Plan Review Stops For Permit 06061595 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2007-02-22 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2007-02-22 |
Time |
16:32 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2007-02-22 |
Time |
16:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-12-13 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-12-13 |
Time |
10:56 |
Rev Time |
1.11 |
Received By |
jwitmer |
Date |
2006-12-13 |
Time |
10:56 |
Sent To |
|
|
Notes |
2006-12-13 11:18:40 | | | BUILDING PLAN REVIEW | | PERMIT: 06061595 | | ADD: 422 SUNSET | | CONT: BURKHARDT CONSTRUCTION | | TEL: (561)718-2602 | | | | | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1STREVIEW | | ACTION: DENIED | | | | PLANS INDICATE THAT EYE-HOOKS ARE TO BE EMBEDDED INTO | | THE CONCRETE POUR WITH STRAPPING OVER THE GENERATOR? | | 106.1.2* ADDITIONAL INFORMATION REQUIRED: | | | | 1A) PLANS ARE TO IDENTIFY THE SIZE OF THE EYE-HOOK | | DIA.X LENGTH. | | 1B) WILL THERE BE A NUT AND WASHER AS PART OF THE | | EMBEDMENT? | | 1C) TYPE OF MATERIAL EYE-HOOK TO BE MADE OF? CARBON | | STEEL, GALVANINIZED? | | 1D) PLACEMENT OF EYE-HOOKS?VERSES STRAPS, PLEASE | | PROVIDE THE PLACEMENT OF BOTH THE BOLT EMBEDMENT AND | | STRAPS SINCE THE STRAPS CAN NOT BLOCK THE DOORS TO THE | | UNIT. | | 1E) PROVIDE ADDITIONAL INFORMATION ON THE TYPE OF | | MATERIAL TO BE USSED FOR THE STRAPS? | | 1F) WITH STRAP TYPE OF HOLD-DOWN AND TYPE OF MATERIAL | | STRAP IS TO BE MADE FROM, HOW MUCH PRESSURE IS TO BE | | REQUIRED TO HOLD THE GENERATOR IN PLACE WITHOUT | | SLIPPAGE OR MOMMENT | | OF OVERTURNING. | | | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | E-MAIL: [email protected] | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2006-07-26 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-07-26 |
Time |
14:20 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-07-26 |
Time |
14:20 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2007-02-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-02-11 |
Time |
12:00 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-02-11 |
Time |
11:47 |
Sent To |
|
|
Notes |
2007-02-11 12:01:08 | ELECTRICAL RISER SHEETS FOR GENERATTOR INSTALL ONLY. | | STAMPED SPECS AND E SHEETS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-12-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-12-06 |
Time |
18:58 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-12-06 |
Time |
18:58 |
Sent To |
|
|
Notes |
2006-12-06 18:59:59 | **** UNSAT 2ND REVIEW *** | | | | | | | | | | 1) NOTE: PLEASE SUBMIT TWO COMPLETE SETS OF PLANS FOR | | REVIEW. PLEASE SEE THE ONE SET SUBMITTED IS NOT | | ACCURATE TO THE LATEST REVISED RISER DIAGRAM FOR | | BUILDING. | | PLEASE KNOW THAT THIS PERMIT SHALL CONTAIN A COMPLETE | | RECORD SET OF PLANS AS THIS IS A STAND ALONE PERMIT. | | SITE PLANS,/SURVEY'S. STRUCTURAL FOUNDATION, ELECTRICAL | | RISER, ETC | | FBC 106.1.2, | | 90.7, 110.3, ETC. | | | | | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-07-15 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-07-15 |
Time |
17:08 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-07-15 |
Time |
16:37 |
Sent To |
|
|
Notes |
2006-07-15 00:00:00 | ****** UNSAT ********* | | | | ** PLEASE SEE NOTES UNDER THE TWO | | PERMITS FOR REMODEL, AS THEY WILL AFFECT | | THIS PERMIT, SERVICE RISER ETC. | | PLEASE SEE SERVICE. | | | | | | 1) NOTE: PLEASE SEE TYPE OF GENERATOR IS | | UNCLEAR AT THIS TIME. PLEASE SEE PERMIT | | APPLICATION HAS A MECHANCICAL CONTRACTOR | | SIGNED ON FOR A "FUEL PERMIT" WHICH | | LENDS TO THIS GEN BEING DIESEL, HOWEVER | | NO INFORMATION ON PLANS. PLEASE SEE NO | | SPECS ARE SUBMITTED FOR FUEL TANK ETC. | | PLEASE SEE PARTIAL "SITE PLAN" MENTIONS | | 400 GAL TANK, BUT DOES NOT SPECIFY TYPE | | OF FUEL. | | PLEASE SEE COMMENTS FROM FIRE AND | | MECHANICAL REVIEW. | | PLEASE SUBMIT SPECS. | | 106.1.2 FBC ADMIN SECT. | | | | 2) NOTE: PLEASE SUBMIT ALL MANUFACTURES | | SPECS/CUT SHEETS FOR THE GEN, ATS'S ETC. | | PLEASE KNOW, ALL SHALL INDICATE LISTINGS | | FROM A NRTL. | | 110.3,702.6 ETC. | | | | 3) NOTE: PLEASE SEE THAT PLANS SPECIFY | | FUEL CONSUMPTION. GPH ETC. | | PLEASE KNOW, AS PERMIT FOR GENERATOR IS | | BEING SUBMITTED UNDER 433 AVON RD, WHICH | | IS A SEPARATE LEGAL PCN ETC AND IF GEN | | IS FEEDING AND LEGALLY REQUIRED STAND-BY | | DEVICES ON 422 SUNSET RD, IT MAY BE | | DETERMINED THAT A UNITY OF TITLE MAY BE | | REQUIRED IF NOT ONE ALREADY. | | THIS WILL REQUIRE FURTHER CONSULTATION. | | | | 4) NOTE: PLEASE CLARIFY IF THE GEN | | ENCLOSURE WILL REMAIN LOCKED, AS ACCESS | | TO SERVICE MEANS OF DISCONNECT SHALL BE | | READILY ACCESSIBLE. | | 100, 230.70 | | | | | | 5) NOTE: PLEASE KNOW, THE NOC SUBMITTED | | WHICH MENTIONS "SITE-WORK" DOES NOT | | COVER THE INSTALLATION OF THE EM GEN | | ETC. | | PLEASE SEE KNOW, THAT A RECORDED NOC | | INCLUDING THE INSTALLATION OF THE GEN | | SHALL BE REQUIRED BEFORE PICKING UP | | PERMIT. | | FS 713.13 | | | | 6) NOTE: PLEASE INDICATE ALL EQUIPMENT | | ON "PARTIAL SITE PLAN" AS CLEARNECE OF | | ALL SERVICE EQUIPMENTNEEDS TO BE | | VERIFIED.110.26 | | | | ** PLEASE KNOW, DUE TO POSSIBLE CHANGES | | IN SERVICE RISER, AND SOME INFORMATION | | NOT SUBMITTED THERE MAY BE COMMENTS ON | | FURTHER REVIEWS WHICH ARE NOT MENTIONED | | ABOVE. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | | | | | | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2007-02-23 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-02-23 |
Time |
18:22 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-02-23 |
Time |
18:22 |
Sent To |
B |
|
Notes |
2007-02-23 18:23:50 | *****APPROVED***** | | | | PLAN SHEET SP-1 STAMPED, INITIALED, AND DATED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2006-08-23 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2006-08-23 |
Time |
11:41 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2006-08-23 |
Time |
09:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2007-01-03 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-01-03 |
Time |
10:23 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-01-03 |
Time |
10:23 |
Sent To |
|
|
Notes |
2007-01-03 10:24:15 | COMMENT RESPONSE - DIESEL GENERATOR - NO LP OR NATURAL | | GAS |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2006-08-08 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2006-08-08 |
Time |
11:11 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2006-08-08 |
Time |
11:11 |
Sent To |
|
|
Notes |
2006-08-08 00:00:00 | DENIED | | REFERENCE: FBC-2004 FUEL GAS | | | | A. MORE INFORMATION IS REQUIRED. | | APPLICATION INDICATES GAS FUEL TANK. | | PLEASE INDICATE TYPE OF FUEL TANK. WILL | | THIS BE AN LP TANK? WILL THIS BE A | | DIESEL TANK?. | | | | B. IF THE TANK IS AN LP TANK, THE | | FOLLOWING INFORMATION IS REQUIRED: | | | | 1. SUBMIT AN ISOMETRIC DRAWING THAT | | CLEARLY SHOWS ALL CUT SECTIONS OF PIPE | | AND CORRESPONDING LENGTHS PER FBC-2004 | | FUEL GAS CODE. | | | | 2. SHOW TYPE OF PIPING MATERIAL BEING | | INSTALLED, ALL PIPE SIZES, (AND THE EDH | | NUMBER OF CORRUGATED STAINLESS STEEL | | TUBING FOR EACH PIPE SIZE IF BEING USED. | | | | 3. NOT USED. | | | | 4. BTU LOAD OF EACH APPLIANCE AND THE | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | 402.4(33). | | | | 5. SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES A.3.1(4). | | | | 6. NOT USED. | | | | 7. INDICATE THE DELIVERY PRESSURE (PSI) | | PER FBC-2004 FUEL GAS CODE SEC. 402.2. | | NATURAL GAS SPECIFY .5 PSI OR 2 PSI. | | | | 8. SUBMIT A DETAIL SHOWING THE TYPE, | | LOCATION, SIZE AND TERMINATION OF THE | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | SECS. 502 THRU 505. | | | | 9. SUBMIT MANUFACTURE SHEETS FOR ALL GAS | | EQUIPMENT TO VERIFY COMPLIANCE WITH | | STANDARDS NFPA 54, NFPA 58, AND THE | | FBC-2004 FUEL GAS CODE SEC 402.2. - | | INSTALLATION SPECIFICATIONS REQUIRED | | WITH MANUF. SHEETS TO VERIFY CLEARANCES. | | | | 10. CLEARLY SHOW THE LOCATION AND CAP- | | ACITY OF LP TANK(S), TYPE OF TANK (DOT | | OR ASME), THE DISTANCE OF THE TANK FROM | | THE BUILDING AND ADJACENT PROPERTY LINES | | THE DISTANCE OF THE TANK FROM ALL SOUR- | | CES OF IGNITION, OTHER CONTAINERS, BUILD | | INGS, AND THE LOCATION OF ANY BUILDING | | OPENINGS BELOW THE RELIEF VALVE OF THE | | TANK PER NFPA 58, TABLE 3-2.2.2. | | | | 11. CLEARLY INDICATE ON THE PLAN IF THE | | LP TANK IS ABOVE OR BELOW GROUND, AND | | SHOW REQUIRED PROTECTION OF THE TANK AND | | APPURTENANCES PER NFPA 58. IF THE TANK | | IS BELOW GROUND THE CONTAINER SHALL BE | | SECURILY ANCHORED PER NFPA 58 SECTION | | 3-2.2.7(H). | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-01-29 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-29 |
Time |
18:53 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-29 |
Time |
18:53 |
Sent To |
E |
|
Notes |
2007-02-07 08:51:23 | TO "COMM" BD#63 | 2007-01-29 18:54:13 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2007-01-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-01-20 |
Time |
12:23 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-01-20 |
Time |
12:23 |
Sent To |
Z |
|
Notes |
2007-01-20 12:24:10 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-11-21 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-11-21 |
Time |
15:48 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-11-21 |
Time |
15:48 |
Sent To |
|
|
Notes |
2006-12-05 13:34:21 | TO "COMM" BD#7 | 2006-11-21 15:49:37 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-08-25 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-08-25 |
Time |
09:20 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2006-06-29 |
Time |
14:16 |
Sent To |
|
|
Notes |
2006-07-13 00:00:00 | TO "COMM" BD#7 | 2006-06-29 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2007-02-16 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-02-16 |
Time |
11:30 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2007-02-16 |
Time |
11:30 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2006-12-12 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-12-12 |
Time |
13:43 |
Rev Time |
0.20 |
Received By |
tgordon |
Date |
2006-12-12 |
Time |
13:43 |
Sent To |
|
|
Notes |
2006-12-12 13:46:07 | *** DENIED *** | | 1) SEE ELECTRICAL REVIEW NOTES REGARDING PLANS NEEDED, | | PLEASE COMPLY. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. | | |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-08-25 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-08-25 |
Time |
09:11 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2006-08-25 |
Time |
09:11 |
Sent To |
|
|
Notes |
2006-08-25 00:00:00 | *** DENIED *** | | 1) PLEASE SEE ELECTRICAL REVIEW NOTES | | AND CORRECT. | | 2) PLEASE SEE THE FOLLOWING NOTES | | REGARDING GENERATOR LOCATION. | | 3) PER 2004 FBC, FUEL GAS - POWERED | | EQUIPMENT - PERMANENTLY INSTALLED | | EQUIPMENT POWERED BY INTERNAL COMBUSTION | | ENGINES SHALL BE INSTALLED IN ACCORDANCE | | WITH MANUFACTURE'S INSTALLATION | | INSTRUCTIONS AND NFPA 37. | | | | NFPA 37 INSTALLATION & USE OF STATIONARY | | COMBUSTION ENGINES & GAS TURBINES: | | 4.1.4ENGINES (GENERATORS) LOCATED | | OUTDOORS SHALL BE MINIMUM OF 5 FT FROM | | OPENINGS IN WALLS & AT LEAST 5 FT FROM | | STRUCTURES HAVING COMBUSTIBLE WALLS.A | | MINIMUM CLEARANCE IS NOT REQUIRED WHEN | | (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | RESISTANCE RATING OF 1 HOUR OR (2) THE | | WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF | | NON-COMBUSTIBLE MATERIALS, AND IT HAS | | BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | MATERIALS OUTSIDE THE ENCLOSURE. | | INFORMATIVE: A.8.2.3.1EXHAUST SYSTEMS | | SHOULD NOT TERMINATE UNDER STRUCTURES OR | | WHERE THE EXHAUST MIGHT BE DRAWN INTO | | THE VENTILATION INTAKES. | | | | 2004 FMC 804.3.5 #3, WHERE THE | | TERMINATION IS LOCATED BELOW AN ADJACENT | | ROOF STRUCTURE, THE TERMINATION POINT | | SHALL BE LOCATED AT LEAST 3 FT FROM THE | | ROOF STRUCTURE. | | | | PLEASE NOTE, WHILE ZONING ALLOWS | | MECHANICAL EQUIPMENT TO ENCROACH 4 FT | | INTO THE REQUIRED SETBACK, GENERATORS | | SHALL MAINTAIN THE REQUIRED ABOVE | | MENTIONED CLEARANCES TO THE ADJACENT | | PROPERTY STRUCTURES, I.E. FENCE, | | BUILDING, WINDOWS, DOORS, OR OPENINGS. | | | | FOLLOW MANUFACTURE'S RECOMMENDED | | CLEARANCES AROUND EQUIPMENT FOR | | SERVICING,AND PROVIDE MANUFACTURE'S | | INSTALLATION INSTRUCTIONS AT THE JOBSITE | | FOR THE FIELD INSPECTOR. | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. | | |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2007-01-25 |
|
|
Cont ID |
|
Sent By |
lfranco |
Date |
2007-01-25 |
Time |
16:58 |
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2007-01-25 |
Time |
16:57 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2007-01-09 |
|
|
Cont ID |
|
Sent By |
jbabcock |
Date |
2007-01-09 |
Time |
09:50 |
Rev Time |
|
Received By |
lfranco |
Date |
2007-01-09 |
Time |
09:12 |
Sent To |
I |
|
Notes |
2007-01-09 09:13:09 | PLANNING AND ZONING:FAILED | | | | 1.PROVIDE ALL COMMENTS IN WRITING. | | | | 2.PURSUANT TO SECTION 94-444(B)-APPROPRIATE SCREENING | | IS REQUIRED.THEREFORE, THE WALLS SHALL BE LANDSCAPED | | WITH SHRUBS AND HEDGES PLANTED AT TWO-FOOT INTERVALS. | | MAKE SURE THAT THE SPACE IS PROVIDED TO ACCOMODATE | | REQUIRED LANDSCAPING AND DOES NOT ENCROACH ON THE | | EXISTING PARKING ADJACENT TO THE PROPOSED GENERATOR. | | | | *NOTATION SHALL BE MADE TO SHOW THAT THE HEDGES WILL BE | | PLANTED AT TWO-FOOT INTERVALS | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT ME AT THE NUMBER BELOW. | | | | JULIA BABCOCK | | PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1435 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
lfranco |
Date |
2006-08-03 |
Time |
11:30 |
Sent To |
|
|
Notes |
2006-08-03 00:00:00 | PLANNING AND ZONING:FAILED | | | | 1.PROVIDE ALL COMMENTS IN WRITING. | | | | 2.PURSUANT TO SECTION | | 94-444(B)-APPROPRIATE SCREENING IS | | REQUIRED.THIS INCLUDES THE WALLS | | SHALL BE LANDSCAPED WITH SHRUBS AND | | HEDGES PLANTED AT TWO-FOOT INTERVALS. | | MAKE SURE THAT THE SPACE IS PROVIDED TO ACCOMMODATE | | REQUIRED LANDSCAPING AND DOES | | NOT ENCROACH ON THE EXISTING PARKING | | ADJACENT TO THE PROPOSED GENERATOR. | | | | IF YOU HAVE ANY QUESTIONS, PLEASE | | CONTACT ME AT THE NUMBER BELOW. | | | | LINDA MIA FRANCO | | SENIOR PLANNER | | PLANNING AND ZONING DEPARTMENT | | TEL: (561) 822-1435 |
|
|