Plan Review Details - Permit 06030405
Plan Review Stops For Permit 06030405
Review Stop B BUILDING (STRUCTURAL)
Rev No 1 Status F Date 2006-04-06 Cont ID  
Sent By mjacobs Date 2006-04-06 Time 13:33 Rev Time 0.00
Received By mjacobs Date 2006-04-06 Time 11:21 Sent To PC
Notes
2006-04-06 00:00:001) ALL PLANS SUBMITTED AFTER OCTOBER, 1,
 2004 SHALL BE DESIGNED TO THE 2004
 FLORIDA BUILDING CODE.
  
 2) 3105.4.2.1
 THE WIND DESIGN LOADS FOR ANY FABRIC OR
 MEMBRANE-COVERED STRUCTURE DESIGNED WITH
 A QUICK REMOVAL OR BREAKAWAY MEMBRANE OR
 FABRIC AT WIND VELOCITIES OF 75 MPH,
 SHALL BE BASED ON THE FOLLOWING
 CRITERIA:
 1.MINIMUM WIND VELOCITY OF 3-SECOND
 WIND GUST 90 MPH
 2.IMPORTANCE FACTOR BASED ON LOW
 HAZARD TO HUMAN LIFE OF 0.77.
 3.EXPOSURE CATEGORY B FOR OR C AS
 DEFINED IN CHAPTER 16 . SHOW A DETAIL
 DRAWING OF THE QUICK REMOVAL OR
 BREAKAWAY SYSTEM WHICH WILL BE USED.
 SEE FBC. SECTION 3501 FOR MORE
 INFORMATION ON LOADS AND DESIGN ETC.
  
 3) 2004 FL. BLD CODE 1603.1.4 THE
 FOLLOWING INFORMATION RELATED TO WIND
 SHALL BE SHOWN ON THE CONSTRUCTION
 DRAWINGS,
 1)- BASIC WIND SPEED, MPH
 2)- WIND IMPORTANCE FACTOR, & BUILDING
 CATEGORY
 3)- WIND EXPOSURE
 4)- INTERNAL PRESSURE COEFFICIENT,
 5)- COMPONENTS & CLADDING, THE DESIGN
 WIND PRESSURES IN TERMS OF PSF.
  
 4) FL S S 713.13
 NOTICE OF COMMENCEMENT, TO BE FILED
 WITH THE CLERK OF THE COURT BEFORE A
 PERMIT WILL BE ISSUED. NOTE: 713.13(2)
 IF THE WORK DESCRIBED IN THE NOTICE OF
 COMMENCEMENT IS NOT ACTUALLY COMMENCED
 WITHIN 90 DAYS AFTER THE RECORDING
 THEREOF, SUCH NOTICE IS NULL & VOID.
  
 MYRON JACOBS
 BUILDING PLAN REVIEWER
 TEL:(561)805-6726

Review Stop I INCOMING/PROCESSING
Rev No 2 Status N Date 2006-03-16 Cont ID  
Sent By adarroug Date 2006-03-16 Time 16:19 Rev Time 0.00
Received By adarroug Date 2006-03-16 Time 16:19 Sent To B
Notes
2006-03-16 00:00:00TO "MISC" BOX#2

Review Stop I INCOMING/PROCESSING
Rev No 1 Status N Date   Cont ID  
Sent By   Date 2006-04-06 Time   Rev Time 0.00
Received By adarroug Date 2006-03-10 Time 10:22 Sent To  
Notes
2006-03-10 00:00:00TO "Z" BOX

Review Stop Z ZONING
Rev No 1 Status P Date 2006-03-16 Cont ID  
Sent By mmclean Date 2006-03-16 Time 15:35 Rev Time 0.00
Received By mmclean Date 2006-03-16 Time 15:35 Sent To I
Notes
***NONE***


Account Summary | Usage Policy | Privacy Policy
Copyright © 2005 – 2014, SunGard Pentamation, Inc & City of West Palm Beach, FL – All Rights Reserved