Plan Review Details - Permit 06041091
Plan Review Stops For Permit 06041091
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-05-23 Cont ID  
Sent By alange Date 2006-05-23 Time 11:39 Rev Time 0.33
Received By alange Date 2006-05-23 Time 11:38 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-06-07 Cont ID  
Sent By btrobaug Date 2006-06-07 Time 12:40 Rev Time 0.50
Received By btrobaug Date 2006-06-07 Time 12:27 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-05-18 Cont ID  
Sent By btrobaug Date 2006-05-18 Time 12:37 Rev Time 0.50
Received By btrobaug Date 2006-05-18 Time 12:14 Sent To M
Notes
2006-05-18 00:00:00 
  
 DENIED
  
 PLEASE MAKE THE FOLLOWING CORRECTIONS
 FOR CODE COMPLIANCE AND RESUBMIT FOR
 REVIEW.
  
 THE VALUE ON THE APPLICATION MUST
 INCLUDE THE TOTAL COST OF LABOR AND
 MATERIAL FOR THE GENERATOR , EQUIPMENT
 (TRANSFER SWITCHES, PANELS ETC.)AND PAD
 PER 108.3 FBC AS AMMENDED.
  
 PLEASE SUBMIT A SITE PLAN AND LOCATE ALL
 THE SERVICE AND GENERATOR GEAR ON SAME
 SO THAT COMPLIANCE WITH
 230.72(GROUPING), 225.31-39 FOR THE
 DISCONNECTING MEANS REQUIREMENTS AND
 250.32 FOR GROUNDING CAN BE REVIEWED.
 225.36 SUITABLE FOR SERVICE EQUIPMENT.
  
 THE DISCONNECTING MEANS SPECIFIED IN
 225.31 SHALL BE SUITABLE FOR USE AS
 SERVICE EQUIPMENT.
  
 BILL TROBAUGH
 ELECTRICAL PLAN REVIEW
 561/805-6718
 [email protected]
  
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2006-05-19 Cont ID  
Sent By mperson Date 2006-05-19 Time 08:06 Rev Time 0.15
Received By mperson Date 2006-05-19 Time 08:06 Sent To B
Notes
2006-05-19 00:00:00NOTE: GAS PERMIT REQUIRED. GAS CONTRAC-
 TOR TO SUBMIT PLANS WITH PERMIT APPLICA-
 TION. ALL GAS INSPECTIONS TO BE COMPLETE
 BEFORE FINAL GEN/RES INSPECTION.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-05-26 Cont ID  
Sent By adarroug Date 2006-05-26 Time 12:15 Rev Time 0.00
Received By adarroug Date 2006-05-26 Time 12:15 Sent To E
Notes
2006-05-26 00:00:00TO "BTROBAUG" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-05-02 Cont ID  
Sent By adarroug Date 2006-05-02 Time 10:35 Rev Time 0.00
Received By adarroug Date 2006-05-02 Time 10:35 Sent To E
Notes
2006-05-02 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-05-23 Cont ID  
Sent By alange Date 2006-05-23 Time 11:39 Rev Time 0.00
Received By alange Date 2006-04-26 Time 12:06 Sent To  
Notes
2006-04-26 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status P Date 2006-05-18 Cont ID  
Sent By tgordon Date 2006-05-18 Time 16:21 Rev Time 0.20
Received By tgordon Date 2006-05-18 Time 16:21 Sent To P
Notes
2006-05-18 00:00:00*** PROVISO ***
 1) GENERATOR EXHUST MUST BE TEN FEET
 AWAY FROM ANY BUILDING OPENINGS
 (WINDOWS, DOORS, ROOF & EAVE VENTS), AND
 TEN FEET AWAY FROM ADJECENT BUILDING
 OPENS. PER 2004 FBC/M 401.5.1 .
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop P PLUMBING
Rev No 1 Status N Date 2006-05-19 Cont ID  
Sent By mperson Date 2006-05-19 Time 08:05 Rev Time 0.00
Received By mperson Date 2006-05-19 Time 08:05 Sent To G
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2006-04-30 Cont ID  
Sent By mmclean Date 2006-04-30 Time 17:35 Rev Time 0.00
Received By mmclean Date 2006-04-30 Time 17:35 Sent To I
Notes
2006-04-30 00:00:00NOTE: GENERATOR CAN ONLY ENCROACH 4FT
 INTO SETBACK.