Plan Review Stops For Permit 06040404 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2006-05-09 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-05-09 |
Time |
10:51 |
Rev Time |
0.33 |
Received By |
alange |
Date |
2006-05-09 |
Time |
10:51 |
Sent To |
|
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-06-21 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-06-21 |
Time |
11:22 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-06-21 |
Time |
11:01 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
P |
Date |
2006-05-05 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-05-05 |
Time |
07:09 |
Rev Time |
0.50 |
Received By |
btrobaug |
Date |
2006-05-05 |
Time |
06:59 |
Sent To |
M |
|
Notes |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2006-05-05 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-05-05 |
Time |
13:00 |
Rev Time |
0.15 |
Received By |
mperson |
Date |
2006-05-05 |
Time |
13:00 |
Sent To |
B |
|
Notes |
2006-05-05 00:00:00 | NOTE: GAS PERMIT REQUIRED. GAS CONTRAC- | | TOR TO SUBMIT PLANS WITH PERMIT APPLICA- | | TION. ALL GAS INSPECTIONS TO BE COMPLETE | | BEFORE FINAL GEN/RES INSPECTION. |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
5 |
Status |
N |
Date |
2006-06-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-15 |
Time |
16:52 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-15 |
Time |
16:52 |
Sent To |
E |
|
Notes |
2006-06-15 00:00:00 | TO "BTROBAUG" DESK/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-06-15 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-15 |
Time |
16:17 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-15 |
Time |
16:17 |
Sent To |
Z |
|
Notes |
2006-06-15 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-05-26 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-26 |
Time |
14:15 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-26 |
Time |
14:15 |
Sent To |
Z |
|
Notes |
2006-05-26 00:00:00 | TO "Z" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-05-04 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-04 |
Time |
10:32 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-04 |
Time |
10:32 |
Sent To |
E |
|
Notes |
2006-05-04 00:00:00 | TO "GEN-RES" "E" |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
2006-05-09 |
|
|
Cont ID |
|
Sent By |
alange |
Date |
2006-05-09 |
Time |
10:51 |
Rev Time |
0.00 |
Received By |
alange |
Date |
2006-04-14 |
Time |
14:36 |
Sent To |
|
|
Notes |
2006-04-14 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
2 |
Status |
P |
Date |
2006-06-21 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-06-21 |
Time |
11:58 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2006-06-21 |
Time |
11:58 |
Sent To |
|
|
Notes |
2006-06-21 00:00:00 | *** PROVISO *** | | 1) PER 2004 FBC, FUEL GAS - POWERED | | EQUIPMENT - PERMANENTLY INSTALLED | | EQUIPMENT POWERED BY INTERNAL COMBUSTION | | ENGINES SHALL BE INSTALLED IN ACCORDANCE | | WITH MANUFACTURE'S INSTALLATION | | INSTRUCTIONS AND NFPA 37. | | | | NFPA 37 INSTALLATION & USE OF STATIONARY | | COMBUSTION ENGINES & GAS TURBINES: | | 4.1.4ENGINES (GENERATORS) LOCATED | | OUTDOORS SHALL BE MINIMUM OF 5 FT FROM | | OPENINGS IN WALLS & AT LEAST 5 FT FROM | | STRUCTURES HAVING COMBUSTIBLE WALLS.A | | MINIMUM CLEARANCE IS NOT REQUIRED WHEN | | (1) THE ADJACENT WALL HAS A MINIMUM FIRE | | RESISTANCE RATING OF 1 HOUR OR (2) THE | | WEATHERPROOF ENCLOSURE IS CONSTRUCTED OF | | NON-COMBUSTIBLE MATERIALS, AND IT HAS | | BEEN DEMONSTRATED THAT A FIRE WITHIN THE | | ENCLOSURE WILL NOT IGNITE COMBUSTIBLE | | MATERIALS OUTSIDE THE ENCLOSURE. | | A.8.2.3.1EXHAUST SYSTEMS SHOULD NOT | | TERMINATE UNDER STRUCTURES OR WHERE THE | | EXHAUST MIGHT BE DRAWN INTO THE | | VENTILATION INTAKES. | | | | 2004 FMC 804.3.5 #3, WHERE THE | | TERMINATION IS LOCATED BELOW AN ADJACENT | | ROOF STRUCTURE, THE TERMINATION POINT | | SHALL BE LOCATED AT LEAST 3 FT FROM THE | | ROOF STRUCTURE. | | | | PLEASE NOTE, WHILE ZONING ALLOWS | | MECHANICAL EQUIPMENT TO ENCROACH 4 FT | | INTO THE SETBACK, GENERATORS SHALL | | MAINTAIN THE REQUIRED ABOVE MENTIONED | | CLEARANCES TO THE ADJACENT PROPERTY | | STRUCTURES, I.E. FENCE, BUILDING, | | WINDOWS, DOORS, OR OPENINGS. | | | | PROVIDE MANUFACTURE'S INSTALLATION | | INSTRUCTIONS AT THE JOBSITE FOR THE | | FIELD INSPECTOR. | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
M |
MECHANICAL (A/C) |
Rev No |
1 |
Status |
F |
Date |
2006-05-05 |
|
|
Cont ID |
|
Sent By |
tgordon |
Date |
2006-05-05 |
Time |
08:56 |
Rev Time |
0.15 |
Received By |
tgordon |
Date |
2006-05-05 |
Time |
08:56 |
Sent To |
P |
|
Notes |
2006-05-05 00:00:00 | *** DENIED *** | | 1) PLEASE SEE ZONING NOTES. | | | | 2) PLEASE BE ADVISED,GENERATOR EXHUST | | MUST BE TEN FEET AWAY FROM ANY BUILDING | | OPENINGS (WINDOWS, DOORS, ROOF & EAVE | | VENTS), AND TEN FEET AWAY FROM ADJECENT | | BUILDING OPENS. PER 2004 FBC/M 401.5.1 . | | | | MECHANICAL PLAN REVIEW BY; | | TOM GORDON (561) 805-6729. |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
N |
Date |
2006-05-05 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-05-05 |
Time |
12:59 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2006-05-05 |
Time |
12:59 |
Sent To |
G |
|
Notes |
|
|
Review Stop |
Z |
ZONING |
Rev No |
3 |
Status |
P |
Date |
2006-06-15 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-06-15 |
Time |
16:40 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-06-15 |
Time |
16:40 |
Sent To |
M |
|
Notes |
2006-06-15 00:00:00 | NOTE: THE PROPOSED GENERATOR WILL BE 4FT | | FROM SIDE PROPERTY LINE & 10FT FROM | | STRUCTURE. |
|
|
Review Stop |
Z |
ZONING |
Rev No |
2 |
Status |
F |
Date |
2006-06-02 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-06-02 |
Time |
15:10 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-06-02 |
Time |
15:10 |
Sent To |
|
|
Notes |
2006-06-15 00:00:00 | DENIED, | | 1. NEED TO PROVIDE TWO COPY OF HOA | | APPROVAL & PROVIDE A CBS WALL BUFFER | | AROUND THE GENERATOR. | | | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
F |
Date |
2006-05-03 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-05-03 |
Time |
11:54 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-05-03 |
Time |
11:54 |
Sent To |
I |
|
Notes |
2006-05-03 00:00:00 | DENIED, | | 1. THE GENERATOR MUST SIT BEYOND THE | | 25FT FRONT SETBACK. | | | | MICHELLE MCLEAN | | ZONING TECHNICIAN | | 805-6720 |
|
|