Plan Review Details - Permit 06040006
Plan Review Stops For Permit 06040006
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-06-08 Cont ID  
Sent By mjacobs Date 2006-06-08 Time 07:15 Rev Time 0.00
Received By mjacobs Date 2006-06-08 Time 06:49 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-04-28 Cont ID  
Sent By mjacobs Date 2006-04-28 Time 06:50 Rev Time 0.00
Received By mjacobs Date 2006-04-28 Time 06:35 Sent To PC
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-05-25 Cont ID  
Sent By btrobaug Date 2006-05-25 Time 18:22 Rev Time 0.33
Received By btrobaug Date 2006-05-25 Time 18:16 Sent To P
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-04-11 Cont ID  
Sent By dpalmer Date 2006-04-11 Time 15:20 Rev Time 0.00
Received By dpalmer Date 2006-04-11 Time 15:16 Sent To P
Notes
2006-04-11 00:00:00********** UNSAT ************
  
 1) NOTE: PLEASE SEE NEC TABLES CHAPTER 9
 FOR MIN CONDUITS FILL FOR POOL PANEL
 SUB-FEED.
 215.5
  
 2) NOTE: PLEASE COMPLETE MIN WIRING ON
 ELECTRICAL WIRING DIAGRAM FOR EQUIPMENT.
 PLEASE SEE PUMP, HEATER, ETC DO NOT
 INDICATE ANY SIZES ETC.
 240.4,310.16,215.5
  
 3) NOTE: PLEASE SEE SPECS SUBMITTED FOR
 POOL HEATERARE FOR A GAS HEATER AND
 PLANS MENTIONS AN ELECTRICAL HEAT PUMP
 AND A GAS HEATER?
 PLEASE ADJUST PLANS,OR LOADS AND PANEL
 SCHEDULE ACCORDINGLY.
 PLEASE SUBMIT SPECS FOR THE HEAT PUMP
 BEING INSTALLED IN THIS HOUSE AND FOR
 THIS JOB. SPECS AND CALCS SHALL NOT BE
 GENERIC AS THE CODE REQUIRES EACH
 JOBSITE SCOPE TO BE SPECIFIC.
 ALL SPECS SHALL INDICATE A NRTL.
 215.5
  
 4) NOTE: PLEASE SEE HEATER AS LISTED ON
 PANEL SCHEDULE SHOWS 2-POLE 60A ON#8.
 PLEASE SEE 240.4,310.16,240.6, AS THIS
 MUST BE # 6 AWG OR LARGER.
  
  
 5) NOTE: PLEASE INDICATE ALL CONTINUOUS
 LOADS AT 125%. LOADS ONLY SHOWTHE
 LARGEST MOTOR LOAD AT 125%. PLEASE
 CLARIFY THE 125% SHOWN AS LARGEST MOTOR
 LOAD? IS THIS THE HEAT PUMP?
 PLEASE KNOW THE HEAT PUMP WILL RUN 3 OR
 MORE HRS AND WILL BE CONSIDERED
 CONTINUOUS. 215.3,230.42
  
 6) NOTE: PLEASE SEE PLANS MISSING THE
 REQUIRED EQUIPMENT GROUNDING CONDUCTOR
 FEEDING NEW SUB PANEL.
  
 7) NOTE: PLEASE SUBMIT LOAD CALCULATIONS
 FOR THE EXISTING SERVICE AND THE
 ADDITION OF THE NEW LOADS. PLEASE SEE
 ONLY THE LOADS FOR THE NEW SUB PANEL
 WERE SUBMITTED AND NO INFORMATION FOR
 SIZE AND EXISTING PANEL/SERVICE LOAD WAS
 GIVEN.
 220.31B,215.5
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  

Review Stop G GAS REVIEW
Rev No 2 Status N Date 2006-06-06 Cont ID  
Sent By mperson Date 2006-06-06 Time 13:49 Rev Time 0.00
Received By mperson Date 2006-06-06 Time 13:49 Sent To B
Notes
2006-06-06 00:00:00NOTE: GAS PERMIT REQUIRED. GAS CONTRAC-
 TOR TO SUBMIT PLANS WITH PERMIT APPLICA-
 TION. ALL GAS INSPECTIONS TO BE COMPLETE
 BEFORE FINAL POOL INSPECTION.

Review Stop G GAS REVIEW
Rev No 1 Status N Date 2006-04-12 Cont ID  
Sent By mperson Date 2006-04-12 Time 15:23 Rev Time 0.00
Received By mperson Date 2006-04-12 Time 15:23 Sent To B
Notes
2006-04-12 00:00:00NOTE: GAS PERMIT REQUIRED. GAS
 CONTRACTOR TO SUBMIT PLANS WITH PERMIT
 APPLICATION. ALL GAS INSPECTIONS TO BE
 COMPLETE BEFORE FINAL POOL INSPECTION.

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-05-24 Cont ID  
Sent By adarroug Date 2006-05-24 Time 13:19 Rev Time 0.00
Received By adarroug Date 2006-05-24 Time 13:19 Sent To E
Notes
2006-05-24 00:00:00TO "E" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date   Cont ID  
Sent By   Date 2006-04-28 Time   Rev Time 0.00
Received By adarroug Date 2006-04-10 Time 16:38 Sent To  
Notes
2006-04-10 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-04-28 Time   Rev Time 0.00
Received By adarroug Date 2006-04-03 Time 13:35 Sent To  
Notes
2006-04-03 00:00:00TO "Z" BOX

Review Stop P PLUMBING
Rev No 2 Status P Date 2006-06-06 Cont ID  
Sent By mperson Date 2006-06-06 Time 13:46 Rev Time 0.33
Received By mperson Date 2006-06-06 Time 13:46 Sent To G
Notes
2006-06-06 00:00:00NOTE: NEW SHEETS DUE TO ELECTRICAT PLAN
 REVIEW COMMENTS

Review Stop P PLUMBING
Rev No 1 Status P Date 2006-04-12 Cont ID  
Sent By mperson Date 2006-04-12 Time 15:27 Rev Time 0.33
Received By mperson Date 2006-04-12 Time 15:26 Sent To B
Notes
***NONE***

Review Stop Z ZONING
Rev No 1 Status P Date 2006-04-10 Cont ID  
Sent By mmclean Date 2006-04-10 Time 14:21 Rev Time 0.00
Received By mmclean Date 2006-04-10 Time 14:21 Sent To I
Notes
2006-04-10 00:00:00POOL ONLY. POOL EQUIPMENT CAN ONLY
 ENCROACH 4FT INTO A SETBACK.