Plan Review Stops For Permit 06051212 |
Review Stop |
AD |
ADDRESSING |
Rev No |
1 |
Status |
P |
Date |
2006-10-19 |
|
|
Cont ID |
|
Sent By |
lursu |
Date |
2006-10-19 |
Time |
08:28 |
Rev Time |
0.00 |
Received By |
lursu |
Date |
2006-10-19 |
Time |
08:28 |
Sent To |
PC |
|
Notes |
2006-10-19 08:29:40 | USE EXT #0021 UNDER 777 S FLAGLER DR , PCN = 74 43 43 | | 22 30 001 0060 | 2006-05-30 00:00:00 | EXT REQUIRED FOR #1200 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2006-10-18 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-10-18 |
Time |
10:45 |
Rev Time |
0.00 |
Received By |
jwitmer |
Date |
2006-10-18 |
Time |
10:45 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-09-19 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-09-19 |
Time |
10:47 |
Rev Time |
0.77 |
Received By |
jwitmer |
Date |
2006-09-19 |
Time |
10:47 |
Sent To |
|
|
Notes |
2006-09-19 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 06051212 | | ADD: 777 S FLAGLER# 1200 | | CONT: HEDRICK BROTHERS | | TEL: (561)718-8341 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 2ND REVIEW | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2) ENGINEER CLIFFORD DIAZ: | | STAMPED SEAL PLEASE REVIEW FL | | ADMINISTRATIVE CODE REQUIREMENTS FOR | | SIZE AND EMBOSSING REQUIREMENTS OF SEAL. | | 61G15-23.001 SEALS ACCEPTABLE TO THE | | BOARD. PURSUANT TO SECTION 471.025 F.F., | | THE BOARD HEREBY ESTABLISHES AS | | INDICATED BELOW THE FORMS OF EMBOSSING | | IMPRESSION SEALS WHICH ARE ACCEPTABLE TO | | THE BOARD. SAID SEAL SHALL BE A MINIMUM | | OF 1 7/8" IN DIAMETER. ALL ENGINEERS | | MUST BE UTILIZING A SEAL AS ILLUSTRATED | | IN THIS RULE NO LATER THAN JANUARY | | 1,2006. | | | | 3) ENGINEER CLIFFORD DIAZ: | | 61G15-23.002 SEALS SIGNATURE AND DATE | | SHALL BE AFFIXED. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-06-20 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-06-20 |
Time |
08:24 |
Rev Time |
3.33 |
Received By |
jwitmer |
Date |
2006-06-20 |
Time |
08:24 |
Sent To |
|
|
Notes |
2006-06-20 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 06051212 | | ADD: 777 S FLAGLER# 1200 | | CONT: HEDRICK BROTHERS | | TEL: (561)718-8341 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1ST REVIEW | | ACTION: DENIED | | | | 1)--- VERY IMPORTANT STATEMENT --- | | PLEASE DO NOT IGNORE! | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. A TRANSMITTAL LETTER | | LISTING THE ORIGINAL REVIEW COMMENT NUM- | | BER, WITH A DESCRIPTION OF THE REVISION | | MADE, IDENTIFYING THE SHEET OR SPECIFICA | | TION PAGE WHERE THE CHANGES CAN BE FOUND | | WILL HELP TO EXPEDITE YOUR PERMIT. THANK | | YOU FOR YOUR ANTICIPATED COOPERATION. | | | | 2) SEE ELECTRICAL COMMENTS 2-5 ON | | LICENSING LAWS FL S. S. 471/ 481 FOR | | ENGINGEERS & ARCHITECTS. | | | | 3) SHEET A0.03 | | 3A) PROJECT CODE DATA IS MISSING MINIMUM | | BUILDING TYPE SEE TABLE 503. | | | | 3B) APPLICABLE CODE DATA LIST THE 2004 | | FBC BUT NO MENTION TO THE 2004 FBC | | EXISTING BUILDING CODE PROVIDE WHAT | | LEVEL OF RENOVATION IS TO TAKE PLACE. | | | | 4) SHEET A7.00 DETAILS 7 & 8 BOTH REFER | | TO DETAIL 1/ OF SHEET 9.00 MISSING? | | | | 5) BOTH OF THE DETAILS MENTIONED ABOVE | | INDICATE THE USE OF WOOD PANELS, PROVIDE | | ADDITIONAL INFORMATION. WOOD PANEL | | FINISHES PROVIDE DOCUMENTATION TO BEING | | TESTED TO ASTM E 84 OR NFPA 286. | | 803.1/ 803.2. | | | | 6) DETAIL# 5/ A8.20 INDICATES THE USE OF | | | | 3/4" PANELING WITHOUT SOLID BACKING. | | SEE 803.4.2,803.4.2 SET-OUT | | CONSTRUCTION. | | WHERE WALLS AND CEILINGS ARE REQUIRED TO | | BE OF FIRE-RESISTANCE-RATED OR | | NONCOMBUSTIBLE CONSTRUCTION AND WALLS | | ARE SET OUT OR CEILINGS ARE DROPPED | | DISTANCES GREATER THAN SPECIFIED IN | | SECTION 803.4.1 , CLASS A FINISH | | MATERIALS SHALL BE USED EXCEPT WHERE | | INTERIOR FINISH MATERIALS ARE PROTECTED | | ON BOTH SIDES BY AN AUTOMATIC SPRINKLER | | SYSTEM OR ATTACHED TO NONCOMBUSTIBLE | | BACKING OR FURRING STRIPS INSTALLED AS | | SPECIFIED IN SECTION 803.4.1 . THE | | HANGERS AND ASSEMBLY MEMBERS OF SUCH | | DROPPED CEILINGS THAT ARE BELOW THE MAIN | | CEILING LINE SHALL BE OF NONCOMBUSTIBLE | | MATERIALS, EXCEPT THAT IN TYPE III AND V | | CONSTRUCTION, FIRE-RETARDANT-TREATED | | WOOD SHALL BE PERMITTED. THE | | CONSTRUCTION OF EACH SET-OUT WALL SHALL | | BE OF FIRE-RESISTANCE-RATED CONSTRUCTION | | AS REQUIRED ELSEWHERE IN THIS CODE. | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
P |
Date |
2006-12-31 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-12-31 |
Time |
08:47 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-12-31 |
Time |
08:30 |
Sent To |
PC |
|
Notes |
2006-12-31 08:49:14 | *** REV FOR ADDITION OF UPS SPECS AND OCCUPANCY TYPE | | DEVICES.VALUE INCREASED ALSO TO PRINT NEW CARD | | REV FOR RISER DID NOT COME BACK IN. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
F |
Date |
2006-11-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-11-28 |
Time |
19:16 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-11-28 |
Time |
18:30 |
Sent To |
|
|
Notes |
2006-11-28 19:16:47 | **** UNSAT *** | | | | 1) NOTE: PLEASE SEE MISSING LIGHTING CONTROL OVER RIDE | | DEVICE IN ROOM 1205. | | 13-415.1.ABC.1.2 PLEASE ADJUST ON E-3 | | | | 2) NOTE: PLEASE SEE MISSING ONLY THE CANDELA LEVELS | | REQUIRED PER FBC 2004 11-4.28.1 AND 11-4.28.3(4) IS | | PERMITTED. THIS IS 75 MIN. PLEASE ADJUST NOTE ON E-5 | | | | 3) NOTE: PLEASE SEE COMPLETE UPS BACK UP SYSTEM NOT IN | | SCOPE OR PERMITTED UNDER THIS PERMIT IS NOW BEING SHOWN | | ON PLANS. THE INFORMATION FOR ALL EQUIPMENT AND VALUE | | FOR SCOPE OF WORK WAS PREVIOUSLY REQUESTED ON REVIEWS | | DATING BACK BEFORE PERMITTING AND THE DESIGNER OF | | RECORD REMOVED FROM PROJECT STATING THIS SCOPE OF WORK | | WOULD NOT BE DONE. PLEASE SEE NOW PLANS INDICATE THIS. | | PLEASE SUBMIT ALL THE PREVIOUSLY REQUESTED INFORMATION | | FOR SAID SYSTEM UNDER A SEPARATE PERMIT INCLUDING | | PERMIT APPLICATION, SIGNED DATED AND SEALED PLANS, | | ALONG WITH ALL MANUFACTURES SPEC/CUT SHEETS FOR ALL UPS | | EQUIPMENT. | | PLEASE KNOW THE VALUE FOR THIS SCOPE OF WORK SHALL BE | | BASED ON ALL LABOR AND MATERIALS WHETHER OR NOT | | EQUIPMENT IS OWNER SUPPLIED. PLEASE KNOW, ONCE A PERMIT | | FOR THIS SCOPE OF WORK IS ISSUED, THEN A REVISION | | INCLUDING THIS SCOPE OF WORK ON THE MAIN BUILDING | | PERMIT MAY BE SUBMITTED, HOWEVER NOTING THIS WORK UNDER | | A SEPARATE PERMIT. | | | | ** PLEASE SEE SHEETS E-3- E-5 WHICH WERE STAMPED AND | | WERE BEING REDLINED WERE STAMPED "VOID" UNTIL SCOPE | | ABOVE IS ADDRESSED. | | THIS WORK WAS TAKEN OUT OF THE ORIGINAL PLANS. | | | | FBC 106.1.2, 106.3.5.1.2 | | NEC 110.3, 90.7, 645.11 ETC. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR REVIEW. IF | | THERE ARE ANY QUESTIONS, COMMENTS OR IF ANY PART OF | | NOTES ABOVE ARE NOT UNDERSTOOD OR TYPED IN A MANNER | | WHICH IS NOT CLEAR, PLEASE DO NOT HESITATE IN | | CONTACTING THIS OFFICE OR REVIEWER. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-10-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-10-19 |
Time |
08:59 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-10-18 |
Time |
21:05 |
Sent To |
AD |
|
Notes |
2006-10-19 08:59:52 | ********* PROVSIO ******** | | | | | | 1) NOTE: PLEASE SEE CONFERENCE ROOMS 1201 AND 1203 DO | | NOT SEEM TO CONTAIN OVER-RIDE DEVICES FOR LIGHTING | | CONTROLS. PLEASE SEE LIGHTING RELAY SCHEDULE ALSO DOES | | NOT SEEM TO INDICATE THESE CIRCUITS. | | | | 2) NOTE: PLEASE SEE REDLINE E-5 AS COMMENT FOR MINIMUM | | LEVELS FOR HORN/STROBES IS NOT STAED. THIS HAS NOW | | BECOME PART OF THE ELECTRICAL PLAN REVIEW PROCESS. | | PLEASE SEE FBC 200411-4.28., 11-4.28.2, FOR MIN | | ADUDIBLE LEVELS AND 11-4.28.3(4) FOR MIN LIGHTING | | CANDELA. | | | | ** PLEASE BE SURE TO SHOW THESE AND AND INCLUDE ON | | PLANS. SUBMIT REVISED PLANS ALONG WITH ANY OTHER | | REVISIONS BEFORE ANY ROUGHT ELECTRICLA INSPECTION. | | REVISED STAMPED PLANS MUST BE ON SITE FOR ELECTRICLA | | INSPECTOR. | | | | IF THERE ARE ANY QUESTIONS, PLEASE DO NOT HESITATE IN | | CONTACTING THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PAN REVIEW | | 561-805-6717 | 2006-10-18 21:05:33 | IN ELECTRICAL FOR REVIEW, REVIEW IN PROGRESS |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-08-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-08-20 |
Time |
15:41 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-08-20 |
Time |
15:00 |
Sent To |
|
|
Notes |
2006-08-20 00:00:00 | **** UNSAT 2ND REVIEW ******* | | | | ** PLEASE SEE SOME NOTE FROM PREVIOUS | | REVIEW AND SOME NEW NOTES ARE IN NEED OF | | ADDRESSING. | | | | 1) NOTE: OK, AS SCOPE ON PLANS HAS | | DECREASED. | | | | 2) NOTE: OK. | | | | 3) NOTE: OK. | | | | 4) NOTE: NO, PLEASE SEE THE E-SHEETS | | WERE NOTE DATED WHEN SIGNED BY THE | | ENGINEER. PLEASE MAKE SURE ALL THE NEW | | REVISED SHEETS ARE DATED WHEN SIGNING | | AND SEALING SADI DOCUMENTS. FS 471.025, | | FAC 61G15-23.002. | | | | ** PREVIOUS REVIEW NOTE** | | PLEASE SEE THAT PLANS ARE NOTE DATED BY | | THE ARCHITECT OR ENGINEER AS REQUIRED | | UNDER FS 481.221, 471.025. | | | | 5) NOTE: OK/NO, PLEASE SEE NEW ENERGY | | CALCUALTIONS WERE SUBMITTED HOWEVER | | THESE DO NOT CONTAIN A RAISED SEAL AS | | REQUIRED. PLEASE SEE A "RUBBER STAMP" IS | | PLACE IN LEIU OF THE REQUIRED RAISED | | SEASL. FAC 61G15-23.001 | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SEE CORRECTED ENERGY | | CODE CALCULATIONS SHAL BE DESIGNED UNDER | | FBC 2004. | | PLEASE SEE THEY CURRENTY INDICATE THE | | 2001 ICC. | | PLEASE BE SURE THEY ARE SIGNED , DATED | | AND SEALED BY THE ENGINEER OF RECORD. | | PLEASE SEE FBC CHAPTER 13 13-415.1.AB.1, | | 13-415.2.ABC.1 | | | | 6) NOTE: OK. | | | | 7) NOTE: OK. | | | | 8) NOTE: OK. | | | | 9) NOTE: OK. | | | | 10) NOTE: OK, SEE NEW NOTES. | | | | 11) NOTE: OK. | | | | 12) NOTE: NO, THIS IS UNCLEAR STILL AS | | RISER NOW SHOWS A MAIN AHEAD OF THE FPL | | METER. PLEASE KNOW, PER FPL GUIDLINES | | FOR SERVICES, A MAIN IS REQUIRED ON THE | | LOAD SIDE OF METER. PLEASE KNOW, IF | | INDEED THIS IS INSTALLED AS SHOWN PLEASE | | BE SURE TO INDICATE A "FLOATING | | NEUTRAL". | | PLEASE SEE NEW NOTES FOR LOAD | | CALCUALTIONS. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE CLARIFY RISER, IS THE | | "EXISTING TENANT" BEING SHOWN ON THE | | RISER ANOTHER TENANT SPACE OR IS THIS | | THE EXISTING TENANT RISER FOR THIS | | SPACE? | | AS SHOWN, THERE SEEMS TO BE AN EXISTING | | TENANT AND THIS NEW BUILD OUT IS NOTW | | TAPPING THE EXISTING METER AS SHOWN?? | | THIS IS NOT CLEAR AT THIS TIME. | | 215.5 | | | | 13) NOTE: NO/UNCLEAR SEE NOTE ABOVE. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE PROVIDE EXISTING , OR | | NEW METER SIZE AND WHERE THE | | DISCONNECTING MEANS FOR SERVICE IS | | LOCATED AND THE OCP AND SIZE OF TENANT | | SERVICE DISCONNECT. | | CURRENTLY THIS IS NOT SHOWING ANY MAIN, | | AND A 42 CIRCUIT MLO FOR TENANTS | | DISCONNECTING MEANS. | | 215.5,240.4,310.16,230.70 ETC | | | | 14) NOTE: NO, PLEASE SEE ATTACHMENT ONLY | | BEING NTOED FOR THE 45K UNIT. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE INDICATE TH ACTUAL | | ATTACHMENT FOR THE GROUNDING ELECTRODE | | OF THE NEW SEPARATELY DERIVED | | TRANSFORMERS. | | 250.66, 250.30 | | THE NOTE ON PLANS NEEDS TO BE SHOWN. | | | | 15) NOTE: OK. SEE NEW NOTES. | | | | | | 16) NOTE: OK. | | | | | | ** NEW NOTES** | | | | 17) NOTE: PLEASE SSUBMIT COMPLETE LOAD | | CALCULATIONS FOR THE EXISTING 200A MIAN | | AND METER BEING SHOWN. (LOADS FOR "H", | | "L" AND "CR. | | 220, | | FBC 106.1.2 | | | | 18) NOTE: PLEASE SEE IT ROOM DOES NOT | | INDICATE THE TRANSFORMER ON ROOM LAYOUT? | | PLEASE SEE RISER AND NOTE MENTIONS THIS | | IS A FLR MOUNTED UNIT. | | PLEASE SEE 110.26 | | | | 19) NOTE: PLEASE SEE PANEL "CP" IS BEING | | SHOWN AS 125A RATED AND FED FROM "RP" | | WHICH IS 150A MCB AND FEED-THRU LUGS. | | THEN PANEL "CP" WOULD ALSO BE REQUIRED | | TO BE 150A RATED, OR IF USING A TAPPED | | CONDUCTOR RULE, TERMINATE IN OCP WHICH | | LIMITS THE LOAD. | | 240.21, 408.16, 240.3 | | THIS WAS SHOWN AS THE SAME ON PREVIOUS | | PLANS, HOWEVER WAS NOT COMMENTED ON. | | | | 20) NOTE: PLEASE SEE THE FOLLOWING AS | | THE FIRST COMMENT FROM BUILDING REVIEWER | | REQUESTED ALL OLD/VOIDED SHEETS BE | | REMOVED, YET PLEASE SEE ALL OLD | | ELECTRICAL SHEETS WERE LEFT IN SETS. | | | | ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-06-19 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-06-19 |
Time |
14:40 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-06-19 |
Time |
08:48 |
Sent To |
|
|
Notes |
2006-06-19 00:00:00 | IN ELEC FOR REVIEW. | | ********** UNSAT *********** | | | | 1) NOTE: PLEASE SEE VALUE FOR SCOPE OF | | WORK SHALL INCLUDE ALL MATERIALS AND | | LABOR (EVEN IF ANY EQUIPMENT IS OWNER | | SUPPLIED). | | PLEASE SEE UPGRADE , AND SPECIALLY | | DESIGNED LIGHTING CONTROL SYSTEMS ETC | | SHALL ALOS BE INCLUDED IN VALUE IF SHOWN | | ON PLANS. | | ALL PERMANANTLY INSTALLED SYSTEMS. | | FBC ADMINISTRATIVE SECTION 108.3 AS | | ADOPTED BY THE CITY OF WEST PALM BEACH. | | | | 2) NOTE: PLEASE SEE MISSING INFORMATION | | REQUIRED ON ALL TITLE BLOCKS ON PLANS. | | PLEASE SEE MISSING ARCHITECTURAL FIRM | | CERTIFICATE OF AUTHORIZATION #. | | PLEASE SEE MISSING ENGINEERING FIRM CA#. | | PLEASE SEE MISSING THE PRINTED NAME AND | | PRINTED LICENSE # OF SAID ARCHITECT. | | PLEASE SEE ALL OF THE ABOVE IS REQUIRED | | PER FLORIDA ADMINISTRATIVE CODES | | 61G1-16.004, 61G15-23.002, FLORIDA | | STATUES 481.219, AND FS471.023 | | ** THIS IS REQUIRED OF ALL TRADES AND | | FOR ALL SHEET WHETHER OR NOT COMMENT IS | | MADE BY OTHER REVIEWER(S). | | | | 3) NOTE: PLEASE SEE FLORIDA | | ADMINISTRATIVE CODE 61G15-23.001 WHICH | | PASSED A RULING IN FEB 04 WHICH REQUIRED | | ALL ENGINEER'S SEALS TO CONTAIN THE | | WORDING OF "LICENSE" IN SEAL. PLEASE SEE | | THAT ALL SEALS WITH THE WORDING OF | | "CERTIFICATE" ARE NOT LONGER ACCEPTABLE. | | | | 4) NOTE: PLEASE SEE THAT PLANS ARE NOT | | DATED BY THE ARCHITECT OR ENGINEER AS | | REQUIRED UNDER FS 481.221 AND 471.025 | | | | 5) NOTE: PLEASE SEE CORRECTED ENERGY | | CODE CALCULATIONS SHAL BE DESIGNED UNDER | | FBC 2004. | | PLEASE SEE THEY CURRENTY INDICATE THE | | 2001 ICC. | | PLEASE BE SURE THEY ARE SIGNED , DATED | | AND SEALED BY THE ENGINEER OF RECORD. | | PLEASE SEE FBC CHAPTER 13 13-415.1.AB.1, | | 13-415.2.ABC.1 | | | | 6) NOTE: PLEASE BE SURE PLANS INCLUDIGN | | ELECTRICAL REFLECT THE CURRNT CODE IN | | EFFECT FOR DESIGN. | | PLEASE SEE PLANS SHOULD INCLUDE THE | | FOLLOWING AT A MIN. | | 2002 NFPA-70, (2005 SHOWN), 2003 | | NFPA-101, NFPA-72 2002, NFPA-75 2003. | | | | 7) NOTE: PLEASE CLARIFY LIGHTING | | CONTROLS FOR ALL ROOMS AS SOME COULD NOT | | BE LOCATED FOR THE OVER RIDE DEVICES AS | | REQUIRED. | | FBC 13-415.1.ABC.1.1, .1.2 ETC. | | 1205,1202,1203,1201 | | ** PLEASE SPECIFY TIME LIMITS ON | | DEVICES. CAN BE A "TYPICAL" NOT FOR NO | | MORE THAN 30 MINS FOR OS TYOE DEVICES | | AND 4HRS FOR TIMED TYPE DEVICES. | | ** PLEASE SEE A OSZ2 DEVICE IS SHOWN ON | | PLANS, HOWEVER COULD NOT LOCATED THIS ON | | LEGEND? | | | | 8) NOTE:PLEASE SEE FIRE REVIEW | | COMMENTS AS TYPE OF "ELEC LOCK" FOR | | ACCESS CONTROLS NEED TO BE CLARIFIED. | | PLEASE SEE THAT IN THE EVENT OF POWER | | FAILURE, EGREES SHALL NOT IMPEDED. | | | | 9) NOTE: PLEASE SEE THAT PLANS CLEARLY | | INDICATE THE FLR AND SUITE NUMBER IN | | TITLE BLOCK. | | FAC 61G1-16.004 | | | | 10) NOTE: PLEASE KNOW, AN "ALTERNATE" | | SYSTEM IS BEING SHOWN FOR THE IT ROOM. | | PLEASE KNOW, IF THIS SYSTEM IS BEING | | PROPOSED THEN IT SHOULD BE ON PLANS, IF | | NOT THIS SHOULD BE REMOVED. IF THIS | | SYSTEM IS GOING TO BE INSTALLED, PLEASE | | PROVIDE ALL MANUFACTURES SPCES/CUT | | SHEETS INDICATE A LISTING FROM A NRTL. | | 215.5 | | | | 11) NOTE: PLEASE CLARIFY ROOM BEING | | INDICATE AS AN "IT" ROOM ON PLANS WHICH | | SHALL MEET NFPA-75 AND NEC 645. | | PLEASE CLARIFY IF THERE IS A RAISED | | FLOOR? IF SO, PLEASE INDICATE THE | | REQUIRMENTS/ SD UNDER FLR. | | 8.2 | | | | 12) NOTE: PLEASE CLARIFY RISER, IS THE | | "EXISTING TENANT" BEING SHOWN ON THE | | RISER ANOTHER TENANT SPACE OR IS THIS | | THE EXISTING TENANT RISER FOR THIS | | SPACE? | | AS SHOWN, THERE SEEMS TO BE AN EXISTING | | TENANT AND THIS NEW BUILD OUT IS NOTW | | TAPPING THE EXISTING METER AS SHOWN?? | | THIS IS NOT CLEAR AT THIS TIME. | | 215.5 | | | | 13) NOTE: PLEASE PROVIDE EXISTING , OR | | NEW METER SIZE AND WHERE THE | | DISCONNECTING MEANS FOR SERVICE IS | | LOCATED AND THE OCP AND SIZE OF TENANT | | SERVICE DISCONNECT. | | CURRENTLY THIS IS NOT SHOWING ANY MAIN, | | AND A 42 CIRCUIT MLO FOR TENANTS | | DISCONNECTING MEANS. | | 215.5,240.4,310.16,230.70 ETC | | | | 14) NOTE: PLEASE INDICATE TH ACTUAL | | ATTACHMENT FOR THE GROUNDING ELECTRODE | | OF THE NEW SEPARATELY DERIVED | | TRANSFORMERS. | | 250.66, 250.30 | | THE NOTE ON PLANS NEEDS TO BE SHOWN. | | | | 15) NOTE: PLEASE SEE MININUM CLEARENCES | | FOR TRANSFORMER AND PANELS DO NOT MEET | | 110.26, 450.13,450.9 ETC | | PLEASE SEE PLANS MENTIONS THESE TO BE | | FLR MOUNTED WHICH WOULD PLACE THEM | | DIRECTLY INFRONT OF PANEL(S). | | | | 16) NOTE: PLEASE VERIFY LOAD | | CALCULATIONS WHICH SHOULD INDICATE ALL | | CONTINOUS LOADS AT 125%. | | PLEASE SEE THE DEMAND IS SHOWN AS 1.25 | | ON PANELS, BUT NOT ON MAIN PANEL AND THE | | CONTINUOUS LOADS DO NOT NOT SEEM TO HAVE | | BEEN CARRIED OVER. | | 215.3,230.42 | | | | ** PLEASE BE SURE TO SEE ANY COMMENTS | | FROM OTHER TRADES WHICH MAY AFFECT | | ELECTRICAL PLANS AND DESIGN. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
3 |
Status |
P |
Date |
2007-01-08 |
|
|
Cont ID |
|
Sent By |
mawillia |
Date |
2007-01-08 |
Time |
17:20 |
Rev Time |
0.00 |
Received By |
mawillia |
Date |
2007-01-08 |
Time |
17:20 |
Sent To |
|
|
Notes |
2007-01-08 17:29:22 | *****APPROVED***** | | | | | | | | REVISED SPRINKLER PLAN (SP-1) SHEET STAMPED, SIGNED, | | AND DATED.FIRE ALARM/LIFE SAFETY PLAN (E-5) SHEET TO | | BE DONE UPON ELECTRICAL PLAN REVIEW COMMENT HAS BEEN | | SATISFIED. |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2006-09-28 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-09-28 |
Time |
10:30 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-09-28 |
Time |
10:30 |
Sent To |
|
|
Notes |
2006-09-28 00:00:00 | ***PROVISO*** | | | | PLANS HAVE BEEN APPROVED BUT NOT STAMPED | | UNTIL OTHER FS AND FAC REQUIREMENTS ARE | | MET. PREVIOUS FIRE REVIEW HAS BEEN | | ADDRESSED. | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2006-06-22 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-06-22 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-06-22 |
Time |
15:23 |
Sent To |
|
|
Notes |
2006-06-22 00:00:00 | ***DENIED*** | | | | 1) PLEASE SEE ELECTRICAL REVIEW COMMENTS | | REGARDING FAC REQUIREMENTS FOR TITLE | | BLOCKS. | | | | 2) SEPARATE SHOP DRAWINGS AND PERMITS | | ARE REQUIRED FOR FIRE SPRINKLER AND FIRE | | ALARM REMODEL. PLEASE NOTE THAT THE WORD | | CHANGE FROM 'CERTIFICATE' TO 'LICENSE' | | IS REQUIRED FOR ANY SEALED DRAWINGS | | SUBMITTED FOR THESE SYSTEMS. | | | | 3) FOR SPRINKLER REMODEL, NFPA 13, 2002 | | EDITION SHALL BE REFERENCED. | | | | 4) CONSTRUCTION, ALTERATION AND | | DEMOLITION SHALL COMPLY WITH NFPA 241. | | | | 5) PLANS ILLUSTRATE ELECTRIC LOCKS AND | | CARD READERS. WHAT IMPACT WILL THIS | | ARRANGEMENT HAVE ON REQUIRED EXITING? | | DOORS SHALL COMPLY WITH NFPA 101, 2003 | | EDITION SEC. 7.2.1.5. | | | | 6) 2A-10B,C RATED FIRE EXTINGUISHERS | | SHALL BE MOUNTED AT DISTANCES NOT TO | | EXCEED 75' TRAVEL DISTANCE REQUIREMENT. | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-12-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-12-27 |
Time |
11:57 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-12-27 |
Time |
11:57 |
Sent To |
E |
|
Notes |
2006-12-27 11:57:25 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-11-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-11-16 |
Time |
08:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-11-16 |
Time |
08:54 |
Sent To |
|
|
Notes |
2006-11-27 16:39:08 | TO "COMM" BD#13 | 2006-11-16 08:55:11 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-10-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-05 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-05 |
Time |
15:46 |
Sent To |
|
|
Notes |
2006-10-18 08:40:12 | TO "BOB"#3 | 2006-10-05 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-08-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-16 |
Time |
13:15 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-16 |
Time |
13:15 |
Sent To |
|
|
Notes |
2006-08-17 00:00:00 | TO "COMM" BD#59 | 2006-08-16 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-08-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-19 |
Time |
13:14 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-30 |
Time |
15:02 |
Sent To |
|
|
Notes |
2006-06-15 00:00:00 | TO "COMM" BD#48 | 2006-06-01 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
4 |
Status |
P |
Date |
2006-11-28 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-11-28 |
Time |
14:25 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2006-11-28 |
Time |
14:25 |
Sent To |
|
|
Notes |
2006-11-28 14:26:58 | REVISION TO MECH. PLANS PAGE M-1, M-2, M-3. AND M-4. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2006-10-18 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-10-18 |
Time |
12:32 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2006-10-18 |
Time |
12:32 |
Sent To |
|
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2006-08-17 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-08-17 |
Time |
16:30 |
Rev Time |
0.40 |
Received By |
tgordon |
Date |
2006-08-17 |
Time |
16:30 |
Sent To |
|
|
Notes |
2006-08-17 00:00:00 | *** DENIED *** | | 1) THE ENGINEER CLIFFORD DIAS MUST SHOW | | THE DATE HE SIGNED AND SEALED THE PLANS, | | PER FAC 61G15-23.002 . | | | | 2) SEE PAGE M-4 A/C UNIT SCHEDULE, NEED | | TO SHOW THE SEER OF THE A/C SYSTEMS. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-07-19 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-07-19 |
Time |
08:30 |
Rev Time |
0.35 |
Received By |
tgordon |
Date |
2006-07-19 |
Time |
08:30 |
Sent To |
|
|
Notes |
2006-07-19 00:00:00 | *** DENIED *** | | 1) SEE ELECTRICAL REVIEW NOTES #2, 3, 4, | | &5, PLEASE CORRECT | | | | 2) PLEASE SHOW ON MECHANICAL PLANS HOW | | ROOF TOP CONDENSER UNIT "STANDS" AND | | CONDENSER UNITS ARE TO BE SECURED TO | | ROOF AND THAT THIS COMPLIES WITH 2004 | | FBC 1606 WIND LOADS. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
2007-01-17 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2007-01-17 |
Time |
15:57 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2007-01-17 |
Time |
15:57 |
Sent To |
|
|
Notes |
2007-01-17 15:58:57 | REVISION OK - SHT P-1 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2006-10-18 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2006-10-18 |
Time |
14:09 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2006-10-18 |
Time |
14:09 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2006-09-05 |
|
|
Cont ID |
|
Sent By |
kstevens |
Date |
2006-09-05 |
Time |
16:01 |
Rev Time |
0.00 |
Received By |
kstevens |
Date |
2006-09-05 |
Time |
16:01 |
Sent To |
|
|
Notes |
2006-09-05 00:00:00 | DENIED | | REFERENCE: FBC-2004 PLUMBING | | FLORIDA ADMINISTRATIVE CODE | | FLORIDA STATUTES | | | | A. FROM PREVIOUS REVIEW: | | | | 1. SHT P-1 WATER PIPING SCHEMATIC: SEC | | 604.9 A WATER HAMMER ARRESTOR SHALL BE | | INSTALLED WHERE QUICK CLOSING VALVES ARE | | UTILIZED, AND INSTALLED PER MANUFACTUES | | SPECIFICATIONS. | | ****RESPONSE NOTED, BUT THE WATER HAMMER | | ARRESTOR REQUIRED FOR THE DISH WASHER IS | | LOCATED AT THE WATER HEATER, AND ON THE | | COLD WATER LINE. ARRESTOR SHALL BE | | LOCATED NEAR THE FIXTURE IN AN | | "EFFECTIVE RANGE" PER PDI-WH 201 AND | | MANUF. INSTALLATION INSTRUCTIONS. THE | | ARRESTOR FOR THE ICE MAKER SHALL BE | | LOCATED NEAR THE REFRIG.. | | | | **************NEW COMMENTS************** | | | | 1B. THE DATE THAT THE SIGNATURE AND SEAL | | IS AFFIXED AS PROVIDED HERIN SHALL BE | | ENTERED ON SAID PLANS OR OTHER DOCUMENTS | | IMMEDIATELY UNDER THE SIGNATURE OF THE | | PROFESSIONAL ENGINEER. 61G15-23.002(1) | | AND FS 471.025. | | | | REVIEW BY KEN STEVENS | | (561) 805-6721 | | FAX (561) 805-6731 | | E-MAIL [email protected] |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-07-02 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2006-07-02 |
Time |
11:08 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2006-07-02 |
Time |
10:59 |
Sent To |
|
|
Notes |
2006-07-02 00:00:00 | PAUL SCHMITZ | | [email protected] | | FBC 2004 PLUMBING CODE PLAN REVIEW | | FBC 2004 FUEL GAS CODEPLAN REVIEW | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | AMENDMENTS TO THE FLORIDA BUILDING CODE | | CHAPT.1, ADMINISTRATION, 2004 EDITION | | | | UNSAT | | | | 1) SHT P-1WATER PIPING SCHEMATIC: | | SEC 604.9 A WATER HAMMER ARRESTOR, SHALL | | BE INSTALLED WHERE QUICK CLOSING VALVES | | ARE UTILIZED AND INSTALLED PER | | MANFACTURES SPECIFICATIONS. | | | | 2) SPECIFY TYPE OF AIR GAP FITTING FOR | | DISH WASHER WASTE. | | | | 3) PLEASE SEE PLAN REVIEW COMMENTS BY | | OTHER PLAN REVIEWERS. | | | | END OF COMMENTS, QUESTIONS 561-805-6692 |
|
|