Plan Review Stops For Permit 06040937 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
F |
Date |
2006-08-28 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-08-28 |
Time |
09:15 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-08-28 |
Time |
09:15 |
Sent To |
|
|
Notes |
2006-08-28 00:00:00 | DENIED | | | | INSUFFICIENT INFORMATION SUBMITTED FOR | | AN EXTERIOR WALL REVISION.PLANS | | REQUIRED. | | | | ART LANGE | | BUILDING PLANS EXAMINER | | 805-6672 |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2006-07-06 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-07-06 |
Time |
08:43 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-07-06 |
Time |
08:43 |
Sent To |
|
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
F |
Date |
2006-05-24 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-05-24 |
Time |
14:55 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-05-24 |
Time |
14:50 |
Sent To |
|
|
Notes |
2006-05-24 00:00:00 | DENIED | | | | | | 1. 713.13 F.S.A NOTICE OF COMMENCEMENT | | SHALL BE RECORDED AT PALM BEACH COUNTY | | COURTHOUSE AND A COPY SUBMITTED TO THIS | | OFFICE BEFORE A PERMIT CAN BE ISSUED. | | BLANK FORMS ARE AVAILABLE FROM THIS | | OFFICE. | | NOTE: THE NOTICE OF COMMENCEMENT MUST BE | | RE-RECORDED IF THE DESCRIBED IMPROVEMENT | | OR CONSTRUCTION IS NOT COMMENCED WITHIN | | 90 DAYS OF RECORDING. | | | | 2.PRODUCT APPROVALS REQUIRED FOR | | TRANSOM WINDOW. | | | | 3.ALL PRODUCT APPROVALS SUBMITTED WITH | | QUALITY ASSURANCE SHALL HAVE THE | | FOLLOWING STATE APPROVAL ATTACHED. | | | | PRODUCT APPROVALS SUBMITTED WITH | | PERMIT APPLICATION AFTER OCTOBER 1, 2003 | | ARE REQUIRED TO COMPLY WITH THE FLORIDA | | PRODUCT APPROVAL SYSTEM. FOR INFORMATION | | PLEASE SEE THE STATE WEBSITE AT | | WWW.FLORIDABUILDING.ORG. PRODUCTS WITH | | STATEWIDE APPROVAL ARE REQUIRED TO BE | | SUBMITTED WITH A STATE PRODUCT APPROVAL | | SHEETS THAT LISTS THE PRODUCT IDENTITY | | NUMBER FROM THE STATE. IF THE PRODUCT | | DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT | | AN APPLICATION FOR LOCAL PRODUCT | | APPROVAL OR SITE SPECIFIC FORM PER RULE | | 9B-72. SEE ATTACHMENT. | | WWW.FLORIDABUILDING.ORG | | | | 4.THOSE PRODUCT APPROVALS WHICH ARE | | REGULATED BY DCA RULE 9B-72 SHALL BE | | REVIEWED AND APPROVED IN WRITING BY THE | | DESIGNER OF RECORD PRIOR TO SUBMITTAL | | FOR JURISDICTIONAL APPROVAL.WPB | | AMENDMENT TO FBC 106.3.3. | | | | 5.A DESIGN PROFESSIONAL OR AN OWNER | | MUST ELECT ONE OR A COMBINATION OF | | LEVELS OF ALTERATION PURSUANT TO | | SECTIONS 303, 304 AND 305 OF THIS CODE. | | SHOW HOW PLANS WILL COMPLY WITH THE | | SECTION(S) SELECTED.2004 FBC EXISTING | | BUILDING 301.5 | | | | 6.SHOW AN ELEVATION OF RECEPTION | | COUNTER SO COMPLIANCE CAN BE CHECKED | | WITH 11-7.2 OF THE 2004 FBC. | | | | WHEN RESUBMITTING PLANS PLEASE INDICATE | | THE REVISION & REMOVE & REPLACE ANY | | PAGES AS NECESSARY. SUBMIT ONE COPY OF | | OLD PAGES FOR REFERENCE. A TRANSMITTAL | | LETTER LISTING THE ORIGINAL REVIEW | | COMMENT NUMBER, WITH A DESCRIPTION OF | | THE REVISION MADE, IDENTIFYING THE SHEET | | OR SPECIFICATION PAGE WHERE THE CHANGES | | CAN BE FOUND WILL HELP TO EXPEDITE YOUR | | PERMIT. THANK YOU FOR YOUR ANTICIPATED | | COOPERATION. | | | | ART LANGE | | CONSTRUCTION SERVICES DEPARTMENT | | BUILDING PLANS EXAMINER | | 561-805-6672 | | | | |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-06-28 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-06-28 |
Time |
18:29 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-06-28 |
Time |
18:08 |
Sent To |
|
|
Notes |
2006-06-28 00:00:00 | ** REDLINED** | | | | PLANS MENTIONS, 2005 NEC, WHEREAS WE ARE | | UNDER 2002. | | | | MISSING EQUIPMENT GROUNDING CONDUCTOR | | FROM MAINS TO SUB PANELS. |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-05-17 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-05-17 |
Time |
19:29 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-05-17 |
Time |
18:25 |
Sent To |
|
|
Notes |
2006-05-17 00:00:00 | ****** UNSAT ******* | | | | 1) NOTE: PLEASE SUBMIT PLANS DONE BY A | | MIN OF AN ARCHITECT PER FS 481.229 FOR | | VALUE AND SCOPE OF WORK OVER $25,000. | | | | 2) NOTE: PLEASE PROVIDE THE RISER | | DIAGRAM, AS PLANS SEEM TO SHOW TWO | | DIFFERENT METERS ??. THIS IS BEING SHOWN | | AS A SINGLE OCCUPANCY BUILDING AND NO | | "FIRE WALL" SEPARATION IS PRESENT ON | | PLANS. PLEASE KNOW, ONLY ONE SERVICE | | WILL BE PERMITTED AND ALL MAINS SHALL BE | | GROUPED. 230.2,230.70,230.72 | | | | 3) NOTE: PLEASE SEE 517 AND INDICATE | | LOCATIONS AND WIRING METHODS AS SET | | FORTH IN THE 2002 NEC AND LS CODE. | | PLEASE SEE ALL OTHER COMMENTS FROM OTHER | | TRADES WHICH MAY ALSO AFFECT THIS. | | | | 4)NOTE: PLEASE SEE 700.12E FOR | | CIRCUITING OF ALL EM/EXT LTS. | | | | 5) NOTE: PLEASE SEE THE MIN OCP AND AWG | | FOR EXISTING AHU'S SHALL BE ADJUSTED | | EVEN IF EXISITNG. PLEASE SEE | | 424.3B,240.4,310.16 10KW, #8 AND 50A | | OCP. | | | | 6) NOTE: PLEASE SUPPLY LOAD CALCUALTIONS | | PER 220.3,220.10,220.11,220.13 ETC. | | PLEASE SEE 215.3,230.42 FOR ALL | | CONTINUOUS LOADS TO BE SHOWN AT 125%. | | | | 7) NOTE: PLANS SHALL CONTAIN THE CURRENT | | CODES UNDER ADOPTION BY THE STATE OF | | FLORIDA. | | 2002 NFPA-70, 2003 NFPA-101, 2002 | | NFPA-72 ETC. | | | | 8) NOTE: PLEASE SEE BUIDLIGN REVIEW | | COMMENTS FOR REQUIRED "STATEMENT" ON | | PLANS FOR THE DESIGN PROFESSIONAL. | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
2 |
Status |
P |
Date |
2006-07-03 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-07-03 |
Time |
10:19 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-07-03 |
Time |
10:19 |
Sent To |
|
|
Notes |
|
|
Review Stop |
FIRE |
FIRE DEPARTMENT |
Rev No |
1 |
Status |
F |
Date |
2006-05-25 |
|
|
Cont ID |
|
Sent By |
mwennerg |
Date |
2006-05-25 |
Time |
15:27 |
Rev Time |
0.00 |
Received By |
mwennerg |
Date |
2006-05-25 |
Time |
15:27 |
Sent To |
|
|
Notes |
2006-05-25 00:00:00 | ***DENIED*** | | | | 1) PLANS SHOWS SMOKE ALARMS. IS THIS NEW | | OR EXISTING CONDITION? PLEASE INDICATE | | THE CODE REFERENCE BEING USED FOR | | ISTALLATION OF SMOKE ALARMS. | | | | 2) 2A-10B,C RATED FIRE EXTINGUISHER IS | | REQUIRED. | | | | 3) LIFE SAFETY SHALL COMPLY WITH NFPA | | 101, 2003 EDITION. | | | | 4) WHAT CONDITION EXISTS THAT WILL | | PREVENT THE CLOSET DOOR IF IN OPEN | | POSITION FROM NOT OBSTRUCTING MEANS OF | | EGRESS TO THE SECOND EXIT? | | | | | | MIKE WENNERGREN, CAPTAIN/WPBFR | | FIRE PLAN REVIEW (561) 805-6722 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-08-16 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-08-16 |
Time |
14:56 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-08-16 |
Time |
14:56 |
Sent To |
B |
|
Notes |
2006-08-16 00:00:00 | TO "ALANGE" DESK/SUBMITTAL |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-06-27 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-27 |
Time |
08:35 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-27 |
Time |
08:35 |
Sent To |
|
|
Notes |
2006-06-27 00:00:00 | TO "BOB"#4 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-05-30 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-30 |
Time |
08:34 |
Rev Time |
0.00 |
Received By |
rbrown |
Date |
2006-04-24 |
Time |
12:40 |
Sent To |
|
|
Notes |
2006-05-22 00:00:00 | MOVED TO "BOB"#16 | 2006-05-11 00:00:00 | TO "COMM" BD#22 | 2006-04-24 00:00:00 | WAITING ON "COMM" BD |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
P |
Date |
2006-05-30 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-05-30 |
Time |
14:46 |
Rev Time |
0.25 |
Received By |
tgordon |
Date |
2006-05-30 |
Time |
14:46 |
Sent To |
|
|
Notes |
2006-05-30 00:00:00 | *** PROVISO *** | | 1)BALANCED RETURN AIR. | | (A)TRANSFER DUCTS MAY ACHIEVE THIS BY | | INCREASING THE RETURN TRANSFER ONE AND | | ONE HALF TIMES THE CROSS SECTIONAL AREA | | (SQUARE INCHES) OF THE SUPPLY DUCT | | ENTERING THE ROOM OR SPACE IT'S SERVING | | AND THE DOOR HAVING AT LEAST AN | | UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE | | PROPER RETURN AIR BALANCE. PER 2004 | | FBC/R M1602.4 . | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2006-06-30 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2006-06-30 |
Time |
10:34 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2006-06-30 |
Time |
10:34 |
Sent To |
|
|
Notes |
2006-06-30 00:00:00 | RE SUB | | | | SHT. 6.1 PROVISO: | | | | 3) SHT 6.1 PLUMBING NOTES. #15 REFERENCE | | AIR CHAMBERS. TO COMPLY WITH ASSE 1010. | | SEE SEC 604.9 WATER HAMMER ARRESTORS. | | | | 4) SHT 3.1SHOW LOCATION OF WATER | | HEATER, PROVIDE A DETAIL TO SHOW | | COMPLIANCE OF SEC 604.7 FOR THERMAL | | EXPANSION. | | | | 5) SHT 6.1 WATER RISER. SEC 606.1 (4) | | LOCATION OF FULLY OPEN VALVES. | | SOV REQUIRED ON THE TOP OF EVERY WATER | | DOWN FEED PIPE. | | | | 6) SHT 6.1 WATER RISER, SHOW LOCATION OF | | BACK FLOW PREVENTER AS REQUIRED BY | | LOCAL ORDINANCE #2853-95 |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-05-27 |
|
|
Cont ID |
|
Sent By |
pschmitz |
Date |
2006-05-27 |
Time |
12:05 |
Rev Time |
0.00 |
Received By |
pschmitz |
Date |
2006-05-27 |
Time |
12:05 |
Sent To |
|
|
Notes |
2006-05-27 00:00:00 | PAUL SCHMITZ | | [email protected] | | FBC 2004 PLUMBING CODE PLAN REVIEW | | FBC2004 FUEL GAS CODEPLAN REVIEW | | FBC 2004 CH 11, FL ACESSIBILITY CODE | | AMENDMENTS TO THE FLORIDA BUILDING CODE, | | | | CHAPT.1, ADMINISTRATION, 2004 EDITION | | | | UNSAT | | | | 1)SEE OTHER PLAN REVIEW COMMENTS, | | THAT MAY EFFECT PLUMBING PLAN REVIEW. | | | | 2) SHT 3.1 LOUNGE SINK SEC 11-4.24 | | | | 11-4.24 SINKS. | | 11-4.24.1 GENERAL. | | SINKS REQUIRED TO BE ACCESSIBLE BY | | SECTION 11-4.1 SHALL COMPLY WITH SECTION | | 11-4.24. | | 11-4.24.2 HEIGHT. | | SINKS SHALL BE MOUNTED WITH THE COUNTER | | OR RIM NO HIGHER THAN 34 INCHES (865 MM) | | ABOVE THE FINISH FLOOR. | | 11-4.24.3 KNEE CLEARANCE. | | KNEE CLEARANCE THAT IS AT LEAST 27 | | INCHES (685 MM) HIGH, 30 INCHES (760 MM) | | WIDE, AND 19 INCHES (485 MM) DEEP SHALL | | BE PROVIDED UNDERNEATH SINKS. | | 11-4.24.4 DEPTH. | | EACH SINK SHALL BE A MAXIMUM OF 6? | | INCHES (165 MM) DEEP. | | 11-4.24.5 CLEAR FLOOR SPACE. | | A CLEAR FLOOR SPACE AT LEAST 30 INCHES | | BY 48 INCHES (760 MM BY 1219 MM) | | COMPLYING WITH SECTION 11-4.2.4 SHALL BE | | PROVIDED IN FRONT OF A SINK TO ALLOW | | FORWARD APPROACH. THE CLEAR FLOOR SPACE | | SHALL BE ON AN ACCESSIBLE ROUTE AND | | SHALL EXTEND A MAXIMUM OF 19 INCHES (485 | | MM) UNDERNEATH THE SINK (SEE FIGURE | | 11-32). | | 11-4.24.6 EXPOSED PIPES AND SURFACES. | | HOT WATER AND DRAIN PIPES EXPOSED UNDER | | SINKS SHALL BE INSULATED OR OTHERWISE | | CONFIGURED SO AS TO PROTECT AGAINST | | CONTACT. THERE SHALL BE NO SHARP OR | | ABRASIVE SURFACES UNDER SINKS. | | 11-4.24.7 FAUCETS. | | FAUCETS SHALL COMPLY WITH SECTION | | 11-4.27.4. LEVER-OPERATED, PUSH-TYPE, | | TOUCH-TYPE, OR ELECTRONICALLY CONTROLLED | | MECHANISMS ARE ACCEPTABLE DESIGNS. | | | | 3) SHT 6.1 PLUMBING NOTES. #15 REFERENCE | | AIR CHAMBERS. TO COMPLY WITH ASSE 1010. | | SEE SEC 604.9 WATER HAMMER ARRESTORS. | | | | 4) SHT 3.1SHOW LOCATION OF WATER | | HEATER, PROVIDE A DETAIL TO SHOW | | COMPLIANCE OF SEC 604.7 FOR THERMAL | | EXPANSION. | | | | 5) SHT 6.1 WATER RISER. SEC 606.1 (4) | | LOCATION OF FULLY OPEN VALVES. | | SOV REQUIRED ON THE TOP OF EVERY WATER | | DOWN FEED PIPE. | | | | 6) SHT 6.1 WATER RISER, SHOW LOCATION OF | | BACK FLOW PREVENTER AS REQUIRED BY | | LOCAL ORDINANCE #2853-95 | | | | END OF COMMENTS QUESTIONS 561- 805-6692 |
|
|