Plan Review Stops For Permit 06050978 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2006-06-12 |
|
|
Cont ID |
|
Sent By |
rnuquist |
Date |
2006-06-12 |
Time |
19:15 |
Rev Time |
0.00 |
Received By |
rnuquist |
Date |
2006-06-12 |
Time |
19:15 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-07-23 |
|
|
Cont ID |
|
Sent By |
jleahy |
Date |
2006-07-23 |
Time |
23:52 |
Rev Time |
0.45 |
Received By |
jleahy |
Date |
2006-07-23 |
Time |
23:52 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-06-13 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-06-13 |
Time |
14:11 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-06-13 |
Time |
13:47 |
Sent To |
P |
|
Notes |
2006-06-13 00:00:00 | | | NONCOMPLIANT | | | | PLEASE MAKE THE FOLLOWING CORRECTIONS | | FOR CODE COMPLIANCE AND RESUBMIT FOR | | REVIEW. | | | | 1} THE PERSON TAKING RESPONSIBILITY FOR | | THE DESIGN MUST PRINT AND SIGN THEIR | | NAME TO SAME PER 106.3.4.2.ALL SHEETS. | | | | 2} PER 110.9 AND 110.10: OBTAIN THE | | AVAILABLE FAULT CURRENT AT THE UTILITY | | AND CALCULATE THE SAME AT THE EQUIPMENT. | | INDICATE THE AIC RATING FOR THE | | EQUIPMENT IS EQUAL TO OR GREATER THAN | | THE AVAILABLE FAULT.THIS IS ALSO A | | REQUIREMENT OF THIS DEPARTMENT. | | | | 3} THERE IS A 150 AMP PANEL SHOWN ON ONE | | SHEET AND A 100 AMP METER ENCLOSURE ON | | ANOTHER SHEET. PLEASE LOCATE ALL SERVICE | | EQUIPMENT ON A SITE PLAN, METER | | ENCLOSURE, DISCONNECTS, PANELS,GENERATOR | | AND TRANSFER SWITCH, SO THAT COMPLIANCE | | WITH ARTICLES 225 AND 230 CAN BE | | REVIEWED. | | | | 4} PROVIDE SPEC'S FOR THE TRANSFER | | SWITCH. | | | | IF THERE ARE ANY QUESTIONS PLEASE CALL. | | | | WILLIAM R. TROBAUGH | | ELECTRICAL PLANS EXAMINER | | CITY OF WEST PALM BEACH | | CONSTRUCTION SERVICES DEPARTMENT | | 561) 805-6718 | | | | | | | | | | 4} |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2006-06-14 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-06-14 |
Time |
16:13 |
Rev Time |
0.15 |
Received By |
mperson |
Date |
2006-06-14 |
Time |
16:13 |
Sent To |
M |
|
Notes |
2006-06-14 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | BEFORE FINAL GEN/RES INSPECTION. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-07-19 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-19 |
Time |
13:23 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-19 |
Time |
13:23 |
Sent To |
E |
|
Notes |
2006-07-19 00:00:00 | TO "E" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-07-14 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-14 |
Time |
18:36 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-14 |
Time |
18:36 |
Sent To |
Z |
|
Notes |
2006-07-14 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-06-01 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-01 |
Time |
16:38 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-01 |
Time |
16:38 |
Sent To |
E |
|
Notes |
2006-06-01 00:00:00 | TO "GEN-RES" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-06-19 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-06-19 |
Time |
11:32 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2006-05-24 |
Time |
18:39 |
Sent To |
|
|
Notes |
2006-05-24 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
N |
Date |
2006-06-19 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-06-19 |
Time |
11:31 |
Rev Time |
0.10 |
Received By |
tgordon |
Date |
2006-06-19 |
Time |
11:31 |
Sent To |
|
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2006-06-14 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-06-14 |
Time |
16:12 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2006-06-14 |
Time |
16:12 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
P |
Date |
2006-07-18 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-07-18 |
Time |
17:14 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-07-18 |
Time |
17:14 |
Sent To |
I |
|
Notes |
2006-07-18 00:00:00 | PROVISO: THE PROPOSED GENERATOR SHALL | | NOT BE CLOSER THAN 7FT FROM THE REAR | | PROPERTY LINE.THE PROPOSED GENERATOR | | CANNOT PROJECT INTO THE 5FT UTILITY | | EASEMENT. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-05-27 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-05-27 |
Time |
21:11 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-05-27 |
Time |
21:11 |
Sent To |
I |
|
Notes |
2006-05-27 00:00:00 | DENIED, | | 1. MUST PROVIDE THE SIDE & REAR SETBACK | | OF THE PROPOSED GENERATOR FROM PROPETY | | LINE ON TWO CURRENT COPY OF SURVEY. | | | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|