Plan Review Stops For Permit 06040904 |
Review Stop |
G |
GAS REVIEW |
Rev No |
5 |
Status |
P |
Date |
2006-12-14 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-12-14 |
Time |
13:44 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-12-14 |
Time |
13:44 |
Sent To |
PC |
|
Notes |
2006-12-14 13:49:17 | REVISION: ADD INTERIOR GAS LINES AND REGULATORS TO A | | WATER/HTR, DRYER AND RANGE. | | | | ****************PROVISO**************** | | IF DRYER ROOM IS A CONFINED SPACE, OPEN- | | INGS REQUIRED PER SECTION 304.5 OR | | SECTION 304.6 SHALL BE INSTALLED. | | MINIMUM 1,000 CUBIC FEET REQUIRED. | | | | IF WATER HEATER ROOM IS A CONFINED | | SPACE, OPENINGS REQUIRED PER SECTION | | 304.5 OR SECTION 304.6 SHALL BE | | INSTALLED. | | MINIMUM 1,750 CUBIC FEET REQUIRED. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
4 |
Status |
P |
Date |
2006-10-26 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-10-26 |
Time |
11:00 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-10-26 |
Time |
11:00 |
Sent To |
PC |
|
Notes |
2006-10-26 11:02:30 | REVISION: RUN 40' GAS LINE FROM 2LB METER TO 15KW GEN. |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
3 |
Status |
P |
Date |
2006-09-11 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-09-11 |
Time |
08:22 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-09-11 |
Time |
08:22 |
Sent To |
PC |
|
Notes |
2006-09-11 00:00:00 | REVISION: DELETE GAS PIPE TO TANKLESS | | WATER HEATER, DRYER, COOK TOP. GAS PIPE | | TO GENERATOR ONLY. | | REFERENCE: GEN/RES PERMIT #06040232 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
2 |
Status |
P |
Date |
2006-07-21 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-07-21 |
Time |
15:40 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-07-21 |
Time |
15:39 |
Sent To |
PC |
|
Notes |
2006-07-21 00:00:00 | REFERENCE" GEN/RES PERMIT #06040232 |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
F |
Date |
2006-04-25 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-04-25 |
Time |
09:35 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2006-04-25 |
Time |
09:35 |
Sent To |
PC |
|
Notes |
2006-04-25 00:00:00 | ******DENIED****** | | REFERENCE: FBC-2004 FUEL GAS | | | | THE FOLLOWING INFORMATION IS REQUIRED | | FOR PLAN REVIEW FOR A GAS PERMIT: | | | | 1. GAS PERMIT CAN NOT BE ISSUED UNTIL | | THE GEN/RES PERMIT APPLICATION #06040232 | | HAS BEEN APPROVED BY ZONING FOR THE | | GENERATOR LOCATION. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-12-12 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-12-12 |
Time |
15:25 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-12-12 |
Time |
15:25 |
Sent To |
G |
|
Notes |
2006-12-12 15:25:27 | TO "G" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-10-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-10-24 |
Time |
10:22 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-10-24 |
Time |
10:22 |
Sent To |
G |
|
Notes |
2006-10-24 10:22:34 | TO "G' BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-09-06 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-09-06 |
Time |
15:46 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-09-06 |
Time |
15:46 |
Sent To |
G |
|
Notes |
2006-09-06 00:00:00 | TO "G" BOX/REV |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-07-18 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-07-18 |
Time |
08:36 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-07-18 |
Time |
08:36 |
Sent To |
G |
|
Notes |
2006-07-18 00:00:00 | TO "G" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-04-25 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-04-25 |
Time |
09:56 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2006-04-20 |
Time |
16:53 |
Sent To |
|
|
Notes |
2006-04-20 00:00:00 | TO "G" BOX |
|
|