IS KNOWN THAT DURING CONSTRUCTION THESE CIRCUITS AND | | LOCATIONS WILL CHANGE HOWEVER A MIN SCHEDULE FOR BRANCH | | CIRCUITS ARE REQUIRED AT THIS TIME. | | | | ** PREVIOUS REVIEW NOTE REVIEW #2** | | NO, PLEASE SEE SPECIFIC ROOMS | | AND AREAS ARE NOT LISTED ON PLANS. | | | | ** PREVIOUS REVIEW NOTEREVIEW #1** | | PLEASE SUBMIT AND COMPLETE THE | | PANEL SCHEDULES INDICATING ALL | | CIRCUITS, WIRE SIZES, AND OCP FOR EACH. | | CIRCUITS SHALL BE SPECIFIC TO RMS AND | | AREAS. | | 408.4, 240.4, 310.16 ETC. | | PLEASE SEE NOTES ABOVE AS MANY ITEMS ON | | PLANS, DO NOT MATCH. | | | | 14) NOTE: OK, HOWEVER SEE NEW NOTE FOR OCP FOR STEAM | | UNIT. | | | | 15) NOTE: OK. | | | | 16) NOTE: OK. | | | | 17) NOTE: OK. HOWEVER SEE MINOR NEW NOTE FOR STEAM UNIT | | OCP. | | | | 18) NOTE: OK. | | | | 19) NOTE: OK. | | | | 20) NOTE:OK. | | | | 21) NOTE: OK. | | | | 22) NOTE:OK. | | | | 23) NOTE: OK. | | | | 24) NOTE: OK, PLEASE BE SURE ANY REVISED | | PLANS ARE ALSO SIGNED, ETC. | | | | 25) NOTE:OK, PLEASE DO THE SAME AS NOTED ON BOTH | | PREVIOUS REVIEW. | | | | ** PREVIOUS REVIEW NOTE #2. | | OK, PLEASE BE SURE TO DO THE | | SAME WHEN RESUBMITTING. | | | | ** PREVIOUS REVIEW NOTE REVIEW #1 ** | | ** IMPORTANT** | | PLEASE KNOW, ONCE ALL REVIEWS ARE DONE | | AND BEFORE RESUBMITTING PLANS. PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS FROM SETS AND ONLY INSERT NEW | | REVISED SHEETS INTO TWO COMPLETE SETS | | FOR REVIEW AND STAMPING. ONLY ONE COPY | | OF THE OLD/VOIDED REMOVED SHEETS SHOULD | | BE SUBMITTED FOR REFERENCE. | | PLEASE KNOW, THIS WILL HELP TO | | ALLEVIATE ANY DELAYS INT THE PROCESSING | | OF PROJECT FOR PERMIT. | | | | ***** NEW NOTES 2ND REVIEW ****** | | | | 26 ) NOTE: OK, HOWEVER SEE NEW NOTES FROM THIRD REVIEW | | PERTAINING TO REVISED SERVICE RISER. | | | | ** PREVIOUS REVIEW NOTE , REVIEW #2 ** | | PLEASE SEE RISER DIAGRAM HAS | | NOW BEEN COMPLETELY REVISED. | | PLEASE SEE PLANS DO NOT SHOW THE | | LOCATION OF THIS NEW 400A MAIN. PLEASE | | SEE ALL MCB'S ARE BEING SHOWN AS BEING | | TAPPED FROM THIS ONE MAIN. PLEASE VERIFY | | TAPPED CONDUCTORS RULE W/ 240.21 | | DEPENDING ON WHERE MAIN IS LOCATED. | | (VERIFY THE LUGS AVAILABLE FOR THREE | | CONDUCTORS, ONLY NOTED) | | | | 27) NOTE: OK. | | | | 28) NOTE: OK, MAIN NOW REMOVED? | | | | 29) NOTE: OK, HOWEVER SEE NOTE FOR MIN SIZE ON NEW | | NOTES FOR GEC. | | | | 30) NOTE: OK. | | | | 31) NOTE:OK, SEE NEW NOTES. | | | | | | ** NEW NOTES 3RD REVIEW *** | | | | | | 32) NOTE: PLEASE SEE SERVICE HAS NOW BEEN COMPLETELY | | REVISED REMOVING THE 400A MAIN DISCONNECT AND PROVIDING | | "TAPPED" CONDUCTORS FROM A NEW 480K-7 METER CAN. PLEASE | | SEE 310.15B6 CAN NO LONGER BE USED FOR THE SEC'S AS | | RISER SHOWN NO LONGER CAN USE EXCEPTION. | | 310.15B6(HANDBOOK) 230.42A, 240.4 , 310.16 ETC. PLEASE | | SEE THE SEC'S IF BEING PROVIDED TO A FPL HAND-HOLE | | SHALL BE BASED ON THE 500A SERVICE BEING PROVIDED. | | PLEASE ALSO SEE TAPS(LUGS FOR 3CONDUCTORS ARE AVAILABLE | | FOR THE K-7, HOWEVER PLEASE VERIFY HOWCONDUCTORS ARE | | GOING TO BE INSTALLED AND THE LENGTH OF THE SEC'S FROM | | THE METER UNTIL THEY TERMINATE IN THE OCP DEVICE. | | PLEASE SEE 230.70 AS THE LENGTH INTO A BUILDING SHALL | | BE LIMITED TO THE NEAREST POINT OF ENTRANCE INTO A | | BLDG. THEPREVIOUS RISER SHOWED A MAIN WHICH WAS OK, | | AS LONG AS THE TAPPED CONDUCTORS MET 240.21, 408.16 AND | | THE LUGS WERE AVAILABLE FOR THE 400A MAIN DISCONNECT AS | | PREVIOUSLY NOTED AND THERE WERE "EQUIPMENT GROUNDING | | CONDUCTORS TO EACH PANEL WHICH WERE MISSING ON PREVIOUS | | RISER.(90.7,250.24B,250.122) | | PLEASE SEE AS SHOWN THE LENGTH OF SEC'S INTO THE | | DWELLING IS NOT PERMITTED TO BE MORE THAN 8FT (TOTAL | | LENGTH) OF UNPROTECTED CONDUCTOR 230.70, 90.4. | | | | ** PLEASE SEE THE PANEL "B" IS SHOWN WITH A 150A MCB | | WITH 3/0'S? THIS ISOK, HOWEVER ONLY NOTED. **PLEASE | | SEE THE FOLLOWWING COMMENTS AS THE SIZE OF THE SEC'S | | AND SERVICE ALSO AFFECTS THE GEC. | | | | 33) NOTE: PLEASE PROVIDE COMPLETE NEUTRAL LOAD | | CALCULATIONS FOR THE NEUTRAL LOAD AS THE SEC NEUTRAL IS | | NOW BEING SHOWN 4 TIMES SMALLER THAN THE OTHER PHASE | | SEC'S, OR ADJUST THE SEC FOR THE NEUTRAL FOR FULL | | SIZE.220.22, 310.16 | | | | 34) NOTE: PLEASE SEE BASED ON NEW NOTES FROM THIRD | | REVIEW AND NOT KNOWING HOW LARGE WILL BE OR IF RISER | | WILL BE REVISED, PLEASE SEE 250.66 AS THE GEC IS | | REQUIRED TO BE SIZED FOR THE SEC'S. PLEASE SEE 310.16, | | AS THIS WOULD BE REFLECTED TO A 2/0 MIN. | | THIS IS NOTED AT THIS TIME BASED ON RISER AS SHOWN. | | | | 35) NOTE: PLEASE SEE OCP AS NOTED ON SPECS FOR STEAM | | UNIT, INDICATES 35A OCP TO BE USED, HOWEVER PANEL | | SCHEDULE/CALCS INDICATE 40A. THIS IS AN ITEM WHICH | | COULD HAVE BEEN REDLINED, HOWEVER PLANS ARE COMING BACK | | FOR OTHER CORRECTIONS AT THIS TIME. PLEASE ADJUST. | | | | 36) NOTE: PLEASE SEE THE NOTICE OF COMMENCMENT | | SUBMITTED IS LONGER VALID AND WILL BE REQUIRED TO BE | | RE-RECORDED. PLEASE SEE FS 713.13(2) . IF WORK HAS NOT | | COMMENCES WITHIN 90DAYS OF RECORDING NOC, THE NOC IS NO | | LONGER VALID AND SHALL BECOME VOID. THIS ONLY NEEDS TO | | BE RE-RECORDED AND IS ONLY REQUIRED WHEN PICKING UP | | PERMIT. | | | | | | *** PLEASE SEE NOTE AS FIRST MENTIONED. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTRUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-08-23 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-08-23 |
Time |
12:13 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-08-23 |
Time |
07:51 |
Sent To |
P |
|
Notes |
2006-08-23 00:00:00 | **** UNSAT 2ND REVIEW **** | | | | ** PLEASE SEE SOME COMMENTS FROM | | PREVIOUS REVIEW AND SOME NEW COMMENTS | | DUE TO CHANGES IN PLANS. | | COMMENTS BELOW ARE TAKEN DIRECTLY FROM | | PREVIOUS REVIEW AND THEN NEW COMMENTS | | ARE ADDED TO BOTTOM. | | | | | | ***** UNSAT ***** | | | | ** PLEASE KNOW, DUE TO THE EXTENT OF | | COMMENTS AND SOME ITEMS NOT COMPLETE AT | | THIS TIME, THERE MAY BE COMMENTS OTHER | | THAN BELOW ON THE NEXT REVIEW. | | | | | | 1) NOTE: OK. | | | | 2) NOTE: OK. | | | | 3) NOTE: OK. | | | | 4) NOTE: NO, PLEASE SEE SOME ITEMS WERE | | ADDED AND SOME WERE CORRECTED, HOWEVER | | PLEASE SEE LOAD CALCULATIONS. PLEASE | | KNOW, THE LARGER OF THE TWO LOADS OF AN | | A/C CU AND AHU SHOULD BE FIGURED INTO | | THE LOAD CALCULATIONS. PLEASE SEE CU'S | | WITH LOADS LESS THAN HEAT BEING SHOWN. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE CORRELATE PLANS, PANEL | | SCHEDULES AND LOAD CALCULATIONS. | | PLEASE SEE PLANS, SHOW MORE A/C SYSTEMS | | THAN IN PANEL SCHEDULES OR LOAD CALCS. | | PLEASE SEE ONLY ONE CU IS SHOWN ON | | PLANS, PLEASE SEE 3- AHU'S?? | | 106.1.2, 440.11 ETC | | | | 5) NOTE: OK. | | | | 6) NOTE OK. | | | | 7) NOTE: OK, HOWEVER SEE NEW NOTES A | | COMPLETELY NEW RISER WAS SUBMITTED. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE VERIFY THE SIZE OF MAIN | | AND METER, AS THE 320A OF METER AND THE | | LOADS CALCS AFTER DERATINGS, EXCEED | | THIS? | | PLEASE ADJUST AND INCREASE SIZE OF | | EQUIPMENT AS REQUIRED. | | 230.70,240 ETC. | | | | 8) NOTE: OK, HOWEVER SEE NOTE PERTAINING | | TO A/C LOADS. | | | | 9) NOTE: OK. | | | | 10) NOTE: OK. | | | | 11) NOTE: OK, STAIRS REMOVED. | | | | 12) NOTE: OK, STAIRS REMOVED. | | | | 13) NOTE: NO, PLEASE SEE SPECIFIC ROOMS | | AND AREAS ARE NOT LISTED ON PLANS. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SUBMIT AND COMPLETE THE | | PANEL SCHEDULES INDICATING ALL | | CIRCUITS, WIRE SIZES, AND OCP FOR EACH. | | CIRCUITS SHALL BE SPECIFIC TO RMS AND | | AREAS. | | 408.4, 240.4, 310.16 ETC. | | PLEASE SEE NOTES ABOVE AS MANY ITEMS ON | | PLANS, DO NOT MATCH. | | | | 14) NOTE: NO, PLANS ONLY PROVIDE NOTES | | FOR WHERE THESE ARE GOING TO BE. NO | | DISCONNECTS, CLEARANCES, ACCESS IS BEING | | SHOWN. PLEASE SEE CODES BELOW AS | | CLEARANCES ETC CAN NOT BE VERIFIED. | | PLEASE SEE 240.24D ETC. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE INDICATE ALL EQUIPMENT | | ON PLANS FOR STEAM UNITS, ELEVATOR | | EQUIPMENT, DISCONNECTS, LT'S, GFI ETC. | | UNABLE TO REVIEW LOCATIONS FOR CODE | | COMPLIANCE AT THIS TIME. | | 110.26,240.4.240.24 ETC | | | | 15) NOTE: OK. | | | | 16) NOTE: OK. | | | | 17) NOTE: NO, THESE COULD NOT BE LOCATED | | ON PLANS OR SUBMITTED IN PACKAGES. | | NEED TO VERIFY MIN CLEARANCES ETC. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SUBMIT MANUFACTURES | | SPECS/ CUT SHEETS FOR ELEVATOR EQUIPMENT | | AND FOR STEAM UNIT EQUIPMENT. ALL SHALL | | INDICATE A LISTING FROM A NRTL. | | 110.3, 106.1.2* | | | | 18) NOTE: OK. | | | | 19) NOTE: OK. | | | | 20) NOTE:NO, PLEASE SEE A DINING RM | | CIRCUIT WAS ADDED ON PANEL SCHEDULE | | WHICH IS OK, HOWEVER IF THIS IS A | | DEDICATED CIRCUIT, THEN PLEASE SEE | | 210.11C1, 220.16 FOR MIN VA TO BE | | FIGURED FOR THIS CIRCUIT. | | 7-SM APPL CIRCUITS ARE LISTED ON PANEL | | SCHEDULE AND 7- SHOWN IN LOAD CALCS. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SEE 210.52B1, | | 210.11C1,220.16, DINING RM CIRCUIT SHALL | | BE INDICATED AS NOTED. | | | | 21) NOTE: OK. | | | | 22) NOTE:NO, PLEASE SEE DISCONNECT FOR | | CU OUTSIDE NOW, HAS BEEN MOVED BEHIND | | UNIT. THIS WAS SHOWN W/ CORRECT | | CLEARANCES ON PREVIOUS PLANS. | | PLEASE CLARIFY THE DISC'S FOR AHU'S. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SEE 110.26 FOR MIN | | CLEARANCES FOR AHU'S AND DISCONNECTS. | | | | 23) NOTE: OK. | | | | 24) NOTE: OK, PLEASE BE SURE ANY REVISED | | PLANS ARE ALSO SIGNED, ETC. | | | | 25) NOTE: OK, PLEASE BE SURE TO DO THE | | SAME WHEN RESUBMITTING. | | | | ** PREVIOUS REVIEW NOTE ** | | ** IMPORTANT** | | PLEASE KNOW, ONCE ALL REVIEWS ARE DONE | | AND BEFORE RESUBMITTING PLANS. PLEAS BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS FROM SETS AND ONLY INSERT NEW | | REVISED SHEETS INTO TWO COMPLETE SETS | | FOR REVIEW AND STAMPING. ONLY ONE COPY | | OF THE OLD/VOIDED REMOVED SHEETS SHOULD | | BE SUBMITTED FOR REFERENCE. | | PLEASE KNOW, THIS WILL HELP TO | | ALLEVIATE ANY DELAYS INT THE PROCESSING | | OF PROJECT FOR PERMIT. | | | | ***** NEW NOTES ****** | | | | 26 ) NOTE: PLEASE SEE RISER DIAGRAM HAS | | NOW BEEN COMPLETELY REVISED. | | PLEASE SEE PLANS DO NOT SHOW THE | | LOCATION OF THIS NEW 400A MAIN. PLEASE | | SEE ALL MCB'S ARE BEING SHOWN AS BEING | | TAPPED FROM THIS ONE MAIN. PLEASE VERIFY | | TAPPED CONDUCTORS RULE W/ 240.21 | | DEPENDING ON WHERE MAIN IS LOCATED. | | (VERIFY THE LUGS AVAILABLE FOR THREE | | CONDUCTORS, ONLY NOTED) | | | | 27) NOTE: PLEASE SEE ITEMS WHICH ARE NOW | | HAND WRITTEN ON RISER AND PLANS WHICH IS | | NOT PERMITTED. THESE ITEMS SHOULD BE | | PRINTED WHEN PLANS ARE RE-PRINTED. | | FBC ADMIN SECT 106.1 | | | | 28) NOTE: PLEASE SEE NOW THAT RISER HAS | | BEEN REVISED, PLEASE SEE MISSING | | "EQUIPMENT GROUNDING CONDUCTORS" FROM | | THE MAIN TO THE SUB-PANELS. | | PLEASE SEE 250.24B, 250.110, AND TABLES | | IN 250.122 FOR SIZING. | | | | 29) NOTE: PLEASE SEE MISSING CONNECTIONS | | FOR GROUNDING ELECTRODE SYSTEM TO BE | | COLD WATER PIPE (IF METAL), NEW FOOTER | | STEEL AND ANY OTHER SYSTEMS BEING | | PROVIDED. PLEASE SHOW ON RISER. | | 250.50 | | THIS WAS NOT IN PREVIOUS REVIEW NOTES | | | | 30) NOTE: PLEASE SEE POOL PUMP AND POOL | | HEATER SHOULD BE NOTED AS (FUTURE) SINCE | | THESE ARE NOT SHOWN ON PLANS AND POOL IS | | NOT PERMITTED AT THIS TIME. | | | | 31) NOTE: PLEASE SEEFS 553.80(2)(B) | | WITH RESPECT TO REPEAT COMMENTS. | | THIS IS ONLY A NOTICE. | | | | | | *** PLEASE SEE NOTE AS FIRST MENTIONED. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTRUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-07-08 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-07-08 |
Time |
15:58 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-07-08 |
Time |
15:27 |
Sent To |
Z |
|
Notes |
2006-07-08 00:00:00 | | | ***** UNSAT ***** | | | | ** PLEASE KNOW, DUE TO THE EXTENT OF | | COMMENTS AND SOME ITEMS NOT COMPLETE AT | | THIS TIME, THERE MAY BE COMMENTS OTHER | | THAN BELOW ON THE NEXT REVIEW. | | | | | | 1) NOTE: PLEASE SEE 210.52 FOR RECEPT | | SPACING. PLEASE SEE MANY LOCATIONS ON | | PLANS.2',6',12' RULE. | | | | 2) NOTE: PLEASE SEE MISSING RECEPTS FOR | | KITCHEN ISLAND, FOR ALL ELECTRICAL | | APPLIANCES, COUNTERSPACE ETC. PLEASE | | COMPLETE. | | PLEASE SEE 210.52C1-5, 210.8A6, FBC | | ADMIN SECT 106.1.2 | | | | 3) NOTE: PLEASE KNOW, SD'S SHALL BE | | LOCATED WITH IN 3' OF THE PEAK ON A | | SLPOED CEILING AND SHALL BE WITHIN 12" | | OF THE HIGHEST POINT ON A FLAT CEILING. | | NFPA-72 11.8.3 | | PLEASE ALSO SEE AREAS WHICH REQUIRE | | SD'S IN THE IMMEDIATE VICINITY OUTSIDE | | ALL SLEEPING RMS. | | 11.5.1.1 | | | | 4) NOTE: PLEASE CORRELATE PLANS, PANEL | | SCHEDULES AND LOAD CALCULATIONS. | | PLEASE SEE PLANS, SHOW MORE A/C SYSTEMS | | THAN IN PANEL SCHEDULES OR LOAD CALCS. | | PLEASE SEE ONLY ONE CU IS SHOWN ON | | PLANS, PLEASE SEE 3- AHU'S?? | | 106.1.2, 440.11 ETC | | | | 5) NOTE: PLEASE SEE MISSING GFI RECEPT | | PER 210.6 FOR CU'S. | | | | 6) NOTE PLEASE PROVIDE AIC RATINGS FOR | | MAIN(S). 110.9, ONLY SHOWN FOR SUB | | PANELS AND THE SERIES RATINGS. | | | | 7) NOTE: PLEASE VERIFY THE SIZE OF MAIN | | AND METER, AS THE 320A OF METER AND THE | | LOADS CALCS AFETR DERATINGS, EXCEED | | THIS? | | PLEASE ADJUST AND INCREASE SIZE OF | | EQUIPMENT AS REQUIRED. | | 230.70,240 ETC. | | | | 8) NOTE: PLEASE CORRLEATE PLANS, PANELS, | | AND LOAD CALCS. PLEASE SEE PLANS | | INDICATE MORE THAN ONE WASHER AND DRYER. | | ADJUST AS REQUIRED. | | 220.31, 215.5, 310.16, *106.1.2 | | | | 9) NOTE: PLEASE SEE LOADS SHOWN FOR | | WATER HEATER EXCEED BRANCH CIRCUIT | | RATING. 9KW? ON 30A BRKR? | | 240.4,310.16, 240, 220 ETC | | | | 10) NOTE: PLEASE SEE LOAD FOR STEAM UNIT | | EXCEEDS BRANCH CIRCUIT RATING FOR THE | | 1-POLE 40A BRKR. | | 240.4,310.16,240.,220 ETC | | | | 11) NOTE: PLEASE PROVIDE AN ELEVATION OF | | ELECTRICAL SERVICE INCORPORATED WITH | | STAIRS ON OUTSIDE WALL. | | PLEASE SEE 110.26 AND MIN CLEARNECES | | REQUIRED BY FPL FOR LOCATION AS SHOWN. | | | | 12) NOTE: PLEASE SEE MISSING EGRESS | | LIGHTING CONTROL REQUIRED FOR OUTSIDE | | STAIRS AT LOWER LEVEL. (3-WAY). LS 101 | | 7.8, NEC 210.70 | | | | 13) NOTE: PLEASE SUBMIT AND COMPLETE THE | | PANEL SCHEDULES INDICATTING ALL | | CIRCUITS, WIRE SIZES, AND OCP FOR EACH. | | CIRCUITS SHALL BE SPECIFIC TO RMS AND | | AREAS. | | 408.4, 240.4, 310.16 ETC. | | PLEASE SEE NOTES ABOVE AS MANY ITEMS ON | | PLANS, DO NOT MATCH. | | | | 14) NOTE: PLEASE INDICATE ALL EQUIPMENT | | ON PLANS FOR STEAN UNITS, ELEVATOR | | EQUIPMENT, DISCONNECTS, LTS, GFI ETC. | | UNABLE TO REVIEW LOCATIONS FOR CODE | | COMPLIANCE AT THIS TIME. | | 110.26,240.4.240.24 ETC | | | | 15) NOTE: PLEASE SEE 220.3B4. | | PLEASE SHOW ALL RECESSED LTS BASED ON | | MAX WATTAGE FOR FIXTURE(S). THIS MAY NOT | | BE FIGURED IN W/ 3W/PER SQ FT. | | PLEASE PROVIDE FIXTURE INFORMATION ON | | LEGEND. | | | | 16) NOTE: PLEASE SEE ENERGY CALCS | | SHALLBE SIGNED , DATED AND SEALED. | | PLEASE SEE FBC CHAPTER 13 | | FS 481.221, 471.023 | | | | 17) NOTE: PLEASE SUBMIT MANUFACTURES | | SPECS/ CUT SHEETS FOR ELEVATOR EQUIPMENT | | AND FOR STEAM UNIT EQUIPMENT. ALL SHALL | | INDICATE A LISTING FROM A NRTL. | | 110.3, 106.1.2* | | | | 18) NOTE: PLEASE CLARIFY EXTERIOR LTS ON | | A 220V CIRCUIT?? | | 310.16, 220.,240.4 ETC | | | | 19) NOTE: PLEASE INDICATE THE DEDICATED | | BATH(S) CIRCUIT(S0 PER 210.52D,210.11C3, | | MUST BE 20A AND #12. | | | | 20) NOTE: PLEASE SEE 210.52B1, | | 210.11C1,220.16, DINING RM CIRCUIT SHALL | | BE INDICATED AS NOTED. | | | | 21) NOTE: PLEASE SEE PLANS NOTE ARC | | FAULT FOR WALL OUTLETS, THIS HAS CHANGED | | IN THE 2002 NEC, WHICH WENT INTO EFFECT | | 7/1/2003. | | ALL OUTLETS" , IN BEDRMS SHALL BE | | PROTECTED. , LTS, RECEPTS, FANS, SD'S | | ETC. | | PLEASE LIST ALL THE ARC FAULT PROTECTED | | CIRCUITS ON PANEL SCHEDULE. A NOT IS NOT | | SUFFICIENT. | | 210.12B, 408.4 | | | | 22) NOTE: PLEASE SEE 110.26 FOR MIN | | CLEARENCES FOR AHU'S AND DISCONNECTS. | | | | 23) NOTE: PLEASE SEE PLANS SHALL | | INDICATE THE 2002 NEC. | | | | 24) NOTE: PLEASE SEE PLANS ARE NOT | | SIGNED, SEALED , OR DO NOT CONTAIN A | | TITLE BLOCK FOR PERSON RESPONSIBLE FOR | | PLASN AND DESIGN. | | PLEASE SEE THAT PLANS SHALL CLEARLY | | CONTAIN THE PRINTED NAME AND SIGNATURE | | OF THE PERSON RESPONSIBEL FOR PLANS AND | | DESIGN. PLEASE SEE 106 FBC AND FS 481, | | 471, 468 FOR PERSON PERMITTED TO DO | | SCOPE PF WORK AS SHOWN. | | | | 25) NOTE: ** IMPORTANT** | | PLEASE KNOW, ONCE ALL REVIEWS ARE DONE | | AND BEFORE RESUBMITTING PLANS. PLEAS BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS FROM SETS AND ONLY INSERT NEW | | REVISED SHEETS INTO TWO COMPLETE SETS | | FOR REVIEW AND STAMPING. ONLY ONE COPY | | OF THE OLD/VOIDED REMOVED SHEETS SHOULD | | BE SUBMITTED FOR REFERENCE. | | PLEASE KNOW, THIS WILL HELP TO | | ALLEAVIATE ANY DELAYS INT THE PROCESSING | | OF PROJECT FOR PERMIT. | | | | | | *** PLEASE SEE NOTE AS FIRST MENTIONED. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2008-03-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-03-07 |
Time |
11:37 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-03-07 |
Time |
11:37 |
Sent To |
E |
|
Notes |
2008-03-07 11:37:51 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2007-09-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-09-07 |
Time |
11:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-09-07 |
Time |
11:17 |
Sent To |
P |
|
Notes |
2007-09-07 11:18:09 | TO "P" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-08-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-08-03 |
Time |
09:08 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-08-03 |
Time |
09:08 |
Sent To |
B |
|
Notes |
2007-08-03 09:08:21 | TO "LMARTINEZ" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-01-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-22 |
Time |
09:49 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-22 |
Time |
09:49 |
Sent To |
B |
|
Notes |
2007-01-22 09:49:42 | TO "LMARTINEZ" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-10-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-27 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-27 |
Time |
09:00 |
Sent To |
E |
|
Notes |
2006-10-27 09:01:01 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-08-22 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-22 |
Time |
13:32 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-22 |
Time |
13:32 |
Sent To |
E |
|
Notes |
2006-08-22 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-08-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-15 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-15 |
Time |
13:12 |
Sent To |
Z |
|
Notes |
2006-08-15 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-07-17 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-07-17 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-07-07 |
Time |
13:42 |
Sent To |
|
|
Notes |
2006-07-07 00:00:00 | TO "SFR" "Z" |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2006-07-11 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-07-11 |
Time |
09:08 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2006-07-11 |
Time |
09:08 |
Sent To |
P |
|
Notes |
2006-07-11 00:00:00 | NO MECHANICAL PLANS SUBMITTED, AND NO | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | THIS TIME. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2007-09-25 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-09-25 |
Time |
09:00 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-09-25 |
Time |
09:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2006-09-06 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-09-06 |
Time |
09:22 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-09-06 |
Time |
09:22 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-07-12 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-07-12 |
Time |
10:01 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-07-12 |
Time |
10:01 |
Sent To |
B |
|
Notes |
2006-07-12 00:00:00 | DENIED; | | 1.RISER DIAGRAM DOES NOT MATCH FLOOR | | PLAN. (NO BATHROOM NEXT TO KITCHEN) | | 2.BOTH BIDETS ARE NOT VENTED. (TOILET | | FLUSHES PAST BIDET NO VENT) | | 3.PLEASE SIZE TRUNK LINE ALL THE WAY TO | | KITCHEN. | | 4. MASTER BATH FIRST FLOOR LAV STACK CAN | | NOT BE INSTALLED AS DRAWN. (DOOR BETWEEN | | LAVS) | | ONE SET OF PLANS MARKED IN RED. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2008-05-06 |
|
|
Cont ID |
|
Sent By |
choops |
Date |
2008-05-06 |
Time |
16:00 |
Rev Time |
0.00 |
Received By |
choops |
Date |
2008-05-06 |
Time |
16:00 |
Sent To |
PC |
|
Notes |
2008-05-06 16:07:20 | ***APPROVED - LANDSCAPE PLAN SUBMITTAL*** | | | | PROVISOS: | | 1)PLANT MATERIALS USED PURSUANT TO THE PROVISIONS OF | | THIS SECTION SHALL BE EQUAL TO OR BETTER THAN FLORIDA | | DEPARTMENT OF AGRICULTURE NUMBER 1 NURSERY GRADE | | STANDARD. | | | | 2)REQUIRED IRRIGATION SYSTEM SHALL BE INSTALLED IN | | BOTH THE YARD AND PARKWAY/SWALE AREA (IF APPLICABLE). | | | | 3)BAMBOO TO BE INSTALLED AS SHOWN, 5 FEET FROM FRONT | | RIGHT-OF-WAY. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2006-08-19 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-08-19 |
Time |
15:15 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-08-19 |
Time |
15:15 |
Sent To |
I |
|
Notes |
2006-08-19 00:00:00 | NOTE: THE PROPOSED A/C UNITS SHALL NOT | | BE CLOSER THAN 1FT ON THE EAST SIDE | | PROPERTY & 6FT ON THE WEST SIDE | | PROPERTY. | | | | NOTE: MUST PULL A SEPARATE PERMIT FOR | | ANY PROPOSED CBS WALL/FENCE/GATE WITH AN | | APPROVAL FROM THE CITY OF WEST PALM | | BEACH UTILITY DEPT. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-07-10 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-07-10 |
Time |
14:03 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-07-10 |
Time |
14:03 |
Sent To |
M |
|
Notes |
2006-07-10 00:00:00 | DENIED, | | 1. THE PROPOSED STRUCTURE MUST MEET THE | | SIDE SETBACK OF 15FT TOTAL (THE LOCATION | | OF PROPOSED STAIRS AND WEST SIDE DOES | | NOT MEET THE 15FT TOTAL) SEC94-305 #9 | | (OUTSIDE STAIRWAYS OVER 3FT IN HEIGHT | | ABOVE GRADE SHALL MEET ALL REQUIREMENTS | | OF THE MAIN STRUCTURE). (SITEPLANS DOES | | NOT GIVE ALL SETBACKS). | | 2. MUST SHOW THE LOCATION OF THE | | PROPOSED A/C UNIT THE TWO COPY OF | | SURVEYS (SITEPLANS DOES NOT GIVE ALL | | SETBACKS). | | 3. MUST PROVIDE DIMENSION OF THE | | PROPOSED DRIVEWAY (WIDTH) ON TWO COPY OF | | CURRENT SURVEYS. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|
|