Plan Review Details - Permit 06031290
Plan Review Stops For Permit 06031290
Review Stop B BUILDING (STRUCTURAL)
Rev No 2 Status P Date 2006-05-25 Cont ID  
Sent By alange Date 2006-05-25 Time 16:46 Rev Time 0.75
Received By alange Date 2006-05-25 Time 16:46 Sent To  
Notes
***NONE***

Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status P Date 2006-04-24 Cont ID  
Sent By alange Date 2006-04-24 Time 09:18 Rev Time 0.00
Received By alange Date 2006-04-24 Time 16:46 Sent To  
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 2 Status P Date 2006-05-24 Cont ID  
Sent By btrobaug Date 2006-05-24 Time 14:34 Rev Time 0.50
Received By btrobaug Date 2006-05-24 Time 13:42 Sent To B
Notes
***NONE***

Review Stop E ELECTRICAL
Rev No 1 Status F Date 2006-04-12 Cont ID  
Sent By dpalmer Date 2006-04-12 Time 16:41 Rev Time 0.00
Received By dpalmer Date 2006-04-12 Time 14:58 Sent To M
Notes
2006-04-12 00:00:00******UNSAT *********
  
  
 1) NOTE: PLEASE WHOW THE FOLLOWING
 CURRENT CODES FOR ELECTRICAL PLANS.
 2002 NFPA-70, 2002 NFPA-72.
  
 2) NOTE: PLEASE SEE MECH SHEETS/ PLANS
 COULD NOT BE LOACTED FOR COMPARISON OF
 EQUIPMENT ETC TO THE ENERGY CODE AND
 CORRELATION WITH ELECTRICAL PLANS.
 471.025
  
 3) NOTE: PLEASE SEE SEAL FOR ENGINEER
 WITH THE WORDING OF "CERTIFICATE" HAS
 EXPIRED FOR USE. PLEASE SEE FAC
 61G15-23.001, WHICH REQUIES THE SEAL TO
 INDICATE THE WORDING OF "LICENSE". THIS
 WAS PASSED IN FEB 04 AND AN EXTENSION
 WAS GRANTED TO THE DATE OF DEC 30TH,
 2005.
 SEAL IS TO BE UPADTED.
 ** PLEASE ALSO BE SURE ALL SEALS ARE
 RAISED, CLEAR AND VISABLE WIHT ALL
 INFORMATION ON SAID SAL. FS 471.025
  
 4) NOTE:PLEASE SEE NOTES FOR SCOPE PF
 WORK MENTIONS ALL NEW ELECTRICAL
 SERVICE, YET RISER MENTIONS EXISTING?
 PLEASE CORRELATE.
 IF NEW AND DUE TO THE SCOPE OF WORK AND
 LEVEL OF REPAIR AND ALTERATION UNDER FBC
 AND EXISTING DWELLINGS, IF CONDUIT TO
 MCB PANEL IS NOT IN SLAB FROM METER, A
 MAIN DISCONNECT CONTAINING OCP WILL BE
 REQUIRED LOCATED OUTSIDE BEFORE ENTERING
 DWELLING. PLEASE SEE 230.70
 PLEASE SHOW THE LOCATION OF THE METER
 AND PLEASE INDICATE IF FEED TO PANEL IS
 LOCATED UNDER GROUND.
  
 5) NOTE: PLEASE SEE A FEW MISSING
 RECEPTS PER 210.52. PLEASE SEE SPACING
 WITHIN 6' OF DOORS AND EVERY 12' THERE
 AFTER.
  
 6) NOTE: PLEASE KNOW, IF SERVICE IS NEW,
 PLEASE SUBMIT AIC RATINGS FOR ALL NEW.
 110.9,215.5
  
  
 7 NOTE: PLEASE SEE RISER MENTIONS TO
 TAKE THE GROUNDING ELECTRODE CONDUCTOR
 TO THE EXISTING FOUNDATION STEEL. PLEASE
 KNOW, IF THIS IS AN EXISTING BUILDING
 AND THE ATTACHMENT IS NOT THERE, THIS IS
 NOT REQUIRED BY THIS AHJ. IN FACT, THIS
 MAY INDEED AFFECT THE STRUCTURAL
 STRENGTH OF THE EXISTING FOOTING. THIS
 MAY BE DONE , HOWEVER THIS IS NOT
 REQUIRED,
 ** PLEASE KNOW, IF SHOWN ON PLANS/RISER
 THEN THIS WILL BE REQUIRED.
  
  
 ** PLEASE SEE ANY OTHER COMMENTS FROM
 OTHER TRADES WHICH MAY AFFECT THE
 ELECTRICAL PLANS.
  
 *** BEFORE RESUBMITTING PLANS, PLEASE
 COMPLETELY REMOVED ALL OLD/VOIDED SHEETS
 FROM SETS AND ONLY INSERT NEW REVISED
 SHEETS INTO TWO SETS FOR REVIEW AND
 STAMPIN.
 ONLY ONE COPY OF THE OLD/VOIDED REMOVED
 SHEETS SHOULD BE SUBMITTED FOR
 REFERENCE.
  
  
 PLEASE SUBMIT THE ABOVE INFORMATION FOR
 REVIEW. IF THERE ARE ANY QUESTIONS,
 PLEASE DO NOT HESITATE IN CONTACTING
 THIS OFFICE.
  
 DEWEY PALMER
 ELECTRICAL PLAN REVIEW
 561-805-6717
 [email protected]
  

Review Stop I INCOMING/PROCESSING
Rev No 4 Status N Date 2006-05-22 Cont ID  
Sent By adarroug Date 2006-05-22 Time 13:08 Rev Time 0.00
Received By adarroug Date 2006-05-22 Time 13:08 Sent To E
Notes
2006-05-22 00:00:00TO "E" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 3 Status N Date 2006-05-04 Cont ID  
Sent By adarroug Date 2006-05-04 Time 13:24 Rev Time 0.00
Received By adarroug Date 2006-05-04 Time 13:24 Sent To Z
Notes
2006-05-04 00:00:00TO "Z" BOX/RESUB

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-04-06 Cont ID  
Sent By adarroug Date 2006-04-06 Time 10:01 Rev Time 0.00
Received By adarroug Date 2006-04-06 Time 10:01 Sent To E
Notes
2006-04-06 00:00:00TO "E" BOX

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date 2006-04-24 Cont ID  
Sent By alange Date 2006-04-24 Time 09:18 Rev Time 0.00
Received By alange Date 2006-03-28 Time 14:50 Sent To  
Notes
2006-03-28 00:00:00TO "Z" BOX

Review Stop M MECHANICAL (A/C)
Rev No 1 Status N Date 2006-04-13 Cont ID  
Sent By tgordon Date 2006-04-13 Time 08:11 Rev Time 0.20
Received By tgordon Date 2006-04-13 Time 08:11 Sent To P
Notes
2006-04-13 00:00:00NO MECHANICAL PLANS SUBMITTED, AND NO
 MECHANICAL PERMIT NUMBER APPLIED FOR AT
 THIS TIME.

Review Stop P PLUMBING
Rev No 1 Status N Date 2006-04-13 Cont ID  
Sent By jleech Date 2006-04-13 Time 12:28 Rev Time 0.00
Received By jleech Date 2006-04-13 Time 12:28 Sent To B
Notes
2006-04-13 00:00:00NO DISCRIPSION OR WHAT PLUMBING WORK IS
 TO BE DONE AND NO PLUMBING PERMIT
 NUMBER. PLUMBING PERMIT REQUIRED
 DISCRIPSION OF WORK AND RISER DIAGRAM
 REQUIRED WITH APPLICATION.

Review Stop Z ZONING
Rev No 2 Status P Date 2006-05-19 Cont ID  
Sent By mmclean Date 2006-05-19 Time 16:58 Rev Time 0.00
Received By mmclean Date 2006-05-19 Time 16:58 Sent To I
Notes
2006-05-19 00:00:00PROPOSED ADDITION

Review Stop Z ZONING
Rev No 1 Status F Date 2006-04-05 Cont ID  
Sent By mmclean Date 2006-04-05 Time 07:43 Rev Time 0.00
Received By mmclean Date 2006-04-05 Time 07:43 Sent To I
Notes
2006-04-05 00:00:00DENIED,
 1. MUST PROVIDE TWO COPY OF SURVEY
 SHOWING THE PROPOSED ADDITION WITH
 SETBACKS.
 2. THE SURVEY PROVIDED SHOWS THE
 EXISTING STRUCUTRE, BUT NOT THE PROPOSED
 ADDITION WHICH CHANGES THE FOOTPRINT OF
 STRUCTURE.
  
 MICHELLE MCLEAN
 ZONING TECHNICIAN
 805-6720