Plan Review Details - Permit 06041025
Plan Review Stops For Permit 06041025 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-05-23 |
|
|
Cont ID |
|
Sent By |
shill |
Date |
2006-05-23 |
Time |
16:24 |
Rev Time |
0.00 |
Received By |
shill |
Date |
2006-05-18 |
Time |
08:53 |
Sent To |
|
|
Notes |
2006-05-23 00:00:00 | ****CORRECTIONS**** | | | | SAMANTHA HILL, BUILDING PLANS EXAMINER | | 561-805-6724 [email protected] | | | | FBCFLORIDA BUILDING CODE 2004 | | FBC EBFLORIDA BUILDING CODE 2004 | | EXISTING BUILDING CODE | | FBC*CITY OF WEST PALM BEACH | | AMENDMENTS TO THE FBC2004 | | | | 1.)A NOTICE OF COMMENCEMENT MUST BE | | FILED WITH THE CLERK OF COURTS BEFORE A | | PERMIT CAN BE ISSUED, FS713. | | | | 2.)THE PLANS ARE TO BE SIGNED, | | FAC61G1-16 (AS WELL AS PREVIOUS | | DISCUSSIONS WITH THE FLORIDA BOARD OF | | ARCHITECTS).IF YOU FEEL THAT A STAMP | | IS THE EQUIVALENT OF A SIGNATURE AND IS | | ACCEPTABLE, PLEASE PROVIDE A LETTER | | STATING SUCH AND IT WILL BE FORWARDED TO | | THE BOARD FOR THEIR OPINION.OTHERWISE, | | PLEASE SIGN ALL SHEETS (MICHAEL KYLE | | HART, AR01605). | | | | 3.)DECLARE THE LEVEL OF ALTERATION, | | FBC EB 301. | | | | 4.)CONSTRUCTION TYPE, A1.1 AND FIRE | | PROTECTION CRITERIA DECLARE TYPE II. | | THIS SHOULD BE TYPE IIA OR TYPE IIB, | | FBC6. | | | | 5.)ARCHITECTURAL KEYNOTES, A5.1 DO NOT | | INCLUDE 5 AND 6.CODE COMPLIANCE CANNOT | | BE DETERMINED AS SCOPE OF WORK IS NOT | | CLEAR. | | | | 6.)M0.1 REFERS TO INCORRECT BUILDING | | CODES.FOR EXAMPLE, FBC2003 IS NOT (AND | | NEVER WAS) THE GOVERNING CODE.CHECK | | ALL REFERENCES AND REVISE. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-05-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-05-17 |
Time |
19:58 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-05-17 |
Time |
19:51 |
Sent To |
|
|
Notes |
2006-05-17 00:00:00 | ***** UNSAT ****** | | | | 1) NOTE: PLEASE SEE BUIDLIGN REVIEW | | COMMENTS AS THE SCOPE OF WORK MAY BE | | REQUIRED TO BE UNDER A GC. | | PLEASE ALSO SEE AS THE MECHANICAL | | CONTRACTOR'S APPLICATION IS ATTACHED, | | THE VAULE FOR THE ENTIRE SCOPE OF WORK | | UNDER THE "PRIME PERMIT" SHALL BE | | INCLUSIVE OF ALL TRADES. | | FBC 108.3 | | | | 2) NOTE: PLEASE COORELATE ALL CODES ON | | ELECTRICAL SHEETS WITH THE CURRENT CODES | | REFLECTED ON THE ARCHITECTURAL SHEETS. | | PLEASE SEE CODES REF IE: SFBC 1997, 1999 | | NFPA-72, ETC. | | PLEASE ADJUST. | | | | 3) NOTE: PLEASE SEE BOTH MECHNICAL AND | | ELECTRICAL ENGINEERED SHEETS AS THE | | "SEALED", ARE NO LONGER IN USE OR | | ACCEPTABLE PER FAC 61G15-23.001. | | PLEASE KNOW, AS OF FEB 04, THE FBPE'S | | CHANGED SUCH RULING AS TO ADOPT THAT ALL | | SEALS SHALL NO LONGER CONTAIN THE | | WORDING "CERTIFICATE" AND ALL SEALS MUST | | CONTAIN THE WORDING OF "LICENSE". PLEASE | | KNOW, AN EXTENSION WAS GRANTED TO DEC | | 31ST, 2005, HOWEVER ALL PERMIT | | APPLICATIONS, PLANS AFTER SUCH DATE | | SHALL CONTAIN THE NEW UPDATED SEALS. | | | | | | PLEASE SEE ANY COMMENTS FROM OTHER | | TRADES. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE CALL. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2006-05-31 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-05-31 |
Time |
15:05 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-05-31 |
Time |
15:05 |
Sent To |
|
|
Notes |
2006-05-31 00:00:00 | ***DENIED*** | | | | 1) PLEASE NOTE THAT CODE REFERENCING IS | | INCONSISTENT THROUGHOUT PLANS. PLEASE BE | | SURE TO REFERENCE THE ADOPTED CODE AND | | CORRULATE ON ALL SHEETS. | | | | 2) SEPARATE SHOP DRAWINGS AND PERMIT | | REQUIRED FOR FIRE SPRINKLER REMODEL. | | SEPARATE PERMIT MAY BE REQUIRED FOR FIRE | | ALARM REMODEL DEPENDING ON THE AMOUNT OF | | DEVICES WITHIN THIS SCOPE OF WORK. | | | | 3) PLEASE PROVIDE FURTHER EXPLANATION | | REGARDING NOTE ON LIFE SAFETY PLAN THAT | | REFERENCES A FULLY SPRINKLERED | | AGREEMENT. | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-06-09 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-06 |
Time |
16:19 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-25 |
Time |
14:31 |
Sent To |
|
|
Notes |
2006-06-12 00:00:00 | 6/12/06-FROM "COMM" BD TO "P" BOX | 2006-05-11 00:00:00 | TO "COMM" BD#52 | 2006-04-25 00:00:00 | WAITING FOR "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-06-06 |
|
|
Cont ID |
|
Sent By |
hmoser |
Date |
2006-06-06 |
Time |
16:50 |
Rev Time |
0.00 |
Received By |
hmoser |
Date |
2006-06-06 |
Time |
16:50 |
Sent To |
|
|
Notes |
2006-06-06 00:00:00 | PLAN DENIED | | 1) PLANS NOT COMPLETE MISSING DUCT | | SIZE,EQUIPMENT SCHEDULE,FRESH AIR | | CALCULATIONS AND ENERGY CALCULATIONS | | 2) PLEASE SEE ELECTRICAL NOTE # 3 | | PLAN REVIEW BY HAROLD MOSER 561-805-6732 |
|
|
Review Stop |
MEDGAS |
MEDICAL GAS |
Rev No |
1 |
Status |
|
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
|
Time |
|
Rev Time |
0.00 |
Received By |
|
Date |
|
Time |
|
Sent To |
|
|
Notes |
|
|
|