Plan Review Stops For Permit 06061300 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2006-08-03 |
|
|
Cont ID |
|
Sent By |
rnuquist |
Date |
2006-08-03 |
Time |
19:22 |
Rev Time |
0.00 |
Received By |
rnuquist |
Date |
2006-08-03 |
Time |
19:22 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2006-07-11 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-07-11 |
Time |
22:25 |
Rev Time |
0.00 |
Received By |
rnuquist |
Date |
2006-07-11 |
Time |
22:25 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-07-24 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-07-24 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-07-24 |
Time |
13:59 |
Sent To |
P |
|
Notes |
2006-07-24 00:00:00 | REDLINED MISSING EQUIPMENT GROUNDING | | 250.110,250.122 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-06-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-06-28 |
Time |
07:36 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-06-28 |
Time |
07:25 |
Sent To |
P |
|
Notes |
2006-06-28 00:00:00 | **** UNSAT **** | | | | 1) NOTE: PLEASE PROVIDE LOAD ON EXISTING | | SERVICE W/ NEW LOAD ADDED. | | 220.31, 215.5 | | | | 2) NOTE: PLEASE SEE NEW 1/2 HP PUMP IS | | SHOWN WITH THREE #8'S ON PLANS AND ON | | "PANEL SCHEDULE" PROVIDED BY THE | | ELECTRICAN. PLEASE SEE THE MAX OPC FOR | | 1/2 HP PUMP SHALL BE SIZED FROM NEC | | 430.31,32,430.148 | | PLEASE ALSO SEE 3-#8'S WILL NOT FIT INTO | | THIS PUMP, OR RATED FOR CONNECTION TO | | 30A OR 20A BRKR. | | PLEASE REVISE AND ADJUST CONDUCTOR SIZES | | ON PLANS AND SHEET ATTACHED TO PLANS. | | | | 3) NOTE: PLEASE SEE MISSING EQUIPMENT | | GROUNDING CONDUCTOR FROM EXISTING | | SERVICE TO NEW SUB/POOL PANEL. | | 250.110,250.122,680.6, 680.25B | | | | ** PLEASE KNOW, EACH PLAN, PANEL | | SCHEDULE ETC SHALL BE SPECIFIC IN DESIGN | | TO EACH DWELLING/LOCATION AND POOL BEING | | DESIGNED. | | 106.1.1,1.6.1.2 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
N |
Date |
2006-07-26 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-07-26 |
Time |
10:06 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2006-07-26 |
Time |
10:06 |
Sent To |
B |
|
Notes |
2006-07-26 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | BEFORE FINAL POOL INSPECTION. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2006-06-30 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-06-30 |
Time |
11:52 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2006-06-30 |
Time |
11:51 |
Sent To |
B |
|
Notes |
2006-06-30 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | BEFORE FINAL POOL INSPECTION. |
|
|
Review Stop |
HIST |
HISTORICAL |
Rev No |
1 |
Status |
P |
Date |
2006-06-22 |
|
|
Cont ID |
|
Sent By |
ptjomsto |
Date |
2006-06-22 |
Time |
14:01 |
Rev Time |
0.00 |
Received By |
ptjomsto |
Date |
2006-06-22 |
Time |
14:01 |
Sent To |
|
|
Notes |
2006-06-22 00:00:00 | HISTORIC APPROVED 6/22/06 BY JUDGE |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-07-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-24 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-24 |
Time |
10:41 |
Sent To |
E |
|
Notes |
2006-07-24 00:00:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-06-27 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-06-28 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-27 |
Time |
11:11 |
Sent To |
E |
|
Notes |
2006-06-27 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-07-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-11 |
Time |
10:41 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-23 |
Time |
10:26 |
Sent To |
|
|
Notes |
2006-06-23 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2006-07-26 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-07-26 |
Time |
10:03 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-07-26 |
Time |
10:02 |
Sent To |
G |
|
Notes |
2006-07-26 00:00:00 | NEW SHEETS: | | | | ******PROVISO****** | | FBC-2004 SEC. 424.2.9, OR FBCR-2004 SEC. | | R4101.9 WATER SUPPLY, LOCAL ORD. | | #2853-95, BACKFLOW REQUIRED ON WATER | | SERVICE.(ADD TO NOTES) | 2006-07-24 00:00:00 | NEW SHEETS |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
P |
Date |
2006-06-30 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-06-30 |
Time |
11:51 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-06-30 |
Time |
11:51 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2006-06-28 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-06-25 |
Time |
09:28 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-06-25 |
Time |
09:27 |
Sent To |
I |
|
Notes |
|
|