Plan Review Details - Permit 06061247
Plan Review Stops For Permit 06061247
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-07-11 Cont ID  
Sent By rnuquist Date 2006-07-11 Time 22:05 Rev Time 0.00
Received By rnuquist Date 2006-07-11 Time 22:05 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-08-07 Cont ID  
Sent By dpalmer Date 2006-08-07 Time 19:38 Rev Time 0.00
Received By dpalmer Date 2006-08-07 Time 19:23 Sent To PC
Notes
2006-08-07 00:00:00REDLINED PLANS.
  
 REMOVED THE ELEC HEATER AND MADE IT GAS
 W/ FEED FOR IGNITOR.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-06-28 Cont ID  
Sent By dpalmer Date 2006-06-28 Time 11:23 Rev Time 0.00
Received By dpalmer Date 2006-06-28 Time 11:23 Sent To P
Notes
2006-06-28 00:00:00*** UNSAT ***
  
 1) NOTE: PLEASE PROVIDE OCP FEED FROM
 EXISTING SERVICE ALONG WITH THE NEW
 LOADS ADDED TO THE EXISTING LAODS.
 PLEASE ALSO INDICATE THE SIZE OF THE
 EXISTING SERVICE.
 215.5,220.31
  
 2) NOTE: PLEASE SEE ELECTRICAL RISER
 SHOWS AN ELECTRIC HEATER AS OPT, PLEASE
 KNOW PACKAGE AND PLANS NEED TO INDICATE
 OF THE HEATER IS GOING TO BE INSTALLED
 AND IF IT GAS THEN THE ELECTRICAL RISER
 WOULD NOT SHOW OPT HEAT PUMP.
  
 ** PLEASE KNOW, EACH DWELLING/SITE/POOL
 LOCATION SHALL BE SHOWN AS DESIGNED SITE
 SPECIFIC IN THE ELECTRICAL DESIGN, JUST
 AS THE BUILDING/STRUCTURAL PLANS ARE.
 FBC 106.1.1,106.1.2
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE TO CALL.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 CITY OF WEST PALM BEACH
 CONSTUCTION SERVICES DEPT.
 561-805-6717
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2006-06-30 Cont ID  
Sent By mperson Date 2006-06-30 Time 11:08 Rev Time 0.00
Received By mperson Date 2006-06-30 Time 11:08 Sent To B
Notes
2006-06-30 00:00:00NOTE: GAS PERMIT REQUIRED. GAS CONTRAC-
 TOR TO SUBMIT PLANS WITH PERMIT APPLICA-
 TION. ALL GAS INSPECTIONS TO BE COMPLETE
 BEFORE FINAL POOL INSPECTION.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-06-27 Cont ID  
Sent By adarroug Date 2006-06-27 Time 11:27 Rev Time 0.00
Received By adarroug Date 2006-06-27 Time 11:27 Sent To E
Notes
2006-06-27 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-07-11 Cont ID  
Sent By rnuquist Date 2006-07-11 Time 22:06 Rev Time 0.00
Received By rnuquist Date 2006-06-22 Time 13:34 Sent To  
Notes
2006-06-22 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-06-30 Cont ID  
Sent By mperson Date 2006-06-30 Time 11:04 Rev Time 0.33
Received By mperson Date 2006-06-30 Time 11:04 Sent To G
Notes
2006-06-30 00:00:00 
  
  
 ******PROVISO******
 FBC-2004 SEC. 424.2.7.2, OR FBCR-2004
 SEC. R4101.7.2 PUMPS AND EQUIPMENT SHALL
 BE MOUNTED ON A SUBSTANTIAL BASE IN A
 MANNER THAT WILL ELIMINATE STRAIN ON
 PIPING.SLAB SHALL BE A NOMINAL 4"
 THICK.
  
 FBC-2004 SEC. 424.2.14, OR FBCR-2004
 SEC. R4101.15 GAS PIPING SHALL COMPLY
 WITH FBC FUEL GAS.SEPARATE PLANS AND
 PERMIT REQUIRED.

Review Stop Z ZONING
Rev No 1 Status P Date 2006-06-25 Cont ID  
Sent By mmclean Date 2006-06-25 Time 16:34 Rev Time 0.00
Received By mmclean Date 2006-06-25 Time 16:34 Sent To I
Notes
2006-06-25 00:00:00NOTE: THE POOL EQUIPMENT IS NOT LOCATED
 WITHIN ANY SETBACKS.