Plan Review Stops For Permit 06051149 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
6 |
Status |
P |
Date |
2007-12-06 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-12-06 |
Time |
17:43 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-12-06 |
Time |
17:43 |
Sent To |
PC |
|
Notes |
2007-12-06 17:46:11 | | | | | PASSED | | | | REVISION FOR BUILDING AND PLUMBING(SHEET A-1) IS | | APPROVED, ELECTRICAL SHEETS HAVE COMMENTS AND WILL NEED | | TO BE RESUBMITTED | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
5 |
Status |
P |
Date |
2007-07-07 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-07-07 |
Time |
10:03 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-07-07 |
Time |
10:03 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
4 |
Status |
F |
Date |
2007-06-28 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-06-28 |
Time |
18:09 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-06-28 |
Time |
18:09 |
Sent To |
PC |
|
Notes |
2007-06-28 18:22:58 | | | DENIED | | | | 1)THE ATTIC ACCESS CANNOT BE INSTALLED IN THE FLAT | | ROOF AREA PLEASE REVISE. | | | | 2)PLEASE PROVIDE THE FLORIDA STATEWIDE PRODUCT | | APPROVALS FOR 8" CASTCRETE LINTELS AND THE ROOF PRODUCT | | FOR THE FLAT ROOF. ASPHALT SHINGLES CANNOT BE USED ON | | ROOF SLOPES LESS THAN 2/12 | | | | 3)TRUSS ENGINEERING MUST BE SIGNED AND SEALED BY THE | | TRUSS MANUFACTURERS DESIGN PROFESSIONAL. | | | | 4)PER 713.13(2) F.S. | | IF THE IMPROVEMENT DESCRIBED IN THE NOC HAS NOT | | COMMENCED WITHIN 90 DAYS OF RECORDING THE NOTICE IS | | VOID | | | | 5)REMOVE ALL OLD PAGES AND RESUBMIT 2 COMPLETE SETS | | OF NEW DRAWINGS AND INCLUDE 1 COPY OF THE OLD PAGES | | ONLY FOR REFERENCE | | PLEASE DO NOT ATTACH PRODUCT APPROVALS TO DRAWING | | SETS. | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2007-03-31 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2007-03-31 |
Time |
12:44 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
2007-03-31 |
Time |
12:44 |
Sent To |
PC |
|
Notes |
2007-03-31 13:24:56 | | | | | DENIED | | | | ****NOTE**** | | THE FOLLOWING COMMENTS FROM THE 2ND BUILDING REVIEW | | WERE NOT ADDRESSED. | | | | 1) A RECORDED COPY OF THE NOTICE OF | | COMMENCEMENT IS REQUIRED PRIOR TO | | A PERMIT BEING ISSUED | | | | 3) SUBMIT ENERGY CALC'S PER 13-101.2.2 | | FBC. BE SURE THAT THEY ARE SIGNED AND | | DATED BY PREPARER AND OWNER/AGENT PRIOR | | TO SUBMITTAL. *****NOT SIGNED AND DATED BY | | OWNER/AGENT****** | | | | 6) THOSE PRODUCTS WHICH ARE REGULATED BY DCA RULE 9B-72 | | SHALL BE REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL FOR | | JURISDICTIONAL APPROVAL PER 106.3.3 FBC*. | | ******REVIEWED AND APPROVED BY PERSON RESPONSIBLE FOR | | DRAWINGS******* | | | | 7) SUBMIT ENGINEERED TRUSS DRAWINGS THAT | | COMPLY WITH R802.10.1 FBC WITH PERMIT | | APPLICATION OR BEFORE INSTALLATION THAT | | HAVE BEEN REVIEWED AND APPROVED BY THE | | DESIGNER OF RECORD. | | | | 9) PROVIDE A SITE PLAN THAT SHOWS DRAINAGE IN | | COMPLIANCE WITH THE REQUIREMENTS OF R403.1 ******THE | | DRAINAGE PROVISION IS TO SHOW POSITIVE DRAINAGE AWAY | | FROM NEW STRUCTURE AND ALSO SHOW THAT DOES NOT FLOW | | ONTO ADJOINING PROPERTY****** | | | | ******NEW COMMENTS****** | | | | 1) THE PROVIDED ATTIC ACCESS IS THROUGH THE PROPOSED | | GIRDER BEAM PLEASE RELOCATE TO AN AREA THAT PROVIDES | | 30" OF HEADROOM ABOVE ACCESS. | | | | 2) UNDER THE EXISTING BUILDING CODE ADDITIONS ARE | | TREATED AS NEW CONSTRUCTION AND THE ACCESSIBILITY | | REQUIREMENTS OF ONE BATHROOM WITH A MIN 29" CLEAR | | OPENING WITH DOOR AT 90 DEGREES IS REQUIRE PER R322.1.1 | | FBC | | | | 3) UNDER THE EXISTING BUILDING CODE ADDITIONS, SMOKE | | ALARMS SHALL BE PROVIDED IN THE EXISTING PORTIONS OF | | THE BUILDING PER 904.2 FBC (EXISTING) | | | | 4) THE CITY OF WEST PALM BEACH REQUIRES THE FLORIDA | | STATE PRODUCT APPROVAL COVER | | SHEETS WHEN AVAILABLE. THEY CAN BE SEARCHED FOR ON | | WWW.FLORIDABUILDING.ORG.WHEN AVAILABLE AND NOT | | SUBMITTED APPLICATIONS WILL BE DENIED. | | PLEASE NOTE THAT I HAVE PRINTED THESE FOR YOUR WINDOWS | | AND PRECAST LINTELS | | | | 5) PROVIDE NEW UPDATED MIAMI-DADE NOA'S FOR THE | | OAKRIDGE PRO 40 SHINGLES AS THIS NOA HAS EXPIRED. ALSO | | A NOA WILL BE REQUIRED FOR THE FLAT ROOF I WOULD | | SUGGEST THAT YOUR ROOFING CONTRACTOR SUPPLIES YOU WITH | | THIS PRODUCT APPROVAL AS THERE ARE THOUSANDS OF | | VARIATIONS AND THE EXACT ONE MUST BE CHOSEN AND | | INSTALLED TO PASS INSPECTION. PROVIDE PRODUCT APPROVAL | | FOR MULLION WHERE 2 OR MORE WINDOWS ARE JOINED TOGETHER | | AS IN MASTER BEDROOM. | | | | BLDG PLAN REVIEW | | ADRIAN MORSE | | 561-805-6716 | | | | | | | | | | | | |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
F |
Date |
2006-10-24 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-03-01 |
Time |
11:26 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-10-24 |
Time |
08:09 |
Sent To |
|
|
Notes |
2006-10-24 08:14:57 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | SHALL BE RECORDED AT PALM BEACH COUNTY | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | BLANK FORMS ARE AVAILABLE FROM THIS | | OFFICE. | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF | | THE DESCRIBED IMPROVEMENT | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | 90 DAYS OF RECORDING. | | | | 2.BASED ON ICC BUILDING VALUATION DATA | | THE PERMIT VALUE WIL HAVE TO BE REVISED. | | | | A MINIMUM OF $112,596 IS REQUIRED JUST | | FOR THE ROOM ADDITION PLUS THE CARPORT | | ENCLOSURE.ADDITIONAL PERMIT FEES ARE | | DUE. | | | | 3.SIGN OWNER/AGENT ON ENERGY CALCS. | | | | 4.PRODUCT APPROVALS REQUIRED FOR | | LINTELS. | | **SUBMIT TWO COMPLETE SETS OF ALL PRODUCT APPROVALS | | WITH THE APPROPRIATE STATE PRODUCT APPROVAL ATACHED | | | | 5.ALL PRODUCT APPROVALS SUBMITTED WITH | | QUALITY ASSURANCE SHALL HAVE THE | | FOLLOWING STATE APPROVAL ATTACHED. | | | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A STATE PRODUCT APPROVAL | | SHEETS THAT LISTS THE PRODUCT IDENTITY | | NUMBER FROM THE STATE. IF THE PRODUCT | | DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT | | AN APPLICATION FOR LOCAL PRODUCT | | APPROVAL OR SITE SPECIFIC FORM PER RULE | | 9B-72. SEE ATTACHMENT. | | WWW.FLORIDABUILDING.ORG | | | | 6.THOSE PRODUCT APPROVALS WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL.WPB | | AMENDMENT TO FBC 106.3.3. | | | | 7.SUBMIT TWO SETS OF TRUSS DRAWINGS | | FOR REVIEW PRIOR TO INSTALLATIONPER 2004 FBC | | R-802.10.1 | | | | 8.A DESIGN PROFESSIONAL OR AN OWNER | | MUST ELECT ONE OR A COMBINATION OF | | LEVELS OF ALTERATION PURSUANT TO | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | SHOW HOW PLANS WILL COMPLY WITH THE | | SECTION(S) SELECTED.2004 FBC EXISTING | | BUILDING 301.5 | | | | 9.R401.3 DRAINAGE. | | SURFACE DRAINAGE SHALL BE DIVERTED TO A | | STORM SEWER CONVEYANCE OR OTHER APPROVED | | POINT OF COLLECTION SO AS TO NOT CREATE | | A HAZARD. LOTS SHALL BE GRADED SO AS TO | | DRAIN SURFACE WATER AWAY FROM FOUNDATION | | WALLS. THE GRADE AWAY FROM FOUNDATION | | WALLS SHALL FALL A MINIMUM OF 6 INCHES | | WITHIN THE FIRST 10 FEET. | | | | IMPORTANT; | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | OLD PAGES FOR REFERENCE . A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET | | OR SPECIFICATION PAGE WHERE THE CHANGES | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | ART LANGE | | CONSTRUCTION SERVICES DEPARTMENT | | BUILDING PLANS EXAMINER | | 561-805-6672 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-06-29 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-06-29 |
Time |
11:32 |
Rev Time |
1.50 |
Received By |
alange |
Date |
2006-06-29 |
Time |
11:10 |
Sent To |
|
|
Notes |
2006-06-29 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | SHALL BE RECORDED AT PALM BEACH COUNTY | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | BLANK FORMS ARE AVAILABLE FROM THIS | | OFFICE. | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE RE-RECORDED IF | | THE DESCRIBED IMPROVEMENT | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | 90 DAYS OF RECORDING. | | | | 2.BASED ON ICC BUILDING VALUATION DATA | | THE PERMIT VALUE WIL HAVE TO BE REVISED. | | | | A MINIMUM OF $112,596 IS REQUIRED JUST | | FOR THE ROOM ADDITION PLUS THE CARPORT | | ENCLOSURE.ADDITIONAL PERMIT FEES ARE | | DUE. | | | | 3.SIGN OWNER/AGENT ON ENERGY CALCS. | | | | 4.PRODUCT APPROVALS REQUIRED FOR | | LINTELS AND OVEWRHEAD GARAGE DOOR. | | SUBMIT TWO COMPLETE SETS OF ALL PRODUCT APPROVALS. | | | | 5.ALL PRODUCT APPROVALS SUBMITTED WITH | | QUALITY ASSURANCE SHALL HAVE THE | | FOLLOWING STATE APPROVAL ATTACHED. | | | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A STATE PRODUCT APPROVAL | | SHEETS THAT LISTS THE PRODUCT IDENTITY | | NUMBER FROM THE STATE. IF THE PRODUCT | | DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT | | AN APPLICATION FOR LOCAL PRODUCT | | APPROVAL OR SITE SPECIFIC FORM PER RULE | | 9B-72. SEE ATTACHMENT. | | WWW.FLORIDABUILDING.ORG | | | | 6.THOSE PRODUCT APPROVALS WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL.WPB | | AMENDMENT TO FBC 106.3.3. | | | | 7.SUBMIT TWO SETS OF TRUSS DRAWINGS | | FOR REVIEW PER 2004 FBC R-802.10.1 | | | | 8.A DESIGN PROFESSIONAL OR AN OWNER | | MUST ELECT ONE OR A COMBINATION OF | | LEVELS OF ALTERATION PURSUANT TO | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | SHOW HOW PLANS WILL COMPLY WITH THE | | SECTION(S) SELECTED.2004 FBC EXISTING | | BUILDING 301.5 | | | | 9.R401.3 DRAINAGE. | | SURFACE DRAINAGE SHALL BE DIVERTED TO A | | STORM SEWER CONVEYANCE OR OTHER APPROVED | | POINT OF COLLECTION SO AS TO NOT CREATE | | A HAZARD. LOTS SHALL BE GRADED SO AS TO | | DRAIN SURFACE WATER AWAY FROM FOUNDATION | | WALLS. THE GRADE AWAY FROM FOUNDATION | | WALLS SHALL FALL A MINIMUM OF 6 INCHES | | WITHIN THE FIRST 10 FEET. | | | | 10.FOOTING DEPTH SHALL BE A MINIMUM OF | | 12" BELOW UNDISTURBED SOIL R-403.1.4 | | | | 11.NOTE: SEPERATE PERMITS REQUIRED FOR | | ALL TRADES. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | OLD PAGES FOR REFERENCE . A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET | | OR SPECIFICATION PAGE WHERE THE CHANGES | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION. | | | | ART LANGE | | CONSTRUCTION SERVICES DEPARTMENT | | BUILDING PLANS EXAMINER | | 561-805-6672 |
|
|
Review Stop |
B1 |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
N |
Date |
2007-07-07 |
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
10:00 |
Rev Time |
0.00 |
Received By |
amorse |
Date |
|
Time |
10:00 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
6 |
Status |
P |
Date |
2008-03-26 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2008-03-26 |
Time |
11:42 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2008-03-26 |
Time |
11:42 |
Sent To |
PC |
|
Notes |
2008-03-26 11:44:31 | TO VIF THE ACTUAL FEEDERS FROM METER/MAIN PANEL TO SUB | | PANEL. RISER SHOWS #3 AND PANEL SCHEDULE SHOWS #2. | | LOAD CALCULATIONS STATES SERVICE IS EXISTING WHEN | | SERVICE ON PLANS AND LOCATION AT JOB IS NEW. OLD | | METER/SERVICE IS BEING REMOVED. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
5 |
Status |
F |
Date |
2007-11-09 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-11-09 |
Time |
10:50 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-11-09 |
Time |
09:39 |
Sent To |
P |
|
Notes |
2007-11-09 10:50:31 | ** DENIEDREVISION ** | | | | | | 1) NOTE: PLEASE SEE PLANS AND RISER CALL FOR A NEW | | 120AMP DISCONNECT AND PANEL HOWEVER 120AMP IS NOT A | | RECOGNIZED STANDARD SIZE OF OVER CURRENT PROTECTION. | | PLEASE SEE 240.6. | | | | 2) NOTE: PLEASE COMPLETE PLANS AND RISER WITH ALL | | MINIMUM REQUIRED CONDUCTORS. | | 240.4, 310.16 | | | | 3) NOTE: PLEASE SEE THAT THE PLANS ARE REQUIRED TO BE | | SIGNED BY THE DESIGNER OF RECORD. | | FBC 106.1.2, 106.5 | | | | IF THERE ARE ANY QUESTIONS, PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW II | | CONSTRUCTIONS SERVICES DEPARTMENT | | CITY OF WEST PALM BEACH | | 561-805-6717 |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
4 |
Status |
P |
Date |
2007-06-20 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-06-20 |
Time |
14:24 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-06-20 |
Time |
14:16 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
F |
Date |
2007-03-01 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2007-03-01 |
Time |
09:16 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2007-03-01 |
Time |
07:20 |
Sent To |
M |
|
Notes |
2007-03-01 09:17:04 | *** UNSAT 3RD REVIEW *** | | | | ** PLEASE SEE SCOPE OF WORK AND PLANS HAS NOW | | COMPLETELY CHANGED. PLEASE SEE COMMENTS. | | | | 1) NOTE: PLEASE SEE PLANS NOW CALL FOR FAMILY ROOM AS | | EXISTING WHEREAS THE PREVIOUS TWO SETS OF PLANS | | SUBMITTED INDICATED THIS AREA AS A NEW PROPOSED | | ADDITION. PLEASE CLARIFY THIS AS REVIEW IS NOW CONFUSED | | OVER SEPARATE PLANS FOR NEW AND EXISTING. | | FBC 106.1.2 | | | | 2) NOTE: PLEASE SEE FBC R313 FOR NEW SMOKE ALARMS | | NEEDED. PLEASE ALSO SEE NOTE BELOW. | | ** | | PLEASE KNOW THAT A MEETING WAS HELD AT THE SOUTHERN | | SECTION MEETING IN OCT 06 WHERE WE WERE DIRECTLY | | INFORMED BY NFPA THAT THE USE OF SD FOR SMOKE DETECTORS | | ON PLANS FOR RESIDENTIAL HOMES IS NOT ACCEPTABLE WHEN | | THESE DEVICES ANY ACTUALLY FALL UNDER THE DEFINITIONS | | OF SMOKE ALARMS WHICH WOULD BE SHOWN AS SA/SMOKE | | ALARMS. | | THIS INFORMATION WAS NEW TO THIS AHJ AS THE GENERAL USE | | OF THE SD FOR SMOKE DETECTORS WAS ALWAYS ACCEPTED. | | BY THE DEFINITIONS AS STATED IN NFPA-72 A SD/ SMOKE | | DETECTOR IS ONLY A DEVICE WHICH WILL DETECT AND WILL | | NOT SOUND AN AUDIBLE ALARM. THIS WOULD BE DONE BY | | HORN/SIREN TYPE DEVICES. PLEASE SEE THE DEFINITIONS OF | | SA/SMOKE ALARMS; THESE ARE DEVICES WHICH ARE 120V (AS | | SHOWN) AND WOULD DETECT AND SOUND AN ALARM. THIS IS | | SOMETHING THAT IS NOW BEING COMMENTED ON OTHER REVIEWS | | FOR OTHER NEW HOMES. | | ** PLEASE SEE THAT SMOKE ALARMS ARE STATED IN THE FBC | | RESIDENTIAL CODE/ FBC AND IN NFPA-72. | | IF THERE ARE ANY QUESTIONS ON THIS COMMENT PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE*. | | | | 3) NOTE: PLEASE SEE RISER AND PANEL AND NOTES FOR PANEL | | DO NOT CORRELATE. SHOWS 200AMP MAIN BREAKER ON A 150AMP | | PANEL AND ALSO SHOWS A 150AMP RATED MAIN?? | | 106.1.2. | | NEC 230.70, 310.16, 240.4 ETC | | | | 4) NOTE: PLEASE SEE THE SEALS ON PLANS ARE NOT CLEAR | | AND VISIBLE ON PLANS AS REQUIRED PER FAC 61G15-23.001, | | .002 AND FS 471.025. | | THIS IS REQUIRED FOR ALL SHEETS AND FOR ALL TRADES | | WHETHER OR NOT COMMENT IS MADE BY OTHER TRADES. | | | | 5) NOTE: PLEASE SEE MISSING RECEPTACLE(S) PER 210.52, | | REDLINED IN ADDITION. | | | | 6) NOTE: PLEASE SEE MISSING COUNTER SPACE GFI PER | | 210.8A6. | | | | 7) NOTE: PLEASE SEE PLANS INDICATE A NEW STOVE, YET NO | | RECEPTACLE OUTLET IS BEING SHOWN FOR THIS? PLEASE ALSO | | SEE THAT THE REFRIGERATOR IS BEING SHOWN THE SAME WAY. | | PANEL SCHEDULE INDICATES BOTH OF THESE. | | PLEASE CORRELATE. | | 106.1.2. | | | | 8) NOTE:PLEASE SEE DISHWASHER AND DISPOSAL BEING | | SHOWN ON THE SAME SINGLE POLE CIRCUIT WHICH WILL PLACE | | LOAD ON THIS CIRCUIT WHICH EXCEEDS THAT OF THE RATING | | OF SAID BREAKER. | | PLEASE SEE 210.4. | | PLEASE SEE 240, 310.16, 422ETC | | PLEASE SEE FBC 106.3.5.4 | | | | 9) NOTE: PLEASE SEE PANEL SCHEDULE WHICH IS MISSING THE | | TWO REQUIRED SMALL APPLIANCE CIRCUITS AS SHOWN IN LOAD | | CALCULATIONS. | | 210.52B1, 210.11C1, 220.16 | | | | 10) NOTE: PLEASE SEE THE OVER CURRENT PROTECTION FOR | | THE AHU IS BEING SHOWN IS HIGH FOR A UNIT WHICH IS | | BEING SHOWN AS 7.5KW ON LOAD CALCULATIONS. PLEASE SEE | | THE MECHANICAL PLANS INDICATE THIS UNIT AS 10KW. IF | | INDEED THIS IS THE CASE, THEN REVISE THE LOAD | | CALCULATIONS AND NOT THE OVER CURRENT PROTECTION OF THE | | BREAKER AS SHOWN ON PANEL SCHEDULE. | | 240.4, 310.16 ETC | | PLEASE SEE 220.31B FOR LOAD CALCULATIONS FOR ADDITIONS | | TO EXISTING DWELLINGS. | | PLEASE SEE THAT PLANS SEEM TO BE INDICATING A NEW CU, | | OR IS THIS RELOCATED. PLEASE SEE THE CLEARANCE REQUIRED | | FOR A/C EQUIPMENT ON THE ELECTRICAL PLANS DOES NOT SEEM | | TO BE MET FOR MINIMUM REQUIRED FOR CU EQUIPMENT. PLEASE | | SEE THE MECHANICAL PLANS ARE DIFFERENT. | | 110.26 AND SEE MECHANICAL CODE FOR THEIR MINIMUM | | REQUIRED. | | | | 11) NOTE: PLEASE SEE MISSING GFI FOR NEW CU. 210.63, | | 210.8A2 | | | | 12) NOTE: PLEASE SEE OTHER CIRCUITS BEING SHOWN ON | | PANEL SCHEDULE WHICH ARE SHOWN AS BLANK OR OTHER 2-POLE | | BREAKERS AS SPARES?? | | PLEASE CLARIFY. | | PLEASE INDICATE THE CIRCUITS FOR NEW WIRING AND ANY | | EXISTING AS SUCH. | | 408.6, 240.4, 310.16, | | FBC 106.3.5.4 | | | | 13) NOTE: ** PLEASE KNOW THAT ONE SET OF EACH SET OF | | PLANS WILL BE RETAINED AND PLACED WITH PREVIOUS HELD | | PLANS FOR THE SAME DESIGNER OF RECORD AND FORWARDED TO | | THE STATE OF FLORIDA, AND FLORIDA BOARD OF PROFESSIONAL | | ENGINEERS. PLEASE SEE FS 471.025(3) | | | | * ** IMPORTANT** | | ONCE ALL REVIEWS ARE DONE AND PLANS ARE | | PICKED UP FOR CORRECTIONS, PLEASE BE | | SURE TO COMPLETELY REMOVE ALL OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO TWO COMPLETE SETS FOR REVIEW | | AND STAMPING. DO NOT LEAVE ANY | | OLD/VOIDED SHEETS IN SETS. | | PLEASE KNOW ONLY ONE SET OF THE | | OLD/VOIDED SHEETS SHOULD BE SUBMITTED | | FOR REFERENCE. | | THIS WILL HELP IN THE REVIEW PROCESS AND | | AVOID ANY DELAYS. | | | | ** PLEASE BE SURE TO CALL IF THERE ARE ANY QUESTIONS OR | | COMMENTS WITH RESPECT TO THE TYPED COMMENTS ABOVE. IF | | THERE ARE ANY COMMENTS WHICH ARE NOT CLEAR IN ANY WAY, | | NOT UNDERSTOOD OR NOT TYPED IN A CLEAR MANOR, PLEASE DO | | NOT HESITATE IN CONTACTING THIS OFFICE AND THIS | | REVIEWER. | | | | | | | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CONSTRUCTION SERVICES DEPT. | | CITY OF WEST PALM BEACH | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
F |
Date |
2006-10-15 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-10-15 |
Time |
20:50 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-10-15 |
Time |
20:35 |
Sent To |
P |
|
Notes |
2006-10-15 20:50:20 | ********* UNSAT2ND REVIEW ************* | | | | ** PLEASE SEE SOME COMMENTS FROM PREVIOUS REVIEW ALONG | | WIHT SOME NEW COMMENTS DUE TO THE PLANS SUBMITTED FOR | | THIS REVIEW. | | | | | | 1)NOTE: OK. | | | | 2) NOTE: OK. | | | | 3) NOTE: OK. | | | | 4) NOTE: OK. | | | | 5) NOTE: OK. | | | | 6) NOTE:NO, SAME NOTE. PLEASE STILL MISSING | | DISCONNETC FOR WH AND MIN CLEARENACE FOR BOTH THE CU | | AND AHU. | | | | ** PREVIOUS REVIEW NOTE ** | | ]PLEASE INCLUDE ALL MIN | | CLEARENCES FOR DISCONNECTS FOR CU, AHU | | AND WATER HEATER. | | 110.26. | | PLEASE ALSO INCLUDE ALL DISCONNECTS. | | 440.11,422.31 ETC. | | | | 7) NOTE: NO, PLEASE STILL SEE MISSINGRECEPTS AS | | REQUIRED. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SEE MISSING RECEPTS | | REQ'D PER 210.52 | | | | 8) NOTE:OK. | | | | 9) NOTE: OK, HOWEVER STILL SEE ZONING COMMENTS AS THIS | | MAY AFFECT PLANS. | | | | ** PREVIOUS REVIEW NOTE ** | | PLEASE SEE SUBSTANTIAL COMMENTS | | FROM ZONING WHICH WILL AFFECT PLANS AND | | DESIGN. | | | | 10) NOTE: OK. | | | | ** NEW NOTE ** | | 11) NOTE: PLEASE SEE NOTE BELOW WHICH REQUESTED ALL | | OLD/VOIDED SHEETS TO BE REMOVED AND INSERT NEW SHEETS | | INTO COMPLETE SETS FOR REVIEW AND PROCESSING. PLEASE | | SEE THIS WAS NOT DONE. SHEETS ARE LOOSE AND NOT IN | | SETS. PLEASE KNOW, WHEN PLANS COME BACK AND THIS IS NOT | | DOWN, PLANS WILL BE REQUIRED TO BE PICKED UP BEFORE | | REVIEWS WILL COMMENCE. | | | | ** PREVIOUS NOTE** | | ** WHEN RESUBMITTING PLANS, PLEASE BE | | SURE TO COMPLETELT REMOVE ANY OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO COMPLETED SETS FOR REVIEW | | AND STAMPING. | | PLEASE SUBMIT ONLY ONE COPY OF THE | | OLD/VOIDED SHEETS. | | | | 12) NOTE: PLEASE SEE FS 553.80(2)(B) WITH RESPECT TO | | REPEAT COMMENTS FOR CODE COMPLIANCE. | | THIS IS ONLY A NOTICE GIVEN AT THIS TIEM, HOWEVER | | ELECTRICAL PLANS ARE BEING RETAINED. | | | | 13) NOTE: PLEASE CORRELATE RISER AND PLANS AS PLANS | | SHOW A MAIN DISCONNECT AND RISER DOES NOT. | | FBC 106.1.2, 106.3.5.4 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | | | | | | | | | | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-06-13 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-06-13 |
Time |
20:01 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-06-13 |
Time |
19:38 |
Sent To |
P |
|
Notes |
2006-06-13 00:00:00 | ********* UNSAT ************* | | | | | | 1)NOTE: PLEASE SUBMIT AIC RATINGS FOR | | ALL NEW SERVICE EQUIPMENT BEING INSTALL- | | ED. MAINS/BRKRS AND PANELS ARE ALL TO BE | | RATED FOR THE AVAILABLE FAULT CURRENT. | | PER 110.9/215.5 | | | | 2) NOTE: PLEASE SHOW ALL RECEPTS SERVING | | KITCHEN COUNTERSPACE AS GFI/GFI PROTECT- | | -ED PER 210.8A-6 (IF EXISTING SHOW, IF | | NOT EXISTING GFI, THEN GFI RECEPTS WILL | | BE REQUIRED IN KITCHEN AS PART OF A | | LEVEL 3 ALTERATION IN THE FBC EXISTING | | BUILDING CODE AND NEC. | | | | 3) NOTE: PLEASE LIST ALL THE REQ'D | | DEDICATED BATH(S) CIRCUIT(S) ON PANEL | | SCHEDULE. PER 210.52D, 210.11C3 | | PLEASE SEE MISSING RECEPT(S) ETC. | | PLEASE SEE EXISTING BATH WILL BE | | REQUIRED TO EITHER CONTAIN A NEW 20A GFI | | CIRCUIT OR SHOW AS EXISTING. | | | | 4) NOTE: PLEASE SUBMIT A PANEL SCHEDULE | | SHOWING ALL MIN REQUIRED CIRCUITS, | | CONDUCTOR AND OCP SIZES. | | 240.4,310.16,215.5,408.4 | | | | 5) NOTE: PLEASE SHOW ALL SD'S IN | | EXISTING DWELLING. IF EXISTING, SHOW, IF | | NOT NEW SD'S WILL BE REQUIRED. | | R-313, NFPA-72 11.5.1.1., 11.8.3.5 | | THIS IS A LEVEL-3 ALTERATION WHICH ALSO | | INCLUDES LEVELS 1 AND 2 AND R-313 AND | | ADDTIONS COVERED IN THE RESIDENTIAL 2004 | | FBC. | | | | 6) NOTE: PLEASE INCLUDE ALL MIN | | CLEARENCES FOR DISCONNECTS FOR CU, AHU | | AND WATER HEATER. | | 110.26. | | PLEASE ALSO INCLUDE ALL DISCONNECTS. | | 440.11,422.31 ETC. | | | | 7) NOTE: PLEASE SEE MISSING RECEPTS | | REQ'D PER 210.52 | | | | 8) NOTE: PLEASE SEE MISSING REQUIRED LT | | FIXTURE OF SOME SORT AT LOCATIONS SHWON | | AS "J-BOX" . 210.70,NFPA-101 7.8, | | CHAPTER 24 RESIDENTIAL. | | | | 9) NOTE: PLEASE SEE SUBSTANTIAL COMMENTS | | FROM ZONING WHICH WILL AFFECT PLANS AND | | DESIGN. | | | | 10) NOTE: PLEASE SEE | | 220.16,210.11,210.52F FOR MIN VA FOR WASHER/LAUNDRY | | CIRCUIT. 1500VA MIN. | | | | ** WHEN RESUBMITTING PLANS, PLEASE BE | | SURE TO COMPLETELT REMOVE ANY OLD/VOIDED | | SHEETS AND ONLY INSERT NEW REVISED | | SHEETS INTO COMPLETED SETS FOR REVIEW | | AND STAMPING. | | PLEASE SUBMIT ONLY ONE COPY OF THE | | OLD/VOIDED SHEETS. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | | | | | | | | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
11 |
Status |
N |
Date |
2008-03-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2008-03-25 |
Time |
15:02 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2008-03-25 |
Time |
15:02 |
Sent To |
E |
|
Notes |
2008-03-25 15:02:22 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
10 |
Status |
N |
Date |
2007-11-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-11-07 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-11-07 |
Time |
14:50 |
Sent To |
E |
|
Notes |
2007-11-07 14:50:52 | TO "DPALMER" DESK/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
9 |
Status |
N |
Date |
2007-07-05 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-07-05 |
Time |
08:56 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-07-05 |
Time |
08:56 |
Sent To |
B |
|
Notes |
2007-07-05 08:57:10 | TO "AMORSE" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
8 |
Status |
N |
Date |
2007-06-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-06-19 |
Time |
14:39 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-19 |
Time |
14:39 |
Sent To |
E |
|
Notes |
2007-06-19 14:40:06 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
7 |
Status |
N |
Date |
2007-06-04 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2007-06-19 |
Time |
10:42 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-06-04 |
Time |
11:43 |
Sent To |
Z |
|
Notes |
2007-06-04 11:43:41 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
6 |
Status |
N |
Date |
2007-02-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-27 |
Time |
17:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-27 |
Time |
17:54 |
Sent To |
E |
|
Notes |
2007-02-27 17:55:07 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2007-02-20 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2007-02-20 |
Time |
18:21 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2007-02-20 |
Time |
18:21 |
Sent To |
Z |
|
Notes |
2007-02-20 18:21:41 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-10-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-12 |
Time |
14:54 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-12 |
Time |
14:54 |
Sent To |
E |
|
Notes |
2006-10-12 14:55:00 | TO "DPALMER" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-10-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-06 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-06 |
Time |
11:27 |
Sent To |
Z |
|
Notes |
2006-10-06 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-06-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-12 |
Time |
10:26 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-12 |
Time |
10:26 |
Sent To |
E |
|
Notes |
2006-06-12 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-06-29 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-06-29 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-05-27 |
Time |
13:51 |
Sent To |
|
|
Notes |
2006-05-27 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
3 |
Status |
P |
Date |
2007-06-21 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-06-21 |
Time |
07:54 |
Rev Time |
0.30 |
Received By |
tgordon |
Date |
2007-06-21 |
Time |
07:54 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
F |
Date |
2007-03-01 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2007-03-01 |
Time |
11:27 |
Rev Time |
0.45 |
Received By |
tgordon |
Date |
2007-03-01 |
Time |
11:27 |
Sent To |
P |
|
Notes |
2007-03-01 11:54:25 | *** DENIED *** | | 1) ENERGY CALCULATIONS NEED TO BE SIGNED BY OWNER/AGENT | | ALSO, PER 2004 FBC 13-600.3.ABC.2. | | | | 2) THE MECHANICAL PLANS NEED THE PREPARER'S SIGNATURE | | ON THEM. ALL INFORMATION, DRAWINGS, SPECIFICATIONS AND | | ACCOMPANYING DATA SHALL BEAR THE PRINTED NAME AND | | SIGNATURE OF THE PERSON RESPONSIBLE FOR THE DESIGN. PER | | FBC 104.2.1 . | | | | 3) THE MECHANICAL PLANS ARE SHOWING A 4" SUPPLY AIR | | DUCT TO THE MASTER BEDROOM WITH 196 CFM'S, THAT WOULD | | BE AT A VELOCITY OF 2250 FPM. MANUAL J CALCULATIONS | | STATE MAXIMUM VELOCITY TO BE 900 FPM, PLEASE CORRECT. | | | | 4) MECHANICAL PLANS SHOW A 10" SUPPLY AIR DUCT TO THE | | MIXING BOX FOR THE MASTER SUITE, THIS WOULD REQUIRE A | | 14" RETURN AIR TRANSFER DUCT. PLANS DO NOT STATE IF THE | | RETURN AIR DUCT IS A TRANSFER DUCT OR DIRECT DUCTED TO | | THE AHU, PLEASE CORRECT. | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2007-03-01 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-06-16 |
Time |
14:47 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2006-06-16 |
Time |
14:47 |
Sent To |
B |
|
Notes |
2006-06-16 00:00:00 | NO MECHANICAL PLANS SUBMITTED, AND NO | | MECHANICAL PERMIT NUMBER APPLIED FOR AT | | THIS TIME. | | | | *** SEE REVIEW 3-1-07 *** |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
5 |
Status |
P |
Date |
2007-11-28 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-11-28 |
Time |
07:10 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-11-28 |
Time |
07:10 |
Sent To |
B |
|
Notes |
2007-11-28 07:12:51 | REVISED MASTER BATH LAY OUT. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
4 |
Status |
P |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2007-06-26 |
Time |
|
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-06-26 |
Time |
13:38 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
F |
Date |
2007-03-12 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2007-03-12 |
Time |
07:42 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2007-03-12 |
Time |
07:42 |
Sent To |
B |
|
Notes |
2007-03-12 07:58:15 | DENIED; | | 1. AUTOMATIC CLOTHES WASHER; ALL SINGLE FAMILY HOMES | | ARE REQUIRED TO HAVE A HOOK UP FOR W/M SEE FBC-2004 | | PLUMBING TABLE 403.1(R3). | | 2. RISER DIAGRAM DOES NOT MATCH FLOOR PLAN. | | 3. TWO WAY CLEANOUT REQUIRED WERE THE BUILD DRAIN MEETS | | THE BUILDING SEWER. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2006-10-21 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-10-21 |
Time |
13:58 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-10-21 |
Time |
13:58 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-06-16 |
|
|
Cont ID |
|
Sent By |
jleech |
Date |
2006-06-16 |
Time |
09:19 |
Rev Time |
0.00 |
Received By |
jleech |
Date |
2006-06-16 |
Time |
09:18 |
Sent To |
M |
|
Notes |
2006-06-16 00:00:00 | DENIED; | | 1.RISER DIAGRAM; L.T. MISSING, W/M | | OUTLET TO BE 2" NOT 1 1/2", AND A | | CLEANOUT SHOULD BE AT 48" AFF. | | PLUMBING PLAN REVIEW BY; | | JOHN LEECH | | 805-6695 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
4 |
Status |
P |
Date |
2007-06-19 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2007-06-15 |
Time |
12:16 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2007-06-19 |
Time |
10:42 |
Sent To |
I |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
F |
Date |
2007-02-26 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2007-02-26 |
Time |
14:37 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2007-02-26 |
Time |
14:36 |
Sent To |
I |
|
Notes |
2007-02-26 14:39:05 | FAILED | | | | 1) SHOW ALL DIMENSIONS FOR THE ADDITION ON THE SITE | | PLAN. | | | | 2) SHOW THE AC UNIT AND ITS SETBACK DIMENSION ON THE | | SITE PLAN. | | | | 3) SHOW THE WESTERN SETBACK FROM THE HOUSE TO THE | | PROPERTY LINE. | | | | 4) PROVIDE A SURVEY. | | | | CONTACT ERIC SCHNEIDER @ (561) 822-1435. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2006-10-11 |
|
|
Cont ID |
|
Sent By |
eschneid |
Date |
2006-10-11 |
Time |
18:03 |
Rev Time |
0.00 |
Received By |
eschneid |
Date |
2006-10-11 |
Time |
17:55 |
Sent To |
|
|
Notes |
2006-10-11 18:17:47 | 1) SHOW ALL DIMENSIONS FOR THE ADDITION ON THE SITE | | PLAN. | | | | 2) SHOW THE AC UNIT AND ITS SETBACK DIMENSION ON THE | | SITE PLAN. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-06-10 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-06-10 |
Time |
09:45 |
Rev Time |
0.00 |
Received By |
MMCLEAN |
Date |
2006-06-10 |
Time |
17:54 |
Sent To |
I |
|
Notes |
2006-06-10 00:00:00 | DENIED, | | 1. THE PROPOSED WORK ADDITION & NEW | | CARPORT ENCLOSURE MUST MEET THE CURRENT | | SETBACK FOR SF7 (SEC 94-72) | | SIDE: FIVE FEET MINIMUM, 15FT TOTAL | | 2. THE COMPLETE DEMO OF CARPORT FOR NEW | | CARPORT MUST MEET THE CURRENT ZONING | | CODE | | 3. SITE PLANS (SCALE) SHOW THE SIDE | | SETBACK AT 4' AND 3'11", BUT SHOWS BELOW | | THE REQUIRED MIN., NEED TO CLARIFY. | | | | | | NOTE: THE PROPOSED ADDITION CANNOT | | PROJECT INTO THE 12' EASEMENT IN THE | | REAR OF PROPERTY. | | | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|