Plan Review Details - Permit 06050754
Plan Review Stops For Permit 06050754
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-07-18 Cont ID  
Sent By alange Date 2006-07-18 Time 08:16 Rev Time 0.50
Received By alange Date 2006-07-18 Time 08:16 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-06-26 Cont ID  
Sent By alange Date 2006-06-26 Time 09:30 Rev Time 0.33
Received By alange Date 2006-06-26 Time 09:30 Sent To  
Notes
2006-06-26 00:00:00DENIED
  
 1.SUBMIT TWO ORIGONAL SIGNED AND
 SEALED SURVEYS, FS 472.025
  
 2.ALL PLANS SUBMITTED AFTER OCTOBER,
 1, 2005 SHALL BE DESIGNED TO THE 2004
 FLORIDA BUILDING CODE.
  
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-07-14 Cont ID  
Sent By btrobaug Date 2006-07-14 Time 10:36 Rev Time 0.33
Received By btrobaug Date 2006-07-14 Time 10:25 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status P Date 2006-06-05 Cont ID  
Sent By btrobaug Date 2006-07-14 Time 10:24 Rev Time 0.33
Received By btrobaug Date 2006-06-05 Time 07:15 Sent To P
Notes
***NONE***

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2006-07-14 Cont ID  
Sent By mperson Date 2006-07-14 Time 13:04 Rev Time 0.00
Received By mperson Date 2006-07-14 Time 13:04 Sent To B
Notes
2006-07-14 00:00:00NOTE: GAS PERMIT REQUIRED. GAS CONTRAC-
 TOR TO SUBMIT PLANS WITH PERMIT APPLICA-
 TION. ALL GAS INSPECTIONS TO BE COMPLETE
 BEFORE FINAL POOL INSPECTION.

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2006-06-06 Cont ID  
Sent By mperson Date 2006-06-06 Time 11:05 Rev Time 0.00
Received By mperson Date 2006-06-06 Time 11:05 Sent To B
Notes
2006-06-06 00:00:00NOTE: GAS PERMIT REQUIRED. GAS CONTRAC-
 TOR TO SUBMIT PLANS WITH PERMIT APPLICA-
 TION. ALL GAS INSPECTIONS TO BE COMPLETE
 BEFORE FINAL POOL INSPECTION.

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-07-08 Cont ID  
Sent By adarroug Date 2006-07-08 Time 17:38 Rev Time 0.00
Received By adarroug Date 2006-07-08 Time 17:38 Sent To E
Notes
2006-07-08 00:00:00TO "BTROBAUG" DESK--NEED STATUS REVIEW
 IN SYSTEM--PLANS ARE STAMPED FOR
 ELECTRICAL

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-06-26 Cont ID  
Sent By alange Date 2006-06-26 Time 09:31 Rev Time 0.00
Received By alange Date 2006-05-19 Time 16:32 Sent To  
Notes
2006-05-19 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-07-14 Cont ID  
Sent By mperson Date 2006-07-14 Time 13:01 Rev Time 0.33
Received By mperson Date 2006-07-14 Time 13:00 Sent To G
Notes
2006-07-14 00:00:00 
  
  
  
 ******PROVISO******
 1) COMPLY WITH FBC-2004 SEC 424.2, OR
 FBCR-2004 SEC R4101 PRIVATE SWIMMING
 POOLS.
 2) FBC-2004 SEC. 424.2.7.2, OR FBCR-2004
 SEC. R4101.7.2 PUMPS AND EQUIPMENT SHALL
 BE MOUNTED ON A SUBSTANTIAL BASE IN A
 MANNER THAT WILL ELIMINATE STRAIN ON
 PIPING.SLAB SHALL BE A NOMINAL 4"
 THICK.
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-06-06 Cont ID  
Sent By mperson Date 2006-06-06 Time 10:14 Rev Time 1.00
Received By mperson Date 2006-06-06 Time 10:14 Sent To G
Notes
2006-06-06 00:00:00******DENIED******
 REFERENCE: FBC-2004 SEC. 424.2 OR
 FBC-2004 RESIDENTIAL SEC R4101
  
 PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUBMITTALS TO REFLECT THE FOLLOWING
 INFORMATION REQUIRED FOR PLAN REVIEW:
  
 1) AS OF 10/1/05 FBC-2004 CODES WENT
 INTO EFFECT PLEASE CORRECTDRAWINGS TO
 REFLECT THE NEW CODE CHANGES FOR
 RESUBMITTAL.
 2) COMPLY WITH FBC-2004 SEC 424.2, OR
 FBCR-2004 SEC R4101 PRIVATE SWIMMING
 POOLS.(PLEASE ADD TO NOTES FOR
 RESUBMITTAL)
 3) FBC-2004 424.2.6.6.2, OR FBCR-2004
 SEC R4101.6.6.2 SHOW COMPLIANCE WITH
 ANSI/ASME A112.19.8M. PROVIDE MODEL
 NUMBER AND MANUF INFO FOR VAC LOCK.
 (GIVE DETAIL, SUBMITTAL OR ADD TO NOTES)
 4) FBC-2004 SEC. 424.2.7.2, OR FBCR-2004
 SEC. R4101.7.2 PUMPS AND EQUIPMENT SHALL
 BE MOUNTED ON A SUBSTANTIAL BASE IN A
 MANNER THAT WILL ELIMINATE STRAIN ON
 PIPING.SLAB SHALL BE A NOMINAL 4"
 THICK. (DETAIL REQUIRED)
 5) FBC-2004 SEC. 424.2.13.2, OR
 FBCR-2004 SEC.R4101.13.2 JOINTS AND
 CONNECTIONS, FBC PLMG SEC 605.21,(ADD
 TO NOTES)
 6) PLEASE ADD HEATER TO PIPING SCHEMATIC
 FOR RESUBMITTAL.
 7) FBC-2004 SEC. 424.2.14.1, OR
 FBCR-2004 SEC. R4101.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. (MANUFACTURE
 SHEETS REQUIRED, PLEASE SUBMIT)
 8) FBC-2004 SEC. 424.2.14.2, OR
 FBCR-2004 SEC. R4101.14.2 WATER
 RETENTION, PROVIDE A POSITIVE MEANS OF
 RETAINING WATER IN THE HEATER WHEN PUMP
 IS SHUT OFF.(MANUFACTURE SHEETS
 REQUIRED, PLEASE SUBMIT)
 9) FBC-2004 SEC. 424.2.14.4, OR
 FBCR-2004 SEC. R4101.14.4 CONNECTIONS,
 ALL WATER HEATING EQUIPMENT SHALL BE
 INSTALLED WITH FLANGES OR UNION
 CONNECTIONS ADJACENT TO THE HEATER.
 (ADD TO NOTES)
 10) FBC-2004 SEC. 424.2.14, OR FBCR-2004
 SEC. R4101.15 GAS PIPING SHALL COMPLY
 WITH FBC FUEL GAS.SEPARATE PLANS AND
 PERMIT REQUIRED.(ADD TO NOTES)
 11) FBC-2004 SEC. 13-612.1.ABC.2.3.3
 TIME CLOCKS SHALL BE INSTALLED ON
 PRIVATE POOLS.( PLEASE ADD TO DRAWING)
  
 **IN ORDER TO EXPIDITE PLAN REVIEW: WHEN
 RESUBMITTING, PLEASE REPLACE ONLY SHEETS
 WHICH HAVE CHANGED, PLEASE INCLUDE A
 TRANSMITTAL LETTER INDICATING HOW EACH
 ITEM WAS ADDRESSED AND PROVIDE ONE COPY
 OF ALL OLD/VOIDED SHEETS FOR REFERENCE
 ONLY.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  
  
  
  
  
  
  

Review Stop Z ZONING
Rev No 1 Status P Date 2006-06-01 Cont ID  
Sent By mmclean Date 2006-06-01 Time 11:56 Rev Time 0.00
Received By mmclean Date 2006-06-01 Time 11:56 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved