Plan Review Details - Permit 06031430
Plan Review Stops For Permit 06031430
Review Stop B BUILDING (STRUCTURAL)
Rev No 4 Status P Date 2007-05-29 Cont ID  
Sent By mjacobs Date 2007-05-29 Time 09:14 Rev Time 0.00
Received By mjacobs Date 2007-05-29 Time 08:57 Sent To PC
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 3 Status F Date 2007-03-01 Cont ID  
Sent By mjacobs Date 2007-03-01 Time 14:05 Rev Time 0.00
Received By mjacobs Date 2007-03-01 Time 12:47 Sent To  
Notes
2007-03-01 16:23:38BUILDING PLAN REVIEW
 PERMIT:
 ADD:
 CONT:
 TEL: (561)###-####
 FL BLD CODE= 2004 FLORIDA BUILDING CODE
 W/ 2006 FBC REVISIONS
 * WEST PALM BEACH AMENDMENTS
  
 REVIEW
 ACTION: DENIED
  
 1)--- VERY IMPORTANT STATEMENT ---
 PLEASE DO NOT IGNORE!
 WHEN RESUBMITTING PLANS PLEASE INDICATE
 THE REVISION & REMOVE & REPLACE ANY
 PAGES AS NECESSARY. A TRANSMITTAL LETTER
 LISTING THE ORIGINAL REVIEW COMMENT NUM-
 BER, WITH A DESCRIPTION OF THE REVISION
 MADE, IDENTIFYING THE SHEET OR SPECIFICA
 TION PAGE WHERE THE CHANGES CAN BE FOUND
 WILL HELP TO EXPEDITE YOUR PERMIT. THANK
 YOU FOR YOUR ANTICIPATED COOPERATION.
  
 2)THE DRAWINGS SHALL BE CLEAR AND LEGIBLE.THE
 INFORMATION ON ONE SET OF THE DRAWINGS IS NOT LEGIBLE.
 SUBMIT TWO CLEAR SETS OF THE REVISIONS WHICH MEETS THE
 REQUIREMENTS OF FBC. 106.1.1.
  
 3) THE AREA WHERE THE CHANGES ARE MADE, CLOUD THE NOTES
 WHICH AFFECT THE RERVISIONS SO IT WILL BE CLEAR WHERE
 THE CHANGES ARE.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 805-6726
  

Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-05-12 Cont ID  
Sent By amorse Date 2006-05-12 Time 11:06 Rev Time 0.50
Received By amorse Date 2006-05-12 Time 11:06 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-04-27 Cont ID  
Sent By amorse Date 2006-04-27 Time 10:49 Rev Time 1.00
Received By amorse Date 2006-04-27 Time 10:49 Sent To PC
Notes
2006-04-27 00:00:00 
  
 DENIED
  
 1) PROVIDE CORRECT DESIGN CRITERIA,
 SHALL COMPLY WITH 2004 FBC AND
 APPLICABLE TABLES
  
 2) PROVIDE SITE PLAN AND ELEVATON OF
 BUILDING TO VERIFY COMPLIANCE WITH THE
 PROVISIONS OF SECTION 1022 FBC
  
 3) STAIR TREADS SND RISERS SHALL COMPLY
 WITH THE PROVISIONS OF 1009.3 AND
 11-4.9.2 FBC (MAX RISE 7" MIN RUN 11")
  
 4) DETAIL 2 SHOWS TREAD OF 11" WHILE THE
 ELEVATION SHOWS 9 7/8" PLEASE CLARIFY
  
 5) PROVIDE FOUNDATION DETAIL FOR NEW
 STEEL COLUMNS
  
 6) PROVIDE ADDITIONAL INFORMATION :
 OCCUPANCY TYPE FOR BOTH FLOORS, IS THIS
 THE ONLY MEANS OF EGRESS FOR 2ND FLOOR
  
 BLDG PLAN REVIEW
 ADRIAN MORSE
 561-805-6716

Review Stop FIRE FIRE DEPARTMENT
Rev No 4 Status P Date 2007-05-25 Cont ID  
Sent By mwennerg Date 2007-05-25 Time 13:32 Rev Time 0.00
Received By mwennerg Date 2007-05-25 Time 13:32 Sent To  
Notes
2007-05-25 13:37:57***PROVISO***
  
 1) HANDRAILS AND GUARDS SHALL COMPLY WITH PRESCRIPTIVE
 STRENGTH REQUIREMENTS.
  
 2) ADDRESS IN TITLE BLOCK IS DIFFERENT THAN WHATS SHOWN
 ON REVISION SUBMITTAL.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW
 FIRE PREVENTION (561) 804-4756

Review Stop FIRE FIRE DEPARTMENT
Rev No 3 Status F Date 2007-03-20 Cont ID  
Sent By mwennerg Date 2007-03-20 Time 16:00 Rev Time 0.00
Received By mwennerg Date 2007-03-20 Time 16:00 Sent To  
Notes
2007-03-20 16:05:47***DENIED***
  
 1) PLEASE SEE BUILDING REVIEW COMMENTS #2&3 REGARDING
 CLEAR AND LEGIBLE DRAWINGS.
  
  
 MIKE WENNERGREN, ASSISTANT FIRE MARSHAL
 FIRE PLAN REVIEW(561) 805-6722
 FIRE PREVENTION(561) 804-4756

Review Stop FIRE FIRE DEPARTMENT
Rev No 2 Status P Date 2006-05-23 Cont ID  
Sent By mwennerg Date 2006-05-23 Time 15:14 Rev Time 0.00
Received By mwennerg Date 2006-05-23 Time 15:14 Sent To  
Notes
***NONE***

Review Stop FIRE FIRE DEPARTMENT
Rev No 1 Status F Date 2006-04-19 Cont ID  
Sent By nmccray Date 2006-04-19 Time 10:07 Rev Time 0.00
Received By nmccray Date 2006-04-19 Time 09:51 Sent To  
Notes
2006-04-19 00:00:00************DENIED:***********
  
 PLEASE REVIEW AND REFERENCE NFPA 101
 LIFE SAFETY CODE 2003 EDITION ON NEW
 STAIRS REQUIREMENTS. THE MAXIMUM HEIGHT
 OF RISERS IS 7 INCHES AND THE MINIMUM
 TREAD DEPTH IS 11 INCHES.
  
 NATE MCCRAY, ASSISTANT FIRE MARSHAL
 561-804-4754

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2007-05-04 Cont ID  
Sent By adarroug Date 2007-05-04 Time 11:03 Rev Time 0.00
Received By adarroug Date 2007-05-04 Time 11:03 Sent To  
Notes
2007-05-07 13:22:55TO "BOB"#17
2007-05-04 11:04:02WAITING FOR "COMM" BD

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2007-02-23 Cont ID  
Sent By adarroug Date 2007-02-23 Time 11:55 Rev Time 0.00
Received By adarroug Date 2007-02-23 Time 11:55 Sent To  
Notes
2007-02-23 11:57:16TO "BOB"#1

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-05-12 Cont ID  
Sent By adarroug Date 2006-05-12 Time 08:56 Rev Time 0.00
Received By adarroug Date 2006-05-12 Time 08:56 Sent To  
Notes
2006-05-12 00:00:00WAITING FOR "BOB"
 TO "BOB"#3

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-04-27 Time   Rev Time 0.00
Received By adarroug Date 2006-03-30 Time 16:32 Sent To  
Notes
2006-03-30 00:00:00TO "BOB"#13