Plan Review Stops For Permit 06061550 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2007-08-18 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-08-18 |
Time |
07:23 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-08-18 |
Time |
07:23 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2006-07-10 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2006-07-10 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2006-07-10 |
Time |
14:24 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2007-08-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-08-12 |
Time |
15:54 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-08-12 |
Time |
15:54 |
Sent To |
PC |
|
Notes |
2007-08-12 15:54:43 | REVISED ELECTRICAL PLANS | | REVISED ENG OF RECORD. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2007-08-02 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-08-02 |
Time |
07:59 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-08-02 |
Time |
07:49 |
Sent To |
PC |
|
Notes |
2007-08-02 08:00:23 | ** UNSAT ** | | | | | | 1) NOTE: PLEASE SEE PLANS ONLY INDICATE ONE SMALL | | APPLIANCE CIRCUIT WHEN LOAD CALCULATIONS INDICATE TWO. | | PLEASE ADJUST LOAD CALCULATIONS. | | 210.52B1, 210.11C1, 220.16 | | | | ** PLEASE BE SURE TO SUBMIT LETTERS BACK WITH REVISED | | PLANS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-12-30 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-12-30 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-12-30 |
Time |
14:05 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-12-03 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-12-03 |
Time |
16:48 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-12-03 |
Time |
16:43 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2006-07-06 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-07-06 |
Time |
16:24 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-07-06 |
Time |
16:24 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2006-07-07 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-07-07 |
Time |
10:44 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-07-07 |
Time |
10:44 |
Sent To |
|
|
Notes |
2006-07-07 00:00:00 | *APPROVED*** | | | | NOTE REGARDING ATTACHED FIRE SPRINKLER | | DRAWINGS MAY NOT BE APPLICABLE UNLESS | | WORK INVOLVES COMMON AREA CORRIDOR. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-08-07 |
|
|
Cont ID |
|
Sent By |
mmiller |
Date |
2007-08-07 |
Time |
17:28 |
Rev Time |
0.00 |
Received By |
mmiller |
Date |
2007-08-07 |
Time |
17:28 |
Sent To |
B |
|
Notes |
2007-08-07 17:28:52 | SENT TO "AM" DESK |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2007-07-28 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-28 |
Time |
16:09 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-28 |
Time |
16:09 |
Sent To |
E |
|
Notes |
2007-07-28 16:10:00 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-12-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-12-26 |
Time |
09:59 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-12-26 |
Time |
09:59 |
Sent To |
E |
|
Notes |
2006-12-26 10:01:32 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-11-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-11-16 |
Time |
16:33 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-11-16 |
Time |
16:33 |
Sent To |
E |
|
Notes |
2006-11-16 16:33:23 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2006-07-10 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-28 |
Time |
16:16 |
Sent To |
|
|
Notes |
2006-06-28 00:00:00 | TO "BOB"#15 |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|