Plan Review Details - Permit 06070104
Plan Review Stops For Permit 06070104
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-08-04 Cont ID  
Sent By shill Date 2006-08-04 Time 16:08 Rev Time 0.00
Received By shill Date 2006-08-04 Time 16:08 Sent To  
Notes
2006-08-04 00:00:00PROVISO
  
 NO OPENINGS <20SF IN ZONE 5
 PROVIDE SCHEDULE OF OPENING SIZES AT
 INSPECTION

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-07-31 Cont ID  
Sent By shill Date 2006-07-31 Time 14:14 Rev Time 0.00
Received By shill Date 2006-07-31 Time 14:13 Sent To  
Notes
2006-07-31 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED
 ITEMS APPLY
  
 _XX_4.COMPLETE THE ATTACHED
 INSTALLATION SCHEDULE OR PROVIDE
 REQUIRED INFORMATION IN A SIMILAR
 FORMAT.YOU MAY SHOW ANCHOR SPACING BY
 CIRCLING IT ON THE APPROPRIATE CHARTS ON
 THE PRODUCT APPROVAL.PLEASE USE INK
 RATHER THAN HIGHLIGHTER.
  
 _XX_5.FLORIDA STATE OR LOCAL PRODUCT
 APPROVAL REQUIRED, FAC9B72,
 WWW.FLORIDABUILDING.ORG.
  
 PLEASE TO TO WWW.FLORIDABUILDING.ORG AND
 PRINT THE FLORIDA STATE PRODUCT APPROVAL
 COVER SHEET FOR THIS PRODUCT.
  
 _XX_8.PROVIDE A FLOOR PLAN SHOWING
 WHERE THE SHUTTERS WILL BE INSTALLED AND
 PANEL SIZES WHICH CORRELATES WITH THE
 INSTALLATION SCHEDULE, ITEM 4 ABOVE.
  
  
 NEW COMMENT:
  
 THE FLOOR PLAN WAS PROVIDED BUT DOES NOT
 SHOW SIZES.YOU HAVE CIRCLED -40PSF,
 12IN SPACING.IT IS NOT CLEAR FROM THE
 FLOOR PLAN IF ANY OPENINGS ARE IN ZONE
 5.20SF AND SMALLER OPENINGS IN ZONE 5
 WOULD HAVE A DESIGN PRESSURE GREATER
 THAN -40PSF.CODE COMPLIANCE CANNOT BE
 DETERMINED FROM THE INFORMATION
 PROVIDED.
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-07-11 Cont ID  
Sent By shill Date 2006-07-11 Time 13:55 Rev Time 0.00
Received By shill Date 2006-07-11 Time 13:55 Sent To  
Notes
2006-07-11 00:00:00****CORRECTIONS****
  
 SAMANTHA HILL, BUILDING PLANS EXAMINER
 561-805-6724 [email protected]
  
 FBC FLORIDA BUILDING CODE 2004
 FBC* CITY OF WEST PALM BEACH AMENDMENTS
 TO THE FBC2004
  
 SHUTTER PERMIT APPLICATION, ONLY CHECKED
 ITEMS APPLY
  
 _XX_1.A NOTICE OF COMMENCEMENT MUST
 BE FILED WITH THE CLERK OF COURTS BEFORE
 A PERMIT CAN BE ISSUED, FS713.13.
  
 _XX_2.PROVIDE BUILDING HEIGHT ON THE
 PLAN.DESIGN PRESSURES FOR BUILDINGS
 OVER 60FEET ARE REQUIRED TO BE DESIGNED
 USING ASCE7, FBC1609.1.1 AND MUST BE
 DONE BY AN ENGINEER. DOCUMENTS PREPARED
 BY AN ENGINEER AND SUBMITTED FOR PUBLIC
 RECORD ARE TO BE SIGNED SEALED ORIGINALS
 FAC61G15-23.002.
  
 ____3.PROVIDE A COPY OF THE CONDO
 ASSOCIATION APPROVAL.
  
 _XX_4.COMPLETE THE ATTACHED
 INSTALLATION SCHEDULE OR PROVIDE
 REQUIRED INFORMATION IN A SIMILAR
 FORMAT.YOU MAY SHOW ANCHOR SPACING BY
 CIRCLING IT ON THE APPROPRIATE CHARTS ON
 THE PRODUCT APPROVAL.PLEASE USE INK
 RATHER THAN HIGHLIGHTER.
  
 _XX_5.FLORIDA STATE OR LOCAL PRODUCT
 APPROVAL REQUIRED, FAC9B72,
 WWW.FLORIDABUILDING.ORG.
  
 _XX_6.ON THE PRODUCT APPROVAL, MARK
 WHICH DETAILS APPLY TO THIS JOB.PLEASE
 USE INK RATHER THAN A HIGHLIGHTER.
  
 _XX_7.SHOW THE EMERGENCY MEANS OF
 ESCAPE, FBC R310.
  
 _XX_8.PROVIDE A FLOOR PLAN SHOWING
 WHERE THE SHUTTERS WILL BE INSTALLED AND
 PANEL SIZES WHICH CORRELATES WITH THE
 INSTALLATION SCHEDULE, ITEM 4 ABOVE.
  
  

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-07-20 Cont ID  
Sent By adarroug Date 2006-07-20 Time 13:38 Rev Time 0.00
Received By adarroug Date 2006-07-20 Time 13:38 Sent To B
Notes
2006-07-20 00:00:00TO "SHILL" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-07-11 Cont ID  
Sent By shill Date 2006-07-11 Time 13:56 Rev Time 0.00
Received By shill Date 2006-07-07 Time 09:49 Sent To  
Notes
2006-07-07 00:00:00TO "MISC" BOX#1