Plan Review Details - Permit 06061301
Plan Review Stops For Permit 06061301
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-08-03 Cont ID  
Sent By rnuquist Date 2006-08-03 Time 19:29 Rev Time 0.00
Received By rnuquist Date 2006-08-03 Time 19:28 Sent To  
Notes
2006-07-28 00:00:00NEW SHEETS

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-07-11 Cont ID  
Sent By rnuquist Date 2006-07-11 Time 22:28 Rev Time 0.00
Received By rnuquist Date 2006-07-11 Time 22:27 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-07-28 Cont ID  
Sent By dpalmer Date 2006-07-28 Time 09:54 Rev Time 0.00
Received By dpalmer Date 2006-07-28 Time 08:59 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-06-28 Cont ID  
Sent By dpalmer Date 2006-06-28 Time 08:51 Rev Time 0.00
Received By dpalmer Date 2006-06-28 Time 07:43 Sent To P
Notes
2006-06-28 00:00:00**** UNSAT ****
  
 1) NOTE: PLEASE PROVIDE LOAD ON EXISTING
 SERVICE W/ NEW LOAD ADDED. PLEASE SEE
 THAT ALL CONTINOUS LOADS BE SHOWN AT
 125%, SHOWN FOR LT AND PUMP, HOWEVER
 THISIS ALSO REQUIRED FOR HEAT PUMP.
 215.3,230.42,430.32,680.9,220.31, 215.5
  
 2) NOTE: PLEASE SEE NEW 1-1/2 HP PUMP IS
 SHOWN WITH THREE #8'S ON PLANS AND ON
 "PANEL SCHEDULE" PROVIDED BY THE
 ELECTRICAN. PLEASE SEE THE MAX OPC FOR
 1/2 HP PUMP SHALL BE SIZED FROM NEC
 430.31,32,430.148
 PLEASE ALSO SEE 3-#8'S WILL NOT FIT INTO
 THIS PUMP, OR RATED FOR CONNECTION TO
 30A OR 20A BRKR.
 PLEASE REVISE AND ADJUST CONDUCTOR SIZES
 ON PLANS AND SHEET ATTACHED TO PLANS.
  
 3) NOTE: PLEASE SEE MISSING EQUIPMENT
 GROUNDING CONDUCTOR FROM EXISTING
 SERVICE TO NEW SUB/POOL PANEL.
 PLEASE SEE 3-#6'S AND 1-#10 IS BEING
 SHOWN IN A 3/4 INCH CONDUIT, YET THIS
 CONDUIT IS OVER FILLED BASED ON TABLES
 FOR CONDUIT FILL IN CHAPTER 9
 250.110,250.122,680.6, 680.25B
  
 *** IMPORTANT**
 4) NOTE: PLEASE SEE ZONING NOTES, AND
 PLEASE SEE THAT IT IS KNOWN BY THIS
 OFFICE THAT THE EXISTING ELECTRICAL
 METER IS BEING MOVED, HOWEVER THE
 EXISTING ELECTRICAL SERVICE PANEL IS
 REMAINING WHERE IT IS AND DOES NOT MEET
 MIN CLEARENCE REQUIREMENTS PER NEC. 680.
 PLEASE KNOW, THE EXISTING ELECTRICAL
 PANEL MUST BE MOVED.
  
 ** PLEASE KNOW, EACH PLAN, PANEL
 SCHEDULE ETC SHALL BE SPECIFIC IN DESIGN
 TO EACH DWELLING/LOCATION AND POOL BEING
 DESIGNED.
 106.1.1,1.6.1.2
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-07-27 Cont ID  
Sent By adarroug Date 2006-07-27 Time 18:00 Rev Time 0.00
Received By rnuquist Date 2006-07-27 Time 18:00 Sent To E
Notes
2006-07-27 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-07-21 Cont ID  
Sent By adarroug Date 2006-07-21 Time 11:35 Rev Time 0.00
Received By adarroug Date 2006-07-21 Time 11:35 Sent To Z
Notes
2006-07-21 00:00:00TO "Z" BOX/RESUB--NEW SHEETS

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-06-27 Cont ID  
Sent By adarroug Date 2006-06-27 Time 11:22 Rev Time 0.00
Received By adarroug Date 2006-06-27 Time 11:22 Sent To E
Notes
2006-06-27 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-07-11 Cont ID  
Sent By adarroug Date 2006-07-11 Time 11:33 Rev Time 0.00
Received By adarroug Date 2006-06-23 Time 11:32 Sent To  
Notes
2006-06-23 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-07-28 Cont ID  
Sent By mperson Date 2006-07-28 Time 15:57 Rev Time 0.33
Received By mperson Date 2006-07-28 Time 15:57 Sent To B
Notes
2006-07-28 00:00:00NEW SHEETS

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-06-30 Cont ID  
Sent By mperson Date 2006-06-30 Time 13:31 Rev Time 0.33
Received By mperson Date 2006-06-30 Time 13:31 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2006-07-23 Cont ID  
Sent By mmclean Date 2006-07-23 Time 15:01 Rev Time 0.00
Received By mmclean Date 2006-07-23 Time 15:01 Sent To I
Notes
2006-07-23 00:00:00NOTE: MUST MAINTAIN THE 20FT VISIBILITY
 TRIANGLE (NO OBSCURED OF THE TRIANGLE)
 DOUBLE FRONTAGE LOT/CORNER LOT.

Review Stop Z ZONING
Rev No 1 Status F Date 2006-06-25 Cont ID  
Sent By mmclean Date 2006-06-25 Time 15:43 Rev Time 0.00
Received By mmclean Date 2006-06-25 Time 15:43 Sent To I
Notes
2006-06-25 00:00:00DENIED,
 1. THE PROPOSED DECK WILL BE TOO MUCH
 CONCRETE WITHIN THE FRONT PROPERTY. (SEC
 94-482 A) (DOUBLE FRONTAGE 31ST CT &
 32ND ST).
 MUST MAINTAIN 1000SQ OR 75% WHICHEVER IS
 LESS FOR LANDSCAPE WTHIN THE 25FT FRONT
 SETBACK.
 2. MUST PROVIDE THE FRONT SETBACK FOR
 THE PROPOSED POOL ON 32ND STREET
 (DISTANCE FROM THE FRONT PROPERTY LINE).
 3. THE PROPOSED POOL MUST SIT BEYOND THE
 25FT FRONT SETBACK.
  
 NOTE: MUST MAINTAIN THE 20FT VISIBILITY
 TRIANGLE (NO OBSCURED OF THE TRIANGLE)
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720