Plan Review Details - Permit 06050480
Plan Review Stops For Permit 06050480 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-05-31 |
|
|
Cont ID |
|
Sent By |
jwitmer |
Date |
2006-05-31 |
Time |
11:24 |
Rev Time |
2.22 |
Received By |
jwitmer |
Date |
2006-05-31 |
Time |
11:23 |
Sent To |
|
|
Notes |
2006-05-31 00:00:00 | BUILDING PLAN REVIEW | | PERMIT: 06050480 | | ADD: 1101 S FLAGLER DR BLDG "B" | | CONT: RALPH DELLA-PIETRA, INC. | | TEL: (561)745-8555 | | FL BLD CODE= 2004 FLORIDA BUILDING CODE | | * WEST PALM BEACH AMENDMENTS | | | | 1STREVIEW | | ACTION: DENIED | | | | 1) FL S S 713.13 | | NOTICE OF COMMENCEMENT, TO BE FILED | | WITH THE CLERK OF THE COURT BEFORE A | | PERMIT WILL BE ISSUED. NOTE: 713.13(2) | | IF THE WORK DESCRIBED IN THE NOTICE OF | | COMMENCEMENT IS NOT ACTUALLY COMMENCED | | WITHIN 90 DAYS AFTER THE RECORDING | | THEREOF, SUCH NOTICE IS NULL & VOID. | | | | 2) DISCREPANCY PERMIT APPLICATION | | DESCRIBES THE REMOVAL OF 5/8" CDX | | PLYWOOD AND ADDING 5/8" PLYWAOOD | | SHEATHING WHEREAS THE PLANS ONLY | | INDICATE "REMOVAL" OF PLYWOOD, NO | | MENTION OF REPLACEMENT, WHAT ABOUT SHEER | | WALLS? | | | | 3) SHEET A-3 IS MISSING INFORMATION ON | | WIRE LATH: | | 2510.3 INSTALLATION. | | INSTALLATION OF THESE MATERIALS SHALL BE | | IN COMPLIANCE WITH ASTM C 926 AND ASTM C | | 1063. | | A) TYPE OF LATH,& WEIGHT | | B) FASTENER& SPACING | | | | 4) DETAIL @ WINDOWS & DOORS. | | | | 5) A-3 DISCREPANCY, SOFFITS THERE ARE | | (2) NOTES ONE FOR 3/8" EXT GRADE PLYWOOD | | FOR SOFFIT THE OTHER IS TO REMOVE AND | | STUCCO SOFFIT. PROVIDE TYPE OF LATH FOR | | SOFFITS, (24" C/C)? | | BUILDING PLAN REVIEW | | JIM WITMER | | TEL: (561)805-6715 | | FAX: (561)659-8026 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-06-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-06-11 |
Time |
08:16 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-06-11 |
Time |
08:01 |
Sent To |
|
|
Notes |
2006-06-11 00:00:00 | *** UNSAT *** | | | | 1) NOTE: PLEASE SEE THE PERMIT | | APPLICATION(S) MENTIONS ELECTRICAL WORK | | BEING DONE AND IN SCOPE OF WORK. | | PLEASE PROVIDED DETAIL FOR AREA AND | | PROPOSED REMOVAL OF ELECTRICAL | | CONDUITS/LTS ETC. | | 215.5 | | THIS DETAIL CAN BE TYPICAL IF ALL | | BUILDINGS ARE THE SAME. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE TO CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | CITY OF WEST PALM BEACH | | CONSTUCTION SERVICES DEPT. | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
P |
Date |
2006-06-16 |
|
|
Cont ID |
|
Sent By |
mcarsill |
Date |
2006-06-16 |
Time |
11:27 |
Rev Time |
0.00 |
Received By |
mcarsill |
Date |
2006-06-16 |
Time |
11:27 |
Sent To |
|
|
Notes |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-06-26 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-06-26 |
Time |
09:47 |
Rev Time |
0.00 |
Received By |
tgordon |
Date |
2006-05-16 |
Time |
10:52 |
Sent To |
|
|
Notes |
2006-05-31 00:00:00 | TO "COMM" BD#21 | 2006-05-16 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2006-06-26 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-06-26 |
Time |
09:47 |
Rev Time |
0.02 |
Received By |
tgordon |
Date |
2006-06-26 |
Time |
09:47 |
Sent To |
|
|
Notes |
|
|
|
Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved |
 |
 |