Plan Review Details - Permit 06040012
Plan Review Stops For Permit 06040012
Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status P Date 2006-06-13 Cont ID  
Sent By mjacobs Date 2006-06-13 Time 06:27 Rev Time 0.00
Received By mjacobs Date 2006-06-13 Time 06:02 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-06-01 Cont ID  
Sent By mjacobs Date 2006-06-01 Time 06:53 Rev Time 0.00
Received By mjacobs Date 2006-06-01 Time 06:23 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-04-28 Cont ID  
Sent By mjacobs Date 2006-04-28 Time 06:25 Rev Time 0.00
Received By mjacobs Date 2006-04-27 Time 13:08 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 3 Status P Date 2006-06-12 Cont ID  
Sent By btrobaug Date 2006-06-12 Time 15:09 Rev Time 0.33
Received By btrobaug Date 2006-06-12 Time 14:55 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-05-26 Cont ID  
Sent By btrobaug Date 2006-05-26 Time 07:15 Rev Time 0.33
Received By btrobaug Date 2006-05-26 Time 06:53 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-04-11 Cont ID  
Sent By dpalmer Date 2006-04-11 Time 14:08 Rev Time 0.00
Received By dpalmer Date 2006-04-11 Time 13:10 Sent To P
Notes
2006-04-11 00:00:00********** UNSAT ************
  
 1) NOTE: PLEASE CORRELATE ELECTRICAL
 PLANS WITH LOAD CALCUALTIONS SUBMITTED.
 PLEASE SEE PLANS INDICATE THREE LTS.
 215.5
  
 2) NOTE: PLEASE COMPLETE MIN WIRING ON
 ELECTRICAL WIRING DIAGRAM FOR EQUIPMENT.
 PLEASE SEE PUMP, HEATER, ETC DO NOT
 INDICATE ANY SIZES ETC.
 240.4,310.16,215.5
  
 3) NOTE: PLEASE SEE SPECS SUBMITTED FOR
 POOL HEATERARE FOR A GAS HEATER AND
 PLANS MENTIONS AN ELECTRICAL HEAT PUMP?
 PLEASE ADJUST PLANS,OR LOADS AND PANEL
 SCHEDULE ACCORDINGLY.
 PLEASE SUBMIT SPECS FOR THE HEAT PUMP
 BEING INSTALLED IN THIS HOUSE AND FOR
 THIS JOB. SPECS AND CALCS SHALL NOT BE
 GENERIC AS THE CODE REQUIRES EACH
 JOBSITE SCOPE TO BE SPECIFIC.
 ALL SPECS SHALL INDICATE A NRTL.
 215.5
  
 4) NOTE: PLEASE SEE HEATER AS LISTED ON
 PANEL SCHEDULE SHOWS 2-POLE 60A ON#8.
 PLEASE SEE 240.4,310.16,240.6, AS THIS
 MUST BE # 6 AWG OR LARGER.
  
 5) NOTE: PLEASE INDICATE ALL CONTINUOUS
 LOADS AT 125%. LOADS ONLY SHOWTHE
 LARGEST MOTOR LOAD AT 125%.
 PLEASE KNOW THE HEAT PUMP WILL RUN 3 OR
 MORE HRS AND WILL BE CONSIDERED
 CONTINUOUS. 215.3,230.42
  
 6) NOTE: PLEASE SEE PLANS MISSING THE
 REQUIRED EQUIPMENT GROUNDING CONDUCTOR
 FEEDING NEW SUB PANEL.
  
 7) NOTE: PLEASE SUBMIT LOAD CALCULATIONS
 FOR THE EXISTING SERVICE AND THE
 ADDITION OF THE NEW LOADS. PLEASE SEE
 ONLY THE LOADS FOR THE NEW SUB PANEL
 WERE SUBMITTED AND NO INFORMATION FOR
 SIZE AND EXISTING PANEL/SERVICE LOAD WAS
 GIVEN.
 220.31B,215.5
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2006-04-12 Cont ID  
Sent By mperson Date 2006-04-12 Time 16:10 Rev Time 0.00
Received By mperson Date 2006-04-12 Time 16:10 Sent To B
Notes
2006-04-12 00:00:00NOTE: NO GAS

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-06-07 Cont ID  
Sent By adarroug Date 2006-06-07 Time 15:34 Rev Time 0.00
Received By adarroug Date 2006-06-07 Time 15:34 Sent To P
Notes
2006-06-07 00:00:00TO "P" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-05-24 Cont ID  
Sent By adarroug Date 2006-05-24 Time 13:47 Rev Time 0.00
Received By adarroug Date 2006-05-24 Time 13:47 Sent To E
Notes
2006-05-24 00:00:00TO "E" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-04-10 Cont ID  
Sent By adarroug Date 2006-04-10 Time 16:37 Rev Time 0.00
Received By adarroug Date 2006-04-10 Time 16:37 Sent To E
Notes
2006-04-10 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-04-28 Time   Rev Time 0.00
Received By adarroug Date 2006-04-03 Time 13:34 Sent To  
Notes
2006-04-03 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 3 Status P Date 2006-06-12 Cont ID  
Sent By mperson Date 2006-06-12 Time 13:51 Rev Time 0.33
Received By mperson Date 2006-06-12 Time 13:51 Sent To E
Notes
***NONE***

Review Stop P PLUMBING
Rev No 2 Status F Date 2006-05-30 Cont ID  
Sent By mperson Date 2006-05-30 Time 10:40 Rev Time 0.33
Received By mperson Date 2006-05-30 Time 10:40 Sent To B
Notes
2006-05-30 00:00:00******DENIED 2ND TIME******
 REFERENCE: FBC-2004 SEC.424.2,OR
 FBCR-2004 SEC. R4101 SWIMMING POOLS
  
 THE FOLLOWING INFORMATION IS REQUIRED
 FOR PLUMBING PLAN REVIEW FOR A PERMIT:
  
 1) PLEASE CORRELATE THE LEGEND WITH THE
 EQUIPMENT LAYOUT, SEE THE CORRECTED
 DRAWINGS IN RED INK FOR REFERENCE FOR
 RESUBMITTAL.
 2) FBC-2004 SEC. 424.2.14.1, OR
 FBCR-2004 SEC. R4101.14.1 SWIMMING POOL
 WATER HEATERS SHALL BEAR THE LABEL OF A
 RECOGNIZED TESTING AGENCY. (MANUFACTURE
 SHEETS REQUIRED, PLEASE SUBMIT)
 3) FBC-2004 SEC. 424.2.14.2, OR
 FBCR-2004 SEC. R4101.14.2 WATER
 RETENTION, PROVIDE A POSITIVE MEANS OF
 RETAINING WATER IN THE HEATER WHEN PUMP
 IS SHUT OFF.(MANUFACTURE SHEETS
 REQUIRED, PLEASE SUBMIT)
 4) NOTE: THIS IS A CONTINUING PROBLEM
 WITH POOL HEATER MANUFACTURE SUBMITTAL
 SHEETS TO SEE IF THEY COMPLY WITH THE
 ABOVE, IN THE FUTURE PLEASE TRY TO
 COMPLY WITH THE ABOVE IN ORDER TO
 EXPIDITE PLAN REVIEW.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721
  
  
  

Review Stop P PLUMBING
Rev No 1 Status F Date 2006-04-12 Cont ID  
Sent By dpalmer Date 2006-04-12 Time 14:45 Rev Time 0.45
Received By mperson Date 2006-04-12 Time 16:11 Sent To B
Notes
2006-04-12 00:00:00******DENIED******
 REFERENCE: FBC-2004 424.2 SWIMMING POOLS
  
 PLEASE ADJUST YOUR NOTES, DETAILS, OR
 SUMMITTALS TO REFLECT THE FOLLOWING
 INFORMATION REQUIRED FOR PLAN REVIEW.
  
 1. PLEASE CORRELATE THE EQUIPMENT LAYOUT
 WITH THE LEGEND.
 2. PRINT INDICATES A 5 TON ELECTRIC HEAT
 PUMP. THE MANUFACTURER'S SUBMITTAL IS A
 GAS HEATER. PLEASE CORRELATE THE
 MANUFACTURER SUBMITTAL WITH THE PRINT.
  
 END OF COMMENTS:
  
 REVIEW BY MIKE PERSON
 (561) 805-6730
 FAX (561) 805-6731
 E-MAIL [email protected]
 UNDER SUPERVISION OF K.STEVENS
 (561) 805-6721

Review Stop Z ZONING
Rev No 1 Status P Date 2006-04-10 Cont ID  
Sent By mmclean Date 2006-04-10 Time 14:16 Rev Time 0.00
Received By mmclean Date 2006-04-10 Time 14:16 Sent To I
Notes
2006-04-10 00:00:00SPA & ONLY.