Plan Review Details - Permit 06040851
Plan Review Stops For Permit 06040851 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2006-05-11 |
|
|
Cont ID |
|
Sent By |
amorse |
Date |
2006-05-11 |
Time |
07:35 |
Rev Time |
0.50 |
Received By |
amorse |
Date |
2006-05-11 |
Time |
07:35 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2006-05-03 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-05-03 |
Time |
06:59 |
Rev Time |
0.25 |
Received By |
btrobaug |
Date |
2006-05-03 |
Time |
06:50 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2006-05-03 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-05-03 |
Time |
11:19 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2006-05-03 |
Time |
11:19 |
Sent To |
B |
|
Notes |
2006-05-03 00:00:00 | NOTE: NO GAS HEATER |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-05-25 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-25 |
Time |
14:21 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-25 |
Time |
14:21 |
Sent To |
P |
|
Notes |
2006-05-25 00:00:00 | TO "P" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-05-02 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-02 |
Time |
09:26 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-02 |
Time |
09:26 |
Sent To |
E |
|
Notes |
2006-05-02 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2006-05-11 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-21 |
Time |
16:12 |
Sent To |
|
|
Notes |
2006-04-21 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
P |
Date |
2006-05-30 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-05-30 |
Time |
11:57 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-05-30 |
Time |
11:57 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-05-03 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-05-03 |
Time |
10:40 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-05-03 |
Time |
10:40 |
Sent To |
G |
|
Notes |
2006-05-03 00:00:00 | ******DENIED****** | | REFERENCE: FBC-2004 424.2 SWIMMING POOLS | | | | PLEASE ADJUST YOUR NOTES, DETAILS, OR | | SUBMITTALS TO REFLECT THE FOLLOWING | | INFORMATION REQUIRED FOR PLAN REVIEW: | | | | 1. FBC-2004 SEC. 424.2.6.6 ENTRAPMENT | | PROTECTION FOR SUCTION INLETS. PLEASE | | SUBMIT AN ENGINEERED TABLE FOR "VENT | | PIPE MAXIMUM LENGTH" INDICATING PUMP | | SIZES, AVERAGE FLOW, AND MAXIMUM LENGTH | | OF 1" PVC VENT PIPE, FROM WHERE IT | | STARTS TO WHERE IT ENDS UP, COMPLYING | | WITH THREE SECOND RELEASE. | | | | 2. FBC-2001424.2.6.6.5 WHERE PROVIDED, | | THE VACUUM OR PRESSURE CLEANER FITTING | | SHALL BE LOCATED AT LEAST 6" AND NOT | | GREATER THAN 12" BELOW THE MINIMUM OPER- | | ATING WATER LEVEL OR AS AN ATTACHMENT TO | | THE SKIMMER. ( NEED MANUFACTURE CUT | | SHEET OF VACUUM OR PRESSURE CLEANING | | FITTING OR ADD MAKE AND MODEL NUMBER TO | | PRINT) | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2006-04-29 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-04-29 |
Time |
13:48 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-04-29 |
Time |
13:48 |
Sent To |
I |
|
Notes |
2006-04-29 00:00:00 | NO DECK. POOL EQUIPMENT CAN ONLY | | ENCROACH 4FT INTO A SETBACK. |
|
|
|