Plan Review Details - Permit 06040040
Plan Review Stops For Permit 06040040
Review Stop B BUILDING (STRUCTURAL)
Rev No 6 Status P Date 2007-03-30 Cont ID  
Sent By lmartine Date 2007-03-30 Time 19:00 Rev Time 0.00
Received By lmartine Date 2007-03-30 Time 19:00 Sent To  
Notes
2007-03-30 19:01:08MARCH 12TH REVISION OK

Review Stop B BUILDING (STRUCTURAL)
Rev No 5 Status P Date 2006-12-10 Cont ID  
Sent By rnuquist Date 2006-12-10 Time 13:11 Rev Time 0.00
Received By rnuquist Date 2006-12-10 Time 13:11 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status F Date 2006-10-17 Cont ID  
Sent By alange Date 2006-10-17 Time 08:06 Rev Time 2.00
Received By alange Date 2006-10-17 Time 08:06 Sent To M
Notes
2006-10-17 08:12:36DENIED
  
  
 1.PERMIT VALUATION IS TO LOW AND
 SHOULD INCLUDE ALL MATERIALS AND LABOR.
 ADDITIONAL PERMIT FEES ARE DUE.FEES
 PAID TO DATE REFLECT ONLY A $12,000
 VALUATION.ADJUST VALUE AND PAY FEES
 PRIOR TO RESUBMITTING PLANS.
  
 C.COMPLETE A SHUTTER SCHEDULE, SEE
 SAMPLE ATTACHED.
  
 D.SUBMIT PRODUCT APPROVALS FOR AN
 INSWING ENTRY DOOR.
  
 E.SUBMIT TWO SETS PRODUCT APPROVALS FOR ALL
 STRAPS AND TIE-DOWNS USED.ONLY ONE SET OF FL 503
 SUBMITTED.
  
 F.WINDOW AND DOOR PRESSURES NOT SHOW
 ON ALL ELAVATIONS.
  
 G.SUBMIT PRODUCT APPROVALS FOR
 OVERHEAD DOORS.
  
  
 K.SCOPE OF WORK IS STILL NOT CLEAR AND
 DOES NOT MATCH PERMIT APPLICATION.
 CLEARLY SHOW ON PLANS AREAS THAT WILL
 NOT HAVE ANY WORK DONE AND SHOW AS
 EXISTING.APPLICATION SHOWS ROT REPAIR
 YET PLANS SHOW FIRE DAMAGE?
  
 L.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
 NOTE:NOT ALL PRODUCT APPROVALS HAVE BEEN STAAMPED AND
 NONE HAVE BEEN APPROVED BY THE DESIGNER OF RECORD IN
 WRITING.
  
  
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2006-08-17 Cont ID  
Sent By alange Date 2006-08-17 Time 11:26 Rev Time 2.00
Received By alange Date 2006-08-17 Time 11:26 Sent To  
Notes
2006-08-17 00:00:00DENIED
  
  
 1.PERMIT VALUATION IS TO LOW AND
 SHOULD INCLUDE ALL MATERIALS AND LABOR.
 ADDITIONAL PERMIT FEES ARE DUE.FEES
 PAID TO DATE REFLECT ONLY A $12,000
 VALUATION.ADJUST VALUE AND PAY FEES
 PRIOR TO RESUBMITTING PLANS.
  
 2."R" VALUES ON ENERGY CALS DO NOT
 MATCH THOSE ON PLANS.
  
 A.STATE PRODUCT APPROVALS REQUIRED FOR
 STANLY DOOR.
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A COVER SHEET THAT LISTS
 THE PRODUCT IDENTITY NUMBER FROM THE
 STATE. IF THE PRODUCT DOES NOT HAVE
 STATEWIDE APPROVAL, SUBMIT AN APPLICA-
 TION FOR LOCAL PRODUCT APPROVAL OR SITE
 SPECIFIC FORM PER RULE 9B-72. SEE
 ATTACHMENT. WWW.FLORIDABUILDING.ORG
  
 B.SUBMIT PRODUCT APPROVALS FOR
 MULLIONS.
  
 C.COMPLETE A SHUTTER SCHEDULE, SEE
 SAMPLE ATTACHED.
  
 D.SUBMIT PRODUCT APPROVALS FOR AN
 INSWING ENTRY DOOR.
  
 E.SUBMIT PRODUCT APPROVALS FOR ALL
 STRAPS AND TIE-DOWNS USED.INFORMATIONS
 SUBMITTED IS ONLY SIMPSON SPEC. SHEETS.
  
 F.WINDOW AND DOOR PRESSURES NOT SHOW
 ON ALL ELAVATIONS.
  
 G.SUBMIT PRODUCT APPROVALS FOR
 OVERHEAD DOORS.
  
 H.PLANS SHALL BE DESIGNED TO THE 2004
 FORIDA RESIDENTIAL CODE.SEE PLUMBING
 PAGE NOTE.
  
 I.SMOKE ALARMS SHALL BE INSTALLED IN
 THE FOLLOWING LOCATIONS: R 313.1
 1.IN EACH SLEEPING ROOM.
 2.OUTSIDE EACH SEPARATE SLEEPING
 AREA IN THE IMMEDIATE VICINITY OF THE
 BEDROOMS.
 3.ON EACH ADDITIONAL STORY OF THE
 DWELLING, INCLUDING BASEMENTS BUT NOT
 INCLUDING CRAWL SPACES AND UNINHABITABLE
 ATTICS. IN DWELLINGS OR DWELLING UNITS
 WITH SPLIT LEVELS AND WITHOUT AN
 INTERVENING DOOR BETWEEN THE ADJACENT
 LEVELS, A SMOKE ALARM INSTALLED ON THE
 UPPER LEVEL SHALL SUFFICE FOR THE
 ADJACENT LOWER LEVEL PROVIDED THAT THE
 LOWER LEVEL IS LESS THAN ONE FULL STORY
 BELOW THE UPPER LEVEL.
 WHEN MORE THAN ONE SMOKE ALARM IS
 REQUIRED TO BE INSTALLED WITHIN AN
 INDIVIDUAL DWELLING UNIT THE ALARM
 DEVICES SHALL BE INTERCONNECTED IN SUCH
 A MANNER THAT THE ACTUATION OF ONE ALARM
 WILL ACTIVATE ALL OF THE ALARMS IN THE
 INDIVIDUAL UNIT. THE ALARM SHALL BE
 CLEARLY AUDIBLE IN ALL BEDROOMS OVER
 BACKGROUND NOISE LEVELS WITH ALL
 INTERVENING DOORS CLOSED.
 ALL SMOKE ALARMS SHALL BE LISTED AND
 INSTALLED IN ACCORDANCE WITH THE
 PROVISIONS OF THIS CODE AND THE
 HOUSEHOLD FIRE WARNING EQUIPMENT
 PROVISIONS OF NFPA 72.
  
 J.SAFETY GLASS REQUIRED IN WINDOWS IN
 BATHROOM NEAR TUB LOCATIONSR-308.1
  
 K.SCOPE OF WORK IS STILL NOT CLEAR AND
 DOES NOT MATCH PERMIT APPLICATION.
 CLEARLY SHOW ON PLANS AREAS THAT WILL
 NOT HAVE ANY WORK DONE AND SHOW AS
 EXISTING.APPLICATION SHOWS ROT REPAIR
 YET PLANS SHOW FIRE DAMAGE?
  
 L.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
  
  
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status F Date 2006-07-05 Cont ID  
Sent By alange Date 2006-07-05 Time 10:56 Rev Time 1.00
Received By alange Date 2006-07-05 Time 10:50 Sent To  
Notes
2006-07-05 00:00:00DENIED
  
  
 1.PERMIT VALUATION IS TO LOW AND
 SHOULD INCLUDE ALL MATERIALS AND LABOR.
 ADDITIONAL PERMIT FEES ARE DUE.
  
  
 2.PREPARER SHALL SIGN ENERGY CALCS
 SUBMITTED.
  
 3.REMOVE PRODUCT APPROVALS AND ANY
 PAGES SHOWING NEW WINDOWS AND DOORS
 SINCE THEY WILL BE ON A SEPERATE PERMIT.
  
 6.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 8.PRODUCT APPROVALS HAVE BEEN
 SUBMITTED FOR DOORS AND WINDOWS.PLANS
 SPEC THEM TO DONE BY OTHERS.IF THEY
 WILL BE ON A SEPERATE PERMIT PLEASE
 REMOVE FROM THIS PLAN.
 NEW COMMENT: PLANS DO NOT REFLECT WORK
 DESCRIBED ON APPLICATION.IF YOU WILL
 BE DOING ONLY ROT REPAIR UNDER THIS
 PERMIT SHOW REPAIRS TO BE MADE.
 STRUCTURAL DRAWINGS MAY BE NEEDED.IF
 NEW FRAMING IS GOING TO BE DONE. SHOW
 NEW AND EXISTING ON PLANS.WILL THERE
 BE NEW INSULATION AND DRYWALL?
 INSUFFICIENT INFORMATION SUBMITTED FOR A
 COMPLETE REVIEW.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-05-01 Cont ID  
Sent By alange Date 2006-05-01 Time 10:59 Rev Time 0.00
Received By alange Date 2006-05-01 Time 10:59 Sent To  
Notes
2006-05-01 00:00:00DENIED
  
  
 1.PERMIT VALUATION IS TO LOW AND
 SHOULD INCLUDE ALL MATERIALS AND LABOR.
 ADDITIONAL PERMIT FEES ARE DUE.
  
  
 2.SIGN TWO COPIES OF ENERGY CALCS
 SUBMITTED.
  
 3.PRODUCT APPROVALS REQUIRED FOR
 IMPACT PROTECTION.
  
 4.ALL PRODUCT APPROVALS SUBMITTED WITH
 QUALITY ASSURANCE SHALL HAVE THE
 FOLLOWING STATE APPROVAL ATTACHED.
  
 PRODUCT APPROVALS SUBMITTED WITH
 PERMIT APPLICATION AFTER OCTOBER 1, 2003
 ARE REQUIRED TO COMPLY WITH THE FLORIDA
 PRODUCT APPROVAL SYSTEM. FOR INFORMATION
 PLEASE SEE THE STATE WEBSITE AT
 WWW.FLORIDABUILDING.ORG. PRODUCTS WITH
 STATEWIDE APPROVAL ARE REQUIRED TO BE
 SUBMITTED WITH A STATE PRODUCT APPROVAL
 SHEETS THAT LISTS THE PRODUCT IDENTITY
 NUMBER FROM THE STATE. IF THE PRODUCT
 DOES NOT HAVE STATEWIDE APPROVAL, SUBMIT
 AN APPLICATION FOR LOCAL PRODUCT
 APPROVAL OR SITE SPECIFIC FORM PER RULE
 9B-72. SEE ATTACHMENT.
 WWW.FLORIDABUILDING.ORG
  
 5.THOSE PRODUCT APPROVALS WHICH ARE
 REGULATED BY DCA RULE 9B-72 SHALL BE
 REVIEWED AND APPROVED IN WRITING BY THE
 DESIGNER OF RECORD PRIOR TO SUBMITTAL
 FOR JURISDICTIONAL APPROVAL.WPB
 AMENDMENT TO FBC 106.3.3.
  
 6.A DESIGN PROFESSIONAL OR AN OWNER
 MUST ELECT ONE OR A COMBINATION OF
 LEVELS OF ALTERATION PURSUANT TO
 SECTIONS 303, 304 AND 305 OF THIS CODE.
 SHOW HOW PLANS WILL COMPLY WITH THE
 SECTION(S) SELECTED.2004 FBC EXISTING
 BUILDING 301.5
  
 7. ALL PLANS SUBMITTED AFTER OCTOBER, 1,
 2005 SHALL BE DESIGNED TO THE 2004
 FLORIDA BUILDING CODE.
  
 8.PRODUCT APPROVALS HAVE BEEN
 SUBMITTED FOR DOORS AND WINDOWS.PLANS
 SPEC THEM TO DONE BY OTHERS.IF THEY
 WILL BE ON A SEPERATE PERMIT PLEASE
 REMOVE FROM THIS PLAN.
  
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. SUBMIT ONE COPY OF
 OLD PAGES FOR REFERENCE. A TRANSMITTAL
 LETTER LISTING THE ORIGINAL REVIEW
 COMMENT NUMBER, WITH A DESCRIPTION OF
 THE REVISION MADE, IDENTIFYING THE SHEET
 OR SPECIFICATION PAGE WHERE THE CHANGES
 CAN BE FOUND WILL HELP TO EXPEDITE YOUR
 PERMIT. THANK YOU FOR YOUR ANTICIPATED
 COOPERATION.
  
 ART LANGE
 CONSTRUCTION SERVICES DEPARTMENT
 BUILDING PLANS EXAMINER
 561-805-6672

Review Stop E ELECTRICAL
Rev No 8 Status P Date 2007-06-20 Cont ID  
Sent By jleahy Date 2007-06-20 Time 17:18 Rev Time 0.45
Received By jleahy Date 2007-06-20 Time 17:18 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 7 Status P Date 2007-04-24 Cont ID  
Sent By jleahy Date 2007-04-24 Time 11:02 Rev Time 1.00
Received By jleahy Date 2007-04-24 Time 11:02 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 6 Status P Date 2007-02-27 Cont ID  
Sent By btrobaug Date 2007-02-27 Time 13:23 Rev Time 0.50
Received By btrobaug Date 2007-02-27 Time 13:15 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 5 Status P Date 2006-11-16 Cont ID  
Sent By jleahy Date 2006-11-16 Time 06:37 Rev Time 1.00
Received By jleahy Date 2006-11-16 Time 06:37 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 4 Status F Date 2006-09-27 Cont ID  
Sent By jleahy Date 2006-09-27 Time 06:47 Rev Time 0.45
Received By jleahy Date 2006-09-27 Time 06:47 Sent To P
Notes
2006-09-27 00:00:00SEE NOTES FROM 8/16 THEY HAVE NOT
 CHANGED EXCEPT FOR THE NOTE ABOUT THE
 PERSON WHO DREW THESE.
  
 JAKE LEAHY644-7291

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-08-16 Cont ID  
Sent By jleahy Date 2006-08-16 Time 07:54 Rev Time 1.00
Received By jleahy Date 2006-08-16 Time 07:54 Sent To M
Notes
2006-08-16 00:00:00PROVISO: THESE PROBLEMS NEED TO BE FIXED
 BEFORE FINAL OR NO POWER WILLL BE
 RELEASED TO THE BUILDINGS.JLEAHY
  
  
 RISER DIAGRAM ONLY SHOWS 2/0 WIRE IF THE
 LOAD CALCULATION FOR THE UNITS IS A 138
 EACH THEN THE 2/0S ARE TOO SMALL. PLEASE
 RESUBMIT NEW CLACULATIONS OR A NEW RISER
 DIAGRAM.
  
 ON PAGE 4-7 RISER SHOWS TWO 200A AMIN
 ACCORDING TO THE NOTES IN THE PANEL
 SCHEDULE, BUT ON THE BUILDING YOU SHOW 1
 AT 200 AND 1 AT 150????? PLEASE FIX
 BEFORE FINAL ELECTRICAL INSPECTION.
  
 PAGE 5-7 RISER SHOWS 200AMP MAIN, PANEL
 SCHEDULR SHOWS 150AMP MAIN. PLEASE FIX
 BEFORE FINAL INSPECTION.
  
 NEED THE PERSON WHO HAS DRAWN THESE TO
 SIGN AND DATE THESE PLANS FOR THE ELEC.
  
 THESE ARE THE SAME COMMENTS THAT WHERE
 GIVEN TO YOU ON 8/19 PLEASE FIX OR YOU
 WILL NOT GET POWER TO THE UNITS/OR HAVE
 POWER SHUT OFF TO THE UNITS!!!!!!!!!!

Review Stop E ELECTRICAL
Rev No 2 Status F Date 2006-06-14 Cont ID  
Sent By jleahy Date 2006-06-14 Time 09:42 Rev Time 0.30
Received By jleahy Date 2006-06-14 Time 09:42 Sent To P
Notes
2006-06-14 00:00:00PAGE 5-7
  
 RISER SHOWS TWO MAINS OFF ONE RISER
 WIRE IS GOOD FOR 200A, HOW IS SECOND
 METER FED?
  
 NO PANEL SCHEDULE SHOWN FOR SECOND
 PANEL.NO LOAD CALCULATION SHOWN FOR
 THE SPACE INVOLVED!!!!!!!!!
  
 NO LOAD CALCULATION FOR BOTH UNITS SHOWN
 PER NEC.
  
 YOU HAVE TWO PAGES 5-7 PLEASE CHANGE ONE
 OR YOU WILL FAIL AGAIN.
  
 IF STORAGE UNIT IS FOR BOTH TENANTS YOU
 NEED A SEPARATE METER AND PANEL FOR THAT
 ROOM!!!!
  
 CHECK YOUR LOAD CALCULATIONS SHOW THAT
 BOTH UNITS ARE 1200 SQFT???????????????
  
 NEED THE PERSON WHO DESIGNED THIS PLAN
 TO SIGN IT AND DATE IT.

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-04-11 Cont ID  
Sent By jleahy Date 2006-04-11 Time 08:49 Rev Time 0.45
Received By jleahy Date 2006-04-10 Time 08:11 Sent To  
Notes
2006-04-10 00:00:00RISER SHOWS INDIVIDUAL METERS LOCATIONS
 FOR UP AND DOWN MAINS TO BE GROUPED
 230.72
  
 PLANS ALSO SHOW DUPLEX METER ON BUILDING
 BUT NOT ON THE ELECTRICAL PLAN.
  
  
 CALL PHILLIP PETTY805-6742

Review Stop I INCOMING/PROCESSING
Rev No 10 Status N Date 2007-06-20 Cont ID  
Sent By adarroug Date 2007-06-20 Time 14:37 Rev Time 0.00
Received By adarroug Date 2007-06-20 Time 14:37 Sent To E
Notes
2007-06-20 14:37:38TO "JLEAHY" DESK/RESTAMP

Review Stop I INCOMING/PROCESSING
Rev No 9 Status N Date 2007-04-23 Cont ID  
Sent By adarroug Date 2007-04-23 Time 08:27 Rev Time 0.00
Received By adarroug Date 2007-04-23 Time 08:27 Sent To E
Notes
2007-04-23 08:28:03TO "JLEAHY" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 8 Status N Date 2007-03-19 Cont ID  
Sent By adarroug Date 2007-03-19 Time 10:48 Rev Time 0.00
Received By adarroug Date 2007-03-19 Time 10:48 Sent To M
Notes
2007-03-19 10:49:30TO "M" BOX/REV

Review Stop I INCOMING/PROCESSING
Rev No 7 Status N Date 2007-03-12 Cont ID  
Sent By adarroug Date 2007-03-12 Time 13:12 Rev Time 0.00
Received By adarroug Date 2007-03-12 Time 13:12 Sent To B
Notes
2007-03-12 13:12:41TO"LMARTINEZ" DESK/REV

Review Stop I INCOMING/PROCESSING
Rev No 6 Status N Date 2006-12-04 Cont ID  
Sent By adarroug Date 2006-12-04 Time 10:58 Rev Time 0.00
Received By adarroug Date 2006-12-04 Time 10:58 Sent To B
Notes
2006-12-04 10:59:01TO "LMARTINEZ" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 5 Status N Date 2006-11-12 Cont ID  
Sent By adarroug Date 2006-11-12 Time 15:00 Rev Time 0.00
Received By adarroug Date 2006-11-12 Time 15:00 Sent To E
Notes
2006-11-12 15:01:21TO "JLEAHY" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-09-22 Cont ID  
Sent By adarroug Date 2006-09-22 Time 10:22 Rev Time 0.00
Received By adarroug Date 2006-09-22 Time 10:22 Sent To E
Notes
2006-09-22 00:00:00TO "JLEAHY" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-08-14 Cont ID  
Sent By adarroug Date 2006-08-14 Time 09:11 Rev Time 0.00
Received By adarroug Date 2006-08-14 Time 09:11 Sent To E
Notes
2006-08-14 00:00:00TO "JLEAHY" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-06-07 Cont ID  
Sent By adarroug Date 2006-06-07 Time 16:21 Rev Time 0.00
Received By adarroug Date 2006-06-07 Time 16:21 Sent To E
Notes
2006-06-07 00:00:00TO "JLEAHY" DESK/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-05-01 Cont ID  
Sent By alange Date 2006-05-01 Time 11:04 Rev Time 0.00
Received By alange Date 2006-04-04 Time 15:55 Sent To  
Notes
2006-04-04 00:00:00TO "E" BOX

Review Stop M MECHANICAL (A/C)
Rev No 6 Status P Date 2007-03-29 Cont ID  
Sent By tgordon Date 2007-03-29 Time 07:53 Rev Time 0.25
Received By tgordon Date 2007-03-29 Time 07:53 Sent To  
Notes
2007-03-29 07:54:04REVISION TO MECH. PLANS.

Review Stop M MECHANICAL (A/C)
Rev No 5 Status F Date 2007-03-19 Cont ID  
Sent By tgordon Date 2007-03-19 Time 12:04 Rev Time 0.30
Received By tgordon Date 2007-03-19 Time 12:04 Sent To  
Notes
2007-03-19 12:09:12MECHANICAL REVISION
 *** DENIED ***
 1) THE ORIGINAL MECHANICAL PLANS ON FILE ARE SEALED BY
 ANENGINEER (GORDON F. BUCK) SO ONLY HE CAN MAKE
 REVISIONS TO THE MECHANICAL PLANS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 4 Status P Date 2006-10-17 Cont ID  
Sent By tgordon Date 2006-10-17 Time 09:23 Rev Time 0.30
Received By tgordon Date 2006-10-17 Time 09:23 Sent To  
Notes
***NONE***

Review Stop M MECHANICAL (A/C)
Rev No 3 Status F Date 2006-08-16 Cont ID  
Sent By tgordon Date 2006-08-16 Time 11:04 Rev Time 0.25
Received By tgordon Date 2006-08-16 Time 11:04 Sent To B
Notes
2006-08-16 00:00:00*** DENIED ***
 1) AS REQUESTED IN LAST TWO REVIEW,
 ENERGY CALCULATIONS NEED TO BE
 SIGNED BY THE PREPARER ALSO. A STAMP IS
 NOT A SIGNATURE, PER 2004 FBC
 13-600.3.ABC.1.1 .
  
 2) PLEASE SEE ATTACHED NOTICE REGARDING
 FS 553.80(2)(B) FOUR TIMES THE FEE.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.
  

Review Stop M MECHANICAL (A/C)
Rev No 2 Status F Date 2006-06-19 Cont ID  
Sent By tgordon Date 2006-06-19 Time 12:04 Rev Time 0.30
Received By tgordon Date 2006-06-19 Time 12:04 Sent To B
Notes
2006-06-19 00:00:00*** DENIED ***
 1) AS REQUESTED IN LAST REVIEW 4-10-06
 NOTE #1, ENERGY CALCULATIONS NEED TO BE
 SIGNED BY THE PREPARER ALSO.
  
 2) AS REQUSTED IN LAST REVIEW 4-10-06
 NOTE #2 ENERGY CALCULATIONS ARE CALLING
 FOR UNIT #2 HEATER TO BE 5 KW,
 MECHANICAL PLANS ARE CALLING FOR UNIT #2
 HEATER TO BE 8.5 KW, THE TWO MUST
 COINSIDE PLEASE CORRECT THE ENERGY
 CAL'S. OR THE MECHANICAL PLANS.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop M MECHANICAL (A/C)
Rev No 1 Status F Date 2006-04-10 Cont ID  
Sent By tgordon Date 2006-04-10 Time 10:36 Rev Time 0.45
Received By tgordon Date 2006-04-10 Time 10:36 Sent To P
Notes
2006-04-10 00:00:00*** DENIED ***
 1) ENERGY CAL'S. NEED TO BE SIGNED BY
 PREPARER AND OWNER/AGENT.
  
 2) ENERGY CAL'S. ARE CALLING FOR A/C #2
 TO HAVE 5 KW HEAT, ELECT. AND MECH.
 PLANS ARE CALLING FOR 8 KW HEAT, PLEASE
 CORRECT.
  
 3) SHOW ON MECH. PLANS HOW AHU #2 IS
 GETTING ITS RETURN AIR AND ACCESS FOR
 SERVICE.
  
 4) SHOW ON MECH. PLANS LOCATION OF
 CONDENSER UNIT #2.
  
 5) BOLTH A/C SYSTEMS ARE LISTED AS #1 ON
 MECH. PLANS, PLEASE CORRECT.
  
 6) WHITE OUT CAN NOT BE USED ON PLANS
 PLEASE SUBMIT CORRECTED PLANS WITH OUT
 (WHITE OUT) ON THEM.
  
 MECHANICAL PLAN REVIEW BY;
 TOM GORDON (561) 805-6729.

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-10-14 Cont ID  
Sent By jleech Date 2006-10-14 Time 07:25 Rev Time 0.00
Received By jleech Date 2006-10-14 Time 07:25 Sent To B
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-06-19 Cont ID  
Sent By jleech Date 2006-06-19 Time 10:12 Rev Time 0.00
Received By jleech Date 2006-06-19 Time 10:12 Sent To M
Notes
***NONE***

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-04-11 Cont ID  
Sent By jleech Date 2006-04-11 Time 08:27 Rev Time 0.00
Received By jleech Date 2006-04-11 Time 08:27 Sent To B
Notes
2006-04-11 00:00:00DENIED;
 1.SANITARY RISER DIAGRAM AND FLAT
 DRAWING DO NOT MATCH;
 A.FIRST FLOOR TUB AND SHOWER ARE
  
 NOT VENTED.
 B.FLAT DRAWING, SECOND FLOOR BATH-
 ROOM SHOWER IS NOT VENTED.
 C. KITCHEN SINK SHOULD BE DOWN
 STREAM OF BATHROOM GROUP SEC.
 909.1
 D. RISER DIAGRAM DOES NOT MATCH
 FLOOR PLAN.
 2. PLANS ARE BEING REVIEW UNDER THE
 FBC-2004 EDITION NOT 2001 PLEASE CHANGE
 NOTES.
 PLUMBING PLAN REVIEW BY;
 JOHN LEECH
 805-6695