Plan Review Stops For Permit 06040012 |
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
3 |
Status |
P |
Date |
2006-06-13 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-06-13 |
Time |
06:27 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-06-13 |
Time |
06:02 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
2 |
Status |
P |
Date |
2006-06-01 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-06-01 |
Time |
06:53 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-06-01 |
Time |
06:23 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
B |
BUILDING (STRUCTURAL) |
Rev No |
1 |
Status |
P |
Date |
2006-04-28 |
|
|
Cont ID |
|
Sent By |
mjacobs |
Date |
2006-04-28 |
Time |
06:25 |
Rev Time |
0.00 |
Received By |
mjacobs |
Date |
2006-04-27 |
Time |
13:08 |
Sent To |
PC |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
3 |
Status |
P |
Date |
2006-06-12 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-06-12 |
Time |
15:09 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-06-12 |
Time |
14:55 |
Sent To |
B |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
2 |
Status |
P |
Date |
2006-05-26 |
|
|
Cont ID |
|
Sent By |
btrobaug |
Date |
2006-05-26 |
Time |
07:15 |
Rev Time |
0.33 |
Received By |
btrobaug |
Date |
2006-05-26 |
Time |
06:53 |
Sent To |
P |
|
Notes |
|
|
Review Stop |
E |
ELECTRICAL |
Rev No |
1 |
Status |
F |
Date |
2006-04-11 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-04-11 |
Time |
14:08 |
Rev Time |
0.00 |
Received By |
dpalmer |
Date |
2006-04-11 |
Time |
13:10 |
Sent To |
P |
|
Notes |
2006-04-11 00:00:00 | ********** UNSAT ************ | | | | 1) NOTE: PLEASE CORRELATE ELECTRICAL | | PLANS WITH LOAD CALCUALTIONS SUBMITTED. | | PLEASE SEE PLANS INDICATE THREE LTS. | | 215.5 | | | | 2) NOTE: PLEASE COMPLETE MIN WIRING ON | | ELECTRICAL WIRING DIAGRAM FOR EQUIPMENT. | | PLEASE SEE PUMP, HEATER, ETC DO NOT | | INDICATE ANY SIZES ETC. | | 240.4,310.16,215.5 | | | | 3) NOTE: PLEASE SEE SPECS SUBMITTED FOR | | POOL HEATERARE FOR A GAS HEATER AND | | PLANS MENTIONS AN ELECTRICAL HEAT PUMP? | | PLEASE ADJUST PLANS,OR LOADS AND PANEL | | SCHEDULE ACCORDINGLY. | | PLEASE SUBMIT SPECS FOR THE HEAT PUMP | | BEING INSTALLED IN THIS HOUSE AND FOR | | THIS JOB. SPECS AND CALCS SHALL NOT BE | | GENERIC AS THE CODE REQUIRES EACH | | JOBSITE SCOPE TO BE SPECIFIC. | | ALL SPECS SHALL INDICATE A NRTL. | | 215.5 | | | | 4) NOTE: PLEASE SEE HEATER AS LISTED ON | | PANEL SCHEDULE SHOWS 2-POLE 60A ON#8. | | PLEASE SEE 240.4,310.16,240.6, AS THIS | | MUST BE # 6 AWG OR LARGER. | | | | 5) NOTE: PLEASE INDICATE ALL CONTINUOUS | | LOADS AT 125%. LOADS ONLY SHOWTHE | | LARGEST MOTOR LOAD AT 125%. | | PLEASE KNOW THE HEAT PUMP WILL RUN 3 OR | | MORE HRS AND WILL BE CONSIDERED | | CONTINUOUS. 215.3,230.42 | | | | 6) NOTE: PLEASE SEE PLANS MISSING THE | | REQUIRED EQUIPMENT GROUNDING CONDUCTOR | | FEEDING NEW SUB PANEL. | | | | 7) NOTE: PLEASE SUBMIT LOAD CALCULATIONS | | FOR THE EXISTING SERVICE AND THE | | ADDITION OF THE NEW LOADS. PLEASE SEE | | ONLY THE LOADS FOR THE NEW SUB PANEL | | WERE SUBMITTED AND NO INFORMATION FOR | | SIZE AND EXISTING PANEL/SERVICE LOAD WAS | | GIVEN. | | 220.31B,215.5 | | | | PLEASE SUBMIT THE ABOVE INFORMATION FOR | | REVIEW. IF THERE ARE ANY QUESTIONS, | | PLEASE DO NOT HESITATE IN CONTACTING | | THIS OFFICE. | | | | DEWEY PALMER | | ELECTRICAL PLAN REVIEW | | 561-805-6717 | | [email protected] | | |
|
|
Review Stop |
G |
GAS REVIEW |
Rev No |
1 |
Status |
N |
Date |
2006-04-12 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-04-12 |
Time |
16:10 |
Rev Time |
0.00 |
Received By |
mperson |
Date |
2006-04-12 |
Time |
16:10 |
Sent To |
B |
|
Notes |
2006-04-12 00:00:00 | NOTE: NO GAS |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
4 |
Status |
N |
Date |
2006-06-07 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-06-07 |
Time |
15:34 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-06-07 |
Time |
15:34 |
Sent To |
P |
|
Notes |
2006-06-07 00:00:00 | TO "P" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
3 |
Status |
N |
Date |
2006-05-24 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-05-24 |
Time |
13:47 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-05-24 |
Time |
13:47 |
Sent To |
E |
|
Notes |
2006-05-24 00:00:00 | TO "E" BOX/RESUB |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
2 |
Status |
N |
Date |
2006-04-10 |
|
|
Cont ID |
|
Sent By |
adarroug |
Date |
2006-04-10 |
Time |
16:37 |
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-10 |
Time |
16:37 |
Sent To |
E |
|
Notes |
2006-04-10 00:00:00 | TO "E" BOX |
|
|
Review Stop |
I |
INCOMING/PROCESSING |
Rev No |
1 |
Status |
N |
Date |
|
|
|
Cont ID |
|
Sent By |
|
Date |
2006-04-28 |
Time |
|
Rev Time |
0.00 |
Received By |
adarroug |
Date |
2006-04-03 |
Time |
13:34 |
Sent To |
|
|
Notes |
2006-04-03 00:00:00 | TO "Z" BOX |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
3 |
Status |
P |
Date |
2006-06-12 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-06-12 |
Time |
13:51 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-06-12 |
Time |
13:51 |
Sent To |
E |
|
Notes |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
2 |
Status |
F |
Date |
2006-05-30 |
|
|
Cont ID |
|
Sent By |
mperson |
Date |
2006-05-30 |
Time |
10:40 |
Rev Time |
0.33 |
Received By |
mperson |
Date |
2006-05-30 |
Time |
10:40 |
Sent To |
B |
|
Notes |
2006-05-30 00:00:00 | ******DENIED 2ND TIME****** | | REFERENCE: FBC-2004 SEC.424.2,OR | | FBCR-2004 SEC. R4101 SWIMMING POOLS | | | | THE FOLLOWING INFORMATION IS REQUIRED | | FOR PLUMBING PLAN REVIEW FOR A PERMIT: | | | | 1) PLEASE CORRELATE THE LEGEND WITH THE | | EQUIPMENT LAYOUT, SEE THE CORRECTED | | DRAWINGS IN RED INK FOR REFERENCE FOR | | RESUBMITTAL. | | 2) FBC-2004 SEC. 424.2.14.1, OR | | FBCR-2004 SEC. R4101.14.1 SWIMMING POOL | | WATER HEATERS SHALL BEAR THE LABEL OF A | | RECOGNIZED TESTING AGENCY. (MANUFACTURE | | SHEETS REQUIRED, PLEASE SUBMIT) | | 3) FBC-2004 SEC. 424.2.14.2, OR | | FBCR-2004 SEC. R4101.14.2 WATER | | RETENTION, PROVIDE A POSITIVE MEANS OF | | RETAINING WATER IN THE HEATER WHEN PUMP | | IS SHUT OFF.(MANUFACTURE SHEETS | | REQUIRED, PLEASE SUBMIT) | | 4) NOTE: THIS IS A CONTINUING PROBLEM | | WITH POOL HEATER MANUFACTURE SUBMITTAL | | SHEETS TO SEE IF THEY COMPLY WITH THE | | ABOVE, IN THE FUTURE PLEASE TRY TO | | COMPLY WITH THE ABOVE IN ORDER TO | | EXPIDITE PLAN REVIEW. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 | | | | | | |
|
|
Review Stop |
P |
PLUMBING |
Rev No |
1 |
Status |
F |
Date |
2006-04-12 |
|
|
Cont ID |
|
Sent By |
dpalmer |
Date |
2006-04-12 |
Time |
14:45 |
Rev Time |
0.45 |
Received By |
mperson |
Date |
2006-04-12 |
Time |
16:11 |
Sent To |
B |
|
Notes |
2006-04-12 00:00:00 | ******DENIED****** | | REFERENCE: FBC-2004 424.2 SWIMMING POOLS | | | | PLEASE ADJUST YOUR NOTES, DETAILS, OR | | SUMMITTALS TO REFLECT THE FOLLOWING | | INFORMATION REQUIRED FOR PLAN REVIEW. | | | | 1. PLEASE CORRELATE THE EQUIPMENT LAYOUT | | WITH THE LEGEND. | | 2. PRINT INDICATES A 5 TON ELECTRIC HEAT | | PUMP. THE MANUFACTURER'S SUBMITTAL IS A | | GAS HEATER. PLEASE CORRELATE THE | | MANUFACTURER SUBMITTAL WITH THE PRINT. | | | | END OF COMMENTS: | | | | REVIEW BY MIKE PERSON | | (561) 805-6730 | | FAX (561) 805-6731 | | E-MAIL [email protected] | | UNDER SUPERVISION OF K.STEVENS | | (561) 805-6721 |
|
|
Review Stop |
Z |
ZONING |
Rev No |
1 |
Status |
P |
Date |
2006-04-10 |
|
|
Cont ID |
|
Sent By |
mmclean |
Date |
2006-04-10 |
Time |
14:16 |
Rev Time |
0.00 |
Received By |
mmclean |
Date |
2006-04-10 |
Time |
14:16 |
Sent To |
I |
|
Notes |
2006-04-10 00:00:00 | SPA & ONLY. |
|
|