Plan Review Details - Permit 06061556
Plan Review Stops For Permit 06061556
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-07-31 Cont ID  
Sent By amorse Date 2007-07-31 Time 17:48 Rev Time 0.00
Received By amorse Date 2007-07-31 Time 17:48 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-07-10 Cont ID  
Sent By amorse Date 2006-07-10 Time 16:34 Rev Time 0.00
Received By amorse Date 2006-07-10 Time 16:34 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status P Date 2007-09-06 Cont ID  
Sent By dpalmer Date 2007-09-06 Time 08:43 Rev Time 0.00
Received By dpalmer Date 2007-09-06 Time 08:16 Sent To PC
Notes
2007-09-06 08:43:29REVISED PLANS.
  
 SPACING FOR KITCHEN COUNTER SPACE DOES NOT APPEAR TO
 MEET 210.52C1, THIS IS TO BE VIF.
 NEW ENGINEER OF RECORD. LTRS SUBMITTED.

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-12-30 Cont ID  
Sent By dpalmer Date 2006-12-30 Time 14:47 Rev Time 0.00
Received By dpalmer Date 2006-12-30 Time 14:44 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-12-03 Cont ID  
Sent By dpalmer Date 2006-12-03 Time 16:05 Rev Time 0.00
Received By dpalmer Date 2006-12-03 Time 16:01 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-07-06 Cont ID  
Sent By dpalmer Date 2006-07-06 Time 18:45 Rev Time 0.00
Received By dpalmer Date 2006-07-06 Time 18:45 Sent To  
Notes
2006-07-06 00:00:00** REDLINED PLANS, AS RISER SHOWS 125A
 PANEL AND PANEL SCHEDULE IS SHOWN AS
 200A?
 MAIN BUILDING PLANS, INDICATE THESE WILL
 BE CHNAGED FROM THE EXISTING 100A'S TO
 125A PANELS ON THE MAIN BUILDING PERMIT
 APPLICATION TO UPGRADE SERVICE(S).
  
 ** THIS IS TO BE REVISED BEFORE ROUGH.
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2006-07-07 Cont ID  
Sent By mwennerg Date 2006-07-07 Time 11:01 Rev Time 0.00
Received By mwennerg Date 2006-07-07 Time 11:01 Sent To  
Notes
2006-07-07 00:00:00*APPROVED***
  
 NOTE REGARDING ATTACHED FIRE SPRINKLER
 DRAWINGS MAY NOT BE APPLICABLE UNLESS
 WORK INVOLVES COMMON AREA CORRIDOR.

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-08-30 Cont ID  
Sent By adarroug Date 2007-08-30 Time 09:43 Rev Time 0.00
Received By adarroug Date 2007-08-30 Time 09:43 Sent To E
Notes
2007-08-30 09:43:26TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-07-28 Cont ID  
Sent By adarroug Date 2007-07-28 Time 16:38 Rev Time 0.00
Received By adarroug Date 2007-07-28 Time 16:38 Sent To B
Notes
2007-07-28 16:39:06TO "AMORSE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-12-26 Cont ID  
Sent By adarroug Date 2006-12-26 Time 11:20 Rev Time 0.00
Received By adarroug Date 2006-12-26 Time 11:20 Sent To E
Notes
2006-12-26 11:20:29TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-11-16 Cont ID  
Sent By adarroug Date 2006-11-16 Time 16:54 Rev Time 0.00
Received By adarroug Date 2006-11-16 Time 16:54 Sent To E
Notes
2006-11-16 16:55:01TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-07-10 Time   Rev Time 0.00
Received By adarroug Date 2006-06-28 Time 16:10 Sent To  
Notes
2006-06-28 00:00:00TO "BOB"#15

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***