Plan Review Details - Permit 06050571
Plan Review Stops For Permit 06050571 |
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
P |
Date |
2006-10-16 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-10-16 |
Time |
08:49 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-10-16 |
Time |
08:49 |
Sent To |
PC |
|
Notes |
2006-10-16 08:52:26 | REVISION: ADD ADDITIONAL PIPING FOR A 50,000 BTU GAS | | GRILL. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2006-09-22 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-09-22 |
Time |
10:22 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-09-22 |
Time |
10:22 |
Sent To |
PC |
|
Notes |
2006-09-22 00:00:00 | REVISION: CHANGE FROM 12" W.C. TO A 2LB | | SYSTEM WITH REGULATORS SET AT ALL INLETS | | GOING TO THE INTERIOR AND AT POOL HEATER | | | | ******PROVISO****** | | 409.4 MP REGULATORS VALVES: A LISTED | | VALVE SHALL BE INSTALLED IMMEDIATELY | | AHEAD OF EACH MP REGULATOR. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2006-07-13 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-07-13 |
Time |
09:17 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-07-13 |
Time |
09:17 |
Sent To |
PC |
|
Notes |
2006-07-13 00:00:00 | NOTE: REFERENCE FIREPLACE PERMIT | | #05121184 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2006-05-19 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-05-19 |
Time |
14:25 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-05-19 |
Time |
14:25 |
Sent To |
PC |
|
Notes |
2006-05-19 00:00:00 | ******DENIED****** | | REFERENCE: FBC-2004 FUEL GAS | | | | THE FOLLOWING INFORMATION IS REQUIRED | | FOR PLAN REVIEW FOR A GAS PERMIT: | | | | 1. TYPE OF GAS, (LP OR NATURAL) THIS HAS | | TO BE INDICATED ON THE DRAWINGS. | | 2. BTU LOAD OF EACH APPLIANCE AND THE | | TOTAL BTU LOAD ON THE SYSTEM. REFER TO | | THE FBC-2004 FUEL GAS CODE SECS. 401.8 | | THRU 402.6.1 AND TABLES 402.4(1) THRU | | 402.4(33). | | 3. SHOW THE DISTANCE FROM THE POINT OF | | DELIVERY, (METER), TO THE MOST REMOTE | | OUTLET IN THE BUILDING AND/OR SYSTEM PER | | FBC-2004 FUEL GAS CODE APPENDIX A - USE | | OF CAPACITY TABLES A.3.1(4).(EXISTING | | SYSTEM MUST BE INDICATED ON DRAWING AND | | INDICATE THE POINT OF TIE IN FOR FIRE | | PLACE) | | 4. SUBMIT A DETAIL SHOWING THE TYPE, | | LOCATION, SIZE AND TERMINATION OF THE | | GAS VENTS PER FBC-2004 FUEL GAS CODE | | SECS. 502 THRU 505. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 | | | | | | | | |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-10-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-10 |
Time |
17:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-10 |
Time |
17:19 |
Sent To |
G |
|
Notes |
2006-10-10 17:20:06 | TO "G" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-09-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-15 |
Time |
10:02 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-15 |
Time |
10:02 |
Sent To |
G |
|
Notes |
2006-09-15 00:00:00 | TO "G" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-07-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-07 |
Time |
14:50 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-07 |
Time |
14:49 |
Sent To |
G |
|
Notes |
2006-07-07 00:00:00 | TO "G" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-05-19 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-05-19 |
Time |
14:38 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2006-05-16 |
Time |
14:56 |
Sent To |
|
|
Notes |
2006-05-16 00:00:00 | TO "G" BOX |
|
|
|