Plan Review Details - Permit 06040626
Plan Review Stops For Permit 06040626
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2006-10-27 Cont ID  
Sent By alange Date 2006-10-27 Time 08:48 Rev Time 0.00
Received By alange Date 2006-10-27 Time 08:47 Sent To  
Notes
2006-10-27 08:48:13STRUCTURAL PAGES REVIEWED

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2006-09-25 Cont ID  
Sent By lmartine Date 2006-09-25 Time 15:24 Rev Time 0.00
Received By lmartine Date 2006-09-25 Time 15:24 Sent To  
Notes
2006-09-25 00:00:00RESTAMP STRUCTURAL SHEETS

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2006-09-08 Cont ID  
Sent By alange Date 2006-09-08 Time 08:08 Rev Time 1.00
Received By alange Date 2006-09-08 Time 08:08 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-08-22 Cont ID  
Sent By alange Date 2006-08-22 Time 09:35 Rev Time 1.00
Received By alange Date 2006-08-22 Time 09:35 Sent To  
Notes
2006-08-22 00:00:00DENIED
  
 THE IMPACT FEES PAID ARE SHOWN FOR AN
 ADDITIONAL 297 SQ. FT..PLANS SHOW NEW
 SQUARE FOOTAGE OF 2511 SQ.FT.
 HAVE PLANS RESTAMPED WITH CORRECT FEES
 PAID.
  
 ART LANGE
 BUILDING PLANS EXAMINER
 805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-07-11 Cont ID  
Sent By alange Date 2006-07-11 Time 09:36 Rev Time 0.00
Received By alange Date 2006-07-11 Time 09:36 Sent To  
Notes
2006-07-11 00:00:00DENIED
  
  
 4.SIGN OWNER AGENT ON ENERGY CALCS.
  
 7.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 8.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER 2004 FBC R-802.10.1
 REQUIRED PRIOR TO INSTALLATION.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-05-18 Cont ID  
Sent By alange Date 2006-05-18 Time 14:25 Rev Time 2.50
Received By alange Date 2006-05-18 Time 14:25 Sent To  
Notes
2006-05-18 00:00:00DENIED
  
  
 1. 713.13 F.S.A NOTICE OF COMMENCEMENT
 SHALL BE RECORDED AT PALM BEACH COUNTY
 COURTHOUSE AND A COPY SUBMITTED TO THIS
 OFFICE BEFORE A PERMIT CAN BE ISSUED.
 BLANK FORMS ARE AVAILABLE FROM THIS
 OFFICE.
 NOTE: THE NOTICE OF COMMENCEMENT MUST BE
 RE-RECORDED IF THE DESCRIBED IMPROVEMENT
 OR CONSTRUCTION IS NOT COMMENCED WITHIN
 90 DAYS OF RECORDING.
  
 2.BEFORE A PERMIT TO CONSTRUCT, MAY BE
 ISSUED, IMPACT FEES MUST BE PAID TO PALM
 BEACH COUNTY. THE ACTUAL PERMIT
 SET OF PLANS MUST BE STAMPED BY THAT
 OFFICE, AND A COPY OF THE PAID RECEIPT
 ATTACHED TO THE PERMIT APPLICATION.
 PLEASE CALL (561)233-5025 FOR MORE
 INFORMATION.
  
 3.BASED ON ICC BUILDING VALUATION DATA
 THE PERMIT VALUE IS TOO LOW.REVISE
 PERMIT VALUE TO INCLUED ALL WORK AND PAY
 ADDITIONAL PERMIT FEES.
  
 4.SUBMIT TWO COPIES OF ENERGY CALCS
 PER 2004 FBC.
  
 5.PRODUCT APPROVALS REQUIRED FOR
 EXTERIOR DOORS, WINDOWS AND IMPACT
 PROTECTION.
  
 6.ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 7.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 8.SUBMIT TWO SETS OF TRUSS DRAWINGS
 FOR REVIEW PER 2004 FBC R-802.10.1
  
 9.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 10.SUBMIT PLANS FOR NEW OFFICES.
  
 11.SHOW EXISTING AND NEW SQUARE
 FOOTAGE CALCUALATIONS FOR ALL AREAS.
  
 12.SHOW SIZE AND LOCATION OF ATTIC
 ACCESS COMPLYING WITH FBC 2004 R 807.1
  
 13.SQUARE FOOTAGE NOT SHOWN ON
 APPLICATION.APPLICATION DOES NOT
 REFLECT WORK THAT IS SHOWN ON PLANS.
  
 14.BUILDING IS IN AN AREA OF
 QUESTIONABLE SOILS. SUBMIT A SOILS
 REPORT WITH FOOTING RECOMMENDATIONS.
  
 15.SUBMIT AN ELEVATION CERTIFICATE
 SHOWING FINISH FLOOR HEIGHT.FINISH
 FLOOR HEIGHT IN THIS AREA IS 6" ABOVE
 THE BASE ELEVATION OF 7FT.SHOW FINISH
 FLOOR HEIGHT ON PLANS.
  
 16.SHOW GUARDRAIL DETAILS COMPLYING
 WITH 2004 FBC R-312.1 AND R-312.2
  
 17.SUBMIT TWO ORIGONAL SIGNED AND
 SEALED SURVEYS. FS 472.025
  
 18.SHOW BUILDING ELEVATIONS ON PLANS.
  
 19.SHOW CROSS SECTIONS FROM FOUNDATION
 UP THROUGH ROOF.
  
 20.PS-1 CALLS FOR 5/8" ROOF SHEATHING
 AND OTHER AREAS ON PLAN SPEC FOR 3/4"
 SHEATHING.
  
 21.INSUFFICIENT INFORMATION PROVIDED
 FOR A COMPLETE REVIEW. SEE WPB
 AMMENDMENTS TO THE FBC 106.3.5.1.1 FOR
 MINIMUM PLAN REVIEW CRITERIA FOR
 BUILDINGS.ADDITIONAL COMMENTS MAY
 ARISE AT THE NEXT PLAN REVIEW.
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-09-07 Cont ID  
Sent By dpalmer Date 2006-09-07 Time 12:55 Rev Time 0.00
Received By dpalmer Date 2006-09-07 Time 12:49 Sent To B
Notes
2006-09-07 00:00:00REDLINED FOOTER STEEL AT MAIN HOUSE
 INSTEAD OF BLDG STEEL. BLDG STEEL
 REQUIRED OF PRESENT.
 250.50
  
 NO NEED FOR REVISIONS.

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-08-04 Cont ID  
Sent By dpalmer Date 2006-08-04 Time 15:39 Rev Time 0.00
Received By dpalmer Date 2006-08-04 Time 11:25 Sent To M
Notes
2006-08-04 00:00:00****** UNSAT2ND REVIEW ********
  
 ** PLEASE SEE SOME OF THE NOTES FROM
 PREVIOUS REVIEW STILL NEED TO BE
 ADDRESSED.
 PLEASE ALSO SEE NEW COMMENT FOR HAND
 WRITTEN ITEMS ON PLANS.
  
 1) NOTE:NO , PLEASE SEE ALL OLD/VOIDED
 SHEETS WERE LEFT IN SETS WHEN REQUESTED
 TO BE REMOVED.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE BE SURE TO COMPLETELY
 REMOVED ANY OF THE OLD/VOIDED SHEETS
 FROM SETS AND ONLY INSERT THE NEW
 REVISED SHEETS INTO COMPLETE SETS FOR
 REVIEW AND STAMPING.
 THIS WILL HELP TO AVOID ANY DELAYS IN
 PROCESSING PROJECT.
 ** ONE COPY OF ANY OLD/VOIDED REMOVED
 SHEETS SHOULD BE SUBMITTED SEPARATELY
 FOR REFERENCE.
  
 2) NOTE: OK.
  
 3) NOTE:NO, NOTE MENTIONS ALL ADOPTED
 CODES, HOWEVER PLEASE SEE THAT THE CODES
 RELEVANT TO DESIGN SHALL BE SPECIFIC AND
 ON PLANS.PLEASE SEE MIN CODES WHICH WERE
 GIVEN BELOW TO BE STATED ON ELECTRICAL
 PLANS.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEE PLANS SHALL
 REFERENCE THE CURRENT CODES IN EFFECT.
 PLEASE SEE PLANS NOW INDICATE THE
 "LATEST CODES". WE ARE NOT CURRENTLY
 UNDER THE LATEST CODES AS THEY HAVE NOT
 YET BEEN ADOPTED BY THE STATE OF
 FLORIDA.
 PLEASE SEE THE FOLLOWING AT A MIN SHOULD
 BEON PLANS. 2002 NFPA-70, 2003 NFPA-101,
 2002 NFPA-72.
  
 4) NOTE: OK.
  
 5) NOTE: OK.
  
 6) NOTE: OK. SEE NEW NOTES.
  
 8) NOTE: NO? PLEASE SEE LOAD
 CALCULATIONS MENTIONS A LOAD FOR PANEL
 "C" HOWEVER HOW AND WHERE ARE LOADS
 DERIVED. PLEASE SEE AS NOTED ON PREVIOUS
 NOTE, PLEASE INDICATE THE LOADS(DRYER,
 WASHER, SM APPLIANCE CIRCUITS, ETC
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEE LOAD CALCULATIONS
 SHALL INCLUDE ALL LOADS ON EXISTING
 PANEL "C" AS THIS EXISTING PANEL "C" IS
 BEING FED FROM NEW 225A MAIN, YET LOAD
 CALCULATIONS ON SHOW NEW HOUSE PANEL
 LOADS.
 215.5,220.31B. UNABLE TO VERIFY MANY
 ITEMS FROM EXISTING PANEL AND LOADS AT
 THIS TIME. PLEASE SEE NEC FOR MIN LOADS
 REQUIRED FOR DRYER AND WASHER/LAUNDRY.
 220.18, 220.16 ETC.
  
 9) NOTE: NO, PLEASE SEE ROOM WHICH IS
 BEING IDENTIFIED AT "PANTRY" A RECEPT
 WAS REDLINED FOR WALL SPACE AS THIS IS
 BEING SHOWN AS A ROOM. IF THIS IS A
 "HALL" THEN ADJUST ACCORDINGLY.
 PLEASE SEE BEDRM UPSTAIRS AS PREVIOUS
 PLANS WERE REDLINED FOR MORE THAN 2' OF
 WALL IN BEDRM #1
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEEPLEASE SEE MISSING RECEPTS
 PER
 210.52
  
 10) NOTE:NO, PLEASE SEE PREVIOUS PLANS
 WERE REDLINE WHERE THIS WOULD BE
 REQUIRED. PLEASE SEE COUNTER IS OVER 8'
 WHICH WOULD REQUIRE 3 COUNTER SPACE
 RECEPTS.
 PLEASE SEE THE THIRD RECEPT SHOWN IS FOR
 THE DISPOSAL.
 PLEASE SEE PLANS ARE REDLINED ONCE AGAIN
 AT THAT LOCATION.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEE MISSING GFI RECEPT
 ALONG KITCHEN COUNTER SPACE PER
 210.52C1,210.8A6.
  
 11) NOTE:OK/NO, WATER HEATER IS NOW
 BEING SHOWN W/ 2500W HEAT, HOWEVER CAN
 NOT VERIFY THE LOAD AS THIS IS NOT
 PLACED IN LOAD CALCULATIONS.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE CLARIFY WATER HEATER,
 NEW , EXISTING ETC. NOWATER HEATER IS
 SHOWN ON ELECTRICAL PLANS. THIS IS SHOWN
 ON "P" SHEETS, HOWEVER THE LOAD SHALL
 ALSO BE INCLUDED WITH LOAD CALCULATIONS
 FOR SERVICE.
 215.5, 220.31B
  
 12) NOTE: OK.
  
 13) NOTE: OK.
  
 14) NOTE: OK.
  
 15) NOTE: OK.
  
 16)NOTE:NO, ONLY SHOWN FOR PANELS.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
  
 17) NOTE: NO, THIS IS THE SAME.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE SEE RISER IS SHOWING
 "EQUIPMENT GROUNDING CONDUCTORS" FROM
 METER TO MAINS. PLEASE SEE THE EQP GRNDS
 ARE ONLY INSTALLED AFTER THE FIRST MEANS
 OF DISCONNECT.
 250.6,250.24B
  
 18) NOTE: OK.
  
 19) NOTE: STILL SHOWING THE FOOTER STEEL
 AT EXISTING GUEST HOUSE? THIS IS OK.
  
 **PREVIOUS REVIEW NOTE **
 PLEASE SEE GROUNDING ELECTRODE
 RISER AT GUEST HOUSE WHICH INDICATES
 FOOTER STEEL? PLEASE KNOW, AS AN
 EXSITING BUILDING, THIS IS NOT REQUIRED
 AT GUEST HOUSE , ONLY MAIN HOUSE. PLEASE
 KNOW, THE STRUCTURAL INTEGRITY OF THE
 EXISTING FOOTER MAY BE COMPOMISED TO
 ATTACH. PLEASE KNOW, GIVEN THE AGE OF
 THE EXISTING FOOTER IN THIS GUEST HOUSE,
 FOOTER STEEL MAY NOT BE PRESENT AT
 ALL.??
 THIS IS FOR INFORMATION ONLY AS, IT MAY
 BE DONE, BUT NOT REQUIRED AT GUEST
 HOUSE.
  
 20) NOTE:NO, PLEASE SEE A NOTE WAS
 ADDED TO ONLY ONE.
  
 ** PREVIOUS REVIEW NOTE**
 PLEASE SEE DISCONNECT AND AHU
 IN CLOSETS SEEMS TO BE LOCATED
 NOT TO MEET 110.26 AND THE MECHANICAL
 CODE.
 PLEASE ALSO SEE 240.24D AS OCP IS NOT
 PERMITTED IN A CLOTHES/STORAGE CLOSET.
 PLEASE SEE THIS LOCATION AND THE CLOSE
 PROXIMITY TO EASILY IGNITIBLE MATERIALS.
  
 21) NOTE: OK.
  
 22) NOTE: OK.
  
 23) NOTE:NO, PLEASE SEE OCP ON SOME
 UNITS ON PANEL SCHEDULE EXCEED THE MAX
 OCP RATING AS STATED ON MECH PLANS>
 PLEASE ADJUST AND CORRELATE.
  
 ** PREVIOUS REVIEW NOTE **
 PLEASE CORRLELATE ALL A/C
 SYSTEMS, OCP AND LOADS, AS THESE SHOWN
 ON ELECTRICAL PANEL SCHEDULE DO NOT
 MATCH WITH THOSE AS SHOWN ON MECH
 SHEETS.
  
 24) NOTE:SAME, IF SHOWN THIS WAY OK,
 HOWEVER SIZE WILL BE REQUIRED TO BE
 REVISED.
  
 ** PREVIOUS NOTE **
 PLEASE VERIFY THE SIZE OF THE
 NEW METER CAN BEING SHOWN AS 225A?? THIS
 IS NOT KNOWN AS A COMMON SIZE. PLEASE
 ADJUST.
 215.5
  
 **** NEW NOTES ****
  
 25) NOTE: PLEASE SEE NO HAND WRITTEN
 CHANGES CAN BE MADE TO PLANS WHICH ARE
 SIGNED , DATED AND SEALED BY THE
 ENGINEER. IF ANY CHANGES ARE MADE BY
 HAND, EACH AND EVERY ITEM SHALL CONTAIN
 INITIALS OF SAID DESIGNER AND DATE.
 FS 471.025, FAC 61G15-23.002
  
 26) NOTE: PLEASE SEE NOTICE GIVEN FOR
 FS553.80(2)9B).
 THIS IS ONLY A NOTICE.
  
 ** PLEASE KNOW,MANY OF THE ABOVE ITEMS
 ARE REDLINED ON ONE OF THE SETS OF
 PLANS, HOWEVER IS IN NO WAY ALL
 LOCATIONS AS NOTED ABOVE.
  
 ** PLEASE SUBMIT THE ABOVE FOR REVIEW
 AND IF THERE ARE ANY QUESTIONS OR
 COMMENTS, PLEASE DO NOT HESITATE IN
 CONTACTING THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  
  
  
  
  

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-06-25 Cont ID  
Sent By dpalmer Date 2006-06-25 Time 16:52 Rev Time 0.00
Received By dpalmer Date 2006-06-25 Time 15:47 Sent To P
Notes
2006-06-25 00:00:00****** UNSAT ********
  
 1) NOTE: PLEASE BE SURE TO COMPLETELY
 REMOVED ANY OF THE OLD/VOIDED SHEETS
 FROM SETS AND ONLY INSERT THE NEW
 REVISED SHEETS INTO COMPLETE SETS FOR
 REVIEW AND STAMPING.
 THIS WILL HELP TO AVOID ANY DELAYS IN
 PROCESSING PROJECT.
 ** ONE COPY OF ANY OLD/VOIDED REMOVED
 SHEETS SHOULD BE SUBMITTED SEPARATELY
 FOR REFERENCE.
  
 2) NOTE: PLEASE SEE CIRCUITING FOR BATH
 RECEPT ON FIRST FLR IS CIRCUITED TO
 ELEVATOR LTS. PLEASE SEE
 210.52D,210.11C3. BATH(S) REQUIRE
 DEDICATED CIRCUITS AS SET FORTH IN CODES
 REF.
  
 3) NOTE: PLEASE SEE PLANS SHALL
 REFERENCE THE CURRENT CODES IN EFFECT.
 PLEASE SEE PLANS NOW INDICATE THE
 "LATEST CODES". WE ARE NOT CURRENTLY
 UNDER THE LATEST CODES AS THEY HAVE NOT
 YET BEEN ADOPTED BY THE STATE OF
 FLORIDA.
 PLEASE SEE THE FOLLOWING AT A MIN SHOULD
 BEON PLANS. 2002 NFPA-70, 2003 NFPA-101,
 2002 NFPA-72.
  
 4) NOTE: PLEASE SEE THE DISCONNECTING
 MEANS AT MAIN HOUSE SHOULD BE LOCATED AT
 THE NEAREST POINT OF ENTRANCE TO THE
 DWELLING. 225.31-225.34
  
 5) NOTE: PLEASE SEE MISSING EGRESS
 LIGHTING CONTROLS IN MANY LOCATIONS.
 PLEASE SEE ALL RMS IN HOUSE WHICH
 INDICATE A SW FOR A FAN AND A
 FAN J-BOX ONLY??
 PLEASE KNOW, A LT FIXTURE WILL BE
 REQUIRED OR 1/2 SWITCHED RECEPT.
 PLEASE SEE OTHER LOCATIONS IN MAIN HOUSE
 FOR LOCATIONS OF MEANS OF EGRESS AND
 WHERE A LT FIXTURE OF SOME SORT WILL BE
 REQUIRED.
 PLEASE SEE KITCHEN EGRESS FROM
 BREAKFAST/PANTRY AREAS?
 210.70, LS 101 7.8, RESIDENTIAL CHAPTER
 24.
  
 6) NOTE: PLEASE SEE SD'S ARE NOTALL
 SHOWN WITH CIRCUITING? PLEASE SEE ONE SD
 IS CIRCUITED HOWEVER THIS IS BEING SHOWN
 CIRCUITED TO ONE PHASE OF THE ELEVATOR
 MOTOR WHICH IS NOT PERMITTED. PLEASE
 KNOW, THE SD'S IN DWELLING CAN BE
 CIRCUITED TO ONE OF THE ARC FAULT
 PROTECTED BEDRM LIGHTING/RECEPT
 CIRCUITS. THIS WILL ALLEAVIATE THE
 TURNING OFF OF THIS CIRCUIT AND LEAVING
 THE ENTIRE DWELLING WITH OUT SD
 PROTECTION. ( THIS WOULD ALSO ALLEAVIATE
 THE ADDITIONAL AFCI BRKR)
 215.5 NFPA-72 11.8.3
 ** PLEASE SEE 11.8.3 AS STATED ABOVE,
 MISSING SD WHICH IS REQUIRED INSIDE ALL
 SLEEPING ROOMS, WHICH INLCUDE NEW MASTER
 BEDRM. PLEASE KNOW, THE SD SHALL BE
 INSTALLED WITH IN 3' OF THE PEAK ON A
 SLOPED CEILING.
 PLEASE SEE SD'S WILL ALSO BE REQUIRED
 INSIDE AND OUTSIDE OFFICE AS THIS ROOM
 IS CONSIDERED AN ADAPTABLE SLEEPING RM
 7) NOTE: PLEASE CLARIFY LOAD SHOWN FOR
 RANGE AS ONLY 5KW. THIS SEEMS VERY LOW
 FOR A RANGE.
 215.5
  
 8) NOTE:PLEASE SEE LOAD CALCULATIONS
 SHALL INCLUDE ALL LOADS ON EXISTING
 PANEL "C" AS THIS EXISTING PANEL "C" IS
 BEING FED FROM NEW 225A MAIN, YET LOAD
 CALCULATIONS ON SHOW NEW HOUSE PANEL
 LOADS.
 215.5,220.31B. UNABLE TO VERIFY MANY
 ITEMS FROM EXISTING PANEL AND LOADS AT
 THIS TIME. PLEASE SEE NEC FOR MIN LOADS
 REQUIRED FOR DRYER AND WASHER/LAUNDRY.
 220.18, 220.16 ETC.
  
 9) NOTE: PLEASE SEE MISSING RECEPTS PER
 210.52
  
 10) NOTE: PLEASE SEE MISSING GFI RECEPT
 ALONG KITCHEN COUNTER SPACE PER
 210.52C1,210.8A6.
  
 11) NOTE: PLEASE CLARIFY WATER HEATER,
 NEW , EXISTING ETC. NOWATER HEATER IS
 SHOWN ON ELECTRICAL PLANS. THIS IS SHOWN
 ON "P" SHEETS, HOWEVER THE LOAD SHALL
 ALSO BE INCLUDED WITH LOAD CALCULATIONS
 FOR SERVICE.
 215.5, 220.31B
  
 12) NOTE: PLEASE SEE 408.4 WHERE THE
 PANEL SCHEDULE SHALL BE SPECIFIC FOR
 ROOMS AND ALL AREAS. MOST ARE DONE.
 IE: BEDRM #3 RECEPTS , LIV RM LTS ETC
 ** IT IS KNOWN, THAT DURING CONSTRUCTION
 THESE CIRCUITS MAY CHANGE AND CAN BE
 REVISED AT A LATER DATE.
  
 13) NOTE: PLEASE SEE PLANS INDICATE A
 "SITTING ROOM", HOWEVER THIS SEEMS TO BE
 OUTSIDE SPACE? IF THIS IS A HABITABLE
 ROOM, THEN RECEPT SPACING SHALL MEET
 210.52
  
 14) NOTE: PLEASE SHOW THE LOCATION OF
 THE PANEL "B" ON 2ND FR. NOT LOCATED ON
 PLANS AT THIS TIME. PLEASE BE SURE TO
 SEE 408.7, 240.24D, 110.26 BEFORE
 PLACING PANEL.
  
 15) NOTE: PLEASE CORRELATE FEEDERS TO
 PANEL "B" AS RISER SHOWS ONE SIZE AND
 PANEL SCHEDULE "A" SHOWS ANOTHER.
 215.5, 310.16
  
 16)NOTE: PLEASE SUBMIT AIC RATINGS FOR
 ALL NEW SERVICE EQUIPMENT BEING INSTALL-
 ED. MAINS/BRKRS AND PANELS ARE ALL TO BE
 RATED FOR THE AVAILABLE FAULT CURRENT.
 PER 110.9/215.5
  
 17) NOTE: PLEASE SEE RISER IS SHOWING
 "EQUIPMENT GROUNDING CONDUCTORS" FROM
 METER TO MAINS. PLEASE SEE THE EQP GRNDS
 ARE ONLY INSTALLED AFTER THE FIRST MEANS
 OF DISCONNECT.
 250.6,250.24B
  
 18) NOTE: PLEASE SEE 250.50, 250.32 FOR
 MIN GROUNDING ELECTRODE SYSTEM AT MAIN
 HOUSE. NEW FOOTER STEEL, CWP, GRND ROD
 WILL BE REQUIRED AT MAIN HOUSE. THIS IS
 NOT CONSIDERED AS ONE BUILDING PER FBC
 DEFINITIONS.
  
 19) NOTE: PLEASE SEE GROUNDING ELECTRODE
 RISER AT GUEST HOUSE WHICH INDICATES
 FOOTER STEEL? PLEASE KNOW, AS AN
 EXSITING BUILDING, THIS IS NOT REQUIRED
 AT GUEST HOUSE , ONLY MAIN HOUSE. PLEASE
 KNOW, THE STRUCTURAL INTEGRITY OF THE
 EXISTING FOOTER MAY BE COMPOMISED TO
 ATTACH. PLEASE KNOW, GIVEN THE AGE OF
 THE EXISTING FOOTER IN THIS GUEST HOUSE,
 FOOTER STEEL MAY NOT BE PRESENT AT
 ALL.??
 THIS IS FOR INFORMATION ONLY AS, IT MAY
 BE DONE, BUT NOT REQUIRED AT GUEST
 HOUSE.
  
 20) NOTE: PLEASE SEE DISCONNECT AND AHU
 IN CLOSETS SEEMS TO BE LOCATED
 NOT TO MEET 110.26 AND THE MECHANICAL
 CODE.
 PLEASE ALSO SEE 240.24D AS OCP IS NOT
 PERMITTED IN A CLOTHES/STORAGE CLOSET.
 PLEASE SEE THIS LOCATION AND THE CLOSE
 PROXIMITY TO EASILY IGNITIBLE MATERIALS.
  
 21) NOTE: PLEASE SEE PLANS INDICATE TWO
 EXISTING PANELS AT GUEST HOUSE AND ONLY
 ONE SHOWN ON RISER.?
 PLEASE CORRELATE. 215.5
  
 22) NOTE: PLEASE GO THROUGH ALL SWITCHES
 ON PLANS AS SOME ARE SHOWN, BUT NOT
 GOING TO ANYTHING, OTHERS SHOULD BE
 3-WAY, BUT NOT CLEAR? SEE NOTE ABOVE.
  
 23) NOTE: PLEASE CORRLELATE ALL A/C
 SYSTEMS, OCP AND LOADS, AS THESE SHOWN
 ON ELECTRICAL PANEL SCHEDULE DO NOT
 MATCH WITH THOSE AS SHOWN ON MECH
 SHEETS.
  
 24) NOTE: PLEASE VERIFY THE SIZE OF THE
 NEW METER CAN BEING SHOWN AS 225A?? THIS
 IS NOT KNOWN AS A COMMON SIZE. PLEASE
 ADJUST.
 215.5
  
 ** PLEASE KNOW,MANY OF THE ABOVE ITEMS
 ARE REDLINED ON ONE OF THE SETS OF
 PLANS, HOWEVER IS IN NO WAY ALL
 LOCATIONS AS NOTED ABOVE.
  
  
 ** PLEASE SUBMIT THE ABOVE FOR REVIEW
 AND IF THERE ARE ANY QUESTIONS OR
 COMMENTS, PLEASE DO NOT HESITATE IN
 CONTACTING THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  
  
  
  

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2006-10-25 Cont ID  
Sent By mmiller Date 2006-10-25 Time 18:43 Rev Time 0.00
Received By mmiller Date 2006-10-25 Time 18:43 Sent To B
Notes
2006-10-25 18:43:50SENT TO ALANGE DESK

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-09-05 Cont ID  
Sent By adarroug Date 2006-09-05 Time 11:33 Rev Time 0.00
Received By adarroug Date 2006-09-05 Time 11:33 Sent To E
Notes
2006-09-05 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-08-02 Cont ID  
Sent By adarroug Date 2006-08-02 Time 11:50 Rev Time 0.00
Received By adarroug Date 2006-08-02 Time 11:50 Sent To E
Notes
2006-08-02 00:00:00TO "DPALMER" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-06-22 Cont ID  
Sent By adarroug Date 2006-06-22 Time 11:44 Rev Time 0.00
Received By adarroug Date 2006-06-22 Time 11:44 Sent To E
Notes
2006-06-22 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-06-20 Cont ID  
Sent By adarroug Date 2006-06-20 Time 10:05 Rev Time 0.00
Received By adarroug Date 2006-06-20 Time 10:05 Sent To Z
Notes
2006-06-20 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-05-05 Cont ID  
Sent By adarroug Date 2006-05-05 Time 10:29 Rev Time 0.00
Received By adarroug Date 2006-05-05 Time 10:29 Sent To B
Notes
2006-05-05 00:00:00TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By mmclean Date 2006-05-04 Time 13:38 Rev Time 0.00
Received By adarroug Date 2006-04-19 Time 09:27 Sent To  
Notes
2006-04-19 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 2 Status P Date 2006-08-07 Cont ID  
Sent By tgordon Date 2006-08-07 Time 08:18 Rev Time 0.20
Received By tgordon Date 2006-08-07 Time 08:18 Sent To P
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-07-10 Cont ID  
Sent By tgordon Date 2006-07-10 Time 13:31 Rev Time 0.40
Received By tgordon Date 2006-07-10 Time 13:31 Sent To B
Notes
2006-07-10 00:00:00*** DENIED ***
 1) ENERGY CALCULATIONS NEED TO BE SIGNED
 BY OWNER/AGENT, PER 2004 FBC
 13-600.3.ABC.2
  
 2) EXHAUST FANS 1 AND 2 NEED TO BE 50
 CFM'S. PER 2004 FBC/R M1506.3 .
  
 3) AHU #1 CAN NOT GET IT'S RETURN AIR
 FROM THE KITCHEN, PER 2004 FBC/R M1602.4
 #4 .
  
 4) AHU #1 PROVIED RETURN AIR FOR DINNING
 ROOM, ENTRY HALL, AND BREAKFAST ROOM,
 SEE NOTE #5.
  
 5) BALANCED RETURN AIR.
 THIS MAY BE ACHIEVED BY.
 (A)TRANSFER DUCTS MAY ACHIEVE THIS BY
 INCREASING THE RETURN TRANSFER ONE AND
 ONE HALF TIMES THE CROSS SECTIONAL AREA
 (SQUARE INCHES) OF THE SUPPLY DUCT
 ENTERING THE ROOM OR SPACE IT'S SERVING
 AND THE DOOR HAVING AT LEAST AN
 UNRESTRICTED 1 INCHUNDERCUT TO ACHIEVE
 PROPER RETURN AIR BALANCE.
 (B)TRANSFER GRILLES SHALL USE 50
 SQUARE INCHES (OF GRILLE AREA) TO 100
 CFM (OF SUPPLY AIR) FOR SIZING
 THROUGH-THE-WALL TRANSFER GRILLES AND
 USING AN UNRESTRICTED 1-INCH
 UNDERCUTTING OF DOORS TO ACHIEVE PROPER
 RETURN AIR BALANCE
 (C)HABITABLE ROOMS ONLY SHALL BE
 REQUIRED TO MEET THESE REQUIREMENTS FOR
 PROPER BALANCED RETURN AIR EXCLUDING
 BATHROOMS, CLOSETS, STORAGE ROOMS AND
 LAUNDRY ROOMS, EXCEPT THAT ALL SUPPLY
 AIR INTO THE MASTER SUITE SHALL BE
 INCLUDED. PER 2004 FBC/R M1602.4 .
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-08-19 Cont ID  
Sent By pschmitz Date 2006-08-19 Time 13:04 Rev Time 0.00
Received By pschmitz Date 2006-08-19 Time 12:59 Sent To  
Notes
2006-08-19 00:00:00RE-SUB
 CONFIRM CLOTHES WASHER CONNECTION.

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-07-08 Cont ID  
Sent By jleech Date 2006-07-08 Time 08:37 Rev Time 0.00
Received By jleech Date 2006-07-08 Time 08:37 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 2 Status P Date 2006-06-21 Cont ID  
Sent By mmclean Date 2006-06-21 Time 16:22 Rev Time 0.00
Received By mmclean Date 2006-06-21 Time 16:22 Sent To I
Notes
2006-06-21 00:00:002 STORY ADDITION ONLY.
 SEC 94-303 MECHANICAL/POOL
 EQUIPMENT/GENERATOR MAY NOT PROJECT MORE
 THAN FOUR FEET INTO A SETBACK.
  

Review Stop Z ZONING
Rev No 1 Status F Date 2006-05-04 Cont ID  
Sent By mmclean Date 2006-05-04 Time 13:32 Rev Time 0.00
Received By mmclean Date 2006-05-04 Time 13:32 Sent To I
Notes
2006-05-04 00:00:00DENIED,
 1. MUST PROVIDE TWO COPY OF CURRENT
 SURVEY SHOWING THE EXISTING STRUCTURE
 WITH SETBACKS.
 2. MUST PROVIDE TWO COPY OF CURRENT
 SURVEY SHOWING THE PROPOSED WORK WITH
 SETBACK FROM PROPERTY LINE.
 3. MUST PROVIDE TWO SETS OF THE
 ELEVATION PLANS OF THE STRUCTURE
 (EXISTING & PROPOSED).
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720