Plan Review Details - Permit 06060323
Plan Review Stops For Permit 06060323
Review Stop AD ADDRESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2007-07-19 Cont ID  
Sent By amorse Date 2007-07-19 Time 17:43 Rev Time 0.00
Received By amorse Date 2007-07-19 Time 17:43 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-07-11 Cont ID  
Sent By amorse Date 2006-07-11 Time 07:32 Rev Time 0.00
Received By amorse Date 2006-07-11 Time 07:32 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2007-08-02 Cont ID  
Sent By dpalmer Date 2007-08-02 Time 17:21 Rev Time 0.00
Received By dpalmer Date 2007-08-02 Time 14:13 Sent To PC
Notes
2007-08-02 17:22:12REVISED PLANS FOR FINAL.
 REVISED ENGINEER OF RECORD.

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2007-07-23 Cont ID  
Sent By dpalmer Date 2007-07-23 Time 10:26 Rev Time 0.00
Received By dpalmer Date 2007-07-23 Time 10:23 Sent To PC
Notes
2007-07-23 10:27:08*** UNSAT ***
  
  
 1) NOTE: PLEASE SEE THE LOADS AND CIRCUITS FOR ONE OR
 MORE OF THE SMALL APPLIANCE CIRCUITS INCLUDING DINING
 ROOM ARE TO BE SHOWN AND FIGURED AT 1500VA PER
 210.52B1, 210.11C1, 220.16
 PLEASE BE SURE TO ADJUST BOTH THE PANEL SCHEDULE AND
 LOAD CALCULATIONS.
 PLEASE SEE PLANS AND PANEL SCHEDULE INDICATE A 15AMP
 DINING ROOM CIRCUIT. (ALREADY CONTAINS #12 AND NEEDS
 THE ADJUSTMENT OF THE LOADS AND OCP.
  
 2) NOTE: PLEASE SEE NFPA-72, THE SMOKE DEVICES ARE
 SHOWN AS SMOKE DETECTORS, YET THESE SEEM TO BE SMOKE
 ALARMS. PLEASE SEE DEFINITIONS FOR THESE DEVICES UNDER
 NFPA-72.
 PLEASE ADJUST AS PLANS ARE COMING BACK FOR OTHER
 COMMENTS.
  
 3) NOTE: PLEASE BE SURE TO SUBMIT LETTERS WHICH ARE
 ATTACHED TO PLANS WHEN RESUBMITTING.
  
  
 ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR
 COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF
 THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY,
 NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO
 NOT HESITATE IN CONTACTING THIS OFFICE AND THIS
 REVIEWER.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW II
 CONSTRUCTION SERVICES DEPT.
 CITY OF WEST PALM BEACH
 561-805-6717
 [email protected]
  

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-12-30 Cont ID  
Sent By dpalmer Date 2006-12-30 Time 11:25 Rev Time 0.00
Received By dpalmer Date 2006-12-30 Time 11:22 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-12-03 Cont ID  
Sent By dpalmer Date 2006-12-03 Time 14:47 Rev Time 0.00
Received By dpalmer Date 2006-12-03 Time 14:38 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-07-06 Cont ID  
Sent By dpalmer Date 2006-07-06 Time 12:59 Rev Time 0.00
Received By dpalmer Date 2006-07-06 Time 12:58 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status P Date 2006-07-07 Cont ID  
Sent By mwennerg Date 2006-07-07 Time 09:40 Rev Time 0.00
Received By mwennerg Date 2006-07-07 Time 09:40 Sent To  
Notes
2006-07-07 00:00:00*APPROVED***
  
 NOTE REGARDING ATTACHED FIRE SPRINKLER
 DRAWINGS MAY NOT BE APPLICABLE UNLESS
 WORK INVOLVES COMMON AREA CORRIDOR.

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-07-31 Cont ID  
Sent By adarroug Date 2007-07-31 Time 16:26 Rev Time 0.00
Received By adarroug Date 2007-07-31 Time 16:26 Sent To E
Notes
2007-07-31 16:27:02TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2007-07-17 Cont ID  
Sent By adarroug Date 2007-07-17 Time 10:51 Rev Time 0.00
Received By adarroug Date 2007-07-17 Time 10:51 Sent To E
Notes
2007-07-17 10:51:26TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2007-07-17 Cont ID  
Sent By adarroug Date 2007-07-17 Time 10:32 Rev Time 0.00
Received By adarroug Date 2007-07-17 Time 10:32 Sent To B
Notes
2007-07-17 10:32:57TO "AMORSE" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-05-10 Cont ID  
Sent By adarroug Date 2007-05-10 Time 14:41 Rev Time 0.00
Received By adarroug Date 2007-05-10 Time 14:41 Sent To  
Notes
2007-05-22 09:40:48TO "COMM" BD#51
2007-05-10 14:41:50WAITING FOR "COMN" BD-REV

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-12-26 Cont ID  
Sent By adarroug Date 2006-12-26 Time 09:58 Rev Time 0.00
Received By adarroug Date 2006-12-26 Time 09:58 Sent To E
Notes
2006-12-26 09:58:51TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-11-16 Cont ID  
Sent By adarroug Date 2006-11-16 Time 16:32 Rev Time 0.00
Received By adarroug Date 2006-11-16 Time 16:32 Sent To E
Notes
2006-11-16 16:32:45TO "DPALMER" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-06-14 Cont ID  
Sent By adarroug Date 2006-06-14 Time   Rev Time 0.00
Received By adarroug Date 2006-06-14 Time 08:33 Sent To  
Notes
2006-08-22 00:00:00APPLICATION WAS TAKEN OUT BY TONY ON
 6/14/06 AND RETURNED ON 6/27/06 WITH A
 REVISED DESCRIPTION OF WORK
2006-06-28 00:00:00 
  
 TO "BOB"#14

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status N Date   Cont ID  
Sent By   Date   Time   Rev Time 0.00
Received By   Date   Time   Sent To  
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved