Plan Review Stops For Permit 06050979 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2006-06-12 |
|
|
Cont ID |
|
Sent By |
rnuquist |
Date |
2006-06-12 |
Time |
19:12 |
Rev Time |
0.00 |
Received By |
rnuquist |
Date |
2006-06-12 |
Time |
19:12 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-07-10 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-07-10 |
Time |
08:30 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-07-10 |
Time |
08:21 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-06-13 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-06-13 |
Time |
15:01 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-06-13 |
Time |
14:20 |
Sent To |
P |
|
Notes |
2006-06-13 00:00:00 | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} THE PERSON TAKING RESPONSIBILITY FOR | | THE DESIGN MUST PRINT AND SIGN THEIR | | NAME TO SAME PER 106.3.4.2. FBC AS | | AMENDED. THIS ARTICLE ALSO IS AN | | EXTRACTION FROM THE EXEMPTION IN CHAPTER | | 471 OF THE FLORIDA STATUTES , 471.003, | | ALLOWING THE CONTRACTOR TO DRAW THEIR | | OWN PLANS. | | | | 2} SHEET ? SHOWS "OUT TO FPL"TO OR FROM | | A DISCONNECT.PLEASE CLARIFY. | | | | 3} PROVIDE SPECIFICATIONS FOR THE | | TRANSFER SWITCH. | | | | 4} PLEASE LOCATE ALL SERVICE | | EQUIPMENT ON A SITE PLAN, METER | | ENCLOSURE, DISCONNECTS, PANELS,GENERATOR | | AND TRANSFER SWITCH, SO THAT COMPLIANCE | | WITH ARTICLES 225 AND 230 CAN BE | | REVIEWED. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | WILLIAM R. TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | CONSTRUCTION SERVICES DEPARTMENT | | 561) 805-6718 | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2006-06-14 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-06-14 |
Time |
16:29 |
Rev Time |
0.15 |
Received By |
mperson |
Date |
2006-06-14 |
Time |
16:29 |
Sent To |
M |
|
Notes |
2006-06-14 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | BEFORE FINAL GEN/RES INSPECTION. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-07-03 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-03 |
Time |
13:12 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-03 |
Time |
13:12 |
Sent To |
E |
|
Notes |
2006-07-03 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-06-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-26 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-26 |
Time |
15:25 |
Sent To |
Z |
|
Notes |
2006-06-26 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-06-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-01 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-01 |
Time |
16:37 |
Sent To |
E |
|
Notes |
2006-06-01 00:00:00 | TO "GEN-RES" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-06-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-19 |
Time |
15:23 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-24 |
Time |
18:40 |
Sent To |
|
|
Notes |
2006-05-24 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2006-06-19 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-06-19 |
Time |
09:45 |
Rev Time |
0.05 |
Received By |
tgordon |
Date |
2006-06-19 |
Time |
09:45 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2006-06-14 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-06-14 |
Time |
16:28 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2006-06-14 |
Time |
16:28 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2006-06-30 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-06-30 |
Time |
16:29 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-06-30 |
Time |
16:29 |
Sent To |
I |
|
Notes |
2006-06-30 00:00:00 | NOTE: | | THE PROPOSED GENERATOR SHALL NOT BE | | CLOSER THAN 1FT FROMSIDE PROPERTY | | LINE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-05-27 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-05-27 |
Time |
19:21 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-05-27 |
Time |
19:21 |
Sent To |
I |
|
Notes |
2006-05-27 00:00:00 | DENIED, | | 1. MUST SHOW THE SIDE & REAR SETBACK OF | | THE PROPOSED GENERATOR ON TWO COPY OF | | CURRENT SURVEY. | | 2. GENERATOR MUST NOT BE LOCATED IN THE | | UTITLITY EASMEN. | | 3. MUST BE LOCATED IN THE REQUIRED REAR | | SETBACK OF PROPERTY | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|