Plan Review Details - Permit 06061717
Plan Review Stops For Permit 06061717
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2007-01-09 Cont ID  
Sent By jwitmer Date 2007-01-09 Time 18:02 Rev Time 0.77
Received By jwitmer Date 2007-01-09 Time 18:00 Sent To  
Notes
2007-01-09 18:03:22BUILDING PROVISO:
  
 3001.1 SCOPE.
 THIS CHAPTER GOVERNS THE DESIGN, CONSTRUCTION,
 INSTALLATION, ALTERATION AND REPAIR OF ELEVATORS AND
 CONVEYING SYSTEMS AND THEIR COMPONENTS.
  
 NOTE: OTHER ADMINISTRATIVE AND PROGRAMMATIC PROVISIONS
 MAY APPLY. SEE THE DEPARTMENT OF BUSINESS AND
 PROFESSIONAL REGULATION [DBPR] CHAPTER 399, FLORIDA
 STATUTES, AND 61C-5, FLORIDA ADMINISTRATIVE CODE . THE
 REGULATION AND ENFORCEMENT OF THE FOLLOWING SECTIONS OF
 THE ADOPTED CODES, AND THEIR ADDENDA, ARE PREEMPTED TO
 THE BUREAU OF ELEVATOR SAFETY OF THE DEPARTMENT OF
 BUSINESS AND PROFESSIONAL REGULATION: ASME A 17.1, PART
 8, ASME A17.3, SECTIONS 1.2, 1.5, ASME A 18.1, PART 10.
  
  
 BUILDING PLAN REVIEW
 JIM WITMER C. B. O.
  
 TEL: (561)805-6715
 FAX: (561)659-8026
 E-MAIL: [email protected]
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-10-04 Cont ID  
Sent By jwitmer Date 2006-10-04 Time 07:35 Rev Time 0.88
Received By jwitmer Date 2006-10-04 Time 07:35 Sent To  
Notes
2006-10-04 00:00:00BUILDING PLAN REVIEW
 PERMIT: 06061717
 ADD: 1001 OKEECHOBEE BLVD
 CONT: CHA TECH SERVICES, LLC
 TEL: (770)286-7297
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 2ND REVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 3) COMMENT# 7 FROM THE PREVIOUS REVIEW
 DEALS WITH THE CONDUITS IN THE
 STAIRWELL, THAT ARE ENCASED IN A 2
 LAYERS OF ROCK, 1" FIRECORE C CORE PANEL
 AND 1/2" DRYWALL. PLEASE PROVIDE THE
 LISTING FOR A 2 HR ASSEMBLY. 703.2
 FIRE-RESISTANCE RATINGS.
  
 THE SECOND ISSUE IS THE LOCATION OF
 THIS ASSEMBLY IN THE STAIRWELL. 1009.4
 STAIRWAY LANDINGS. THERE SHALL BE A
 FLOOR OR LANDING AT THE TOP AND BOTTOM
 OF EACH STAIRWAY. THE WIDTH OF LANDINGS
 SHALL NOT BE LESS THAN THE WIDTH OF
 STAIRWAYS THEY SERVE. EVERY LANDING
 SHALL HAVE A MINIMUM DIMENSION MEASURED
 IN THE DIRECTION OF TRAVEL EQUAL TO THE
 WIDTH OF THE STAIRWAY. SUCH DIMENSION
 NEED NOT EXCEED 48 INCHES (1219 MM)
 WHERE THE STAIRWAY HAS A STRAIGHT RUN.
 E07 INDICATES THAT THE SHAFT
 ENCLOSURE WILL BE 8" AWAY FROM THE WALL
 BUT THE LENGTH IN NOTE# 1 IS AS NEEDED.
 THIS COULD BE ACROSS THE WHOLE LANDING.
 1009.4 STATES THE WIDTH OF LANDINGS
 SHALL NOT BE LESS THAN THE WIDTH OF THE
 STAIRWAYS THEY SERVE.
  
 THE THIRD ISSUE IS LOCATED ON E01 NOTE
 NUMBER 24, JUNCTION BOX SIZE AS REQUIRED
 BY THE NEC. THE ELECTRICAL PLAN REVIEWER
  
 MAY COMMENT ON THIS ISSUE. THERE CAN BE
 NO JUNCTION BOXES THAT WILL COMMUNICATE
 WITHIN THE STAIR TOWER. SEE ORIGINAL
 COMMENT 1019.2 PENETRATIONS INTO AND
 OPENINGS THROUGH AN EXIT ENCLOSURE.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-08-08 Cont ID  
Sent By jwitmer Date 2006-08-08 Time 15:15 Rev Time 0.00
Received By jwitmer Date 2006-08-08 Time 15:15 Sent To  
Notes
2006-08-08 00:00:00BUILDING PLAN REVIEW
 PERMIT: 06061717
 ADD: 1001 OKEECHOBEE BLVD
 CONT: CHA TECH SERVICES, LLC
 TEL: (770)286-7297
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 * WEST PALM BEACH AMENDMENTS
  
 1ST REVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 3) CHA, CLOUGH HARBOUR & ASSOCIATESLLP
 PLEASE PROVIDE THE ADDRESS AS STATED
 UNDER THE CERTIFICATE OF AUTHORIZATION
 FILED WITH THE STATE. IF THIS LOCATION
 IS A SECOND OFFICE THE OFFICE REGISTERED
 WITH STATE IS REQUIRED, THIS SECONDARY
 ADDRESS THEN MAY BE INCLUDED.
  
 4) THE TITLE BLOCK LIST PB MARKETPLACE
 AS THE LOCATION FOR THE JOB? THIS
 ADDRESS IS FOR THE "MARRIOT".PLEASE
 CORRECT THE TITLE BLOCK. 61G15-23.002.
  
 5) 110.2* W. P. B. ADMINISTRATIVE CODE,
 INFORMATION THAT IS REQUIRED FOR RECORD
 KEEPING & FOR CERTIFICATE OF OCCUPANCY:
 A) THE EDITION OFTHE CODE UNDER WHICH
 THE PERMIT WAS ISSUED.
 B) THE USE AND OCCUPANCY, IN ACCORDANCE
 WITH THE PROVISIONS OF CHAPTER 3.
 C) THE TYPE OF CONSTRUCTION AS DEFINED
 IN CHAPTER 6, TABLE 601. LEVEL OF
 ALTERATION EXISTING BUILDING CODE.
 D) THE DESIGN OCCUPANT LOAD, SEE 1004.
 E) IF AN AUTOMATIC SPRINKLER SYSTEM IS
 PROVIDED, WHETHER THE SPRINKLER SYSTEM
 IS REQUIRED.
 F) ANY SPECIAL STIPULATIONS & CONDITIONS
 OF THE BUILDING PERMIT.
  
 6) SHEET CO4 DETAIL# 5 FOR WALL AND
 CEILING, PLANS INDICATE THAT UL LISTING
 U-334 WILL BE USED. PLANS INDICATE A 2
 HR RATED WALL WHEREAS THE DETAIL
 INDICATES ONLY ONE LAYER OF 5/8" DRYWALL
 BUT THE UL LISTING REQUIRES 2 LAYERS.
 THE OTHER ISSUE IS THE LISTING INDICATES
 THE USE OF WOOD STUDS FOR A BEARING
 WALL. IS THIS TO BE USED AS A BEARING
 WALL.? THE OTHER ISSUE IS WOOD STUDS
 BEING USED IN A TYPE 1A BUILDING.
 WILL THERE BE FIRE SPRINKLERS ADDED TO
 THIS SPACE OR A DRY SYSTEM (HALON)?
  
 7) SHEET E01 INDICATES CONDUITS TO BE
 INSTALLED IN THE STAIR TOWER.1019.1.2
 PENETRATIONS.
 PENETRATIONS INTO AND OPENINGS THROUGH
 AN EXIT ENCLOSURE ARE PROHIBITED EXCEPT
 FOR REQUIRED EXIT DOORS, EQUIPMENT AND
 DUCTWORK NECESSARY FOR INDEPENDENT
 PRESSURIZATION, SPRINKLER PIPING,
 STANDPIPES, ELECTRICAL RACEWAY FOR FIRE
 DEPARTMENT COMMUNICATION AND ELECTRICAL
 RACEWAY SERVING THE EXIT ENCLOSURE AND
 TERMINATING AT A STEEL BOX NOT EXCEEDING
 16 SQUARE INCHES (0.010 M 2 ). SUCH
 PENETRATIONS SHALL BE PROTECTED IN
 ACCORDANCE WITH SECTION 712 . THERE
 SHALL BE NO PENETRATIONS OR
 COMMUNICATION OPENINGS, WHETHER
 PROTECTED OR NOT, BETWEEN ADJACENT EXIT
 ENCLOSURES.
 BUILDING PLAN REVIEW
 JIM WITMER
 TEL: (561)805-6715
 FAX: (561)659-8026

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-12-31 Cont ID  
Sent By dpalmer Date 2006-12-31 Time 16:00 Rev Time 0.00
Received By dpalmer Date 2006-12-31 Time 15:41 Sent To  
Notes
2006-12-31 16:02:46** REDLINED NOTES **
  
  
 1) MCB ON THE SECONDARY SIDE OF THE TRANSFORMER SHALL
 BE INSTALLED WITHIN 25FT OF CONDUCTORS MAX PER
 240.21C.
 OCP TO BE PER PLANS, 200A MAX.
 2) THE GENERATOR CHANGE OUT/UPGRADE SHALL BE COMPLETED
 BEFORE FINAL ON THIS PERMIT CAN BE GRANTED.
  
  
 *** OWES $1,210 FOR INCREASED VALUE. MUST BE PAID
 BEFORE PERMIT CAN PRINT.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-09-18 Cont ID  
Sent By dpalmer Date 2006-09-18 Time 14:49 Rev Time 0.00
Received By dpalmer Date 2006-09-18 Time 12:39 Sent To  
Notes
2006-10-04 00:00:00**** PLEASE SEE 300.19A FOR SIZE AND
 LENGTH OF CONDUCTORS.
 SUPPORTS WHICH WOULD REQUIRE SOME TYPE
 OF PULL BOXES, WOULD NOT BE PERMITTED IN
 STAIRTOWERS.
2006-09-18 00:00:00**** UNSAT 2ND REVIEW ***
  
 ** PLEASE SEE SOME NOTE FROM PREVIOUS
 REVIEW AND SOME NEW NOTES DUE TO
 INFORMATION ON PLANS.
 PLEASE SEE NOTES BELOW ARE TAKEN
 DIRECLTY FROM PREVIOUS REVIEW WITH NEW
 NOTES ADDED AT THE BOTTOM.
  
  
  
  
 1) NOTE: NO, EXISTING RISER, OCP, SIZE
 ETC STILL NEEDS TO BE SHOWN.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE CLARIFY AND SPECIFY THE
 TYPE OF EM DISTRIBUTION SYSTEMTHIS NEW
 PROPOSED CONNECTION IS COMING FROM.
 PLEASE KNOW, AS SHOWN THIS MAY NOT BE
 TAPPED FROM THE EXISTING EM DIST SYSTEM.
 PLEASE KNOW THERE IS MUCH INFORMATION
 NOT SUBMITTED FOR CONSIDERATION TO DO
 SO.
 700,701,NFPA-110CHAPTERS 5,6,7.
  
 2) NOTE:NO, PLEASE SEE DETAIL AS SHOWN
 FOR STAIRS IS STILL IN QUESTION, AND
 CONFORMATION WITH THE BUILDING REVIEW
 APPEARS THE SIZE OF REQUESTED ENCLOSURE
 IS TOO LARGE IN STAIRS.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEE BUILDING AND FIRE
 REVIEW COMMENTS, AS CONDUITS SHOWN ARE
 BEING PROPOSED IN THE STAIR WAYS WHICH
 ARE NOT PERMITTED. NO EXCEPTIONS.
  
 3) NOTE:NO, PLEASE KNOW THAT NO
 VERIFICATION OF EXISTING CAN BE DONE AS
 THE PERMITTING , INSTALLATION AND
 UPGRADE FOR EXISTING OLD GENERATOR IS
 NOT YET DONE.
 ** PLEASE SEE NOTE WHICH MENTIONS "KEMM"
 CONSULTING.? PLEASE VERIFY ,AS THIS MAY
 BE A MISPRINT FOR NAME.
 PLEASE KNOW, AS THESE ARE NOW PART OF A
 LEGALLY REQUIRED SYSTEM, SIZING ,
 LOCATION ETC MUST BE VERIFIED.
  
 ** PREVIOUS REVIEW NOTE **
  
 PLEASE PROVIDE LOAD
 CALCULATIONS FOR ALL PROPOSED LOADS
 BEING ADDED TO EXISTING LOADS.
 DEPENDING ON THE CONNECTIONS OF THE EM
 DIST SYSTEM AND TRANSFER DEVICES ETC, IT
 IS KNOWN TO THIS OFFICE THAT THIS
 BUILDING (MARRIOTT HOTEL) IS CURRENTLY
 PROPOSING THE INSTALLATION OF A NEW EM
 GEN AND DIST SYSTEM WHICH IS NOT YET
 PERMITTED.
 PLEASE KNOW, COMPLETE LOAD CALCS AND/OR
 DEMANDS AND NEW LOADS ARE REQUIRED AT
 THIS TIME. THERE WILL BE NO EXCEPTIONS
 OR "PROVISOS" (CONDITION TO ISSUE)
 GRANTED.
 220, 215.5, ETC
 106.1.2 FBC ADMIN SECT
  
 4) NOTE: NO, PLEASE SEE PLANS STILL
 INDICATE THE 2005. THIS WAS REDLINED AND
 HIGHLIGHTED ON PLANS.
  
 ** PREVIOUS REVIEW NTOE **
 PLEASE SEE PLANS CURRENTLY CALL
 FOR THE 2005 NEC. PLEASE KNOW, THE STATE
 OF FLORIDA IS STILL CURRENTLY UNDER
 UNDER THE 2002 NFPA-70
  
 5) NOTE: NO?? THIS IS IN QUESTION , AS
 ALL EQUIPMENT BEING SHOWN ON PLANS AND
 LABOUR FOR INSTALLATION SEEMS TO BE
 HIGHER THAN SHOWN ON APPLICATION.
 SIGNED, DATED AND NOTARIZED CONTRACT(S)
 ARE REQUIRED. FBC 108.3.
 THIS SCOPE IS FOR ALL ELECTRICAL ,
 BUILDING, MECHANICALETC.
  
 ** PLEASE SEE VALUE SHALL BE BASED
 ON ALL LABOR AND MATERIALS, EVEN IF ANY
 OF THE EQUIPMENT OR MATERIALS ARE OWNER
 SUPPLIED. PLEASE KNOW, IF VALUE IS NOT
 ADJUSTED, ONE WILL BE ASSESSED BY THIS
 OFFICE USING GUIDES AS ADOPTED INTO THE
 FBC. 108.3 ADMIN SETC.
  
 6) NOTE: NO, PLEASE SEE SOME NOTES SHOWN
 ON SHEETS DO NOT CORRELATE WITH "CODED
 NOTES", PLEASE SEE UNABLE TO VERIFY SOME
 ITEMS.
 240.21, PANEL ON SECONDARY SIDE OF THE
 TRANSFORMER ETC.
  
 ** PREVIOUS REVIEW NOTE**
 PLEASE COMPLETE PLANS , NOTES
 AND RISER. PLEASE SEE THERE ARE
 NUMERICAL NOTES ON PLANS WHICH ARE SHOWN
 SHOWN ON NOTES.. PLEASE PLACE NOTES AND
 INFORMATION ON RISER. THIS WILL HELP THE
 REVIEW PROCESS OF JUMPING BACK AND FORTH
 FROM PAGES. PLEASE SEE NOTES ONLY GO
 THROUGH 24.
 106.1.2.,90.7
  
 7) NOTE: OK.
  
 8) NOTE: OK.
  
 PLEASE SEE COMMENTS FROM OTHER
 REVIEWER(S).
  
 9) NOTE: PLEASE SEE FS 553.80(2)(B) WITH
 RESPECT TO REPEAT CODE COMPLIANT
 COMMENTS. THIS IS ONLY NOTED AT THIS
 TIME.
  
 ** IMPORTANT**
  
 ONCE ALL REVIEWS ARE DONE, PLANS ARE
 PICKED UP AND BEFORE RESUBMITTING.
 PLEASE COMPLETELY REMOVED ALL OLD/VOIDED
 SHEETS FROM SETS AND ONLY INSERT NEW
 REVISED SHEETS INTO COMPLETE SETS FOR
 REVIEW AND STAMPING.
 ONLY ONE COPY OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED BACK FOR REFERENCE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-07-21 Cont ID  
Sent By dpalmer Date 2006-07-21 Time 18:42 Rev Time 0.00
Received By dpalmer Date 2006-07-21 Time 17:52 Sent To  
Notes
2006-07-21 00:00:00************ UNSAT ****************
  
 ** PLEASE SEE THE FOLLOWING COMMENTS AS
 THE DESIGN AS SHOWN WILL NOT BE
 PERMITTED AND CHANGES WILL BE REQUIRED.
  
 1) NOTE: PLEASE CLARIFY AND SPECIFY THE
 TYPE OF EM DISTRIBUTION SYSTEMTHIS NEW
 PROPOSED CONNECTION IS COMING FROM.
 PLEASE KNOW, AS SHOWN THIS MAY NOT BE
 TAPPED FROM THE EXISTING EM DIST SYSTEM.
 PLEASE KNOW THERE IS MUCH INFORMATION
 NOT SUBMITTED FOR CONSIDERATION TO DO
 SO.
 700,701,NFPA-110CHAPTERS 5,6,7.
  
 2) NOTE: PLEASE SEE BUILDING AND FIRE
 REVIEW COMMENTS, AS CONDUITS SHOWN ARE
 BEING PROPOSED IN THE STAIR WAYS WHICH
 ARE NOT PERMITTED. NO EXCEPTIONS.
  
 3) NOTE: PLEASE PROVIDE LOAD
 CALCULATIONS FOR ALL PROPOSED LOADS
 BEING ADDED TO EXISTING LOADS.
 DEPENDING ON THE CONNECTIONS OF THE EM
 DIST SYSTEM AND TRANSFER DEVICES ETC, IT
 IS KNOWN TO THIS OFFICE THAT THIS
 BUILDING (MARRIOTT HOTEL) IS CURRENTLY
 PROPOSING THE INSTALLATION OF A NEW EM
 GEN AND DIST SYSTEM WHICH IS NOT YET
 PERMITTED.
 PLEASE KNOW, COMPLETE LOAD CALCS AND/OR
 DEMANDS AND NEW LOADS ARE REQUIRED AT
 THIS TIME. THERE WILL BE NO EXCEPTIONS
 OR "PROVISOS" (CONDITION TO ISSUE)
 GRANTED.
 220, 215.5, ETC
 106.1.2 FCB ADMIN SECT
  
 4) NOTE: PLEASE SEE PLANS CURRENTLY CALL
 FOR THE 2005 NEC. PLEASE KNOW, THE STATE
 OF FLORIDA IS STILL CURRENTLY UNDER
 UNDER THE 2002 NFPA-70
  
 5) NOTE: PLEASE SEE VALUE SHALL BE BASED
 ON ALL LABOR AND MATERIALS, EVEN IF ANY
 OF THE EQUIPMENT OR MATERIALS ARE OWNER
 SUPPLIED. PLEASE KNOW, IF VALUE IS NOT
 ADJUSTED, ONE WILL BE ASSESSED BY THIS
 OFFICE USING GUIDES AS ADOPTED INTO THE
 FBC. 108.3 ADMIN SETC.
  
 6) NOTE: PLEASE COMPLETE PLANS , NOTES
 AND RISER. PLEASE SEE THERE ARE
 NUMERICAL NOTES ON PLANS WHICH ARE SHOWN
 SHOWN ON NOTES.. PLEASE PLACE NOTES AND
 INFORMATION ON RISER. THIS WILL HELP THE
 REVIEW PROCESS OF JUMPING BACK AND FORTH
 FROM PAGES. PLEASE SEE NOTES ONLY GO
 THROUGH 24.
 106.1.2.,90.7
  
 7) NOTE: PLEASE CLARIFY TITLE BLOCKS AS
 ADDRESSING INFORMATION FOR SAID ENGINEER
 AND FIRM DO NOT SEEM TO CORRELATE WITH
 THE STATE'S WEBSITE. PLEASE SEE ATTACHED
 COPIES PRINTED FROM THE DEPARTMENT OF
 BUSINESS AND PROFESSIONAL REGULATION.
 FAC 61G15-23.002, FS 471
  
 8) NOTE: PLEASE SEE LOCATION OF PROJECT
 IS NOTED AS "PB MARKETPLACE"?? THIS
 BUIDLING IS THE MARRIOTT HOTEL. PLEASE
 ADJUST TITLE BLOCKS.
 FAC 61G15-23.002
  
 PLEASE SEE COMMENTS FROM OTHER
 REVIEWER(S).
  
 ** IMPORTANT**
  
 ONCE ALL REVIEWS ARE DONE, PLANS ARE
 PICKED UP AND BEFORE RESUBMITTING.
 PLEASE COMPLETELY REMOVED ALL OLD/VOIDED
 SHEETS FROM SETS AND ONLY INSERT NEW
 REVISED SHEETS INTO COMPLETE SETS FOR
 REVIEW AND STAMPING.
 ONLY ONE COPY OF THE OLD/VOIDED SHEETS
 SHOULD BE SUBMITTED BACK FOR REFERENCE.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status P Date 2007-01-11 Cont ID  
Sent By mawillia Date 2007-01-11 Time 11:03 Rev Time 0.00
Received By mawillia Date 2007-01-11 Time 11:03 Sent To  
Notes
2007-01-11 11:08:13*****APPROVED*****
  
  
 SHEET NUMBERS CO-2 AND EO-5, WHICH SHOWS/DISPLAYS THAT
 THE ELETRICAL CONDUITS WILL NOT PENETRATE THE FIRE
 RATED STAIRWELL, WERE STAMPED, INITIALED, AND DATED.

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status F Date 2006-10-03 Cont ID  
Sent By mawillia Date 2006-10-03 Time 13:23 Rev Time 0.00
Received By mawillia Date 2006-10-03 Time 13:23 Sent To  
Notes
2006-10-03 00:00:00*****DENIED*****
  
  
 1.) CONTRARY TO YOUR COMMENT RESPONSE
 SHEET DATED AUGUST 30TH,2006, THE
 RESUBMITTED PLANS STILL REFLECT THAT THE
 SCOPE OF THE WORK WILL ENTAIL THAT THE
 CONDUIT (ALTHOUGH ENCLOSED IN A 2 HOUR
 RATED CHASE) PENETRATES A FIRE RATED
 STAIRWELL.AS STATED IN THE PREVIOUS
 FIRE PLAN REVIEW, PENETRATIONS INTO, AND
 OPENINGS THROUGH, AN EXIT ENCLOSURE
 ASSEMBLY SHALL BE LIMITED TO THOSE AS
 RECORDED IN NFPA 101, 2003 EDITION,
 SECTION 7.1.3.2.1.(6).
  
  
  
  
  
 CAPT. MICHAEL A. WILLIAMS
 FIRE PLAN REVIEW
 561-805-6722

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2006-08-09 Cont ID  
Sent By mwennerg Date 2006-08-09 Time 11:34 Rev Time 0.00
Received By mwennerg Date 2006-08-09 Time 11:34 Sent To  
Notes
2006-08-09 00:00:00***DENIED***
  
 1) ALL EQUIPMENT INSTALLATIONS SHALL NOT
 INTERFERE WITH FIRE PROTECTION EQUIPMENT
 INSIDE BUILDING OR ON ROOF.
  
 2) NO EQUIPMENT WILL BE ALLOWED INSIDE
 OF STAIRWELLS. PLEASE SEE NFPA 101, 2003
 EDITION SEC. 7.1.3.2.1.(6).
  
 3) PLEASE INDICATE SPECIFIC NFPA CODES
 THAT WILL BE COMPLIED WITH AS STATED ON
 M0.1, NOTE 10. PLEASE INCLUDE
 APPROPRIATE EDITIONS.
  
  
 MIKE WENNERGREN, CAPTAIN/WPBFR
 FIRE PLAN REVIEW (561) 805-6722
  

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-12-08 Cont ID  
Sent By adarroug Date 2006-12-08 Time 14:51 Rev Time 0.00
Received By adarroug Date 2006-12-08 Time 14:51 Sent To  
Notes
2006-12-31 14:59:22TO COMM BOARD #44, 12/31
2006-12-08 14:51:59WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-09-09 Cont ID  
Sent By adarroug Date 2006-09-09 Time 15:49 Rev Time 0.00
Received By adarroug Date 2006-09-09 Time 15:49 Sent To  
Notes
2006-09-15 00:00:00TO "COMM" BD#27
2006-09-09 00:00:00WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-08-25 Cont ID  
Sent By tgordon Date 2006-08-25 Time 11:29 Rev Time 0.00
Received By tgordon Date 2006-07-05 Time 15:53 Sent To  
Notes
2006-07-19 00:00:00TO "COMM" BD#34
2006-07-05 00:00:00WAITING FOR "COMM" BD

Review Stop M MECHANICAL (A/C)
Rev No 3 Status P Date 2007-01-08 Cont ID  
Sent By tgordon Date 2007-01-02 Time 11:25 Rev Time 0.30
Received By tgordon Date 2007-01-02 Time 11:25 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-09-19 Cont ID  
Sent By tgordon Date 2006-09-19 Time 08:14 Rev Time 0.20
Received By tgordon Date 2006-09-19 Time 08:14 Sent To  
Notes
2006-09-19 00:00:00RE-STAMP.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2006-08-25 Cont ID  
Sent By tgordon Date 2006-08-25 Time 11:28 Rev Time 0.30
Received By tgordon Date 2006-08-25 Time 11:37 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2006-09-27 Cont ID  
Sent By astelly Date 2006-09-27 Time 16:26 Rev Time 0.00
Received By astelly Date 2006-09-27 Time 16:25 Sent To  
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2006-07-28 Cont ID  
Sent By astelly Date 2006-07-28 Time 15:14 Rev Time 0.00
Received By astelly Date 2006-07-28 Time 15:14 Sent To  
Notes
***NONE***